Enerlites 975547-C Single Gang Floor Box with 20A Single Tamper Resistant Receptacle Instruction Manual
- June 14, 2024
- ENERLITES
Table of Contents
Enerlites 975547-C Single Gang Floor Box with 20A Single Tamper Resistant
Receptacle
Product Information
Product Name| Single Gang Floor Box with 20A Single Tamper Resistant
Receptacle
---|---
Model Numbers| 975547-C & 975547-SS
Dimensions| Box: 4-1/4″(107.2mm) x 3-1/4″(83.3mm) x 3-5/16″(83.5mm)
Cover Plate: 3″(76.2mm) x 5″(127mm)
Gasket: 3-1/2″(88.9mm) x 5/8″(15.6mm)
Receptacle: 1-13/16″(46.0mm) x 1-1/8″(28.7mm)
Description/Features| Included is a one-gang floor box with a tamper-resistant
20 amp
single receptacle, FB-06 box, gasket, and cover.
Warranty| This device is warranted to be free of material and workmanship
defects for 2 years from the date of purchase. Original receipt or
proof of purchase from an authorized retailer must be presented
upon warranty claim. This warranty is non-transferable and does not
cover normal wear and tear or any malfunction, failure, or defect
resulting from misuse, abuse, neglect, alteration, modification, or
improper installation.
Product Usage Instructions
- Before Installation:
- Ensure there is sufficient depth & space below the sub-floor.
- Step 1:
- For carpeted floors, cut out a section of carpet smaller than the size of the cover.
- WARNING:
- Turn the POWER OFF at the circuit breaker before installing the Floor Box.
- Read and understand these instructions before installing.
- This device is intended for installation by the National Electric Code and local regulations.
- It is recommended that a qualified electrician perform this installation.
- Make sure to turn off the circuit breaker or fuse(s) and make sure the power is off before wiring the device. Use copper wire only.
- NOTES:
- 10-12 AWG Stranded or Solid Copper wire is recommended.
- Step 2:
- Rout 3/8″(10.16mm) Deep For Outer Tabs
- Wiring Directions:
- Connect the HOT wire to the BLACK wire.
- Connect the NEUTRAL wire to the WHITE wire.
- Connect the GROUND wire to the GREEN wire.
SPECIFICATIONS
Cover Material
- 975547………………………………………………………………………………..Brass(C) or Stainless Steel(SS)
- Receptacle Rating…………………………………………………………………………………………..20A 125VAC
- Box Material……………………………………………………………………………………………..Galvanized Steel
- Knockout size……………………………………………………………………………………………………………..1/2″
- Adjustable Height………………………………………………………………………………………….up to 1″ depth
DESCRIPTION/ FEATURES
Included is a One gang floor box with a tamper-resistant 20 amp single receptacle, FB-06 box, gasket, and cover.
- Compact and stylish design with adjustable height function metal box with the choice of Brass(C) or Stainless Steel (SS).
- Corrosion-resistant hardware ensures a long life span and reliable performance.
- Easy access to power when you need it.
- Used for carpet and wood floors.
WARNING
- Turn the POWER OFF at the circuit breaker before installing the Floor Box.
- Read and understand these instructions before installing.
- This device is intended for installation following the National Electric Code and local regulations.
- It is recommended that a qualified electrician perform this installation.
- Make sure to turn off the circuit breaker or fuse(s) and make sure the power is off before wiring the device. Use copper wire only.
NOTES: 10-12 AWG Stranded or Solid Copper wire is recommended.
DIMENSIONS
FLOOR BOX INSTALLATION
Before Installation:
- Ensure there is sufficient depth & space below the sub-floor.
Step 1
- For carpeted floors:
- Cut out a section of carpet smaller than the size of the cover.
- For wood sub-floors:
- Tape the template on the area you want to place the floor box.
- Use a knife to cut the outline of the box. Start with the ears and move inwards.
- Following the outline, cut the box shape without the ears completely through the subfloor or hardwood floor.
- Following the outline, cut 3/8″ deep into the subfloor for the mounting ears.
- DO NOT ROUT OUT THE FINISHED FLOOR.
- Step 2
- Remove knockouts and secure the box onto the floor. Pull the wires through the opening of the floor and the knockout and connect the wires based on the wiring diagram.
- Use the proper connector/ clamp at the knockouts to secure the wires and to avoid accidental wire stripping.
- Secure the box to the opening using wood screws.
WIRING DIRECTIONS
- Connect the HOT wire to the BLACK wire.
- Connect the NEUTRAL wire to the WHITE wire.
- Connect the GROUND wire to the GREEN wire.
WARRANTY INFORMATION
- This device is warranted to be free of material and workmanship defects for 2 years from the date of purchase.
- An original receipt or proof of purchase from an authorized retailer must be presented upon warranty claim.
- ALL claims must be verified and approved by Enerlites, Inc.
- Warranties from other Enerlites products may vary.
- This warranty is non-transferable and does not cover normal wear and tear or any malfunction, failure, or defect resulting from misuse, abuse, neglect, alteration, modification, or improper installation.
- To the fullest extent permitted by the applicable state law, Enerlites shall not be liable to the purchaser or end-user customer of Enerlites products for direct, indirect, incidental, or consequential damages even if Enerlites has been advised of the possibility of such damages.
- Enerlites’ total liability under this or any other warranty, express or implied, is limited to repair, replacement, or refund.
- Repair, replacement, or refund are the sole and exclusive remedies for breach of warranty or any other legal theory.
CONTACT
- © 2022 Enerlites Inc.
- CA, U.S.A.
- WWW.ENERLITES.COM.
- 0309220193
- REV 20230802
- 975547-C & 975547-SS
- Single Gang Floor Box with 20A Single
- Tamper Resistant Receptacle
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>