Welcome to the advanced world of electrical safety and convenience with the 3GRACE GFITR-20A Tamper-Resistant GFI Receptacle. This user manual is designed to guide you through the installation, operation, and maintenance of this tamper-resistant ground fault circuit interrupter (GFI) receptacle, ensuring a secure and efficient electrical experience.

Specifications

  • Model: 3GRACE GFITR-20A
  • Voltage: 125V
  • Amperage: 20A
  • Type: Tamper-Resistant GFI Receptacle
  • Weather Resistance: Suitable for indoor use
  • Termination: Side or bank wire
  • Certifications: UL listed

What’s in the Box

  1. 3GRACE GFITR-20A Tamper-Resistant GFI Receptacle
  2. Wall plate
  3. Mounting screws
  4. Installation instructions

Key Features

  1. Tamper-Resistant Design:
    • Prevents the insertion of foreign objects, ensuring safety for users, especially in households with children.
  2. Ground Fault Circuit Interrupter::
    • Provides advanced protection against electric shocks by quickly disconnecting power in the event of a ground fault.
  3. 20A Amperage:
    • Supports devices with higher power requirements, making it suitable for various applications.
  4. Versatile Termination:
    • Accommodates both side and back wire termination for installation flexibility.
  5. Sleek Aesthetic:
    • Designed with a modern and sleek appearance to complement different decors.

3GRACE-GFITR-20A-Tamper-Resistant-GFI-Receptacle-fig-1

How to Use

  1. Power Off:
    • Turn off the power at the circuit breaker before installation.
  2. Installation:
    • Follow the provided installation instructions carefully.
    • Connect wires securely using the chosen termination method (side or back wire).
  3. Testing:
    • After installation, perform a functional test by pressing the “Test” button to ensure proper GFI operation.
    • Reset the receptacle by pressing the “Reset” button after testing.
  4. Usage:
    • Connect devices to the receptacle and use as you would a standard outlet.

3GRACE-GFITR-20A-Tamper-Resistant-GFI-Receptacle-fig-2

Safety Precautions

  1. Professional Installation:
    • Installation of the 3GRACE GFITR-20A Tamper-Resistant GFI Receptacle should be carried out by a qualified electrician or a professional installer.
    • Always adhere to local electrical codes and regulations during installation.
  2. Power Off During Installation:
    • Turn off the power at the circuit breaker before attempting any installation or maintenance work.
    • Verify that the power is off using a voltage tester before proceeding.
  3. Tamper-Resistant Design:
    • Do not attempt to modify or disable the tamper-resistant feature of the receptacle.
    • The tamper-resistant design is intended to prevent the insertion of foreign objects and enhance overall safety.
  4. Weatherproof Installation:
    • If used outdoors, ensure the receptacle is installed in a weatherproof electrical box to protect it from environmental elements.
    • Seal all entry points to prevent water ingress and maintain weather-resistant properties.
  5. Grounding:
    • Connect the grounding wire in accordance with the manufacturer’s instructions and local electrical codes.
    • Proper grounding is essential for the safe operation of the receptacle.
  6. Regular Inspections:
    • Periodically inspect the receptacle for signs of wear, damage, or corrosion.
    • Replace any damaged or worn components promptly to maintain safety.
  7. GFI Functionality:
    • Test the Ground Fault Circuit Interrupter (GFI) functionality on a regular basis by pressing the “Test” button.
    • Reset the GFI by pressing the “Reset” button after testing.
  8. Load Limits:
    • Adhere to the specified load limits to prevent overheating and potential hazards.
    • Consult the product documentation for information on the maximum allowable current and wattage.

Dimension

3GRACE-GFITR-20A-Tamper-Resistant-GFI-Receptacle-fig-3

Maintenance

  • Visual Inspection:
    • Periodically inspect the 3GRACE GFITR-20A Tamper-Resistant GFI Receptacle for any signs of damage, wear, or discoloration.
    • Ensure there are no visible cracks, loose components, or exposed wiring.
  • Functionality Check:
    • Test the Ground Fault Circuit Interrupter (GFI) functionality regularly by pressing the “Test” button.
    • After testing, reset the GFI by pressing the “Reset” button.
  • Cleaning:
    • Clean the receptacle with a dry or slightly damp cloth to remove dust and debris.
    • Avoid using abrasive cleaners, as they can damage the surface.
  • Tighten Connections:
    • Periodically check the terminal screws for tightness.
    • If any screws are loose, tighten them to ensure a secure electrical connection.
  • Tamper-Resistant Mechanism:
    • Verify that the tamper-resistant mechanism is functioning correctly.
    • Ensure that the shutters cover the receptacle openings and only allow the insertion of a proper plug.
  • Weather Resistance:
    • If installed in an outdoor or damp environment, make sure the weatherproofing remains intact.
    • Check for any signs of water ingress or corrosion.
  • Inspect Labeling:
    • Ensure that all labeling on the receptacle, including voltage ratings and safety information, is legible and in good condition.

3GRACE-GFITR-20A-Tamper-Resistant-GFI-Receptacle-fig-4

Troubleshooting

  1. No Power Output:
    • Check Circuit Breaker: Ensure that the circuit breaker associated with the GFI receptacle is not tripped. Reset the breaker if necessary.
    • Test Other Devices: Plug another device into the receptacle to confirm whether the issue is with the receptacle or the connected device.
  2. GFI Keeps Tripping:
    • Ground Fault Issues: If the GFI receptacle repeatedly trips, it may indicate a ground fault. Inspect connected devices and wiring for potential faults.
    • Moisture or Water Intrusion: Check for any signs of moisture or water near the receptacle. Water ingress can trigger the GFI. Ensure the receptacle and its surroundings are dry.
  3. Tamper-Resistant Shutters Not Opening:
    • Proper Insertion: Ensure that plugs are being inserted correctly and evenly to open the tamper-resistant shutters. Misaligned or damaged plugs may hinder proper operation.
    • Tampering Prevention: The tamper-resistant design might require firm and direct insertion to open the shutters. If tampering is suspected, check for any foreign objects obstructing the receptacle.
  4. Faulty Reset Button:
    • Press Firmly: When attempting to reset the GFI, press the “Reset” button firmly. If the button feels loose or unresponsive, it may indicate a faulty mechanism.
    • Replace if Necessary: If the “Reset” button remains unresponsive, consider replacing the GFI receptacle to ensure continued safety.
  5. Intermittent Power Loss:
    • Wiring Inspection: Inspect the wiring connected to the GFI receptacle for any signs of wear, damage, or loose connections. Address any issues found during the inspection.
    • Temperature Consideration: Extreme temperatures can affect electrical components. If the GFI receptacle is exposed to harsh weather conditions, consider installing weatherproof covers or enclosures.
  6. Inconsistent GFI Functionality:
    • Regular Testing: Periodically test the GFI functionality by pressing the “Test” button. If inconsistent results are observed, the GFI receptacle may be malfunctioning.
    • Professional Inspection: If unsure, consult with a qualified electrician to inspect and, if necessary, replace the GFI receptacle.

FAQs

What is the 3GRACE GFITR-20A Tamper-Resistant GFI Receptacle?

The 3GRACE GFITR-20A is a Tamper-Resistant Ground Fault Circuit Interrupter (GFCI) receptacle designed to enhance electrical safety in homes and commercial spaces. It provides protection against electrical shocks and is commonly used in areas where water and electricity may come into contact.

How does the 3GRACE GFITR-20A GFI Receptacle work?

The 3GRACE GFITR-20A works by constantly monitoring the electrical current flowing in the circuit. If it detects a mismatch in the current, indicating a potential ground fault or electrical leakage, it quickly interrupts the power supply to prevent electric shocks and protect individuals and equipment.

Is the 3GRACE GFITR-20A suitable for residential use?

Yes, the 3GRACE GFITR-20A is suitable for residential use and is commonly installed in kitchens, bathrooms, garages, and outdoor areas where there is a higher risk of electrical hazards.

Can the 3GRACE GFITR-20A be used in commercial and industrial settings?

Yes, the 3GRACE GFITR-20A is designed for versatility and can be used in commercial and industrial settings where electrical safety is a priority.

What is the amperage rating of the 3GRACE GFITR-20A GFI Receptacle?

The 3GRACE GFITR-20A typically has a 20-ampere rating, making it suitable for a variety of electrical applications, including powering appliances and devices with higher power requirements.

Is the 3GRACE GFITR-20A receptacle tamper-resistant?

Yes, the 3GRACE GFITR-20A is tamper-resistant, featuring built-in safety mechanisms to prevent the insertion of foreign objects. This is especially important for households with children to reduce the risk of electrical accidents.

Does the 3GRACE GFITR-20A GFI Receptacle require professional installation?

While it is recommended to have electrical work performed by a licensed professional, the 3GRACE GFITR-20A GFI Receptacle is designed for straightforward installation and comes with installation instructions for those with electrical knowledge.

What color options are available for the 3GRACE GFITR-20A?

The 3GRACE GFITR-20A is often available in various color options, such as white, ivory, or other standard colors, allowing users to choose a receptacle that matches their decor preferences.

Is the 3GRACE GFITR-20A compatible with standard wall plates?

Yes, the 3GRACE GFITR-20A is typically designed to be compatible with standard wall plates, making it easy to integrate into existing electrical installations.

Does the 3GRACE GFITR-20A GFI Receptacle have a reset button?

Yes, the 3GRACE GFITR-20A is equipped with a reset button, allowing users to easily reset the GFCI after it has been tripped due to a ground fault or electrical anomaly.

Can the 3GRACE GFITR-20A be used outdoors?

Yes, the 3GRACE GFITR-20A is often designed to be weather-resistant, allowing it to be used outdoors in areas such as patios, decks, or any location exposed to the elements.

Is the 3GRACE GFITR-20A compatible with aluminum wiring?

It is crucial to check the product specifications and manufacturer recommendations regarding compatibility with aluminum wiring. In some cases, additional considerations or connectors may be required for safe installation.

Can the 3GRACE GFITR-20A GFI Receptacle be used in wet locations?

Yes, the 3GRACE GFITR-20A is often designed for use in wet locations, such as bathrooms and outdoor areas, where water exposure is a concern. Its weather- resistant features enhance its suitability for such environments.

What is the lifespan of the 3GRACE GFITR-20A GFI Receptacle?

The lifespan of the 3GRACE GFITR-20A can vary, but it is generally designed to provide long-lasting performance. Regular maintenance and adherence to manufacturer guidelines can contribute to its durability.

Can the 3GRACE GFITR-20A be installed in older homes?

Yes, the 3GRACE GFITR-20A can be installed in older homes, but it's essential to ensure compatibility with the existing electrical system. Professional assessment and installation may be necessary in some cases.

Is the 3GRACE GFITR-20A GFI Receptacle compliant with safety standards?

Yes, the 3GRACE GFITR-20A is typically designed to meet or exceed relevant safety standards, ensuring that it provides reliable protection against electrical hazards.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals