Enerlites LVS-101 Low Voltage Switch
Product Information
Specifications:
- Voltage: 24VDC
- Current Consumption: 20mA
- Power Supply: Enerlites Room Controller MPP-24
- Connections: 24V, Com, Man, Control
Description:
The LVS-101 is a low voltage switch designed to control ON/OFF functionality for various LED panel lights. It can control a single zone and up to 4 zones with the LVS-104. The LVS-101 operates on 24V supplied by the MPP-24 Power Pack and can easily pair with the occupancy ceiling sensor MPC-50L.
Button and Indicator:
- LED Indicator
- Paddle On/Off Button
Installation Instructions:
To install the LVS-101, follow these steps:
- Make sure the power supply is turned off.
- Connect the LINE and NEUTRAL wires to their respective terminals on the LVS-101.
- Connect the BLACK wire to the common (COM) terminal.
- Connect the RED wire to the 24V terminal.
- Connect the BLUE wire to the control terminal.
- If using the manual switch, connect the GRAY wire to the switch terminal.
- Securely tighten all wire connections.
- Turn on the power supply and test the switch functionality.
Product Usage Instructions
To use the LVS-101, follow these instructions:
For Single Zone:
- Connect the LVS-101 to the MPP-24 and MPC-50L as shown in the diagram for a single zone.
- Make sure the power supply is turned on.
- Press the paddle On/Off button to control the LED panel lights in the single zone.
For Multiple Zones:
- Connect the LVS-101 to the MPP-24 and MPC-50L as shown in the diagram for multiple zones.
- Make sure the power supply is turned on.
- Press the paddle On/Off button to control the LED panel lights in each zone separately.
FAQ
Q: What is the voltage requirement for the LVS-101?
A: The LVS-101 operates on 24VDC.
Q: How many zones can the LVS-101 control?
A: The LVS-101 can control a single zone and up to 4 zones with the LVS-104.
Q: Can I pair the LVS-101 with the occupancy ceiling sensor MPC-50L?
A: Yes, the LVS-101 can easily pair with the occupancy ceiling sensor MPC-50L.
Q: How do I install the LVS-101?
A: To install the LVS-101, follow the installation instructions provided in the user manual. Make sure to turn off the power supply before installation.
LVS-101, LVS-102, LVS-103, LVS-104 Low Voltage Switch
SPECIFICATIONS
- Voltage …………………………………………………………………………………………………….. 24VDC
- Current Consumption …………………………………………………………………………………….20mA
- Power Supply ………………………………………………………Enerlites Room Controller MPP-24
- Connections……………………………………………………………………….24V, Com, Man, Control
DESCRIPTION
LVS-101 is a low voltage switch to control ON/Off for various LED panels lights. Each switch control a single zone up to 4 zones with the LVS-104. The LVD-101 operate on 24V supplied by the MPP-24 Power Pack and can easily pair with our occupancy ceiling sensor MPC-50L.
BUTTON AND INDICATOR
LVS-101 / MPP-24
Single zone
2 separate zones
3 separate zones
4 separate zones
TROUBLESHOOTING
Load does not turn On. Sensor’s LED does not flash regardless of motion:
- Manual switch was activated prior to the sensor preset time delay. Push Manual On/Off Button to turn On the load
- Set the jumper on the LVS to “Com”.
- Select the Occupancy position if “Auto ON” is what’s desired.
The Load does not turn On when LED indicator flashes and motion is detected:
- Switch may be in Vacancy mode. Select the OCC position if “Auto ON” is what’s desired.
- Push Manual On/Off Button to turn On the load
The Load does not turn Off:
- Motion may be detected. The time delay constantly restarts its countdown after the last motion detected.
- To verify proper operation, turn the Time Delay Knob to 15s (Test Mode) and make sure there is no motion (no LED flashing). Tape may be used to cover the fresnel lens while testing.
- Check for significant heat source emitting within six feet (two meters) such as high wattage light bulb, portable heaters or HAVC vents. Check the wiring.
The Load turns on when its not desired:
- Motion may be detected. The time delay constantly restarts its countdown after the last motion detected. To verify proper operation, set the Time Delay switches to 15s (Test Mode) and make sure there is no motion (no LED flashing). Tape may be used to cover the fresnel lens and ultrasonic cones while testing.
- Check for significant heat source emitting within six feet (two meters) such as high wattage light bulb, portable heaters or HAVC vents.
- If Manual operation of push-button is desired, select VAC mode on the Mode Switch.
- If the sensor is installed in a small room, turn the Range dial lower to avoid false or unwanted detection from open window or door.
WARRANTY INFORMATION
This device is warranted to be free of material and workmanship defects for 2 years from the date of purchase. Original receipt or proof of purchase from an authorized retailer must be presented upon warranty claim. ALL claims must be verified and approved by Enerlites, Inc. Warranties from other Enerlites products may vary. This warranty is nontransferable and does not cover normal wear and tear or any malfunction, failure, or defect resulting from misuse, abuse, neglect, alteration, modification, or improper installation. To the fullest extent permitted by the applicable state law, Enerlites shall not be liable to the purchaser or end user customer of Enerlites products for direct, indirect, incidental, or consequential damages even if Enerlites has been advised of the possibility of such damages. Enerlites’ total liability under this or any other warranty, express or implied, is limited to repair, replacement or refund. Repair, replacement or refund are the sole and exclusive remedies for breach of warranty or any other legal theory.