Enerlites IUC1HV-D Extra Duty Weatherproof Outdoor Mount Cover Instruction Manual

June 14, 2024
ENERLITES

Enerlites IUC1HV-D Extra Duty Weatherproof Outdoor Mount Cover

Product Information

  • Product Name: IUC1HV-D In-Use Weatherproof Enclosure.
  • Product Description: This Gang In-Use Horizontal/Vertical Weatherproof Enclosure is designed for outdoor or wet locations. It is built to withstand any season and provides protection for receptacles while in use for unattended applications.
  • The enclosure is UL-listed, NEMA 3R rated, and meets National Electrical Code requirements covered by Article 410-57(b) and NEC-210-60(b).

Specifications:

  • Receptacle Rating: 15-20A 125 to 250VAC
  • Receptacle Type: Decorator GFCI Type
  • Dimensions: 6.42″ x 3.52″ x 2.89″

Features:

  • Weatherproof and durable design
  • Suitable for outdoor and wet locations
  • Protects receptacles while in use
  • UL Listed and NEMA 3R rated

Product Usage Instructions

  1. Disconnect power to the receptacle at the circuit breaker panel before installing.
  2. If installing on an existing receptacle, remove and discard the existing cover, plate, and gasket.
  3. Position the gasket as required after removing the appropriate perforated sections. It can be temporarily held onto the back of the base using the mounting hardware provided.
  4. Align the receptacle and support bracket with the junction box, then attach the assembly to the junction box using the screws provided. Ensure that the hinges are located at the top for weatherproof protection. If mounting to an outdoor junction box, use the remaining screws to further secure the base assembly to the junction box. For specially designed junction boxes, drill mounting holes to line up with the hole in the box.
  5. Ensure all screws are firmly secured but not over-tightened.
  6. Depending on the position of the enclosure, for power cord placement, remove the two plastic fillers from the horizontal mount and place them into the vertical mount or vice versa.
  7. To open, bend back the plastic latch while lifting the cover. A hasp is provided for padlocking.

Warranty Information: This product is covered by a warranty from Enerlites Inc. Please refer to their website for more details: www.enerlites.com

SPECIFICATIONS

  • Receptacle Rating ………………………………………………………15-20A 125 to 250VAC
  • Receptacle Type ………………………………………………………….Decorator GFCI Type
  • Length x Width x Depth.. ………………………………………………….6.42″ x 3.52″ x 2.89″

DESCRIPTION

  • This One Gang In-Use Horizontal/Vertical Weatherproof Enclosure can be used outdoors or in other wet locations and is designed to withstand the elements, any season, rain, or shine (protects receptacles while in use for unattended applications).
  • It’s UL-listed, NEMA 3R rated and meets National Electrical Code requirements covered by Article 410-57(b) and designed to meet NEC-210-60(b).

FEATURES

  • Polycarbonate construction provides maximum durability
  • Single gang NEMA 3R decorator/GFCI cover
  • Includes high-quality gasket and mounting hardware
  • Horizontal or Vertical mount
  • Extra duty
  • Lockable tap

WARNING

  • Turn the POWER OFF at the circuit breaker before installing the receptacle.
  • Read and understand these instructions before installing. This device is intended for installation in accordance with the National Electric Code and local regulations. It is recommended that a qualified electrician perform this installation. Make sure to turn off the circuit breaker or fuse(s) and make sure the power is off before wiring the device

INSTALLATION DIRECTIONS

  1. Disconnect power to the receptacle at the circuit breaker panel before installing.
  2. If installing on an existing receptacle, remove and discard the existing cover, plate, and gasket.
  3. Position the gasket as required after removing the appropriate perforated sections. It can be temporarily held onto the back of the base using the mounting hardware provided.
  4. Align the receptacle and support bracket with the junction box then attach the assembly to the junction box using the screws provided. To ensure weatherproof protection, the hinges must be located at the top. If mounting to an outdoor junction box, use the remaining screws to further secure the base assembly to the junction box. For specially designed junction boxes, mounting holes should be drilled to line up with the hole in the box.
  5. Be sure all screws are firmly secured but not over-tightened.
  6. Depending on the position of the enclosure, for power cord placement remove the two plastic fillers from the horizontal mount and place them into the vertical mount or vice versa.
  7. To open, bend back the plastic latch while lifting the cover, a hasp is provided for padlocking.

Horizontal Mount

Vertical Mount

WARRANTY INFORMATION

This device is warranted to be free of material and workmanship defects for 1 year from the date of purchase. An original receipt or proof of purchase from an authorized retailer must be presented upon warranty claim. ALL claims must be verified and approved by Enerlites, Inc. Warranties from other Enerlites products may vary. This warranty is non-transferable and does not cover normal wear and tear or any malfunction, failure, or defect resulting from misuse, abuse, neglect, alteration, modification, or improper installation. To the fullest extent permitted by the applicable state law, Enerlites shall not be liable to the purchaser or end-user customer of Enerlites products for direct, indirect, incidental, or consequential damages even if Enerlites has been advised of the possibility of such damages. Enerlites’ total liability under this or any other warranty, express or implied, is limited to repair, replacement, or refund. Repair, replacement, or refund are the sole and exclusive remedies for breach of warranty or any other legal theory.