  • RGO ONE is classic super heterodyne single conversion SSB/CW amateur transceiver covering HF bands 80/40/30/20/17/15/12/10m. Bands 160m (1.8-2.0MHz) and 60m (5.250 – 5.450MHz) can be added anytime by optional 160/60m BPF board. Two band pass filters are suited on the board which should be attached to the transceiver main BPF board located on the bottom side.

  • Optional BPF board works on both RX and TX. If your RGO ONE has been purchased factory built and aligned it has 160m low pass filter already installed (40m low pass fitler covers 60m band) so no other parts are needed to start making QSO’s on 160m and 60m bands.

Specifications

  • Operating bandwith: 160m 1.8 ÷ 2.0MHz
  • Operating bandwith: 60m 5.25 ÷ 5.45MHz
  • RX Sensitivity (MDS): -129dbm
  • Nominal output power: 160m 40W
  • Nominal output power: 60m 50W
  • Input/output impedance: 50Ω

BAND enable and band limits change in Service menu 79

SERVICE MENU

  • Push and hold ENC.1 button while switching on the radio enables BAND plan menu No 79 LONG press of MTR MNU button enters menu. All service entries plus band plan are available
  • Short press of RIT/XIT CL button dicards the changes made and leaves the menu

RGO-ONE-160-60m-Optional-Board-fig-3

  • FUNCTION selection is controlled by encoder 3 or UP/DOWN buttons
  • PARAMETER selection is controled by encoder4

BAND plan selecton

  • There are eleven bands available (01-11). Defauit values are in table BANDS
  • Choose which band you like to change (encoder 4) then hit encoder 3 button

RGO-ONE-160-60m-Optional-Board-fig-4

  • Lower limit frequency must be assigned. Default frequency is shown first with “Lo” label in front

  • Pressing encoder 2 button toggles band ON and OFF. When switched to OFF band will not appear in the normal operation

  • Tum encoder 4 clockwise or counter-clockwise. Then hit encoder 3 button to fix the value. Upper band limit will appear on LOCD

  • Pressing encoder 2 button toggles band ON and OFF. When switched to OFF band will not appear in the normal operation

  • Assign upper frequency limit by same manner as for lower band limit

  • Tum clockwise or counter-dockwise encoder 4. Then hit encoder 3 button to finish. LCD will show

  • Exit the menu by long press of MTR MNU button (saving current parameters) again
    ATTENTION When 160/60m hardware option is not installed and band 01/03 is not OFF, the radio might not function properly

Schematics

RGO-ONE-160-60m-Optional-Board-fig-8

PCB layout top and bottom sides

Top view

RGO-ONE-160-60m-Optional-Board-fig-10

Bottom view

RGO-ONE-160-60m-Optional-Board-fig-11

Bill of materials

Name Alias Shape order number
C1 3N3 $R0805 C0805 3.3nF 50V C0G
C2 1N $R0805 C0805 1.0nF 50V C0G SAMSUNG
C3 680P $R0805 C0805 680pF 50V C0G SAMSUNG
C4 3N3 $R0805 C0805 3.3nF 50V C0G
C5 1N $R0805 C0805 1.0nF 50V C0G SAMSUNG
C6 10N $R0805 C0805 10nF 50V X7R SAMSUNG
C7 10N $R0805 C0805 10nF 50V X7R SAMSUNG
C8 10N $R0805 C0805 10nF 50V X7R SAMSUNG
C9 10N $R0805 C0805 10nF 50V X7R SAMSUNG
C10 10N $R0805 C0805 10nF 50V X7R SAMSUNG
C11 10N $R0805 C0805 10nF 50V X7R SAMSUNG
C12 10N $R0805 C0805 10nF 50V X7R SAMSUNG
C13 10N $R0805 C0805 10nF 50V X7R SAMSUNG
C14 330P $R0805 C0805 330pF 50V C0G SAMSUNG
C15 100P $R0805 C0805 100pF 50V C0G SAMSUNG
C16 910P $R0805 81-GRM2165C2A911JA1D
C17 100P $R0805 C0805 100pF 50V C0G SAMSUNG
C18 910P $R0805 81-GRM2165C2A911JA1D
C19 10N $R0805 C0805 10nF 50V X7R SAMSUNG
C20 10N $R0805 C0805 10nF 50V X7R SAMSUNG
C21 10N $R0805 C0805 10nF 50V X7R SAMSUNG
C22 10N $R0805 C0805 10nF 50V X7R SAMSUNG
C23 10N $R0805 C0805 10nF 50V X7R SAMSUNG
C24 10N $R0805 C0805 10nF 50V X7R SAMSUNG
C25 10N $R0805 C0805 10nF 50V X7R SAMSUNG
C26 10N $R0805 C0805 10nF 50V X7R SAMSUNG
C27 100P $R0805 C0805 100pF 50V C0G SAMSUNG
C28 330P $R0805 C0805 330pF 50V C0G SAMSUNG
C29 100N $R0805 C0805 100nF 50V X7R SAMSUNG
C30 200P $R0805 C0805 200pF 50V C0G SAMSUNG
J1 HDR_1 HOLE M3x6, lockwasher 3mm
J2 HDR_1 HOLE M3x6, lockwasher 3mm
JP1 HDR2X5 HDR2X5HA!1 HR2X40 1/8 cut
L1 10UH KHS-6 KHS-6 10 uH A71108002
L2 10UH KHS-6 KHS-6 10 uH A71108003
L3 10UH KHS-6 KHS-6 10 uH A71108004
L4 100UH $R1210 CL100uH FDA32
L5 100UH $R1210 CL100uH FDA32
L6 10UH KHS-6 KHS-6 10 uH A71108004
L7 10UH KHS-6 KHS-6 10 uH A71108004
L8 10UH KHS-6 KHS-6 10 uH A71108004
U1 74HC04 SO14 74HC04D
U2 AS169 $SOT6 863-1002-1-ND
U3 AS169 $SOT6 863-1002-1-ND
U4 AS169 $SOT6 863-1002-1-ND
U5 AS169 $SOT6 863-1002-1-ND