Merlin MR555MY WeatherDrive Roller Door Opener Instruction Manual
- June 14, 2024
- Merlin
Table of Contents
Merlin MR555MY WeatherDrive Roller Door Opener
MR555MYQ
Garage Roller Door Opener
Installation and Operating Instructions
Owners Copy: SAVE THESE INSTRUCTIONS for future reference
This manual containsIMPORTANT SAFETY information DO NOT PROCEED WITH THE INSTALLATION BEFORE READING THOROUGHLY
WARNING
IMPORTANT
- The use of the Key Lockable Release is for use in Commercial Applications ONLY, and not to be used when installed in a Residential Application (refer safety standard AS/NZS 60335.2.95). An alternative exit path from the building MUST BE AVAILABLE when using the Key Lockable Feature.
- This Merlin Unit is rated to IP34 and has a UV stabilizer added, however, to ensure the best operation of the opener the installer must ensure that it is protected from the elements by installing the Unit under cover.
The Merlin Unit should not be exposed to driving water or rain, or extended periods of direct sunlight. It must not be immersed in water or sprayed directly by a garden hose or pressure cleaner.
IP RATING CHART
IP Rating Chart
Protection of persons and protectionofequipment indicated by the IP code.
Protection provided by enclosures forelectrical equipmentis indicated by the IP codes two:
CHARACTERISTIC NUMERALS
SAFETY INSTRUCTIONS
WARNING
- Failure to comply with the following instructions may result in serious injury or property damage.
- Read and follow all instructions carefully.
- The garage door opener is designed and tested to offer safe service provided it is installed and operated in strict accordance with the instructions in this manual.
These safety alert symbols mean WARNING : A possible risk to personal safety or property damage exists.
- Keep the garage door balanced. Do not let the garage door opener compensate for a binding or sticking garage door. Sticking, binding or unbalanced doors must be repaired before installing this opener.
- Do not wear rings, watches or loose clothing while installing or servicing a garage door opener. Wear gloves and suitable protective clothing where appropriate.
- Frequently examine the door installation. In particular examine cable, springs and mountings for signs of wear, damage or imbalance. Do not use if repair or adjustment is needed since springs and hardware are under extreme tension and a fault can cause serious personal injury.
- To avoid serious injury from entanglement, remove all ropes, chains and locks connected to the garage door before installing the door opener.
- Installation and wiring must be in compliance with your local building and electrical codes.
- The safety reverse system test is very important. Your garage door MUST reverse on contact with a 40 mm obstacle placed on the floor. Failure to properly adjust the opener may result in serious injury from a closing garage door.
- Repeat the test once a month and make any necessary adjustments.
- This appliance should not be used by children or persons with reduced physical, sensory or mental capablities, or a lack of experience & knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Automatic Drive – Keep away from the area of the door as it may operate unexpectedly.
- WARNING! Product includes wireless transmitters and wall controls that contain coin/button cell batteries. Keep wireless devices and batteries away from children. Battery can cause severe or fatal injuries in 2 hours or less if swallowed or placed inside any part of the body. Seek immediate medical attention if it is suspected that a coin/button cell battery has been swallowed or placed inside any part of the body.
- The opener must not be used on a wicket door (door within a door).
- The Protector SystemTM (IR Beams) must be used for all installations where the closing force as measured on the bottom of the door is over 400 N (40 kgf). Excessive force will interfere with the proper operation of the safety reverse system or damage the garage door.
- Installers must ensure that the doors are installed in a compliant manner as per AS/NZS 60335-2-95.
- After installation, ensure that the parts of the door do not extend over public footpaths or roads.
- Install the wireless wall control (or any additional wall control) in a location where the garage door is visible away from moving parts, at a height of at least 1.5 m and out of the reach of children. Do not allow children to operate push buttons or transmitters. Serious personal injury from a closing garage door may result from misuse of the opener.
- Permanently fasten the warning labels in prominent places, adjacent to wall controls and manual release mechanisms as a reminder of safe operating procedures.
- Activate opener only when the door is in full view, free of obstructions and the opener is properly adjusted. No one should enter or leave the garage while the door is in motion.
- Do not allow children to play near the door or with door controls.
- If the power cable is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid hazard.
- Disconnect electric power to the garage door opener before making repairs or removing covers.
- This opener should not be installed in a damp or wet space exposed to weather.
NOTE:
If your garage has no service entrance door, we recommend an outside quick
release must be installed. This accessory allows manual operation of the
garage door from outside in case of power failure.
INTRODUCTION
CARTON INVENTORY
- Quik start guide
- Stop collar
- Clamp bracket
- Release handle, cord, keys and risk of entrapment card
- E970M four button remote control (2)
- E148M four button wireless wall mount remote control (1)
- Hardware bag
- Weight bar
- Clamp plate
- Warning and risk of entrapment label
- Opener
TOOLS REQUIRED
- Ladder
- Adjustable wrench for U-bolts already installed on the door
- 8 mm socket, 10 mm socket and 13 mm extended socket and socket wrench
- 300 mm socket extension (for minimum side-room installations)
- Drill and 5.5 mm drill bit
- Philips-head screwdriver
- Marker pen
- Rope
- Door stand (not shown)
DOOR REQUIREMENTS
The WeatherDrive (MR555MYQ) is suitable for spring balanced Residential
Rolling garage doors with:
- Maximum door height of 5.5 m.
- Maximum curtain area of 16.5 m2*.
- Maximum door mass of 100 kg.
- The Protector SystemTM (IR Beams) must be installed if the force at the edge of the closing door exceeds 400N (40 kgf). Door axle diameter must not exceed 35 mm.
Ensure that there is at least 45 mm from the edge of the curtain to the edge of the bracket. If the roller door drum wheel is on the edge of the curtain or is a smaller diameter, additional clearance may be required. Assemble the opener to the door axle and the existing door bracket using the U clamp assembly provided. Tighten to 25-28 Nm. Full installation process is in section 13.
CONTROL PANEL
- Terminal Block: used for external accessories (see chart below).
NOTE: The terminal block is weather protected by a rubber grommet.
When using external wiring, the cable holes can be punched through with a small screwdriver. These holes should be sealed with silicon sealant in order to maintain the weather proof rating. NO| FUNCTION| COLOUR| POLARITY| COMMENT
---|---|---|---|---
1| Push button| Red| +ve| Dry contact input for push button wired wall controls.
2| Common| White| -ve| Common terminal for push button, The Protector SystemTM (IR Beams) & accessory power.
3| The Protector SystemTM (IR Beams)| Grey| +ve| The Protector SystemTM (IR Beams) input (pulsing type only
4| Accessory power| Green| +ve| 24v dc 50 mA accessory output available for a universal receiver. - DN Button: used to drive the door DOWN.
- UP Button: used to drive the door UP.
- P Button: used to “PROGRAM” the DOOR LIMITS (see section 14).
- S Button: used to “SAVE” and “DELETE” the “TRANSMITTERS” (see section 23).
- Key Lock: used to lock the engage/disengage mechanisim for commercial applications
- LEDs:
- Program DOWN, and Diagnostic code indicator Number 1.
- Program UP indicator.
- Diagnostic code indicator Number 2.
- Courtesy Light: turns on during operation and automatically turns off after a period of 3 minutes.
TESTING THE DOOR
Complete the following test to ensure your door is well balanced, and not
sticking or binding:
- Disable all locks and remove any ropes connected to the garage door.
- Lift the door to about halfway and then release it. The door should remain spring balanced.
- Raise and lower the door to determine if there are any sticking or binding points (20 kgf is the absolute maximum allowable to raise or lower the door in any position).
If your door does not hold in place or the door binds or sticks, call a qualified door technician before installing the opener.
ATTACHING THE STOP COLLAR
-
The stop collar is required to be installed on the opposite side of the door to where the opener is to be installed.
-
Ensure the U-Bolt holding the door shaft to the door bracket is tightly secure.
(NOTE: This U-Bolt must not be removed or loosened) -
Remove the bolt assembly from the plastic stop collar. Open the collar as wide as possible and push it onto the door shaft.
-
Fit the stop collar hard against the boss of the door drum. Reinstall the bolt assembly onto the stop collar and tighten.
ATTACHING THE WEIGHT BAR
If the door has a lifting handle, remove the handle, nuts & bolts. Place
the weight bar over the handle holes, insert the extended bolts through the
weight bar & fasten the handle back in place.
- Place the weight bar in the centre of the door as shown.
If the door curtain does not have a handle you will need to follow these instructions:
- Use a marker pen to mark the two hole positions.
- Drill two 5.5 mm holes through the two marked positions, then place the weight bar on the inside of the door.
- Use the bolts, washers and nuts (provided) to fasten the weight bar in place.
PINNNG THE DOOR
Note:
A ballooning door may delay the safety reversal response and can compromise
garage door security.
- To remedy any ballooning, insert the supplied self tapping metal screws into where the curtain leaves the roll. Secure these through the curtain into the drum wheel at each end of the roll.
- After determining the correct fastener location as shown, lift the door approximately half a turn from the closed position to allow access for securing the screws.
THE RELEASE HANDLE & CORD
Do not disengage the opener to manual operation with children, persons or
other objects including motor vehicles within the doorway. The door is under
significant tension and if the door has developed a fault or incorrect
tension, it may be unsafe and may fall rapidly.
- The manual release mechanism enables the door to be manually operated during power outages or in an emergency.
- Thread the end of the rope through the loop of the manual release cable.
- Adjust rope length so the handle (when installed) will be no higher than 1.8m above the floor. Secure with an overhand knot. If the door is greater than 2.5m in height the release cord extension kit is required.
- NOTE: Final adjustment of handle height should be completed after the opener is installed. If it is necessary to cut the rope, heat seal the cut end to prevent unravelling.
OPERATING THE MANUAL RELEASE
-
To disengage the opener
Pull the release cord down firmly, (the opener will make a clicking noise). -
To re-engage the opener
Pull the release cord down firmly, (the opener will make a clicking noise).
Disable all locks and remove any ropes connected to the garage door. Take care when operating the manual release as an open door may fall rapidly due to weak or broken springs, or being out of balance.
INSTALLATION
KEY LOCKABLE RELEASE
The use of the Key Lockable Release is for use in Commercial Applications
ONLY, and not to be used when installed in a residential Application (refer
safety standard AS/NZS 60335.2.95). An alternative exit path from the building
MUST BE AVAILABLE when using the Key Lockable Feature
Optional accessory not provided
- Turn OFF the opener mains power (so the door cannot be activated).
- Insert the key into the Maual Release handle and Lock or Unlock as required (an 8 mm allen key can be used to extend the handle if needed).
- Keep the key in a safe place.
- Two keys are provided, if a replacement is needed, refer to a locksmith.
LEFT/RIGHT HAND INSTALLATION
LEFT
(handing must be changed during limit setting – refer to section 14)
INSTALLATION PROCEDURE
Do not allow people to walk under or around the door during the
installation process as serious injury can occur.
NOTE:
The opener can be installed on either side of the door. The following
instructions are for RIGHT HAND INSTALLATIONS (as illustrated i.e. inside the
garage looking out). For left hand installations, reverse the instruction
terminology (eg LEFT for RIGHT etc).
Preparation:
- Place the opener in manual release mode (refer to section 10).
- Completely open the roller door. For safety, tie a rope around the door.
- Ensure the door axle U-BOLT and door mounting bracket on the left hand side (non opener side) are securely fastened.
- Support the door with a door stand, ladder or similar device to safely support the door.
- Mark the position of the door shaft on the right hand door bracket (for reassembly purposes).
- While the door is supported, remove the right hand axle U-Bolt and door mounting bracket from the wall.
Install the opener:
- Slide the opener over the door axle and engage the drive legs into the door drum wheel, either side of a spoke.
- Refit the door mounting bracket to the wall.
- Clamp the opener on the door axle and door bracket in the marked position using the clamp assembly supplied (tighten to 25 – 28 Nm).
- Remove all ropes and the support stand.
- Check the operation of the door in manual mode by raising and lowering by hand. It should operate smoothly without sticking or binding. The disengage handle should already be attached less than 1.8m above the floor (refer to section 9).
Connect the power:
- Position the power cable away from the door curtain and any moving parts.
- Plug the opener into a nearby power point and turn ON.
- The opener light will turn ON and remain ON for 3 minutes.
SETTING THE LIIMITS FOR RIGHT OR LEFT HAD OPERATION AND FORCE
Travel limits set how far your door goes up and down. Your opener must also be
configured for right or left hand installation. If not the door will rotate in
the reverse direction.
- Program Buttons: The Control Panel diagram in section 4 identifies the Control Buttons and LED layout
- Audible Beep: An audible “BEEP” also occurs with each button press. This feature can be turned OFF
- Courtesy light: During the programming sequence, the courtesy light will flash at half strength
NOTE: The WeatherDrive (MR555MYQ) opener is factory configured for right hand installation.
- the opener will operate during this procedure. Make sure the door is clear of obstruction. Ensure your hands are away from any moving parts before activating the door.
Setting the Right or Left Hand Operation:
- Refer to the diagrams on the right for guidance.
- Ensure the door is positioned halfway and the opener is engaged (out of manual mode).
Turn the opener Power ON, the courtesy light will turn ON.
-
Press the “P” button for 5 seconds until LED 3 will flash, as well as LED 2 or LED 1 will flash. For Right Hand setting LED 2 will flash, and for Left Hand setting LED 1 will flash.
-
To change to the opposite setting, simply press the “S” button, and the opposite LED will flash.
-
When the correct hand setting is selected, Press and Release the “P” program button to accept this setting.
Setting the Door Limits: -
Press and hold the “UP” button until the door reaches the desired OPEN position (You can toggle between the “UP” and “DN” buttons to move the door to the correct position. Ensure the bottom rail stops 50 mm below the mechanical stops mounted to the door guides).
-
Press and release the “P” program button to accept this setting.
-
Press and hold the “DN” button until the door reaches the desired CLOSED position (You can toggle between the UP and DN buttons to move the door to the correct position).
-
Press and release the “P” program button to accept this setting.(LED 2 should flash to indicate you are now in Force Learn mode).
Setting the Force Automatically: -
Press and release the “UP” button. The door will travel to the OPEN position with LED 2 flashing.
-
Press and release the “DN” button. The door will travel to the CLOSED position with LED 1 flashing. When fully closed, LED 1 will stop flashing and the courtesy light will change to full power.
This process is now complete
Setting the Force manually: (Only perform if Limits are already set)
- Start with the door fully CLOSED.
- Press the “S” button twice to enter into force learn mode. The courtesy light will go to half strength, and LED 2 will flash quickly.
- Press and release the “UP” button. The door will travel to the OPEN position, then LED 1 will flash quickly.
- Press and release the “DN” button. The door will travel to the CLOSED position, then LED 1 will stop and the courtesy light will change to full power.
This process is now complete.
TESTING THE SAFETY REVERSE SYSTEM
The safety reverse system test is important. The garage door must reverse
on contact with a 40 mm obstacle laid flat on the floor. Failure to properly
adjust the opener may result in serious personal injury from a closing garage
door.
- Operate the door in the down direction. The door must reverse upon contact with the obstacle. If the door stops on the obstacle, remove obstacle and repeat limit and force setting (refer to section 14).
- Repeat the safety reverse system test.
FIXING WARNING LABELS
- Once you have completed your installation and successfully carried out the safety reverse system test (outlined above), install the warning labels provided with your opener as shown.
- The risk of entrapment WARNING label MUST be installed adjacent to the release handle at a height of less than 1.8 m from the floor in a prominent place.
- Any fixed wall control or wireless door control must be mounted at a height of no less than 1.5 m out of the reach of children.
- Read the safety instructions (page 2) for further details concerning safety.
STANDARD INSTALLATION COMPLETE
PROGRAMMING
TIMER TO CLOSE FEATURE (TTC)
Auto close is NOT recommended for households with young children.personal
injury from a closing garage door.
- TIMER TO CLOSE feature: (TTC) 10 to 180 seconds.
- NOTE: The Protector SystemTM (IR Beams) MUST be installed before TTC will operate.
- The Timer to Close feature allows the door to automatically close after a specified time period. During the OPEN door waiting period, the courtesy light will flash continuously.
- If the door encounters an obstruction while closing, the opener will return to the OPEN position and the TTC will begin again.
To activate the Timer to Close:
-
Start with The Protector SystemTM (IR Beams) installed and the door fully CLOSED.
-
Press and Hold both “P” and “DN” buttons for 3 seconds. When the Courtesy light flashes “TWICE”, release both buttons.
-
Press the “UP” for each 10 second interval required for Timer to Close. A “BEEP” will register for each press. “DN” button will reduce the count if needed.
-
Press and release the “P” button to accept this setting.
To deactivate the Timer to Close: -
Start with the door fully CLOSED.
-
Press and Hold both “P” and “DN” buttons for 3 seconds. When the courtesy light flashes “TWICE”, release both buttons.
-
Press and release the “P” button to accept this setting.
The door may operate unexpectedly, therefore do not allow anything to obstruct the path of the door.
SAFETY FIRST!
Whilst Merlin have engineered safety features into your garage door opener, we
urge you to consider fitting The Protector SystemTM (IR Beams) to your new
garage door opener. In many countries these devices are compulsory to assist
in preventing serious injury or property damage. For your own peace of mind
and the safety of others please consider installing this safety device.
PROGRAM TRANSMITTERS TO THE OPENER LIGHT
To program your transmitters to operate your garage door opener light follow
the below steps:
NOTE:
Do not use the same transmitter button that has been previously learned to the
garage door opener for operation.
- Press and release the “S” button, and the “courtesy light” will flash twice (fig.1).
- Press and release the “P” button and the garage door opener will go into courtesy light learn mode for 30 seconds (fig.2).
- Press any transmitter button (fig.3) to learn this channel to the garage door opener courtesy light, the garage door opener “courtesy light” will flash twice.
The transmitter is now learnt to the garage door opener courtesy light.
To Erase all Transmitter Codes
- Press and hold the “S” button on the opener until the courtesy light flashes twice, and continue holding for approximately 8 seconds, until the courtesy light flashes twice again.
- Release the button, all transmitter codes are now erased.
TRAVEL SPEED (OPTIONAL)
- There are two travel speeds available for this opener.(Regular and Slow speed)
- The WeatherDrive MR555MYQ has been factory set for regular speed.
Setting the SLOW SPEED:
- Start with the door fully OPEN.
- Press and Hold both “UP” and “DN” buttons for 3 seconds.
- The Courtesy light will flash “ONCE”. Release both buttons.
To return to REGULAR SPEED:
- Start with the door fully OPEN.
- Press and Hold both “UP” and “DN” buttons for 3 seconds.
- The Courtesy light will flash “TWICE”. Release both Buttons.
CONTROL PANEL E-LOCK (OPTIONAL)
- The WeatherDrive MR555MYQ has been factory set with the Control Panel buttons UNLOCKED.
- After all the Installation and programming processes are complete, the Control Panel buttons can be locked, and all the coded transmitters will remain active.
To Lock the Control Panel:
-
Start with the door fully OPEN.
-
Press and Hold both “S” and “UP” buttons for 3 seconds, while pressing a previously coded transmitter.
-
The Courtesy light will flash “TWICE”. Release all the buttons.
-
The control panel is now LOCKED, and pressing any button will only allow the courtesy light to turn ON. Transmitters remain active.
-
To turn the Control panel back ON, simple repeat the above process using any previously coded transmitter.
AUDIBLE BEEP (OPTIONAL)
The WeatherDrive (MR555MYQ) has been factory set for an audible “BEEP”.
The Audible beep can be turned OFF by using the following method.
- Start with the door fully CLOSED.
- Press and Hold both “S” and “DN” buttons for 3 seconds.
- The courtesy light will flash “TWICE”.
- Release the buttons.
- To turn the audible beep back ON, simply repeat the above process.
VENTILATION MODE – PARTIAL OPENING FEATURE
This is an adjustable, second stop position, that can be pre-set, partially
open for ventilation, pedestrian or pet access, programmed to the Transmitter.
To activate the ventilation mode:
- Start with the door fully CLOSED (figure 1). Drive the opener UP and stop at the position required for you wish to set the door at.
- Enter ventilation activation mode by pressing the P and UP buttons together for 3 seconds (figure 2). Release when the courtesy light flashes once.
- Press the transmitter button that you have allocated for this feature (figure 3). Do not use the button already allocated for normal operation. The courtesy light will flash when the code is accepted.
The transmitter will now operate to and from the “programmed” and the “fully closed position”. Outside this range the transmitter will operate as normal.
To deactivate the partial opening feature:
- Start with the door fully CLOSED.
- Enter ventilation mode by pressing the P and UP buttons together for 3 seconds (figure 2). The courtesy light will flash twice, indicating that deactivation has occurred.
WIRELESS PROGRAMMING (REMOTE ACCESSORIES)
NOTE:
The transmitters supplied with your opener are preprogrammed by the factory.
- Activate the opener only when door is in full view, free of obstruction and properly adjusted. No one should enter or leave the garage while the door is in motion. Do not allow children to operate push buttons or remotes. Do not allow children to play near the door.
If you purchase additional transmitters, the garage door opener must be programmed to accept the new transmitter code.
Program the receiver to match additional transmitter codes:
Using the “S” SAVE Button
- Press and hold the button on the transmitter that you wish to use (1).
- Press and release the “S” button on the opener (2).
- Release the transmitter button when the courtesy light flashes twice. It has learnt the code. If you release the transmitter button before the opener light flashes, the opener has not learnt the code.
The opener will now operate when the transmitter button is pressed.
To Erase all Transmitter Codes
- Press and hold the “S” button on the opener until the courtesy light flashes twice, and continue holding for approximately 8 seconds, until the courtesy light flashes twice again.
- Release the button, all codes are now erased.
INSTALLING YOUR E148M FOUR BUTTON WIRELESSWALL MOUNT REMOTE
- Disconnect power to the opener whilst installing this accessory to prevent accidental activation. Locate minimum 1.5 m above the floor
To install:
- Carefully pry open the E148M and locate the two screws for mounting.
- Attach to the wall using the two screws and wall anchors provided if mounting to a plaster wall. If using a recessed wall box do not use anchors.
- NOTE: Do not overtighten screws.
- NOTE: The wall control supplied with your opener should be pre-programmed by the factory.
- If adding a new wall control, program into the opener before mounting the unit as detailed in the “Wireless Programming” section.
OPERATION AND CARE OR YOUR OPENER
OPERATION OF YOUR OPENER
Your opener can be activated by any of the following devices:
- Opener Control Panel: UP & DOWN buttons, and O.S.C. control button.
- Transmitter: hold the button down until the door starts to move.
- Wireless Entry Keypad: This is an accessory that opens the door using a four digit keycode.
When the opener is activated:
- If open, the door will close. If closed, the door will open.
- If closing, the door will stop.
- If opening, the door will stop (allowing space for entry and exit of pets and for ventilation).
- If the door has been stopped in a partially open or closed position, it will reverse direction.
Obstruction behaviour:
- If an obstruction is encountered while closing, the door will reverse to the fully open position.
- If an obstruction is encountered while opening, the door will stop and briefly reverse.
- The Protector SystemTM (IR Beams) use an invisible beam which, when broken by an obstruction, causes a closing door to open and prevents an open door from closing. It is STRONGLY RECOMMENDED for homeowners with young children or pets.
Opening the door manually:
When releasing the door, the door should be fully closed if possible. Weak
or broken springs could allow an open door to fall rapidly. Property damage or
serious injury could result.
- The door can be opened manually by pulling the release cord down firmly.
- To re-engage the door, pull the release cord down firmly.
The opener lights will turn on under the following conditions:
when the opener is initially plugged in; when power is restored after
interruption or when the opener is activated.The opener light will turn on for
3 minutes when the opener is activated.
CARE OF YOUR OPENER
When properly installed, your opener will operate with minimal maintenance.
The opener does not require additional lubrication.
- Limit and Force Settings: These settings must be checked and properly set when the opener is installed. Weather conditions may cause some minor changes in the door operation, requiring some re-adjustments, particularly during the first year of operation. Refer to limit and force setting in Section 14.
Follow the instructions carefully and repeat the safety reverse test after any adjustment.
- Transmitter: Additional transmitters can be purchased at any time. Refer to chamberlaindiy.com.au or chamberlaindiy.co.nz for compatible transmitters. Any new transmitters must be programmed into the opener.
- Transmitter battery: If the transmission range decreases, replace the battery.
MAINTENANCE OR YOUR OPENER
Once a Month:
- Repeat the safety reverse test (see Section 15). Make any necessary adjustments.
- Manually operate the door. If it is unbalanced or binding, call for professional garage door service.
- Check to be sure that the door opens and closes fully. Set the limits and/or force if necessary.
SPECIFICATIONS
SPECIFICATIONS WEATHERDRIVE (MR555MYQ)
- Input Voltage: 220-240 VAC, 50-60 Hz, 110 W
- Ratd Load: 32 Nm
- Max. Pull Force: 450 N @ O300 mm
- Max. door weight: 100 kg
- Max. lift under spring tension: 20 kg
- Max. door area: 16.5 m2
- Drive: DC gear motor permanent lubrication
- Max. drum rotations: 4 1/2
- Memory registers: 64
- Operating frequency: 433.30/433.92/434.54 MHz
- Operating temperature: 550C to -250C
SPECIAL NOTE:
Merlin strongly recommends that The Protector SystemTM (IR Beams) be installed
on all garage door openers.
WIRING SECTION
TYPICAL WIRING DIAGRAM WEATHERDRIVE (MR555MYQ)
Information for Service Personnel
REPLACE BATTERIES IN TRANSMITTERS
Battery of the transmitters:
- The batteries in the transmitter have a long life.
- If the transmission range decreases, the batteries should be replaced. Batteries are not covered by the warranty.
WARNING! The wireless transmitters contain button/coin cell batteries.
- The battery is hazardous.
- Keep new and used batteries away from children.
- Do not ingest battery. Chemical burn hazard.
- If the coin cell battery is swallowed or placed inside any part of the body, it can cause severe or fatal injuries in 2 hours or less.
- If the battery compartment does not close securely, stop using the product and keep away from children.
- If you think batteries might have been swallowed or placed inside any part of the body, call the 24-hour Poisons Information Centre on 13 11 26 in Australia, or the 24-hour National Poisons Centre on 0800 764 766 in New Zealand, or seek immediate medical attention.
- Dispose of used coin/button cell batteries immediately and safely. Flat batteries can still be dangerous.
Replacing battery (CR2032 or equivalent):
- To replace the battery, turn the transmitter around and open the case with a screwdriver. Lift the cover and lift the control board. Slide the battery to one side and remove the old battery. Be sure to observe the polarity of the battery.
- Assemble the transmitter again following the steps in reverse.
TROUBLESHOOTING
- The opener will not operate from either the UP/DOWN activation button or the transmitters:
- Does the opener have electric power? Plug a lamp into the outlet. If it does not work, check the fuse box.
- Have you disabled all door locks? Review the installation safety instruction warnings on page 4.
- Is there a build-up of ice or snow under the door? The door may be frozen to the ground. Remove any restriction.
- The garage door spring may be broken. Have it replaced by contacting a garage door repairer.
- Opener operates from the transmitter, but not from the wired wall control terminals:
- Check that the wiring connections are correct.
- The door operates from the UP/DOWN activation buttons but not from the wireless wall control or transmitter:
- Program the opener to match the transmitter code. Repeat with all transmitters.
- The transmitter has short range:
- Change the location of the transmitter.
- Check to be sure the antenna on the bottom of the opener extends fully downward.
- Some installations may have shorter range due to a metal door, foil backed insulation, or metal garage siding.
- The batteries may be flat. Replace the batteries.
- The garage door opens and closes by itself:
- Be sure that no transmitter buttons are being pressed.
- Clear the memory and re-program all wireless wall controls and transmitters.
- The door reverses and stops before opening completely:
- Is something obstructing the door? Is it out of balance, or are the springs broken? Remove the obstruction or repair the door.
- Door reverses for no apparent reason and opener lights flash 10 times:
- Check The Protector SystemTM (IR Beams) (if you have installed this accessory). If the red light on the beam is flashing, the alignment is incorrect.
- The door opens but will not close (or reverses while closing):
- Is something obstructing the door? Pull the manual release handle. Operate the door manually. If it is unbalanced or binding, call a trained door systems technician.
- Clear any ice or snow from the garage floor area where the door closes.
- Repeat the limit and force setting. Repeat safety reverse test after adjustments.
- The opener strains to operate the door:
- The door may be out of balance or the springs may be broken. Close the door and use the manual release to disconnect the door. Open and close the door manually. A properly balanced door will stay in any point of travel while being supported entirely by its springs. If it does not, disconnect the opener and call a trained door systems technician.
- The opener motor hums briefly, then will not work:
- Check that the door is not in manual release mode (refer to sections 9 or 10).
- The garage door springs may be broken.
- If the problem occurs on the first operation of the opener, the door may be locked. Disable any door locks.
- The opener will not operate due to a power failure:
- Use the manual release handle to disconnect the door. The door can be opened and closed manually. When power is restored, re-engage the opener to operate it via a transmitter.
- The LED Indicators on the control panel are flashing in sequence:
- Check the diagnostic code in section 30.
OPERATION AND MAINTENANCE
ACCESSORIES
- Model E148M 4 Channel Wireless wall button
- Model E970M 4 Channel remote control
- Model E980M 4 Channel remote control
- Model E964M 4 Channel remote control
- Model E138M 2 Channle Wireless wall button
- Model E960M 4 Channel remote control
- Model E940M 1 Channel visor remote control
- Model E943M 3 Channel visor remote control
- Model E945M 3 Channel mini remote control
- Model E840M Keyless entry system
- Model 774ANZ The Protector SystemTM
- Model E1702M Quick release lock
- Model 760E Outside keyswitch
- Model 827AU Remote LED light
NOTE:
Use of any Chamberlain Group accessories are approved to use with this
opener.This includes genuine Merlin accessories. Generic compatible
accessories are NOT approved for use with this opener.
SPARE PARTS
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid hazard.
- 002A1865 Motor with gearbox & clutch
- 002A1868 Sungear kit
- 002A2265 PCB assembly
- 002A1869 Transformer
- 002A1874 Clamp assembly
- 002A1872 Handle & pull rope assembly
- 002A1864 Absolute Position Encoder (APE)
- 002A1873 Weight bar
- 002A1871 Power cord
DIAGNOSTIC CHART
Your garage door opener is programmed with self-diagnostic capabilities. The
indicator LEDʼs 1 & 3 on the control panel will flash a number of times to
indicate a fault code exists.
DIAGNOSTIC CODE LED1 LED2| SYMPTOM| POSSIBLE
RESOLUTION
---|---|---
1| 1| The garage door opener will not close and the courtesy light flashes.|
The Protector SystemTM (IR beams) are open circuit or wires may be cut.
Inspect sensor wires for a disconnected or cut wire. Turn power off and reboot
the opener.
1| 2| The garage door opener will not close and the courtesy light flashes.|
There is a short circuit wire for the The Protector SystemTM (IR beams).
Inspect The Protector SystemTM (IR beams) wire at all staple points and
replace wire or correct as needed. Turn power off and reboot the opener.
1| 3| The door control will not function.| The wires for the door control are
shorted or the door control is faulty. Inspect the wire at all staple points
and connection points and replace wire or correct as needed.
1| 4| The garage door opener will not close and the courtesy light flashes.|
The Protector SystemTM (IR Beams) are misaligned or were momentarily
obstructed. Realign both sensors to ensure both LEDs are steady and not
flickering. Make sure nothing is hanging or mounted on the door that would
interrupt the sensors path while closing.
1| 5| There is no door movement or motor accelerates before stopping
suddenly.| No RPM pulses have been detected. Check the door manually for
balance, binding or obstructions. Internally the possible cause may be the
motor, logic board or RPM sensor. Try resetting door travel limits. Contact
service centre.
2| 1| Opener fails to operate.| Possible PCB memory failure. Reboot opener by
turning the mains power OFF and then ON after 15 seconds. Reprogram the door
travel limits and force settings. Contact service centre.
2| 2| Opener fails to operate.| Possible PCB Voltage failure. Reboot opener by
turning the mains power OFF and then ON after 15 seconds. Reprogram the door
travel limits and force settings. Contact service centre.
2| 4| Opener fails to operate using the transmitters| Possible receiver
failure. Reboot opener by turning the mains power OFF and then ON after 15
seconds. Recode the transmitters. Contact service centre.
4| 1| Door is moving down, stops and reverses.| Manually open and close the
door. Check for binding or obstructions, such as a broken spring or door lock.
If the door is binding or sticking contact a trained door systems technician.
If door is not binding or sticking, reset the limits (refer to “Program the
Travel Limits and Force” section).
4| 2| Door is moving up, stops and reverses.| Manually open and close the
door. Check for binding or obstructions, such as a broken spring or door lock.
If the door is binding or sticking contact a trained door systems technician.
If door is not binding or sticking, reset the limits (refer to “Program the
Travel Limits and Force” section).
- TM Trademark of The Chamberlain Group LLC
- ® Registered Trademark of The Chamberlain Group LLC
- © 2022 The Chamberlain Group LLC
WARRANTY
DON’T FORGET
Warranty Registration
To validate yourwarranty youmust complete the registration form online at:
Get Connectedwith
Additional purchaseof the myQ Connectivity Kitis required to enablemyQ
functionality.
Visit www.gomerlin.com.auor www.gomerlin.co.nz formore details.
CHAMBERLAIN LIMITED WARRANTY
Merlin® WeatherDrive MR555MYQ
Chamberlain Australia Pty Limited/Chamberlain New Zealand Limited
(Chamberlain), the manufacturer of Merlin automatic garage door openers is
committed to manufacturing and supplying high quality goods. As part of this
commitment, we seek to provide reliable service and support for our goods and
are pleased to provide you, the original purchaser, with this Chamberlain
Limited Warranty.
The benefits given to you under this Chamberlain Limited Warranty are in addition to any rights and remedies that you may have under Australian or New Zealand consumer protection laws. Our goods come with guarantees that cannot be excluded under the Australian Consumer Law, or New Zealand Consumer Guarantess Act 1993. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
Chamberlain’s warranty
What is covered
- Chamberlain warrants to the original purchaser of the Merlin WeatherDrive MR555MYQ Roller Door Opener (Unit) that it is free from defects in materials and workmanship for a period of 3 years (36 months) or 7,500 cycles (each opening & closing of the garage door equals 1 cycle) whichever comes first, from the date of purchase when installed in a residential premise with a residential specified garage door that is designed for the sole purpose of a single-family dwelling.
- Remote controlled transmitters and accessories included with this Unit have a 12 month warranty from date of purchase. These transmitters and accessories are not covered for damage caused by neglect.
What is not covered
- Batteries and globes are not covered under this warranty period.
- Travel costs incurred by Chamberlain or the Professional Dealer in either travelling to or from areas outside a capital city metropolitan area. These costs will be at the purchaser’s expense.
- Additional access costs incurred by a Professional Dealer or Chamberlain in obtaining access where the Unit is not readily accessible. These cost will be at the purchaser’s expense.
Warranty conditions
It is a condition of this Chamberlain Limited Warranty that the Unit is sold,
installed and serviced by a Professional Dealer appointed or authorised by
Chamberlain. A Merlin branded garage door opener purchased over the internet
and installed by a person other than a Professional Dealer will not be covered
by this Chamberlain Limited Warranty.
It is also a condition of this Chamberlain Limited Warranty that for the operating life of the Unit:
- the garage door is spring balanced, is operable by hand and opens and closes with no more than a maximum of 20 kg of lifting weight;
- the garage door and the Unit is professionally maintained and serviced by a Professional Dealer, at a minimum, during the third year of the Chamberlain Limited Warranty period such that the spring balanced door operates according to manufacturer specifications. If your door binds, sticks, or is out of balance, then it must not be used until serviced by a trained door technician or Profesional Dealer. The garage door service fee will be at the purchaser’s expense;
- the warranty is registered by completing the online form at www.gomerlin.com.au or www.gomerlin.co.nz; and
- you retain your sales docket or invoice as proof of purchase, and attach it to this manual to enable you to establish the date of purchase in the unlikely event of a warranty service being required.
Making a claim
During the applicable Chamberlain Limited Warranty period, if you are
concerned that the Unit may be defective, call the Professional Dealer that
sold/installed the opener, or our service centre on the toll free number below
and a Chamberlain technician will diagnose the problem and arrange for this to
be rectified.
Once the problem has been diagnosed, subject to your rights under the applicable Australian and New Zealand consumer protection laws with respect to major failures, Chamberlain or its Professional Dealer will provide you with either, repairs to the Unit or a replacement Unit.Repairs and replacement parts provided under this Chamberlain Limited Warranty are provided free of charge and are warranted for the remaining portion of the original warranty period.
This Chamberlain Limited Warranty provides benefits which are in addition to your other rights and remedies as a consumer.
Exclusions – what voids the warranty
If our service centre determines that a warranty claim has been made in
respect of a failure or defect arising under or out of any exclusion detailed
below such that the claim is not covered under this Chamberlain Limited
Warranty, we may, subject to your other rights and remedies as a consumer,
charge you a fee to repair, replace and/or return the Unit to you.
This Chamberlain Limited Warranty does not cover any failure of, or defect in, the Unit due to:
- non-compliance with the instructions regarding specifications, installation, operation, maintenance and testing of the Unit or of any product with which the Unit is used;
- any attempt by a person other than a Professional Dealer to repair, dismantle, reinstall or move the Unit to another location once it has been installed;
- use of any copy, imitation or replica garage door remotes with your Merlin Unit;
- tampering, neglect, abuse, wear and tear, accident, electrical storm, excessive use or conditions other than normal domestic use;
- problems with, or relating to, the garage door or garage door hardware, including but not limited to the door springs, door rollers, door alignment or hinges;
- problems caused by electrical faults or replacement of batteries or light bulbs, blown fuses, electrical surges, power surges or power strikes, fire, flood, rain, water, lightning or storms;
- water or moisture ingress that causes corrosion or electrical malfunction; corrosion caused by sea air if located near a waterway, beach etc;
- fitment to a commercial door or in a commercial operating application, installation of a residential garage door opener in a commercial or industrial premises other than a single-family dwelling.
- lack of proper maintenance, service or care of the door and Unit;
- any unauthorised modification to the Unit; or
- damage caused by insects, pests or other after sale damage caused by events or accidents outside Chamberlain’s reasonable control and not arising under normal and standard operating conditions.
NB:
A General Purpose Outlet (GPO) ie: power point must be supplied by the
consumer as this electrical fitting does not form a part of the Unit (opener).
If this Chamberlain Limited Warranty does not apply, you may have rights
available to you under the Australian and New Zealand consumer protection
laws.
Liability – Australia only
Except as set out in the Australian Consumer Law (being Schedule 2 of the
Competition and Consumer Act 2010) (as amended, consolidated or replaced):
- all other guarantees, warranties and representations in relation to the Unit or its supply are excluded to the extent that Chamberlain canlawfully exclude them; and
- under no circumstances will Chamberlain be liable for consequential, incidental or special damages arising in connection with the use, or inability to use, the Unit, other than those which were reasonably foreseeable as liable to result from the failure.
Liability – New Zealand only
Except as set out in the Fair Trading Act 1986 and the Consumer Guarantees Act
1993 (as amended, consolidated or replaced):
- all other guarantees, warranties and representations in relation to the Unit or its supply are excluded to the extent that Chamberlain can lawfully exclude them; and
- under no circumstances will Chamberlain be liable for consequential, incidental or special damages arising in connection with the use, or inability to use, the Unit, other than those which were reasonably foreseable as liable to result from the failure.
Note
Chamberlain reserves the right to change the design and specifications of the
Unit without prior notification. Some features or accessories of the Unit may
not be available in certain markets or areas. Please check with your
distributor.Chamberlain reserves the right to change the design and
specifications of the Unit without prior notification. Some features or
accessories of the Unit may not be available in certain markets or areas.
Please check with your distributor.
Chamberlain service centre contact details
Australia
- Phone toll free 1800 665 438
- Fax toll free 1800 888 121
- Unit 1, 75 Epping Road North Ryde, NSW 2113
- Website www.gomerlin.com.au.
- Email customerservice@chamberlainanz.com.
New Zealand
- Auckland phone 09 477 2823
- Phone toll free 0800 653 667
- Fax toll free 0800 653 663
- Website www.gomerlin.co.nz.
Read User Manual Online (PDF format)