YIS Marine AOS3066A 6P Membrane Control Panel With Backlight Module And APP Control Instruction Manual

June 14, 2024
YIS Marine

AOS3066A 6P Membrane Control Panel With Backlight Module And APP Control

Product Information:

The 6P Membrane Control Panel with Backlight Module and APP
Control is an ultra-compact panel that is 60% smaller than
traditional panels. It features a PET membrane touch panel
faceplate and has built-in resettable fuses for circuit protection.
Each branch of the panel has a 10A self-resettable fuse. The panel
also has an ON-indication LED and a backlight module for easy
operation in darkness. It has a very low standby current and is
programmed to be momentary, making it ideal for horn or wiper
applications. The package includes a set of 60 assorted graphic and
text label stickers.

The panel has the following specifications:

  • Panel Rating: Max Cumulative Amp – 35A
  • Voltage Rating: DC 11 – 30V
  • Notes: IP66 (Membrane Panel)
  • Power Terminals: M4 stud size Ring terminals
  • Load Terminals: .250 Quick Terminals (Male)

Product Usage Instructions:

  1. Place the provided template on the desired panel position on
    the dashboard and cut a hole accordingly.

  2. From the back of the dashboard, insert the micro USB plug to
    the front and connect it to the socket at the back of the
    panel.

  3. Mount the panel firmly onto the dashboard using the
    self-adhesive on the back.

  4. Install the Control Box properly using the included
    screws.

  5. Insert the other end of the micro USB cable into the Control
    Box and squeeze the cable into the strain relief hook.

  6. Crimp the DC positive wire (+) with the included round
    terminal, pass it through the included insulator, and connect it to
    the screw terminals. Cover the terminals with the insulator
    properly.

  7. Crimp the DC negative wire (-) with the insulated 0.250 female
    terminal and insert it into the negative quick terminal on the
    Control Box.

  8. Connect the load terminals to the desired devices. The numbers
    on top of the load terminals correspond to the numbers on the
    membrane touch panel.

  9. To set up a specific button to be momentary (Push-On), press
    and hold the backlight button to enter setup mode. The white
    backlights will blink. Press the desired button to enable momentary
    function on it, press again to disable. The ON-indication LED will
    blink for Momentary buttons and stay ON for normal buttons during
    setup mode. Release the backlight button to exit setup mode.

  10. To pair with your cellphone, follow the instructions provided
    on the back side of the panel.

6P Membrane Control Panel with Backlight Module and APP Control

Installation Instructions

1 1

91

Place the template provided on the

desired panel position and cut the

hole accordingly.

7 5 37.50

2

Cut hole here

3

ø15

Panel position

Dashboard

4

2

To power source
1 Membrane Control Panel 2 Backlight ON/OFF Switch 3 Micro USB Cable 4 Remote Control Box

Terminals to the devices

Panel back

From the back of dashboard, insert the micro USB plug to the front. Connect the micro USB plug to the socket to the back of panel.

Dashboard

Features

3

Ultra Compact panel size (60% smaller than traditional

panels)

Easy to install ­ no mounting depth, minimum hole drilling

Flexible wiring ­ Control Relay Box installed 1m away from

the touch panel

IP67 ­ protection against strong water jets (Panel Only)

ON-indication LED / 10A Self-resettable fuse for each branch 4

Backlight module allowing easy operation in darkness

Very low standby current

Programmable momentary button ­ all buttons can be

programmed to be momentary (ideal for horn or wiper

applications)

60pcs Assorted Graphic and Text labels stickers set included

Specifications

Faceplate | PET membrane touch panel

Circuit Protection | Built-in Resettable Fuse (PPTC)

Switch Ratings | 10A per branch

5

Panel Rating | Max Cumulative Amp: 35A

Voltage Rating | DC 11 – 30V

Notes | IP66 (Membrane Panel)

Power Terminals | M4 stud size Ring terminals

Load Terminals | .250 Quick Terminals (Male)

Actual Panel Size

Cut hole here

to Device #1~#6
123 456

Mount the panel firmly onto the dashboard with self-adhesive in the back.
Install the Control Box properly with the included screws.
Insert the other end of the micro USB cable into the Control Box. Squeeze the cable into the strain relief hook on the box as illustrated.
Crimp the DC positive wire (+) with the included round terminal. Pass the wire through the included insulator and connect to the screw terminals. Cover the terminals with the insulator properly. Crimp the DC negative wire (-) with the insulated 0.250″ female terminal and insert into the negative quick terminal on Control Box.
Connect the load terminals to the desired devices.The numbers on top of the load terminals correspond to the numbers on the membrane touch panel as shown in the left.

6
2. Press desired button to setup

123

This template is provided to help you install the membrane panel correctly. Cut out template and trace onto the dashboard. Then drill a hole at the shielded area.

456

1. Press and hold

*All buttons can be set to be momentary; only 1 momentary button can be pressed at the same time.

(See back side for instruction to pair with your cellphone)

(Momentary Button Set-up) To set up a specific button to be momentary (Push- On), press and hold the backlight button to enter setup mode (white backlights will be blinking). Press the desired button to enable momentary function on it, press again to disable. The ON-indicatigon LED will be blinking for Momentary buttons and stays ON for normal buttons during setup mode. Release the backlight button to exit setup mode.
2 0 22.03.R e v.0

How to Pair

1

2

My Control Panel

DOWNLOAD APK

ON

ON
GPS

3

4

5

Password: 0000

1 Buttons #1~#6 (Customizable in Settings)
1
2 Switching between different control boxes
3 Current device | Connection Status
4 System voltage monitor
5 Settings

2

CH9141BLE2U | Connected

DC 12.4V

3

4

5

2 0 22.03.R e v.0

FCC Warning Statement
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: — Reorient or relocate the receiving antenna. — Increase the separation between the equipment and receiver. — Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. — Consult the dealer or an experienced radio/TV technician for help.
FCC Radiation Exposure Statement The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located for operating in conjunction with any other antenna or transmitter.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2)This device must accept any interference received, including interference that may cause undesired operation.