Enerlites 975547-C Stainless Steel Floor Box w TRWR Single Outlet
Product Information
The product is a Single Gang Floor Box with a tamper-resistant 20A Single Receptacle. It includes an FB-06 box, gasket, and cover plate. The dimensions of the floor box are as follows:
- Overall Dimensions: 4-1/4″ x 3-1/4″ x 2-7/8″ (107.2mm x 83.3mm x 73mm)
- Cover Plate Dimensions: 3-5/16″ x 5″ (83.5mm x 127mm)
- Box Depth: 1-15/16″ (49.2mm)
Product Usage Instructions
- Before Installation:
- Ensure there is sufficient depth and space below the subfloor.
- Step 1: Carpeted Floors
- Cut out a section of carpet smaller than the size of the cover.
- Step 2: Floor Box Installation
- Turn the POWER OFF at the circuit breaker before installing the Floor Box.
- Read and understand the instructions before installing.
- This device is intended for installation by the National Electric Code and local regulations. It is recommended that a qualified electrician perform this installation.
- Make sure to turn off the circuit breaker or fuse(s) and ensure the power is off before wiring the device.
- Use copper wire only.
- Rout 3/8″ (10.16mm) deep for outer tabs.
- Wiring Directions:
- Connect the HOT wire to the BLACK wire.
- Connect the NEUTRAL wire to the WHITE wire.
- Connect the GROUND wire to the GREEN wire.
- Warranty Information
- This device is warranted to be free of material and workmanship defects for 2 years from the date of purchase.
- To claim a warranty, the original receipt or proof of purchase from an authorized retailer must be presented.
- All claims must be verified and approved by Enerlites, Inc.
- This warranty is nontransferable and does not cover normal wear and tear or any malfunction, failure, or defect resulting from misuse, abuse, neglect, alteration, modification, or improper installation.
- Enerlites’ liability is limited to repair, replacement, or refund as the sole and exclusive remedies for breach of warranty or any other legal theory.
- For more information, visit www.enerlites.com
- Product Code: 0309220193
- Revision: 20230802
SPECIFICATIONS
Cover Material
- 975547 ………………………………………………………………………………..Brass(C) or Stainless Steel(SS)
- Receptacle Rating …………………………………………………………………………………………..20A 125VAC
- Box Material ……………………………………………………………………………………………..Galvanized Steel
- Knockout size ……………………………………………………………………………………………………………..1/2″
- Adjustable Height ………………………………………………………………………………………….up to 1″ depth
DESCRIPTION/ FEATURES
Included is a One gang floor box with a tamper-resistant 20 amp single receptacle, FB-06 box, gasket and cover.
- Compact and stylish design with adjustable height function metal box with the choice of Brass(C) or Stainless Steel (SS).
- Corrosion-resistant hardware ensures a long life span and reliable performance. Easy access to power when you need it.
- Used for carpet and wood floors.
WARNING
- Turn the POWER OFF at the circuit breaker before installing the Floor Box.
- Read and understand these instructions before installing.
- This device is intended for installation per the National Electric Code and local regulations.
- It is recommended that a qualified electrician perform this installation.
- Make sure to turn off the circuit breaker or fuse(s) and make sure the power is off before wiring the device. Use copper wire only.
- NOTES: 10-12 AWG Stranded or Solid Copper wire is recommended.
DIMENSIONS
FLOOR BOX INSTALLATION
Before Installation:
- Ensure there is sufficient depth & space below the sub-floor.
Step 1
- For carpeted floors:
- Cut out a section of carpet smaller than the size of the cover.
- For wood sub-floors:
- Tape the template on the area you want to place the floor box.
- Use a knife to cut the outline of the box. Start with the ears and move inwards.
- Following the outline, cut the box shape without the ears completely through the subfloor or hardwood floor.
- Following the outline, cut 3/8″ deep into the subfloor for the mounting ears.
- DO NOT ROUT OUT THE FINISHED FLOOR.
Step 2
- Remove knockouts and secure the box onto the floor. Pull the wires through the opening of the floor and the knockout and connect the wires based on the wiring diagram
- Use the proper connector/ clamp at the knockouts to secure the wires and avoid accidental wire stripping.
- Secure the box to the opening using wood screws.
WIRING DIRECTIONS
- Connect the HOT wire to the BLACK wire.
- Connect the NEUTRAL wire to the WHITE wire.
- Connect the GROUND wire to the GREEN wire.
WARRANTY INFORMATION
- This device is warranted to be free of material and workmanship defects for 2 years from the date of purchase.
- An original receipt or proof of purchase from an authorized retailer must be presented upon warranty claim.
- ALL claims must be verified and approved by Enerlites, Inc.
- Warranties from other Enerlites products may vary.
- This warranty is non-transferable and does not cover normal wear and tear or any malfunction, failure, or defect resulting from misuse, abuse, neglect, alteration, modification, or improper installation.
- To the fullest extent permitted by the applicable state law, Enerlites shall not be liable to the purchaser or end-user customer of Enerlites products for direct, indirect, incidental, or consequential damages even if Enerlites has been advised of the possibility of such damages.
- Enerlites’ total liability under this or any other warranty, express or implied, is limited to repair, replacement, or refund.
- Repair, replacement, or refund are the sole and exclusive remedies for breach of warranty or any other legal theory.
CONTACT
- © 2022 Enerlites Inc.
- CA, U.S.A.
- WWW.ENERLITES.COM.
- 0309220193
- REV 20230802
- 975547-C & 975547-SS
- Single Gang Floor Box with 20A Single
- Tamper Resistant Receptacle
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>