Enerlites 58300 LED/CFL Add On Remote Dimmer Switch Instruction Manual

June 14, 2024
ENERLITES

Enerlites 58300 LED/CFL Add On Remote Dimmer Switch

Product Information

The 58300 Single Pole/3-Way Dimmer Switch is a high-quality electrical device designed for controlling the brightness of lights. It is built to meet the specifications of the National Electric Code and local regulations. The dimmer switch features a paddle for easy operation and is compatible with various types of bulbs, including LED, CFL, Incandescent, and Halogen.

Specifications

  • Model Number: 58300
  • Switch Type: Single Pole/3-Way
  • Maximum Load Capacity: 150W for LED/CFL bulbs, 600W for Incandescent/Halogen bulbs
  • Warranty: For warranty information, please visit www.enerlites.com

Features

  • Easy-to-use paddle for adjusting the brightness
  • Can be installed as a single pole or in a 3-way configuration
  • Supports various types of bulbs, including LED, CFL, Incandescent, and Halogen
  • Designed to meet electrical safety standards

Product Usage Instructions

  1. Before installing the dimmer switch, turn off the power at the circuit breaker.

  2. Read and understand the installation instructions provided.

  3. It is recommended to have a qualified electrician perform the installation.

  4. Use copper wire for all connections.

  5. Single-Pole Wiring:

  6. Connect the HOT wire to the Hot terminal on the switch.

  7. Connect the NEUTRAL wire to the Neutral terminal on the switch.

  8. Connect the LOAD wire to the Load terminal on the switch.

  9. Connect the GROUND wire to the Ground terminal on the switch.

  10. Mount the dimmer to the electrical box with the Top indicator pointing up.

  11. Turn on the Circuit Breaker.

  12. 3-Way Wiring with 58300-3K remote dimmer:

  13. Connect the HOT wire to the Hot terminal on the switch.

  14. Connect the NEUTRAL wire to the Neutral terminal on the switch.

  15. Connect the TRAVELER wire to the Traveler terminal on the switch.

  16. Connect the LOAD wire to the Load terminal on the switch.

  17. Mount the dimmer to the electrical box with the Top indicator pointing up.

  18. Turn on the Circuit Breaker.

  19. Multigang Installation:
    If installing multiple dimmer switches in the same wall box:

  20. Remove the side tabs from each dimmer switch using pliers.

  21. Bend each tab back and forth until they break off.

  22. Repeat for each tab to be removed.

  23. Note that removing tabs will reduce the maximum load capacity. Refer to the LED/CFL Derating Chart for specific capacities.

  24. LED/CFL Derating Chart:
    Use this chart to determine the maximum load capacity when controlling LED/CFL and Incandescent/Halogen bulbs together:Combined Wattage of ALL LED/CFL bulbs on 1 dimmer| Maximum Combined Wattage for Incandescent/Halogen bulbs on EACH
    attached dimmer
    ---|---
    0W| 600W
    1-25W| 500W
    26-50W| 400W
    51-75W| 300W
    76-100W| 200W
    101-125W| 100W
    126-150W| 50W

If you are using ONLY LED/CFL bulbs on ALL dimmers, do not use this derating chart. Follow the LED/CFL Derating Chart provided.

Note: For any warranty-related information, please visit the official website at www.enerlites.com.

SPECIFICATIONS

  • Voltage ………………………………………………………………………….120VAC, 60Hz
  • Incandescent/ Halogen………………………………………………………………….600W
  • Dimmable LED and Dimmable CFL…………………………………………………150W
  • Operating Temperature………………………………………………………….32°F-104°F

DESCRIPTION/FEATURES

The 58300 is an Incandescent/Halogen, LED & CFL dimmer. By itself, the 58300 is a single pole dimmer. Our unique wiring method allows for multiple switches (requires 58300-3K) to control a single Load at multiple locations

  • Replaces current light switch using home’s existing wiring
  • Provides wider dimming range for dimmable LED and CFL bulbs than standard incandescent dimmers
  • Suitable for multi-gang installations
  • Dim lighting for increased energy savings
  • Designed for compatibility with most high efficiency light bulbs.

OPERATIONS

Manual Control

This dimmer switch allows the user to:
Turn ON/OFF and control the brightness level of the connected LED lighting.

  • Slide the power switch to turn the connected lights ON/OFF
  • To turn ON the connected lighting: press top of the dimmer switch paddle and release.
  • To brighten the connected lighting: press and hold the top of the dimmer switch paddle, release when desired level is achieved.
  • To turn OFF the connected lighting: press bottom of the dimmer switch paddle and release.
  • To dim the connected lighting: press and hold the bottom of the dimmer switch paddle, release when desired level is achieved.
  • Slide the Power Switch to OFF position for bulb replacement.

WARNING

  • Turn the POWER OFF at the circuit breaker before installing the Dimmer
  • Read and understand these instructions before installing. This device is intended for installation in accordance with the National Electric Code and local regulations. It is recommended that a qualified electrician performs this installation.

Use copper wire only

WIRING DIRECTIONS

  1. Connect the HOT wire to the Hot terminal on the switch.
  2. Connect the NEUTRAL wire to the Neutral terminal on the switch.
  3. Connect the LOAD wire to the Load terminal on the switch.
  4. Connect GROUND wire to Ground terminal wire on the switch.
  5. Mount the dimmer to the box with “Top” indicator pointing up.
  6. Turn on Circuit Breaker.

Single-Pole Wiring

3-Way Wiring with 58300-3K remote dimmer

  1. Connect the HOT wire to the Hot terminal on the dimmer switch.
  2. Connect the NEUTRAL wire to the Neutral terminal on each switch.
  3. Connect the TRAVELER A wire to the Traveler terminal on the 3K switch.
  4. Connect the TRAVELER B to the existing Load wire, Traveler B is now Load.
  5. Connect the TRAVELER B wire the Load terminal on the dimmer switch.
  6. Connect the GROUND wire to Ground terminal on each switch.
  7. Mount the dimmer to the box with “Top” indicator pointing up.
  8. Turn on Circuit Breaker.

MULTIGANG INSTALLATION

When installing more than one control in the same wall box, it may be necessary to remove the side tabs before installing (see below). Using pliers, bend each tab back and forth until they break off. Repeat for each tab to be removed. Removal of tabs WILL REDUCE MAXIMUM LOAD CAPACITY.

LED/CFL Derating Chart

 | Load Capacity when Tabs are removed from:
Dimmable LED/CFL| 0 Sides| 1 Side| 2 Sides
150W| 150W| 150W

When using the Dimmer to control LED/CFL lights in conjunction with another Dimmer to control Incandescent /Halogen lights follow this Derating Chart for Maximum Capacitiy on EACH device.

If the combined Wattage of ALL LED/CFL bulbs on 1 dimmer is:| Then the Maximum COMBINED Wattaged for the Incandescent/Halogen bulbs on EACH attached dimmer:
---|---
If NO Tabs are removed then Max Wattage is:| If 1 side of Tabs are removed then Max Wattage is:| If 2 sides of Tabs are removed then Max Wattage is:
0W| 600W| 500W| 400W
1-25W| 500W| 400W| 300W
26-50W| 400W| 300W| 200W
51-75W| 300W| 200W| 100W
76-100W| 200W| 100W| 50W
101-125W| 100W| 50W| 0W
126-150W| 0W| 0W| 0W

If you are using ONLY LED/CFL bulbs on ALL Dimmers, DO NOT USE this Derating Chart. Follow the LED/ CFL Derating Chart.

WARRANTY INFORMATION

This device is warranted to be free of material and workmanship defects for 1 years from the date of purchase. Original receipt or proof of purchase from an authorized retailer must be presented upon warranty claim. ALL claims must be verified and approved by Enerlites, Inc. Warranties from other Enerlites products may vary. This warranty is nontransferable and does not cover normal wear and tear or any malfunction, failure, or defect resulting from misuse, abuse, neglect, alteration, modification, or improper installation. To the fullest extent permitted by the applicable state law, Enerlites shall not be liable to the purchaser or end user customer of Enerlites products for direct, indirect, incidental, or consequential damages even if Enerlites has been advised of the possibility of such damages. Enerlites’ total liability under this or any other warranty, express or implied, is limited to repair, replacement or refund. Repair, replac-ement or refund are the sole and exclusive remedies for breach of warranty or any other legal theory.

© 2023 Enerlites Inc. CA, U.S.A.

REV 20230802

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

ENERLITES User Manuals