The FB-02 Junction Box is a squared junction box made of galvanized metal. It features a round opening that allows for easy wiring. The cover and flange of the junction box are available in either brass or nickel-plated brass material. The FB 02 is specially designed to be used with various covers and flanges listed below:
- Covers: 975501-C, 975502-C, 975503-C, 975516-C, 975501-SS, 975502-S, 975503-S, 975516-S
- Flanges: 975509-C, 975518-C, 975509-S, 975518-S, 975517-C, 975517-S, 975519-C, 975519-S
The FB-02 Junction Box is recommended for installation by the National Electric Code and local regulations. It is important to have a qualified electrician perform the installation. The device should only be wired with copper wire and the power must be turned off at the circuit breaker before installation.
Product Usage Instructions
- Floor Box Installation
- Before installation, ensure that there is sufficient depth and space below the subfloor.
- Mount the floor box (FB-02):
- Remove knockouts and secure the box onto the floor.
- Pull the wire through the removed knockouts and secure the wires with proper wire clamps or grommets.
- Connect the wires based on the wiring directions.
- Wiring Directions
- Connect the HOT wires to the wire terminals with BLACK screws.
- Connect the NEUTRAL wires to the wire terminals with WHITE (SILVER) screws.
- Connect the GROUND wire to the wire terminal with the GREEN grounding screw.
- Note: If using a receptacle not rated or recommended for use with this floor box, follow the wiring directions provided by the receptacle’s manufacturer.
- Attach the Receptacle and Cover Plate
- Attach the receptacle to the flange that’s mounted on the floor box.
- Attach the support plate to the receptacle.
- Place the gasket on top of the support plate.
- Attach the cover plate to the flange.
- Warranty Information
- The product comes with a warranty. For more information, please visit www.enerlites.com.
SPECIFICATIONS
- Cover & Flange Material…………………………………….Brass or Nickel-Plated Brass
- Junction Box Material………………………………………………………… Galvanized Metal
DESCRIPTION/ FEATURES
FB-02 is a squared junction box with a round opening that allows more room for ease of wiring. It is specially designed for use with the following covers and flanges:
Covers
- 975501-C 975501-SS
- 975502-C 975502-S
- 975503-C 975503-S
- 975516-C 975516-S
- 975517-C 975517-S
- 975519-C 975519-S
Flanges
- 975509-C 975509-S
- 975518-C 975518-S
DIMENSIONS
WARNING
Turn the POWER OFF at the circuit breaker before installing the Floor Box
- Read and understand these instructions before installing.
- This device is intended for installation following the National Electric Code and local regulations.
- It is recommended that a qualified electrician perform this installation.
- Make sure to turn off the circuit breaker or fuse(s) and make sure the power is off before wiring the device.
- Use copper wire only.
NOTES: 10-12 AWG Stranded or Solid Copper wire is recommended.
FLOOR BOX INSTALLATION
Before Installation:
Ensure there is sufficient depth & space below the subfloor.
Step 1 -Mount the floor box (FB-02)
- Remove knockouts and secure the box onto the floor.
- Pull the wire through the removed knockouts and secure the wires with proper wire clamps or grommets.
- Connect the wires based on the wiring directions.
WIRING DIRECTIONS
Step 2 – Connect the wires
- Connect the HOT wires to the wire terminals with BLACK screws.
- Connect the NEUTRAL wires to the wire terminals with WHITE (SILVER) screws.
- Connect the GROUND wire to the wire terminal with the GREEN grounding screw.
- NOTE: Use caution if you are using a receptacle not rated or recommended for use with this floor box. Follow the wiring directions provided by the receptacle’s manufacturer.
Step 3 – Attach the receptacle and cover plate
- Attach the receptacle to the flange that’s mounted on the floor box.
- Attach the support plate to the receptacle.
- Place the gasket on top of the support plate.
- Attach the cover plate to the flange.
WARRANTY INFORMATION
- This device is warranted to be free of material and workmanship defects for 2 years from the date of purchase.
- An original receipt or proof of purchase from an authorized retailer must be presented upon warranty claim.
- ALL claims must be verified and approved by Enerlites, Inc.
- Warranties from other Enerlites products may vary.
- This warranty is non-transferable and does not cover normal wear and tear or any malfunction, failure, or defect resulting from misuse, abuse, neglect, alteration, modification, or improper installation.
- To the fullest extent permitted by the applicable state law, Enerlites shall not be liable to the purchaser or end-user customer of Enerlites products for direct, indirect, incidental, or consequential damages even if Enerlites has been advised of the possibility of such damages.
- Enerlites’ total liability under this or any other warranty, express or implied, is limited to repair, replacement, or refund.
- Repair, replacement, or refund are the sole and exclusive remedies for breach of warranty or any other legal theory.
CONTACT
- © 2016 Enerlites Inc.
- CA, U.S.A.
- WWW.ENERLITES.COM.
- 0201170074-01
- REV 20230802
- FB-02 Junction Box
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>