Enerlites 975506-C Screw Cap Cover Floor Box kit Instruction Manual
- June 14, 2024
- ENERLITES
Table of Contents
Enerlites 975506-C Screw Cap Cover Floor Box kit
Product Information
Product Name| Single Gang Fixed Floor Box with 20A Duplex Tamper & Weather
Resistant Receptacle
---|---
Model Numbers| 975506-C & 975506-SS / 975507-C & 975507-S
Description / Features| One gang floor box with a tamper & weather resistant
20 amp duplex receptacle, FB-06 box, gasket, and cover
Specifications| In accordance with the National Electric Code and local
regulations. Requires a qualified electrician for installation. Use copper
wire only. Recommended wire size: 10-12 AWG Stranded or Solid Copper.
Warranty Information| Website: www.enerlites.com
Product Usage Instructions
WARNING: Turn the POWER OFF at the circuit breaker before installing the Floor Box.
- Before Installation: Ensure there is sufficient depth & space below the subfloor.
- For carpeted floors: Cut out a section of carpet smaller than the size of the cover.
- Subfloor/Finished Floor Surface
Step 1: Turn off the circuit breaker or fuse(s) and ensure power is off before wiring the device.
Step 2: Wiring Directions
Step | Action |
---|---|
1 | Connect the HOT wire to the BLACK wire. |
2 | Connect the NEUTRAL wire to the WHITE wire. |
3 | Connect the GROUND wire to the GREEN wire on the switch. |
Note: It is recommended to have a qualified electrician perform this installation.
MODELS
SPECIFICATIONS
Cover Material
- 975506 ………………………………………………………………………………..Brass(C) or Stainless Steel(SS)
- 975507 ……………………………………………………………………………Brass(C) or Nickel-Plated Brass(S)
- Receptacle Rating …………………………………………………………………………………………..20A 125VAC
- Box Material ……………………………………………………………………………………………..Galvanized Steel
- Knockout size ……………………………………………………………………………………………………………..1/2″
- Adjustable Height ………………………………………………………………………………………….up to 1″ depth
DESCRIPTION/ FEATURES
Included is a One gang floor box with a tamper & weather resistant 20 amp duplex receptacle, FB-06 box, gasket and cover.
- Compact and stylish design with adjustable height function metal box with the choice of Brass(C) or Nickel-Plated Brass(S).
- Corrosion resistant hardware ensure long life span and reliable performance.
- Easy access to power when you need it.
- Used for carpet and wood floors.
WARNING: Turn the POWER OFF at the circuit breaker before installing the Floor Box.
Read and understand these instructions before installing. This device is intended for installation in accordance with the National Electric Code and local regulations. It is recommended that a qualified electrician performs this installation. Make sure to turn off the circuit breaker or fuse(s) and make sure power is off before wiring the device. Use copper wire only.
NOTES: 10-12 AWG Stranded or Solid Copper wire is recommended.
DIMENSIONS AND INSTALLATION
DIMENSIONS
FLOOR BOX INSTALLATION
Before Installation
- Ensure there is sufficient depth & space below the subfloor.
Step 1: For carpeted floors:
Cut out a section of carpet smaller than the size of the cover.
For wood sub-floors and finished hardwood floors:
- Tape the template on the area you want to place the floor box.
- Use a knife to cut the outline of the box. Start with the ears and move inwards.
- Following the outline, cut the box shape without the ears completely through the sub-floor or hardwood floor.
- Following the outline, cut 3/8″ deep into the sub-floor or hardwood for the mounting ears.
- Using a router is recommended
Step 2
- Remove knockouts and secure the box onto the floor. Pull the wires through the opening of the floor and the knockout and connect the wires based on the wiring diagram.
- Use the proper connector/ clamp at the knockouts to secure the wires and to avoid accidental wire stripping.
- Secure the box to the opening using wood screws.
WIRING DIRECTIONS
- Connect the HOT wire to the BLACK wire.
- Connect the NEUTRAL wire to the WHITE wire.
- Connect the GROUND wire to the GREEN wire on the switch.
WARRANTY INFORMATION
This device is warranted to be free of material and workmanship defects for 2 years from the date of purchase. Original receipt or proof of purchase from an authorized retailer must be presented upon warranty claim. ALL claims must be verified and approved by Enerlites, Inc. Warranties from other Enerlites products may vary. This warranty is nontransferable and does not cover normal wear and tear or any malfunction, failure, or defect resulting from misuse, abuse, neglect, alteration, modification, or improper installation.
To the fullest extent permitted by the applicable state law, Enerlites shall not be liable to the purchaser or end user customer of Enerlites products for direct, indirect, incidental, or consequential damages even if Enerlites has been advised of the possibility of such damages. Enerlites’ total liability under this or any other warranty, express or implied, is limited to repair, replacement or refund. Repair, replacement or refund are the sole and exclusive remedies for breach of warranty or any other legal theory.
© 2016 Enerlites Inc.
CA, U.S.A.
WWW.ENERLITES.COM
0207160035-01
REV 20230802