Enerlites 51300 LED CFL Incandescent Halogen Dimmer Switch Instruction Manual

June 14, 2024
ENERLITES

Enerlites 51300 LED CFL Incandescent Halogen Dimmer Switch Instruction

Manual

SPECIFICATIONS

Voltage…………………………………………………………………………………………………………   120VAC, 60Hz
Incandescent/ Halogen…………………………………………………………………………………..  700W
Dimmable LED and Dimmable CFL…………………………………………………………………. 150W
Operating Temperature………………………………………………………………………………….   32°F-104°F

DESCRIPTION/ FEATURES\

The 51300 is an Incandescent/Halogen and dimmable LED & CFL Dimmer. This Dimmer is designed to replace a standard light switch, dimmer, or a three-way lighting control (see 3-Way Wiring, Figure 2).

  • Replaces current light switch using home’s existing wiring
  • Slide dimmer and rocker switch turns lights on to a preset level
  • Provides wider dimming range for dimmable LED and CFL bulbs than standard incandescent dimmers
  • Suitable for multi-gang installations
  • Dim lighting for increased energy savings
  • Adjustable sensitivity levels on the control
  • Designed for compatibility with most high efficiency light

WIRING DIRECTIONS

  1. Connect the HOT wire to the BLACK wire on the switch

  2. Connect the load wire to the uninsulated RED wire on the switch
    a. If using switch as 3-way, remove insulating label from redwire and connect EACH RED wire to separate
    TRAVELER wires.

  3.  Connect GROUND wire to GREEN wire on the switch.

  4.  Mount the dimmer to the box with “UP” indicator pointing up.

  5.  Turn on Circuit Breake

Single-Pole Wiring

MULTIGANG INSTALLATION

When installing more than one control in the same wall box, it may be necessary to remove the side tabs before installing (see below). Using pliers, bend each tab back and forth until they break off. Repeat for each tab to be removed. Removal of tabs WILL REDUCE MAXIMUM LOAD CAPACITY.

When using the 51300 Dimmer to control LED/CFL lights in conjunction with another 51300 Dimmer to control Incandescent /Halogen lights follow this Derating Chart for Maximum Capacity on EACH device.

If you are using ONLY LED/CFL bulbs on ALL 51300 Dimmers, DO NOT USE this Derating Chart. Follow the LED/ CFL Derating Chart

DIMMER ADJUSTMENT

  1. Power the lights on by using the Rocker switch and move the dimmer’s slider down to the

  2. Fine Tuning: To achieve the lowest light level, turn the Tuning dial Upwards/
    Downwards until desired level is reached. (Note: DO NOT overturn. The Dial will stop turning at lowest/ highest outputs).

  3. To verify the setting, turn the dimmer off then back on. Repeat step 2 if all bulbs do not turn

  4. Turn adjustment dial Up until all lights come on. Some dimmable CFLs and LEDs require at least two light bulbs to be installed or 10 total wattage on one lamp for proper operation

WARRANTY INFORMATION

This device is warranted to be free of material and workmanship defects for 2 years from the date of purchase. Original receipt or proof of purchase from an authorized retailer must be presented upon warranty claim. ALL claims must be verified and approved by Enerlites, Inc. Warranties from other Enerlites products may vary. This warranty is nontransferable and does not cover normal wear and tear or any malfunction, failure, or defect resulting from misuse, abuse, neglect, alteration, modification, or improper installation. To the fullest extent permitted by the applicable state law, Enerlites shall not be liable to the purchaser or end user customer of Enerlites products for direct, indirect, incidental, or consequential damages even if Enerlites has been advised of the possibility of such damages. Enerlites’ total liability under this or any other warranty, express or implied, is limited to repair, replacement or refund. Repair, replacement or refund are the sole and exclusive remedies for breach of warranty or any other legal theory