ENERLITES 975517-C 5-3/4 Inch Dia Flush Round Flip Lid Cover Plate Instruction Manual

June 14, 2024
ENERLITES

Enerlites-logo

ENERLITES 975517-C 5-3/4 Inch Dia Flush Round Flip Lid Cover Plate

Product Information

  • Product Diameter:
    • The product is a 5-3/4 inch diameter flush round flip lid cover plate with a 20A duplex tamper & weather-resistant receptacle. It includes one 20 amp duplex tamper & weather-resistant receptacle, a gasket, and a cover plate.
  • Specifications:
    • Product Model: 975517-C / 975517-S
    • Product Diameter: 5-3/4 inches (146mm)
    • Receptacle Type: Duplex Tamper & Weather Resistant
    • Receptacle Amperage: 20A

Product Usage Instructions

  1. Before Installation: Ensure that there is sufficient depth and space below the subfloor.

  2. Trace the outline of the box on the subfloor.

  3. Following the outline cut the box shape without the ears completely through the subfloor.

  4. Remove knockout(s) for cables and use cable clamps or grommets
    to secure wires to the metal box.

  5. Secure the metal box to framing using wood screws.

  6. Follow the wiring directions:

    • Insert wire(s) through terminal holes in the back of the receptacle.
    • Tighten terminal screws to secure the wires.
    • Connect the wires to the appropriate terminals on the receptacle:
    • Ground (Green or bare wire)
    • Neutral (White wire)
    • Hot (Black wire)
  7. Secure the receptacle to the metal box.

  8. Install the cover plate using the provided screws.

  9. Ensure to read and understand these instructions before installing.

  10. Make sure to turn off the power at the circuit breaker or fuse(s) before wiring the device.

  11. Use copper wire ONLY.

Note: The metal box (FB-02) is sold separately and may be required for installation. For any further assistance or inquiries, refer to the product manual or contact our customer support.

SPECIFICATIONS

  • Cover Material Brass (C) or Nickel-Plated Brass(S)
  • Receptacle Rating 20A 125VAC
  • Box Material Galvanized Steel
  • Knockout size 1/2″ and 3/4″
  • Adjustable Height up to 1″ depth

DESCRIPTION/ FEATURES

  • Flush round flip lid cover plate with duplex tamper & weather resistant receptacle.
  • Includes one 20 amp duplex tamper & weather-resistant receptacle, gasket, and cover.
  • Compact and stylish design in Brass(C) or Nickel-Plated Brass(S). The height of the metal box is adjustable for ease of installation.
  • Corrosion-resistant hardware ensures a long life span and reliable performance. Easy access to power when you need it. Close and lock the cover when not in use.

WARNING

  • Turn the POWER OFF at the circuit breaker before installing the Floor Box
  • Read and understand these instructions before installing.
  • This device is intended for installation per the National Electric Code and local regulations. It is recommended that a qualified electrician perform this installation.
  • Make sure to turn off the circuit breaker or fuse(s) and make sure the power is off before wiring the device. Use copper wire ONLY.
    • NOTES: 10-12 AWG Stranded or Solid Copper wire is recommended.

DIMENSION

FLOOR BOX INSTALLATION

Before Installation: Ensure there is sufficient depth & space below the sub-floor.

  1. Trace the outline of the box on the subfloor.
  2. Following the outline cut the box shape without the ears completely through the sub-floor
  3. Remove knockout(s) for cables and use cable clamps or grommets to secure wires to the metal box.
  4. Secure the metal box to framing using wood screws.
  5. Follow the wiring directions and connect the wires to the appropriate terminals on the receptacle.
  6. Secure the receptacle to the metal box and install the cover using provided screws.

WIRING DIRECTIONS

Insert wire(s) through terminal holes in the back, then tighten terminal screws.

  • Connect the HOT wire to the HOT terminal (brass screw).
  • Connect the NEUTRAL wire to the NEUTRAL terminal (silver screw).
  • Connect a GREEN or BARE wire to the GROUND terminal (green screw).

WARRANTY INFORMATION

  • This device is warranted to be free of material and workmanship defects for 2 years from the date of purchase.
  • An original receipt or proof of purchase from an authorized retailer must be presented upon warranty claim.
  • ALL  claims must be verified and approved by Enerlites, Inc.
  • Warranties from other Enerlites products may vary.
  • This warranty is non-transferable and does not cover normal wear and tear or any malfunction, failure, or defect resulting from misuse, abuse, neglect, alteration, modification, or improper installation.
  • To the fullest extent permitted by the applicable state law, Enerlites shall not be liable to the purchaser or end-user customer of Enerlites products for direct, indirect, incidental, or consequential damages even if Enerlites has been advised of the possibility of such damages.
  • Enerlites’ total liability under this or any other warranty, express or implied, is limited to repair, replacement, or refund. Repair, replacement, or refund are the sole and exclusive remedies for breach of warranty or any other legal theory.

CONTACT

  • © 2016 Enerlites Inc.
  • CA, U.S.A.
  • WWW.ENERLITES.COM.
  • 0212160071-01
  • REV 20230802
  • 975517-C / 975517-S
  • 5-314″ Dia. Flush Round Flip Lid Cover Plate
  • with 20A Duplex Tamper & Weather Resistant Receptacle

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

ENERLITES User Manuals

Related Manuals