COMMSCOPE NVX-CR-SA-SM-NN NOVUX Fiber Optic System Instruction Manual

June 14, 2024
CommScope

COMMSCOPE-LOGO

COMMSCOPE NVX-CR-SA-SM-NN NOVUX Fiber Optic System

COMMSCOPE-NVX-CR-SA-SM-NN-NOVUX-Fiber-Optic-System-
PRODUCT

Product Information

Specifications:

  • Cable retention: Rigid strength member
  • Cable diameter range: 8mm
  • Tools : Optional
  • Kit contents:
    • Carrier
    • Strength member connector with screw
    • Cable ties
    • Silicone tape (1.25 cm / 0.5 Inches width)

Product Usage Instructions

Prepare drop cable:

  1. Make the dual jacket as small as possible and keep a maximum length of 1.2 cm / 0.47 Inches.
  2. Remove the aramid yarn inside the second jacket.
  3. Cut the rigid strength member to a length of 4.5 +0/-0.5 cm / 1.7 +0/-0.2 Inches.
  4. Clean the subunits and remove all grease.
  5. Remove the subunit tube to access the fiber. (Refer to the closure installation instructions for the stripping point of the subunit.)

Strip silicone tape installation:

  1. Use the strip silicone tape provided in the kit: 6.5 X 1.25 cm / 2.56 X 0.5 Inches.
  2. Ensure your hands are clean and degreased before preparing and installing the cables.
  3. Degrease the cable where it will enter the closure.
  4. Make a mark on the cable 2 cm / 0.79 Inches from the jacket end.
  5. Apply the silicone tape between the mark and the jacket end. Remove the protective paper.
  6. Stretch the tape a minimum of 50% while wrapping it around the cable.
  7. First, apply a full turn around the cable, then continue to cover up to the jacket end.
  8. Make one turn at the end point and come back with the remaining tape.

Install strain relief on drop cable:

  1. Slide the strength member connector onto the carrier until you hear a clicking sound.
  2. Install the cable ties in the slots in the carrier, making sure the teeth of the cable tie are facing upwards.
  3. Slide the rigid strength member in the strength member connector between the metal spring and the housing of the strength member connector. Verify that the strength member fits all the way to the end of the lug.
  4. Secure the screw with a Phillips screwdriver.
  5. Tighten the two cable ties, ensuring that the cable tie head is positioned on top of the cable. A cable tie gun can be used with a recommended force of 85N. Cut off excess cable tie strap.

Install drop cable:
To secure the cable to the organizer, the three hooks on the rear side of the carrier should slide into the three slots on the interface plate on the organizer. The top left slot has a locking lip to keep the cable – carrier assembly in place.

  1. Slide the carrier with the cable secured into the slots of the organizer. Push the locking lip in the first slot backward.
  2. Slide the carrier downwards.
  3. The locking lip returns to its original position and the carrier is correctly seated. A clicking sound is observed.

Remove carrier:

  1. Position the fiber guidance pen in the little cavity in the locking lip of the first slot and push the locking lip backward.
  2. When the lock is released, lift the carrier.

FAQ:

Where can I get technical assistance or customer service?
For technical assistance, customer service, or to report any missing/damaged parts, visit us at: http://www.commscope.com/SupportCenter.

Cable diameter range mm Inches
Round cable ≤ 8 ≤ 0.32

Tools

  • Cable stripping and cleaning tools
  • Scissors
  • Phillips screwdriver
  • Cable Tie Gun (optional)

Kit contents

COMMSCOPE-NVX-CR-SA-SM-NN-NOVUX-Fiber-Optic-System-
\(2\)

Description Qty
1 Carrier 1
2 Strength member connector with screw 1
3 Cable ties 2
4 Silicone tape (1,25 cm / 0.5 Inches width) 1

Prepare drop cable

COMMSCOPE-NVX-CR-SA-SM-NN-NOVUX-Fiber-Optic-System-
\(3\)

N.° Description Preparation


1

| ****


Jacket

|   Attention: The distance of the jacket that should be removed is depending on the closure where the cable retention is installed. Distances below are valid for cable stubs:

•     CC 100: 130 ±5 cm / 51 ±2 Inches

•     CC 150: 135 ±2,5 cm / 53 ±1 Inch

•     CC 200: 135 ±2,5 cm / 53 ±1 Inch

•     SRC 100: 90 ±5 cm / 35 ±2 Inches

•     SRC 50: 130 ±5 cm / 51 ±2 Inches

2| Dual jacket (if present)| Make the dual jacket as small as possible; keep a maximum length of 1,2 cm / 0.47 Inches. Remove the aramid yarn inside this second jacket.


3

| ****

Rigid strength member

| Cut the rigid strength member to a length of 4,5 +0/-0,5 cm / 1.7

+0/-0.2 Inches).

The maximum diameter of the strength member is 3,5 mm / 0.14 Inches.


4

| ****

Subunits

| Clean the subunits, and remove all grease. The subunit tube should be removed to access the fiber.

Attention: The stripping  point of the subunit is provided in the closure installation instructions.

COMMSCOPE-NVX-CR-SA-SM-NN-NOVUX-Fiber-Optic-System-
\(4\)

  • Use the strip silicone tape provided in the kit: 6,5 X 1,25 cm / 56 X 0.5 Inches.
    ATTENTION : Make sure your hands are clean and degreased before preparing and installing the cables. Degrease the cable where the cable will enter the closure.

  • Make a mark on the cable 2 cm / 79 Inches from the jacket end.

  • Apply the silicone tape between the mark and the jacket end. Remove the protective paper. Stretch the tape a minimum of 50% while wrapping the tape around the First apply a full turn around the cable, then continue to cover up to the jacket end. Make one turn at the endpoint and come back with the remaining tape.

Install strain relief on the drop cable

  1. Slide the strength member connector onto the carrier until you hear a clicking sound.
  2. Install the cable ties in the slots in the carrier, as shown. Make sure the teeth of the cable tie are facing upwards.
  3. Slide the rigid strength member in the strength member connector between the metal spring and the housing of the strength member connector. Verify the strength member fits all the way to the end of the lug.COMMSCOPE-NVX-CR-SA-SM-NN-NOVUX-Fiber-Optic-System- \(5\)
  4. Secure the screw with a Phillips screwdriver.
  5. Tighten the two cable ties, and make sure the cable tie head is positioned on top of the cable as shown in Figure 5 above. A cable tie gun can be used. The recommended force is 85N. Cut of excess cable tie strap.

Install drop cable
To secure the cable to the organizer, the three hooks on the rear side of the carrier should slide into the 3 slots on the interface plate on the organizer. The top left slot has a locking lip to keep the cable – carrier assembly in place.

  1. Slide the carrier with the cable secured into the slots of the organizer. Push the locking lip in the first slot backward.
  2. Slide the carrier downwards.
  3. The locking lip returns to its original position and the carrier is correctly seated. A clicking sound is observed.COMMSCOPE-NVX-CR-SA-SM-NN-NOVUX-Fiber-Optic-System- \(8\)

Remove carrier

  1. Position the fiber guidance pen in the little cavity in the locking lip of the first slot and push the locking lip backward. When the lock is released, lift the carrier up.
  2. Move the carrier with a cable attached forward.

© 2022 CommScope, Inc. All Rights Reserved

All trademarks identified by ® are registered trademarks in the US and may be registered in other countries. All third-party product names, trademarks, and registered trademarks are the property of their respective owners. This product may be covered by one or more U.S. patents or their foreign equivalents. For patents, see www.cs-pat.com. This document is not intended to modify or supplement any specifications or warranties relating to CommScope products or services. Visit our website or contact your local CommScope® representative for more information. www.commscope.com. For technical assistance, customer service, or to report any missing/damaged parts, visit us at: http://www.commscope.com/SupportCenter.