REGENCY B41XTCE-NG11 Traditional Gas Fireplace Instruction Manual

June 14, 2024
Regency

REGENCY B41XTCE-NG11 Traditional Gas Fireplace

Bellavista B41XTCE Gas Fireplace

The Bellavista B41XTCE Gas Fireplace is a high-quality and efficient fireplace designed to provide warmth and ambiance to any living space. With its sleek and modern design, this fireplace is not only functional but also adds a touch of elegance to your home.

Product Features

  • Direct Vent System – The fireplace is equipped with a direct vent system, ensuring safe and efficient operation by drawing air for combustion from outside and expelling the combustion gases outdoors.
  • Hot Glass Protection – A barrier is provided with the appliance to reduce the risk of burns from the hot viewing glass. It is essential to install this barrier to protect children and individuals at risk.
  • Proflame I Remote Receiver – The fireplace comes with a Proflame I remote receiver, allowing convenient control of flame height, temperature, and other settings.
  • Gas Type – The appliance is designed for use with a specific type of gas as indicated on the rating plate. It is not convertible for use with other gases.

Product Usage Instructions

  1. Warning: To prevent serious injury, death, or property damage, it is crucial to follow the safety warnings provided in the user manual strictly.
  2. Hot Glass Warning: The glass of the fireplace gets extremely hot during operation. Do not touch the glass until it has cooled down completely. Keep children away from the glass at all times.
  3. Avoid Burns: The fireplace generates intense heat while in operation. Do not touch any part of the appliance, as severe burns may result. Keep children, clothing, furniture, gasoline, and any other flammable liquids away from the fireplace.
  4. Cleaning and Maintenance: Keep the burner and control compartment of the fireplace clean to ensure optimal performance. Refer to the installation and operating instructions accompanying the appliance for detailed cleaning and maintenance guidelines.
  5. Installation: The installation of the Bellavista B41XTCE Gas Fireplace must be carried out in accordance with the manufacturer’s installation instructions and local codes, if any. If there are no local codes, follow the current National Fuel Gas Code (ANSI Z223.1) and the current National Electrical Code (ANSI/NFPA 70) in the U.S.A., or the current CSA B149.1 Gas Installation Code and the current Canadian Electrical Code (CSA C22.1) in Canada.
  6. Mobile/Manufactured Homes: If installing the fireplace in a mobile/manufactured home, it must comply with the Manufactured Home Construction and Safety Standard (Title 24 CFR, Part 3280) or the current Standard of Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities (ANSI/NFPA 501A). Additionally, follow the CAN/CSA Z240-MH Mobile Home Standard in Canada.
  7. Grounding: The appliance must be electrically grounded according to local codes or, in the absence of local codes, with the National Electrical Code (ANSI/NFPA 70) or the Canadian Electrical Code (CSA C22.1).
  8. Gas Type: Ensure that you use the gas type specified on the rating plate of the appliance. The Bellavista B41XTCE Gas Fireplace is not convertible for use with other gases.
  9. Structural Integrity: During installation, make sure that no structural members are cut or weakened, ensuring the fireplace’s stability and safety.

For more detailed information and instructions, please refer to the complete user manual provided with the Bellavista B41XTCE Gas Fireplace.

For any further assistance or inquiries, please visit our website at www .regency-fire.com.

Bellavista® B41XTCE Gas Fireplace

Owners & Installation Manual

MODELS: B41XTCE-NG11 B41XTCE-LP11

Bellavista B41XTCE Video

French Manual: https://bit.ly/3czgZok Manuel en français : https://bit.ly/3czgZok

www.regency-fire.com

Warning Fire or Explosion Hazard Failure to follow safety warnings exactly could result in serious injury, death, or property damage.
– Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
– WHAT TO DO IF YOU SMELL GAS · Do not try to light any appliance. · Do not touch any electrical switch: do not use any phone in your building. Leave the building immediately. · Immediately call your gas supplier from a neighbour’s phone. Follow the gas supplier’s instructions. · If you cannot reach your gas supplier, call the fire department. · Installation and service must be performed by a qualified installer, service agency or the gas supplier.

Tested by:
920-035l

Certified to/Certifié pour: CSA 2.17-2017 ANSI Z21.88-2019 CSA 2.33-2019

Installer: Please complete the details on the back cover and leave this
manual with the homeowner.
Homeowner: Please keep these instructions for future reference.

FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4

05.19.23

To the New Owner:
Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY®. The BellavistaTM B41XTCE has been designed to provide you with all the warmth and charm of a wood fireplace at the flick of a switch. The BellavistaTM B41XTCE has been approved by Warnock Hersey/Intertek for both safety and efficiency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble-free years to follow. Please take a moment now to acquaint yourself with these instructions and the many features of your Regency® Fireplace.

Front
! DANGER

HOT GLASS WILL CAUSE BURNS
DO NOT TOUCH GLASS UNTIL COOLED
NEVER ALLOW CHILDREN TO TOUCH GLASS

A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and must be installed for the protection of children and other at risk individuals.
CAUTION:
HOT WHILE IN OPERATION. DO NOT TOUCH. SEVERE BURNS MAY RESULT. KEEP CHILDREN, CLOTHING, FURNITURE, GASOLINE, AND ANY OTHER LIQUIDS WITH FLAMMABLE VAPOURS AWAY.

KEEP BURNER AND CONTROL COMPARTMENT CLEAN.

SEE INSTALLATION AND OPERATING INSTRUCTIONS ACCOMPANYING

APPLIANCE.

920-408

!
L’écran pare-étin contact accident enfants et des pe
ATTENT
Risque de brûl Ne pas toucher Ne pas laisser vêtements, les à distance de l S’assurer que l Voir les instruc l’appareil.

920-408
On Dem4.3a4.7nd Pilot Light (seven-day safety timer)
Instruction Plate Important Finofor ramgalatisosn- firfounsteindggtahseaapppplilaianncceewinheCrePIth(ecotnetminpueoruastupreilootf mthoedgela) sosnly. This appliavniceewiisnga aPrreoaFloaumtseid1essyusrtfeamcefiettxecdeewdisththtehelim”Oitns sDpeemciafined”inPiClolta,uasesa5f.e1t4y.4fe, athtuerfeolwlohwicinhgwill shut down the gas valve completely by extinguishing the pilot ligghrtapinhitchedaenvgeenrtaonfdasctaotnetmineunotusssfhualll sbeeveshnodwanysonofainCalactsisviItIyI.A-2 Permanent Label. This only a4p.p3l4ie.6s if the CPI (continuous pilot) switch is in the “on” position. ETdaahycehssoetifvmeinena- tIEacdnhtdaaseijvcytarihmtcuiynecaa,antpitincothptnteliboivauPiIttnPrhylacnIeet/eteiCcrmsoPshenIhartrulrloiotsbsclleckindoeagonrrwtdasrwenoCv,liltliemaccdehsaswonwIruiIitIlaihlBnlirlnyaemmntoahrearekqitnihncurigairnoclluwuytghiitcthheobntl”oehosatenptrei”dccr.saupTloool husnfirsetoairopmecnofoo.stnrihTtetiehor,aneitsfhrwteieinnfhrogmeCrrePboe,aIstactmhaklletog,tdrihntoeahsutetanriundsscd ,ertlveiowoeqcnhnuae- citdrenaeadndtyhbtteoeimpreieelaorlsitgsilhltyiagtrrhtethtsaeidas.pgeialxoitntin.wgouuislhdebdeatfoteprrseesvsetnhestorani/gohftf bnuotrteoqnuoirnemtADhepoenruirtlbe2ltmeo2/os1ditd4oee:acdConrnyettahrotienldgtrdawrnaitsfhmt tihtteerIPfrIo/CmP”Iorno”cktoer”sowffi”tcahn.d back to “on”. Once the pilot has re-established operation will resume as normal. There is If the unit Mneavteerriaglo: eSsynatshleotnicgPaaspseerven full days without a call for heat, the pilot will remain lit until it is manually shutoff. If the unit Sisizbeei5n.g96o5p”eWratxed5.7in1″IPHI (intermittent pilot) mode, neither the above instructions nor the seven-day timer will apply. See the insCtroulcotri:oAnss sinhothwins imnaanrtuwaol raknd on the Lighting Instructions plate on the appliance to light or relight the pilot.
2 | Regency Bellavista® B41XTCE -11 Gas Fireplace

MANUFACTURED MOBILE HOME REQUIREMENTS
INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE
This Regency® product has been tested and listed by Warnock Hersey as a Direct Vent Wall Furnace to the following standards: VENTED GAS FIREPLACE HEATERS ANSI Z21.88 · CSA 2.33 and Gas-fired Appliances for Use at High Altitudes CSA 2.17-2017.
This Direct Vent System Appliance must be installed in accordance with the manufacturer’s installation instructions and the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240-MH Mobile Home Standard in Canada.
This appliance installation must comply with the manufacturer’s installation instructions and local codes, if any. In the absence of local codes follow the current National Fuel Gas Code, ANSI Z223.1 and the current National Electrical Code ANSI/NFPA 70 in the U.S.A., and the current CSA B149.1 Gas Installation Code and the current Canadian Electrical Code CSA C22.1 in Canada.
This appliance comes equipped with a dedicated #8 Ground Lug for attachment of the ground wire to the steel chassis as applicable to local codes.
The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.
This appliance may only be installed in an aftermarket permanently located, manufactured (U.S.A. only) or mobile home, where not prohibited by local codes.
This appliance can only be used with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
Ensure that structural members are not cut or weakened during installation.

Bellavista B41XTCE Video

Bellavista B41XT Gas Fireplace Benefits

Regency Bellavista® B41XTCE -11 Gas Fireplace | 3

table of contents
Owner’s information
Copy of the Safety Decal………………………………………………………. 5 Decal Location …………………………………………………………………… 5 Unit Dimensions …………………………………………………………………. 7 Important Message …………………………………………………………. 10 Before You Start……………………………………………………………….. 10 General Safety Information …………………………………………………. 10 Lighting Procedure ……………………………………………………………. 11 Shutdown Procedure …………………………………………………………. 11 Copy of Lighting Plate Instructions ……………………………………….. 12 Proflame I Remote Control Operating Instructions ……………………. 13
Installer’s information
Gas Installation Checklist ……………………………………………………… 8 Proflame I Remote Receiver Battery Replacement…………………….. 17 Installation Checklist ………………………………………………………. 18 Locating Your Gas Fireplace ………………………………………………… 18
Installation
Clearances ………………………………………………………………………. 19 B41XTCE Clearance Requirements ………………………………………… 19 Mantel Clearances …………………………………………………………….. 20 Mantel Leg Clearances ……………………………………………………….. 21 Non-Combustible Requirements……………………………………………. 21 Framing …………………………………………………………………………. 22 Framing & Finishing…………………………………………………………… 23
Tile Finish ……………………………………………………………….. 23 Clean Finish …………………………………………………………….. 23 Unit Assembly Prior to Installation ………………………………………… 25 Top Standoff Assembly……………………………………………….. 25 Nailing Strips……………………………………………………………. 25 Wall Mount On/Off Switch …………………………………………………… 26 Conversion to Top Vent………………………………………………………. 27 Venting Introduction………………………………………………………….. 29 Vent Restrictor & Baffle Installation……………………………………….. 29 Exterior Vent Termination Requirements…………………………………. 30 5″ x 8″ Rigid Pipe – Cross Reference Chart only ………………………. 31 Rigid Pipe Venting Systems …………………………………………………. 33 Venting Arrangements for Horizontal Terminations – Flex Vent or Rigid Pipe 5″ x 8″ ………………………………………………………… 34 Horizontal Terminations – Flex Vent 5″ x 8″ …………………………….. 35 Horizontal Terminations – Rigid Pipe 5″ x 8″…………………………….. 36 Horizontal Terminations ……………………………………………………… 37 Horizontal terminations………………………………………………………. 37 Horizontal Terminations – AstroCap XL & Rigid Rear Vent Kit for Corner Installations – Rigid Pipe 5″ x 8″ ……………………………….. 38 Venting Arrangements for Horizontal Terminations……………………. 39 Unit Installation with Horizontal Termination – 5″ x 8″ Venting (Rigid Vent Systems) ……………………………………………………….. 40 Unit Installation with Horizontal Termination – 5″ x 8″ Venting (Flex Vent Systems)…………………………………………………………. 41 Venting Arrangements for Vertical Terminations ……………………….. 42 Vertical Terminations – Three 90o Elbows (Rigid Pipe 5″ x 8″)………. 43 Unit Installation with Vertical Termination – 5″ x 8″ Venting (Rigid Vent Systems) ……………………………………………………….. 44 Gas Line Installation ………………………………………………………….. 44 Vertical Terminations – Vertical Flex Vent Kit (Part #946-772) ……… 45 Vertical Flex Extension Kit (Part # 946-769) ……………………………. 47 Ceiling Firestop / Firestop Spacer (Part # 946-770)…………………… 48 Pilot Adjustment……………………………………………………………….. 49 High Elevation………………………………………………………………….. 49 885 S.I.T. Valve Description…………………………………………………. 49 Gas Pipe Pressure Testing …………………………………………………… 49 Brick Panel Installation ………………………………………………………. 50 Optional Black Enamel Panel Installation ………………………………… 51 Log Set Installation …………………………………………………………… 53
4 | Regency Bellavista® B41XTCE -11 Gas Fireplace

AC Power Adaptor Installation (for Surefire Systems) ………………… 57 Wiring Diagram ………………………………………………………………… 58 Optional Fan Installation …………………………………………………….. 59 Wiring Diagram with Optional Fan ………………………………………… 61 Optional Wall Thermostat Installation ……………………………………. 62 Flush Glass Door Installation ……………………………………………….. 63 Safety Screen…………………………………………………………………… 63
Operating Instructions
Operating Instructions ……………………………………………………….. 64 First Fire …………………………………………………………………………. 64 Normal Operating Sounds of Gas Appliances …………………………… 64 Aeration Adjustment………………………………………………………….. 64 Lighting Procedure ……………………………………………………………. 65 Shutdown Procedure …………………………………………………………. 65 Copy of Lighting Plate Instructions ……………………………………….. 66
Maintenance
Maintenance Instructions ……………………………………………………. 67 General Vent Maintenance ………………………………………………….. 67 Log Replacement ……………………………………………………………… 67 Glass Gasket ……………………………………………………………………. 67 Door Glass………………………………………………………………………. 67 Glass Replacement ……………………………………………………………. 67 Valve Replacement ……………………………………………………………. 68 Installing Valve…………………………………………………………………. 68 Gas Maintenance – Recommended Annual Routine……………………. 69
Parts List
Main Assembly …………………………………………………………………. 70 Burner Assembly ………………………………………………………………. 71
Warranty
Warranty ………………………………………………………………………… 72

safety decal

This is a copy of the label that accompanies each BellavistaTM B41XTCE Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. NOTE: Regency® units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.

Copy of the Safety Decal

Duplicate S/N

511

C #: 4001172

Listed/Nom: VENTED GAS FIREPLACE / FOYER AU GAZ À ÉVACUATION Certified to/Certifié pour: ANSI Z21.88:2019 · CSA-2.33:2019
CSA 2.17-2017 MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE.
Refer to Intertek’s Directory of Building Products for detailed information. Pour plus de détails , se reporter au Répertoire des produits de construction de Intertek.

DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE Serial No./ No de série
511

NATURAL GAS: Model B41XTCE-NG11

APPAREIL FONCTIONNANT AU GAZ NATUREL Modèle B41XTCE-NG11

Minimum Clearances to Combustibles / Dégagements minimaux par rapport aux matériaux combustibles

Minimum supply pressure Manifold pressure high Manifold pressure low Orifice size Minimum input Maximum input Altitude

5.0″ WC/C.E. (1.25 kPa)

3.5″ WC/C.E. (0.87 kPa)

1.6″ WC/C.E. (0.40 kPa)

30 DMS

30,000 Btu/h (8.79 kW)

42,500 Btu/h (12.45 kW)

0-4500 ft/pi

(0-1372 m)

PROPANE GAS: Model B41XTCE-LP11

Minimum supply pressure 11″ WC/C.E. (2.74kPa)

Manifold pressure high 10″ WC/C.E. (2..49kPa)

Manifold pressure low 6.4″ WC/C.E. (1.60kPa)

Orifice size

49 DMS

Minimum input

29,500 Btu/h (8.65 kW)

Maximum input

37,500 Btu/h (10.99 kW)

Altitude

0-4500 ft/pi

(0-1372 m)

Pression d’alimentation minimale Pression manifold – élevée Pression manifold – basse Taille de l’orifice Débit calorifique minimal Débit calorifique maximal Altitude
APPAREIL FONCTIONNANT AU GAZ PROPANE Modèle B41XTCE-LP11 Pression d’alimentation minimale Pression manifold – élevée Pression manifold – basse Taille de l’orifice Débit calorifique minimal Débit calorifique maximal Altitude

Ceiling

C D
A

Wall
F

E
Floor
DOOR SEAL: Please check that the door is
properly sealed

Mantel Clearances from

Fireplace Opening:

(A) Min. 17-9/16″ (446mm)

Side Wall Clearance

from Fireplace Opening

B) Min. 9″ (229mm)

Ceiling from Top of

Fireplace Opening:

C) 36-5/8″ (930mm)

Mantel Depth:

D) Max. 12″ (304mm)

Alcove Clearances:

E) Min. Width 60″ (1524mm),

F) Max. Depth 36″ (914mm)

Minimum Vent Clearances:

Horizontal Top

3″ (76mm)

Horizontal Side

2″ (51mm)

Horizontal Bottom 2″ (51mm)

Vertical Vent

2″ (51mm)

(See Instruction Manual for detailed instructions)

This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.

This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the

United States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard.

This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See

owner’s manual for details.

Installer l’appareil selon les codes ou règlements locaux, ou, en l’absence de tels règlements, selon les codes d’installation ANSI Z223.1, National Fuel Gas Code ou CSA-B149.1 en vigueur.

Installer l’appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280, Manufactured Home Construction and Safety Standard.

Si ces normes ne sont pas pertinentes, utilisez la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard, ou ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles.

Cet appareil doit être utilisé uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison préfabriquée ou mobile (É.-U. seulement) installée à demeure si les

règlements locaux le permettent. Voir la notice de l’utilisateur pour plus de renseignements. Cet appareil ne peut pas être utilisé avec d’autres gaz sauf si une trousse de conversion certifiée est fournie.

This vented gas fireplace heater is not for use with air filters.

Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.

For use with glass doors certified with the appliance only

À utiliser seulement avec les portes vitrées certifiées avec l’appareil

Electrical supply / Alimentation électrique 115VAC, 1.13 A, 60Hz.

Made in Canada/ Fabriqué au Canada

FPI Fireplace Products International Ltd. Delta, BC, Canada

For Use Only with Barrier (Part # 508-100) Follow installation instructions.

Utiliser uniquement avec l’écran (n°508-100). Suivre les consignes d’installation.

VENTED GAS FIREPLACE HEATER – NOT FOR USE WITH SOLID FUELS. CATEGORY I.

FOYER AU GAZ À ÉVACUATION – NE PAS UTILISER AVEC UN COMBUSTIBLE SOLIDE. CATÉGORIE I.

EP5011169

CANADIAN ENERGY PERFORMANCE VERIFIED
RENDEMENT ÉNERGÉTIQUE
VÉRIFIÉ

CSA P.4.1 Fireplace Efficiency (FE) /Efficacité énergétique des foyers (EEF) CSA P.4.1 Natural Gas / Gaz naturel 68.15% Propane Gas / Gaz propane 68.35%

920-034b

For the State of Massachusetts, installation

Decal Location

and repair must be done by a plumber or

PCagMoralaotssu#sfr:ia:t9tcEe2hvr0ue- lsir0cey3etth4tnsibsn.egdbilnactkheonCogmremy oenxwceepatltinhdoicfated items to be printed red.

Size: File at 100% 9.08”W x 6.231”H MFaoter ritahl:e2 Smtal tseilveorf mMaattsspaoclyheussteetrts(D, PflMexSibMleS)

connectors shall not exceed 36 inches in Jalenn1g6th/1.9: Created draft

Jan 24/19: Rev A – Remodeled decal + added ETL logo at the bottom

AuFgor2/2th2e: RSetavtBe -oSftaMndaasrsdascuhpudsaetettss, the

appliances individual manual shutoff must

*Pbreinatetr-:hCanodnlteintuyepenuvmalbveer. sequence from 919-163 – do not restart at 0

The State of Massachusetts requires the
installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with battery backup in the same room where
the gas appliance is installed.

Remove the faceplate from unit (refer to manual) the rating plate will be attached to a black chain as shown below.
DO NOT REMOVE DECAL FROM UNIT.

Regency Bellavista® B41XTCE -11 Gas Fireplace | 5

requirements

5.08: Modifications to NFPA-54, Chapter 10

MA Code – CO Detector
(for the State of Massachusetts only)

(2) Revise 10.8.3 by adding the following additional requirements:

(a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:

1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors

a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.

b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.

2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.

3. SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size, “GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS”.

4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4.

(b) EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:

1. The equipment listed in Chapter 10 entitled “Equipment Not Required To Be Vented” in the most current edition of NFPA 54 as adopted by the Board; and

2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes.

(c) MANUFACTURER REQUIREMENTS – GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:

1. Detailed instructions for the installation of the venting system design or the venting system components; and

2. A complete parts list for the venting system design or venting system.

(d) MANUFACTURER REQUIREMENTS – GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies “special venting systems”, the following requirements shall be satisfied by the manufacturer:

1. The referenced “special venting system” instructions shall be included with the appliance or equipment installation instructions; and

2. The “special venting systems” shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed installation instructions.

(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipmentat the completion of the installation.

6 | Regency Bellavista® B41XTCE -11 Gas Fireplace

16-7/16″ [417mm]

Unit Dimensions
46-11/16″ [1185mm] 38-3/8″ [974mm] 46-11/16″ [1185mm]

22-5/8″ [559mm] 25-9/16″ [649mm]

dimensions
26-3/16″ [664mm]

11-5/8″ [294mm]

1-1/2″ [38mm] 28-1/2″ [724mm] 36-3/8″ [923mm] 38-1/4″ [971mm]

49-1/4″ [1251mm]

32-5/8″ [829mm]

29-1/8″ [738mm]

44-1/4″ [1123mm] 23-7/16″ [594mm]

1-9/16″ [39mm]

3-5/8″ [92mm]

35″ [889mm] 38-7/16″ [976mm]

7-5/16″ [185mm] 3-1/4″

Note: Gas connection is from the right-hand side of the appliance & electrical connection on the left-hand side of the appliance. A metal receptacle box is supplied/installed with the appliance to make all 120 volt electrical connections.
ALL PICTURES / DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY. ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENTS.
Regency Bellavista® B41XTCE -11 Gas Fireplace | 7

dimensions
Gas Installation Checklist

This general checklist does not contain all pertinent installation details or specifics and does not supersede the guidelines in this manual. Your Regency dealer/installer should use it in conjunction with manual instructions. Please follow all local codes and jurisdictions in authority.

Customer: Install Address: Serial No: Model No:

Date Installed: Location of Fireplace: Installer:

Site Requirements

YES NO

If applicable, are the insulation, vapour barrier, and drywall present if installed on an outside wall or chase?
Does the area have a solid continuous base to support the unit? Will the area accommodate the size of the applliance and all clearances? Are the gas and electrical roughed into the area where the unit is being installed?
In City & Grandview series cool wall applications, is the chase enclosure sealed to prevent heat from escaping? All hot air from the unit must exit via the mandatory ventilation openings. In City & Grandview applications, Is the chase enclosure vented with the mandatory heat ventilation openings? See manual for details. If applicable, is the masonry/factory built freplace in its original condition with no modifications?
If applicable, have the hearth requirements been met?
Unit Setup

YES NO

If applicable, are the standoffs and top nailing flange extensions installed and at the correct depth to accommodate finishing material? See manual for details. If applicable, is the fireplace level and secured, meeting framing clearances? See manual for details. If applicable, is the unit converted to top or rear vent per manual instructions, and the insulation discarded?
Venting

YES NO

Are the venting components approved for the unit installed? Does the venting configuration comply with venting diagrams? Is venting installed and secured, and are clearances for the vent pipe and termination cap maintained? If applicable, was a 1/4″ rise maintained for every foot of horizontal run? Was the termination installed and sealed? Is the direct vent termination at the highest point in the vent assembly? If applicable, are both chimney liners continuous from flue collars to termination? Electrical and Wiring

YES NO

Is the appliance connected to the household’s 110/120v per local codes? Check local codes for receptacle placement. Were the connections in the fireplace tested with a circuit tester? Is the appliance properly grounded? If applicable, is the supplied electrical/gang box affixed to the wall to facilitate the mounting of the receiver/battery box ? Gas

YES NO

Does the supply pressure meet the requirements shown on the rating plate? Was a conversion performed? Was a leak check performed and manifold pressures verified? Is the shut-off valve installed and easily accessible to the customer?

8 | Regency Bellavista® B41XTCE -11 Gas Fireplace

Finishing If applicable, is only noncombustible material installed in the noncombustible areas? Do clearances meet installation and manual requirements? Do the mantels and/or projections comply with the installation manual? If applicable, was the solid fuel fireplace warning plate installed? Appliance Media Setup Do commands from the remote or wall switch light the pilot and main burner?
Are the burner media/log set, glass door, and screen installed per instructions in the manual? Was the air shutter on the proper setting after running the unit for 20 minutes? If applicable, were the surround and trims installed according to the manual? Was the operation of the fan, lights (if installed), and flame modulation checked? Customer Tutorial and Presentation Is the customer confident operating the new gas appliance and aware of all the features on the remote? Confirm that the rating and lighting plates are attached to the appliance. Do not remove. Was the customer informed of the location of the rating and lighting plates? Was accessing unit controls in a power outage explained to the customer? Are the model and serial numbers and the date of installation of the unit written in the manual and on the checklist? Were the warranty and unit registration reviewed with the customer? Comments:

installation
YES NO YES NO
YES NO

Regency Bellavista® B41XTCE -11 Gas Fireplace | 9

owner’s information
Important Message SAVE THESE
INSTRUCTIONS
The B41XTCE-11 Gas Fireplace must be installed in accordance with these instructions. Carefully read all the instructions in this manual first. Consult the “authority having jurisdiction” to determine the need for a permit prior to starting the installation. It is the responsibility of the installer to ensure this fireplace is installed in compliance with the manufacturer’s instructions and all applicable codes.
Before You Start
Safe installation and operation of this appliance require common sense, however, we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following:
INSTALLATION AND REPAIR SHOULD BE DONE BY AN AUTHORIZED SERVICE PERSON. THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A PROFESSIONAL SERVICE PERSON. MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING, BEDDING MATERIAL, ETC. IT IS IMPERATIVE THAT CONTROL COMPARTMENTS, BURNERS AND CIRCULATING AIR PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN.
DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES.
WARNING: FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILL VOID YOUR WARRANTY AND MAY CAUSE A SERIOUS HOUSE FIRE.
CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES, ESPECIALLY THE FIREPLACE GLASS, AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION.

YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME AREA AS THE APPLIANCE. TODDLERS, YOUNG CHILDREN AND OTHERS MAY BE SUSCEPTIBLE TO ACCIDENTAL CONTACT BURNS. A PHYSICAL BARRIERS IS RECOMMENDED IF THERE ARE AT RISK INDIVIDUAL IN THE HOUSE. TO RESTRICT ACCESS TO A FIREPLACE OR STOVE, INSTALL AN ADJUSTABLE SAFETY GATE TO KEEP TODDLERS, YOUNG CHILDREN AND OTHER AT RISK INDIVIDUALS OUT OF THE ROOM AND AWAY FROM HOT SURFACES.
CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE.
A BARRIER DESIGNED TO REDUCE THE RISK OF BURNS FROM THE HOT VIEWING GLASS IS PROVIDED WITH THIS APPLIANCE AND SHALL BE INSTALLED FOR THE PROTECTION OF CHILDREN AND OTHER AT-RISK INDIVIDUALS
IF THE BARRIER BECOMES DAMAGED, THE BARRIER SHALL BE REPLACED WITH THE MANUFACTURER’S BARRIER FOR THIS APPLIANCE.
ANY SAFETY SCREEN, GUARD, OR BARRIER REMOVED FOR SERVICING THE APPLIANCE, MUST BE REPLACED PRIOR TO OPERATING THE APPLIANCE.
General Safety Information
1. The appliance installation must conform with local codes or, in the absence of local codes, with the current Canadian or National Gas Codes, CAN1-B149 or ANSI Z223.1 Installation Codes.
2. The appliance when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes with the current National Electrical Code, ANSI/ NFPA 70 or CSA C22.1 Canadian Electrical Code.

3. See general construction and assembly instructions. The appliance and vent should be enclosed.
4. This appliance must be connected to the specified vent and termination cap to the outside of the building envelope. Never vent to another room or inside a building. Make sure that the vent is fitted as per Venting instructions.
5. Inspect the venting system annually for blockage and any signs of deterioration.
6. Venting terminals shall not be recessed into a wall or siding.
7. Any safety glass removed for servicing must be replaced prior to operating the appliance.
8. To prevent injury, do not allow anyone who is unfamiliar with the operation to use the fireplace.
9. Wear gloves and safety glasses for protection while doing required maintenance.
10. Be aware of electrical wiring locations in walls and ceilings when cutting holes for termination.
11. Under no circumstances should this appliance be modified. Parts that have to be removed for servicing should be replaced prior to operating this appliance.
12. Installation and any repairs to this appliance should be done by a qualified service person. A professional service person should be called to inspect this appliance annually. Make it a practice to have all of your gas appliances checked annually.
13. Do not slam shut or strike the glass door.
14. Under no circumstances should any solid fuels (wood, paper, cardboard, coal, etc.) be used in this appliance.
15. The appliance area must be kept clear and free of combustible materials (gases and other flammable vapors and liquids).

10 | Regency Bellavista® B41XTCE -11 Gas Fireplace

owner’s information

Lighting Procedure

IMPORTANT: The remote control system supplied with this appliance has several options for starting/operating the appliance using the power button and ON/OFF key on the hand-held transmitter. Prior to operating this appliance, please read the remote control operating instructions (packaged with remote control) to understand how to operate this remote control system. Option to download remote functions video with QR code below.
Proflame video

3. After approximately 4 seconds the spark ignition system will spark for 60 seconds to light the pilot.
4. The unit will turn on.
Note: The first try for ignition will last approximately 60 seconds. If there is no flame ignition (rectification) the board will stop sparking for approximately 35 seconds. After wait time , the board will start second try for ignition by sparking for approximately 60 seconds. If there is still no positive ignition the board will go into lock out.

1. Ensure the wall switch/receiver is in the remote position (see Diagram 1).
Set Switch to Remote

The system will need to be reset as follows:
a) Turn the system off using ON/OFF switch or press ON/OFF button – if using remote.
b) After approximately 2 seconds turn on ON/OFF switch or press ON/OFF button if using remote.
c) Repeat step 2.

Shutdown Procedure

1. Turn the wall-mounted switch or remote to the “OFF” position.

2. Press “OFF” on the remote control.

Diagram 1
2. Press and release the ON/OFF button on the remote hand-held transmitter (see Diagram 2). An audible beep should be heard from the receiver.

3. Turn the gas control knob to the “OFF” position to turn off the pilot.

ON/OFF Button
Diagram 2 Remote shown in Manual Mode on Hi
Note: May not be exactly as shown as hand-held may be silver or black.
Regency Bellavista® B41XTCE -11 Gas Fireplace | 11

owner’s information

Copy of Lighting Plate Instructions

FOR YOUR SAFETY READ BEFORE LIGHTING
POUR VOTRE SÉCURITÉ ­ À LIRE AVANT LA MISE EN MARCHE
WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or gas supplier.
AVERTISSEMENT : Quiconque ne respecte pas scrupuleusement les instructions de la présente notice risque de déclencher un incendie ou une explosion pouvant entraîner des dégâts matériels ou des blessures pouvant être mortelles. Tout défaut d’installation, de réglage, de modification, de service ou d’entretien peut entraîner des blessures ou des dommages matériels. Reportez-vous au manuel d’utilisation fourni avec cet équipement. Pour obtenir de l’aide ou des informations complémentaires, consulter un installateur ou un service d’entretien qualifié, ou le fournisseur de gaz.
A) This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand.
B) BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS – Do not try to light any appliance. – Do not touch any electric switch, do not use any phone in your building. – Leave the building immediately. – Immediately call your gas supplier from a neighbours phone. Follow the gas supplier’s instructions. – If you cannot reach your gas supplier, call the fire department.
C) Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been underwater.
A) Cet appareil est muni d’un dispositif d’allumage qui allume automatiquement la veilleuse. Ne tentez pas d’allumer la veilleuse manuellement.
B) AVANT LA MISE EN MARCHE, reniflez tout autour de l’appareil pour déceler une odeur de gaz. Reniflez au niveau du plancher, car certains gaz sont plus lourds que l’air et peuvent s’accumuler au niveau du sol.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ : · Ne tentez pas d’allumer l’appareil · Ne touchez à aucun interrupteur; n’utilisez pas le téléphone se trouvant dans le bâtiment. · Quittez immédiatement le bâtiment. · Appelez immédiatement votre fournisseur de gaz depuis un téléphone extérieur. Suivez les instructions du fournisseur. · Si vous ne pouvez pas rejoindre le fournisseur, appelez le service incendie.
C) N’utilisez pas cet appareil s’il a été plongé dans l’eau, même partiellement. Faites inspecter l’appareil par un technicien qualifié et remplacez tout élément du système de contrôle ou de commande qui a été plongé dans l’eau.
CAUTION: Hot while in operation. Do not touch. Severe burns may result. Due to high surface temperatures keep children, clothing and furniture, gasoline and other liquids having flammable vapors away. Keep burner and control compartment clean. See installation and operating instructions accompanying appliance.
ATTENTION : Surfaces chaudes lorsque l’appareil est en marche. Ne pas toucher. Risque de brûlures graves. En raison des températures élevées, les enfants, les vêtements et le mobilier, le carburant et tout autre liquide aux vapeurs inflammables doivent être tenus éloignés de l’appareil. Nettoyer régulièrement le brûleur et le compartiment des commandes. Voir les consignes d’installation et d’utilisation fournies avec l’appareil.

OPERATING INSTRUCTIONS / CONSIGNES DE FONCTIONNEMENT

  1. STOP! Read the safety information above on this label.

  2. Ensure the Main switch is in the ON position and/or the wall mounted battery holder (if equipped) is in the position.

  3. Press and release the ON/OFF button on the remote handheld transmitter. An audible beep should be heard from the receiver. If not using the remote, the unit can also be turned on by sliding the battery holder switch to the position (if equipped).

  4. After approximately 4 seconds the spark ignition system will spark for 60 seconds to light the main burner.

  5. The unit will turn on. Note: The first attempt to ignition will last approximately 60 seconds. If there is no flame ignition (rectification) the board will stop sparking for approximately 35 seconds. After this wait time, the board will start a second try for ignition by sparking for approximately 60 seconds. If there is still no positive ignition after the second attempt the board will go into lock out. The system will need to be reset as follows (after going into lock out mode):
    a) Wait 5 minutes – turn the system off by pressing the ON/OFF button on the remote. b) After approximately 2 seconds press the ON/OFF button again. c) Unit will repeat step 2. 6) If the appliance will not operate, follow the instructions, “To Turn Off Gas to Appliance” and call your service technician or gas supplier. This appliance is equipped with an on-demand pilot that shuts off after seven days.

  6. STOP! Lisez les instructions de sécurité sur la portion supérieure de cette étiquette.

  7. S’assurer que le commutateur principal est en position ON et/ou que le bloc-piles mural (le cas échéant) est en position . 3) Appuyer sur la touche ON/OFF de la télécommande puis relâcher. Un bip sonore retentira depuis le récepteur. Si vous n’utilisez pas la
    télécommande, l’appareil peut également être allumé en faisant glisser le commutateur du bloc-piles sur la position (le cas échéant). 4) Après environ 4 secondes, le système d’allumage produira une étincelle pendant 60 secondes pour allumer le brûleur principal. 5) L’appareil s’allumera. Remarque : Au premier allumage, le système tente d’allumer les flammes pendant 60 secondes. Si l’essai est infructueux, le système fera une pause de 35 secondes. C’est ce qu’on appelle l’étape de rectification. Ce délai écoulé, le système tente à nouveau d’allumer les flammes en produisant des étincelles pendant 60 secondes. Si les flammes ne s’allument toujours pas, le système se met en mode verrouillage. Il faut alors le réinitialiser en suivant les étapes ci-dessous (pour le déverrouiller) :
    a) Attendre 5 minutes et éteindre l’appareil en appuyant sur la touche ON/OFF de la télécommande. b) Attendre 2 secondes et appuyer encore une fois sur la touche ON/OFF. c) L’appareil répètera l’étape 2. 6) Si l’appareil ne fonctionne pas, suivez les instructions “Pour couper le gaz au niveau de l’appareil” et appelez un technicien qualifié ou votre fournisseur de gaz. Cet appareil est équipé d’une veilleuse sur demande qui s’éteint après sept jours.
    TO TURN OFF GAS TO APPLIANCE / POUR COUPER LE GAZ AU NIVEAU DE L’APPAREIL

  8. Press the ON/OFF button on the remote or slide the wall mount switch to the “OFF” position. 2) If service is to be performed­you must disconnect power and shut off gas to the unit. 1) Appuyer sur la touche ON/OFF de la télécommande ou faites glisser l’interrupteur mural sur la position “OFF”. 2) Lors de l’entretien de l’appareil, vous devez débrancher l’alimentation électrique et couper le gaz alimentant l’appareil.

DO NOT REMOVE THIS INSTRUCTION PLATE

NE PAS ENLEVER CETTE ÉTIQUETTE D’INSTRUCTIONS

919-649b

12 | Regency Bellavista® B41XTCE -11 Gas Fireplace

owner’s information

Proflame I Remote Control Operating Instructions

IMPORTANT:The Proflame Transmitter 2 is an integrated part of the

Proflame 2 System, which consists of these elements:

·

Proflame 2 Transmitter, to be used in conjunction with:

·

Integrated Fireplaces Control (Proflame 2 IFC)

The Proflame 2 Transmitter provides for controlling the following hearth

appliance functions:

Main Burner On/Off

Main Burner flame modulation (6 levels)

Choice of standing or intermittent pilot (CPI/IPI)

Thermostat and Smart thermostat functions

Accent light modulation (6 levels)**

Split flow valve**

Comfort Fan speed modulation (6 levels)**

** This feature is not available on all models.

The Proflame Transmitter uses a streamline design with a simple button layout and informative LCD display (Fig. 1). A Mode Key is provided to index between the features and a Thermostat Key is used to turn on/off or index through Thermostat functions (Fig. 1 & 2). Additionally, a Key Lock feature is provided (Fig. 22).

TECHNICAL DATA REMOTE CONTROL

Supply Voltage

4.5V (three 1.5V AAA batteries)

Ambient temperature ratings
Radio Frequency

0 – 50oC (32 – 122oF) 315 MHZ

WARNING:THETRANSMITTER AND RECEIVER ARE RADIO FREQUENCY DEVICES. PLACING THE RECEIVER IN OR NEAR METAL MAY SEVERELY REDUCETHE SIGNAL RANGE.
ATTENTION!
– Turn “OFF” the main gas supply of the appliance during installation or maintenance of the Receiver device.
– Turn “OFF” main gas supply to the appliance prior to removing or reinserting the batteries.

– In case of remote control malfunction, turn off the IFC device using the “ON/OFF” main switch.

– For installation / maintenance, switch off the IFC device removing main power supply plug.

Figure 1: Proflame Transmitter

OPERATING PROCEDURE
Pairing the remote control to remote receiver/battery holder (if required)
Power the receiver. Press the “PRG” button located on the top right hand side of receiver, see the receiver instruction (). The Receiver will “beep” three (3) times to indicate that it is ready to synchronize with a Transmitter. Install the 3 AAA type batteries in the Transmitter battery bay, located on the base of the Transmitter. (fig. 3) With the batteries already installed in the Transmitter, push the On button. The Receiver will “beep” four times to indicate the Transmitter’s command is accepted and sets to the particular code of that Transmitter. The system is now initialized.
(
) The receiver may be independent or integral to the IFC hearth appliance control module. The receiver instruction may not be independent when part of the IFC.

Figure 2: Transmitter LCD Display
Note: May not be exactly as shown as hand-held may be silver or black.

Figure 3: Battery Compartment Regency Bellavista® B41XTCE -11 Gas Fireplace | 13

owner’s information

Temperature indication Display

Remote-Flame Control

With the system in the “OFF” position, press the Thermostat Key and the Mode Key at the same time. Look at the LCD screen on the transmitter to verify that a C or F is visible to the right of the room temperature display (Figures 4 & 5).

The Proflame has six (6) flame levels. With the system on, and the flame level at the maximum in the appliance, pressing the Down Arrow Key once will reduce the flame height by one step until the flame is turned off. The Up Arrow Key will increase the flame height each time it is pressed. If the Up Arrow Key is pressed while the system is on but the flame is off, the flame will come on in the high position. ( Fig. 7 & 8 ) A single “beep” will confirm reception of the command.

Figure 4: Remote Control display in Farenheit.

Figure 5: Remote Control display in Celsius.

Fig. 7

Turn on the Appliance
With the system OFF, press the ON/ OFF Key on the Transmitter. The Transmitter display will show some other active Icons on the screen. At the same time the Receiver will activate the appliance. A single “beep” from the Receiver will confirm reception of the command.

Fig. 8
Room Thermostat (Transmitter Operation)

Figure 6: Remote Control display
Turn off the Appliance
With the system ON, press the ON/OFF Key on the Transmitter. The Transmitter LCD display will only show the room temperature (Fig. 6). At the same time the Receiver will turn off the appliance. A single “beep” from the Receiver confirms reception of the command.

The Remote Control can operate as a room thermostat. The thermostat can be set to a desired temperature to control the comfort level in a room. To activate this function, press the Thermostat Key (Fig. 1). The Lcd display on the Transmitter will change to show that the room thermostat is “ON” and the set temperature is now displayed (Fig. 9). To adjust the set temperature, press the Up or Down Arrow Keys until the desired set temperature is displayed on the LCD screen of the Transmitter.

14 | Regency Bellavista® B41XTCE -11 Gas Fireplace

Figure 9

Figure 10

owner’s information

Smart Thermostat (Transmitter Operation)

Remote dimmer control (Light)**

The Smart Thermostat function adjusts the flame height in accordance to the difference between the set point temperature and the actual room temperatures. As the room temperature gets closer to the set point the Smart Function will modulate the flame down. To activate this function, press the Thermostat Key (Fig. 1) until the word “SMART” appears to the right of the temperature bulb graphic (Fig. 11). To adjust the set temperature, press the Up or Down Arrow Keys until the desired set temperature is displayed on the LCD screen of the Transmitter (Fig. 12). Note. When Smart Thermostat is activated, manual flame height adjustment is disabled.

The auxiliary function controls the AUX power outlet by the dimmable light control. To activate this function use the Mode Key (fig. 1) to index to the AUX icon (fig. 15 & 16). The intensity of the output can be adjusted through six (6) levels. Use the Up/Down Arrow Keys (fig.1) adjust the output level (fig. 16). A single “beep” will confirm reception of the command.
Note: This function is available only with the IFC Control Module.

Figure 11: Smart Flame Function

Figure 12

Figure 15

Figure 16

Fan Speed Control**
If the appliance is equipped with a hot air circulating fan, the speed of the fan can be controlled by the Proflame system. The fan speed can be adjusted through six (6) speeds.To activate this function use the Mode Key (fig.1) to index to the fan control icon (Fig. 13). Use the Up/Down Arrow Keys (fig.1) to turn on, off or adjust the fan speed (fig. 14). A single “beep” will confirm reception of the command.

KEY LOCK
This function will lock the keys to avoid unsupervised operation. To activate this function, press the MODE and UP Keys at the same time (fig. 21). To de- activate this function, press the MODE and UP Keys at the same time.

Figure 13

Figure 14

Figure 18

Regency Bellavista® B41XTCE -11 Gas Fireplace | 15

owner’s information
LOW BATTERY POWER DETECTION Transmitter
The life span of the remote control batteries depends on various factors: quality of the batteries used, the number of ignitions of the appliance, the number of changes to the room thermostat set point, etc. When the Transmitter batteries are low, a Battery Icon will appear on the LCD display of the Transmitter (Fig. 22) before all battery power is lost. When the batteries are replaced this Icon will disappear.

Figure 19

CPI/IPI Switch
This appliance comes equipped with a CPI/IPI switch. (See noted location of CPI/IPI switch)
The functions of both the CPI/IPI switch are as follows:
Continuous pilot (CPI) – A pilot that, once placed in operation, is intended to remain ignited continuously until it is manually interrupted.
Intermittent pilot (IPI) – A pilot that is automatically ignited when an appliance is called on to operate and which remains continuously ignited during each period of main burner operation.The pilot is automatically extinguished when each main burner operating cycle is completed
The mode of the fireplace is easily changed from an intermittent pilot ignition system (IPI) to a continuous pilot ignition system (CPI) by using the silver toggle switch located on the fireplace. (See noted location of CPI/IPI Switch)
The benefits of having CPI are as follows:
-Keeps venting primed for trouble free start-up under colder weather conditions or inversions.
-Keeps the unit glass warm, which decreases the amount of condensation on start-up.
-Provides owners with flexibility to choose a traditional continuous pilot. (7 day/Pilot on Demand)
The primary benefit of having the IPI function is a significant savings on fuel as the pilot will only run when there is a call for heat.
ENABLE / DISABLE functions on the Proflame I remote only. 1. Remove one battery from the remote. 2. Press and hold both the ON/OFF and the MODE button at the same time 3. Reinstall the battery (removed in Step 1) while still holding both buttons (keep holding both
buttons and once all batteries are installed then release the MODE button only). 4. The screen will show CFG. 5. Use the up or down arrow button to program out the function on the remote.
Note: You should never program out the fan (If installed) feature on the remote. It is not possible to remove the thermostat mode on this remote control.

The Surefire switch is located in the right corner of the bottom louver/panel.

16 | Regency Bellavista® B41XTCE -11 Gas Fireplace

installer’sreiqnufoirremmaetinotns

Proflame I Remote Receiver Battery Replacement & Battery Backup if 120V Power is lost within
home
If no fan control module or AC adaptor is installed, 4 AA batteries are mandatory in the remote receiver to operate the appliance when using the remote control.

How to replace/add the batteries on remote receiver (Proflame 1).

Note : If a wall switch cover plate is installed, first remove cover plate by removing 2 small phillips head screws

STEP 1

Move both the left/right slides as shown below.

The battery compartment will be pushed out slightly, to allow to easily extract it

STEP 2

Extract the battery compartment from the remote receiver/battery holder

Replace 4 x AA batteries and insert the battery compartment back into remote receiver/battery holder

STEP 3

Keeping the battery compartment pressed in, close the left slide

Close the right slide

STEP 4 Reinstall wall cover plate with 2 Phillips head screws.
Regency Bellavista® B41XTCE -11 Gas Fireplace | 17

installer’s information

Installation Checklist
1. Locate appliance:
a) Room location (Refer to “Locating Your Gas fireplace” section)
b) Clearances to Combustibles (Refer to “Clearances” section)
c) Mantel Clearances (Refer to “Combustible Mantel Clearances” section)
d) Framing & Finishing Requirements (Refer to “Framing & Finishing” section)
e) Venting Requirements (Refer to “Venting” section)
2. Assemble Top Standoffs and Top Facing Support and Side Nailing Strips (Refer to “Unit Assembly Prior to Installation” Section). Note: Must be done before installing unit into place.
3. Install vent (Refer to “Venting” sections).
4. Wire 120 volt AC power to the supplied receptacle box located on lower left-hand side of appliance. The Duplex receptacle and receptacle cover are also included and will be located in the manual package. Note : This heater does not require 120 volt AC supply for operation of the burner but is highly recommended as a primary power source to eliminate the need for 4 AA batteries. Batteries should only be used as a secondary power source when power is lost within the home. 120 Volt AC power is also required for the optional blower.
5. Install junction box supplied with appliance. Install remote receiver inside of junction box. Hook receiver to wire marked receiver. This will enable operation of the burner. If 120 Volt AC power was brought to appliance, batteries are not required.
6. Make gas connections. Test the pilot. Must be as per diagram (Refer to “Pilot Adjustment” section).
7. Install standard and optional features. Refer to the following sections:
a. Plug AC adaptor into 120V receptacle b. Install 4AA batteries into battery pack
(optional) c. Inner Enamel Panels or Brick Panels
(Required) d. Log Set Installation
e. Standard Flush Door f. Remote Control g. Fan Installation (Optional) h. Safety Screen
8. Final check.

This includes: 1. Clocking the appliance to ensure the correct
firing rate (rate noted on label), after burning appliance for 15 minutes. 2. If required, adjusting the primary air to ensure that the flame does not carbon. First allow the unit to burn for 15-20 min. to stabilize. CAUTION: Any alteration to the product that causes sooting or carboning that results in damage is not the responsibility of the manufacturer.
Locating Your Gas Fireplace
1. When selecting a location for your fireplace, ensure that the clearances are met.
2. The appliance must be installed on a flat, solid, continuous surface, for example a wood, metal or concrete floor or in a raised (on the wall) application. The appliance must be installed on a metal or wood panel extending the full width and depth of the appliance.
3. The B41XTCE Gas Fireplace can be installed in a recessed position or framed out into the room as in A, B, C and D. See Diagram 1.
Diagram 1
A) Flat on Wall B) Flat on Wall Corner C) Recessed into Wall/Alcove

D) Corner 4. This appliance is Listed for bedroom instal-
lations using the standard Remote (millivolt thermostat system). Some areas may have further requirements, check local codes before installation.
5. The B41XTCE Gas Fireplace is approved for alcove installations, see “Clearances” section for details.
6. We recommend that you plan your installation on paper using exact measurements for clearances and floor protection before actually installing this appliance. Have an authorized inspector, dealer, or installer review your plans before installation.
Note: For vent terminations refer to “Exterior Vent Termination Locations” section.

18 | Regency Bellavista® B41XTCE -11 Gas Fireplace

installation

Clearances

The clearances listed below are minimum distances unless otherwise stated:
A major cause of chimney-related fires is failure to maintain required clearances (airspace) to combustible materials. It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions.

Caution Requirements The top, back and sides of the fireplace are defined by
standoffs. The metal ends of the standoff may NOT be recessed into combustible construction.
B41XTCE Clearance Requirements

WARNING
Fire hazard is an extreme risk if these clearances (airspace) to combustible materials are not adhered to. It is of greatest importance that this fireplace and vent system be installed only in accordance with these
instructions.

Clearance: A: Mantel Height (min.) B: Sidewall C: Ceiling D: Mantel Depth (max.)
E: Alcove Width F: Alcove Depth Notes:

Dimension 17-9/16″ (446 mm)
9″ (229 mm) 36-5/8″ (930 mm)
12″ (304 mm)
60″ (1524 mm) 36″ (914 mm)
0″

Measured From: Top of Fireplace Opening
Side of Fireplace Opening Top of Fireplace Opening
25-13/16″ (651 mm) from Top of Fireplace Opening
Wall to Wall (Minimum) Front to Back Wall (Maximum) No Hearth Required

NOTE: A 16″ deep non-combustible hearth pad is recommended for hardwood flooring and carpet.

C
D F
A

E
Diagram 2
E
F

Alcove

Diagram 4

C F

E Close to Ceiling

Diagram 3

Minimum Vent Clearances to Combustibles

Horizontal Top Horizontal Side Horizontal Bottom Vertical Vent

3″ (76mm) 2 ” (51mm) 2″ (51mm) 2″ (51mm)

Regency Bellavista® B41XTCE -11 Gas Fireplace | 19

installation
Mantel Clearances
Due to the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from top of front facing are shown in the diagram on the right. Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a
non-combustible board. The non-combustible mantel when installed at a lower overall height may not be lower than 6 inches from the top of the fireplace opening.
Note: Ensure the paint that is used on the mantel and the facing is “heat resistant” or the paint may discolour.
Mantel Clearances
14 12 10 8 6 4 2

0

12″ 24

12

B

Combustible

7″

1″

C

6″

D

Non-combustible Header
(steel stud) on edge
Non-combustible
Standoff

0
Inches

A
To Floor

Top of Fireplace Opening

Mantel Clearances B41XTCE
From Top of Fireplace Opening

A

B

C

D

32-11/16″ (830 mm)

25-13/16″ (656 mm)

22-1/16″ (560 mm)

17-9/16″ (446 mm)

20 | Regency Bellavista® B41XTCE -11 Gas Fireplace

Mantel Leg Clearances

installation

9″ Side Wall (Measured from side of
Fireplace Opening)

Mantel leg
1-1/2″
Mantel leg
3″

4″

Diagram 5

7″
Allowable mantel leg projection.

Non-Combustible Requirements

46-11/16″ [1186mm]

NON-COMBUSTIBLE BOARD SUPPLIED W/UNIT
No Combustible Materials in this Area

6″ [152mm] 11-5/8″ [295mm]

44-1/4″ [1124mm] 29″ [737mm] 50-1/4″ [1276mm]

NO FACING OR FINISHING MATERIAL
IN THIS AREA

4-1/8″ [105mm]

38-7/16″ 976mm

3-9/16″ [91mm]

Diagram 6

NOTE: The 6″ x 46-11/16″ supplied with the unit is secured directly above the unit as shown above.
**All other non-combustible material is supplied by others.

Regency Bellavista® B41XTCE -11 Gas Fireplace | 21

installation

Framing

Framing Dimensions

Description

B41XTCE

M

Framing Width

47-1/4″(1200 mm)

N

Framing Height

49-1/2″ (1257 mm)

O (Rear Vent)

Framing Depth – Rear Vent

26-1/2″ (673 mm)

O (Top Vent)

Framing Depth – Top Vent

25-7/8″ (657 mm)

P

Corner Facing Wall Width

65-1/4″ (1657 mm)

Q

Corner Facing Wall Width

91-11/16″ (2329 mm)

R (Rear Vent)

Framed Chase Ceiling – Rear

49-1/2″ (1257 mm)

R (Top Vent)

Framed Chase Ceiling – Top

54-1/2″ (1384 mm)

S (Rear Vent)

Vent Centerline Height – Rear

28-1/2″ (724 mm)

S (Top Vent)

Vent Centerline Height – Top

47-1/2″ (1207 mm) Rigid / Flex

T

Gas Connection Height

1-1/2″ (38 mm)

U

Gas Connection Inset

5″ (127 mm)

V

Gas Connection Width

3-1/4″ (82 mm)

W

Non-Combustible Top Height

6″ (152 mm)

** Important: Framing height requires consideration of the hearth depth. Dimension N = N + the thickness of the installed hearth.

R

Non-Combustible Header
(steel stud) on edge
N
M

Drywall (or other facing)
W

Non-Combustible Header
(steel stud) on edge
Non-Combustible Facing

11″ (279mm) dia. Hole through
wall Vent.
O

S S
P

Q
Diagram 7 22 | Regency Bellavista® B41XTCE -11 Gas Fireplace

T
UV
Opening for gas connection

installation

Framing & Finishing
1. Frame in the enclosure for the unit with framing material.
Note:When constructing the framed opening, please ensure there is access to install the gas lines when the unit is installed.
2. For exterior walls, insulate the enclosure to the same degree as the rest of the house; apply vapour barrier and drywall, as per local installation codes. (Do not insulate the fireplace itself.)
WARNING: Failure to insulate and add vapor barriers to the inside of the exterior wall will result in operational and performance problems including, but not limited to: excessive condensation on glass doors, poor flame package, carbon, blue flames, etc. These are not product-related issues.
3. The unit does not have to be completely enclosed in a chase. You must maintain clearances from the vent to combustible materials: See “Clearances” section. Combustible materials can be laid against the side and back standoffs and the stove base.
4. Tile Finish Option 1: Drywall may be installed only in areas as shown below to create a surface to apply finishing materials such as tile, slate, etc.
5. Tile Finish Option 2: If applying a non-combustible finishing material (tile, slate, etc.) the material can be installed directly onto the metal surface (clean front) of the unit in the area shown below.
Tile Finish

Non-combustible
Finishing Material only (ie. tile)

Combustible Material (ie: 1/2″ Drywall)
Non-combustible Material (6″ x 46-11/16″) Supplied with Unit
Nailing Strip -1/2″ back from unit face

29″ [737mm]

Ensure finished material is brought to lip

1-1/2 (38mm)

Clean Finish

38-7/16″ 976mm

Diagram 8

Non-combustible Finishing Material only (ie. tile)

Combustible Material (ie: 1/2″ Drywall)
Diagram 9

6. If applying a non-combustible facing it may be installed over the metal surface (clean front) of the unit in the area shown below.

WOOD STUD

Combustible Material

6″ [152mm]

NON COMBUSTIBLE BOARD SUPPLIED W/UNIT
46-11/16″ [1186mm]

1/2″ DRYWALL DO NOT EXTEND DRYWALL ONTO METAL SURFACE OF UNIT.
NON-COMBUSTIBLE FACING FOR CLEAN LOOK (ie. painted finish) (SUPPLIED BY OTHERS)

Non-combustible Finishing Material

Non-combustible Material (6″ x 46-11/16″) Supplied with Unit
Nailing Strip -flush with unit face

1/2” DRYWALL DO NOT EXTEND DRYWALL ONTO METAL SURFACE OF UNIT

44-1/4″ [1124mm]

1/2″ DRYWALL DO NOT EXTEND DRYWALL ONTO METAL SURFACE OF UNIT

Ensure finished material is brought to lip

1-1/2 (38mm)

Combustible and Non-combustible Facing and Finishing Materials around unit.

Diagram 10

Non-combustible Finishing Material

Combustible Material

Diagram 11

Note: The 6″ x 46-11/16″ non-combustible material supplied with this unit can be replaced if trying to achieve a clean finish. A large piece of noncombustible material (ie. 4′ x 8′ x 1/2″ can be used to eliminate taped seams on or near unit).

Regency Bellavista® B41XTCE -11 Gas Fireplace | 23

installation

7. Non-combustible material (ie. tile, slate, etc.) may be brought up to the edge of the glass door of the unit. Minimum clearances must be adhered to, this will assure ease of glass door removal and access to the lower panel.
NOTE: Non-combustible finishing materials may be of any thickness desired.

46-11/16″ [1186mm]

NON-COMBUSTIBLE BOARD SUPPLIED W/UNIT
No Combustible Materials in this Area

6″ [152mm] 11-5/8″ [295mm]

NO FACING OR FINISHING MATERIAL
IN THIS AREA

No Combustible Materials in this Area
J Style trim or metal corner bead may be used to finish edges

29″ [737mm] 44-1/4″ [1124mm] 29″ [737mm] 50-1/4″ [1276mm]

4-1/8″ [105mm]

38-7/16″ 976mm

3-9/16″ [91mm] Diagram 12

Minimum Clearances for Finishing Materials
IMPORTANT FINISHING DETAIL NOTE:

Before placing unit into final position – it is important to know the total thickness / height of finished hearth (tile, carpet, etc.) The base of the fireplace, 4 sided faceplate or mantel should be level or higher than the finished hearth height.

38-7/16″ 976mm

Diagram 13

Trim materials

Note: All non-combustible facing material should butt up cleanly
to the flanges around the firebox opening.
Rough edges may be visible from an angle.
To maintain a clean finished edge – facing material edges may be finished with a J-style trim or metal corner bead (both materials available at your local building or hardware store).
IMPORTANT: Materials used must be NON-COMBUSTIBLE.

Diagram 14

24 | Regency Bellavista® B41XTCE -11 Gas Fireplace

installation

Unit Assembly Prior to Installation

Before You Start
The Top Nailing Support, the Side Nailing Strips, the 2 Top Standoffs and the Flue Collar must be correctly positioned and attached before the fireplace is moved into position.

Top Standoff Assembly
The top standoffs are shipped in a flat position and must be folded into shape and attached.
1. Remove the standoffs from the fireplace top.
2. Take each standoff and bend into the correct shape. Bend up at the bend lines until the screw holes in the standoff and the pre-punched screw holes on the fireplace top line up.
3. Attach the standoff securely to the top with 2 screws per standoff (on opposite corners).

Diagram 15

Nailing Strips
1. There are 8 (eight) side nailing strips and one top nailing strip available on the unit. One set of four (4) are for a clean finish installation, the other set are for a tile finish installation as they are set back 1/2″ (13 mm). The top nailing strip is adjustable to 1/2″ (13 mm).
2. Bend the required four (4) nailing strips to 90º.
3. Attach top nailing strip with one (1) screw (located at the back of the nailing strip). Adjust to required position, flush or back 1/2″ and tighten screw.

Adjustable Top Nailing Strip Nailing strip for Clean Finish (set flush with unit)
Nailing strip for Tile Finish (setback 1/2″)
Diagram 16

Diagram 17

Nailing strip for Tile Finish (setback 1/2″)
Nailing strip for Clean Finish (set flush with unit)

Regency Bellavista® B41XTCE -11 Gas Fireplace | 25

installation
Wall Mount On / Off Switch and Remote Receiver Installation Required for all installations – including Proflame remote controls
IMPORTANT INSTALLATION NOTE:
The Receiver must be placed inside the supplied (Low Voltage) junction type wall box and installed into the wall only.
DO NOT INSTALL WITHIN THE CONFINES OF THE FIREPLACE.
Remote Receiver Installation
1. Install the low voltage junction box to the framing, at desired location within 9 ft. (2.7 meters) from fireplace. 2. Feed the 12 pin connector through the opening at back of junction box. 3. Connect the 12 pin connector to the back of the receiver. 4. Install the Receiver in the Low Voltage Junction box. 5. Insert the 4 AA type batteries in the battery compartment with the correct polarity (only required if no fan
control module or AC adaptor is installed). 6. Place the slider into the cover plate. 7. Put the R1eceiver switch in the “OFF” position, to allow correct lineup for slider switch. 8. Make sure the Receiver and cover plate words “ON” and “UP” are on the same side. 9. Align the slider with the switch on the Receiver and couple the switch into the slider. 10. Align the screw holes. 11. Using the two (2) screws provided secure the cover plate to the Receiver.
Proflame Receiver

ON

2

REMOTE

OFF

Receiver 12 Pin Connector for mV GT Systems TH/TFTH Connections Only
6

1

3

2

4 5

Item Part No.

1

N/A

2

911-335

911-343

3

911-338/P

4

N/A

5

910-369

6

911-032

Description Slider Switch (included with wall plate) Wall Plate – White Wall Plate – Black Remote Receiver J-Box Low Voltage Junction Box Remote Receiver Wire Harness

26 | Regency Bellavista® B41XTCE -11 Gas Fireplace

10 ft. wire harness with 12 pin connector

Diagram 1

installation

Conversion to Top Vent

Note: This conversion must be done prior to the unit being placed in position. The unit comes equipped as a rear vent unit. These instructions are to be used, only if the unit is going to be top vented.

Top Collar Assembly Kit Includes:

4. From the outside rear of the firebox: remove the intake collar assembly. Remove the 4 – 1/4″ x 1/2″ screws.

1

Intake Collar Assembly with Gasket

1

Intake Cover Plate with Gasket

1

Top/Rear Exhaust Assembly with Gasket

1

Baffle Plate

Exhaust Assembly

29

1/4″ x 1/2″ Screws (4 spares)

1

Restrictor

1

Intake Collar Gasket (spare)

Intake Collar Assembly

1

Exhaust Assembly Gasket (spare)

1

Insulation Plate Cover

Diagram 21

1

Insulation Filling

1. Remove the door by releasing the spring hooks at the bottom and lifting the door up off the door frame.

5. From the outside top of the firebox: remove top insulation cover plate – by removing 2 screws as shown and discard.

Swing door out from the bottom
and lift up off of door frame

Diagram 18

Flush Door

Diagram 22
6. From the outside top of the firebox: slide the square piece of insulation out and discard.

2. From inside the firebox, remove the baffle plate by removing 4 screws – remove top front screw first.

Diagram 23

Baffle Plate

Diagram 19

7. From the outside top of the firebox: remove the intake cover plate by removing the 4 – 1/4″ x 1/2 ” screws.

3. From the inside of the firebox: remove the exhaust assembly by removing the 10 screws.

Diagram 20

Diagram 24
Before proceeding to Step 8, inspect condition of all gaskets. DO NOT install parts with damaged gaskets. Replace if necessary with spare gaskets supplied.
Regency Bellavista® B41XTCE -11 Gas Fireplace | 27

installation

8. From the outside top of the firebox: completely remove the insulation under the cover plate as shown and discard.

11. From the outside top of the firebox: install the intake collar assembly.
Secure with 4 – 1/4″ x 1/2″ screws. Ensure all screws are tight, but do not over tighten. All 4 screws must be used.

Diagram 29

Diagram 25

Exhaust Assembly

9. From the outside back of the firebox: locate the insulation deflector and bend completely upwards flat against the back of firebox.
IMPORTANT: If the insulation deflector is not bent flat against the back of the firebox this will block air intake which will affect the unit’s performance.
Insulation Deflector

Intake Collar Assembly
12. From the outside rear of the firebox: install the intake cover plate with 4 – 1/4″ x 1/2″ screws. Ensure all screws are tight, but do not over tighten. All 4 screws must be used.

Diagram 26

Diagram 30 13. Set vent restrictor accordingly–see next page. 14. From inside the firebox: reinstall the baffle plate from step 2.

View Front of Firebox
10. From the inside of the firebox: place the exhaust assembly into position as shown in Diagram27 and secure with 10 – 1/4″ x 1/2″ screws (Diagram 28). Ensure all screws are tight, but do not over tighten. All 10 screws must be used.

Diagram 27

Diagram 28 28 | Regency Bellavista® B41XTCE -11 Gas Fireplace

installation

Venting Introduction
The B41XTCE uses the “balanced flue” technology coaxial system. The inner liner vents products of combustion to the outside while the outer liner draws outside combustion air into the combustion chamber thereby eliminating the need to use heated room air for combustion and losing warm room air up the chimney.
Note: These flue pipes must not be connected to any other appliance.
The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate solid fuel or gas burning appliance. Each direct vent gas appliance must use its own separate vent system. Common vent systems are prohibited.

Vent Restrictor & Baffle Installation
Note: The vent restrictor & baffle must be installed prior to Optional Panel Installation.

1. Determine the venting configuration.
2. Go to venting arrangements section to determine if a vent restrictor setting is required. Note: The vent restrictor does not apply to rear vent applications.
3. Remove baffle plate. See Diagram 31.
4. Align the vent restrictor plate to the required vent restrictor position as per diagram 32.
5. Once the vent restrictor plate is in the required position, secure with 2 – 1/4″ x 1/2″ screws. Ensure all screws are tight, but do not over tighten. (See diagram 33).

NO VENT RESTRICTOR Factory setting
SET 1 THIS HOLE SETS THE
VENT RESTRICTOR AT 3-1/2″

SET 2 THIS HOLE SETS THE
VENT RESTRICTOR AT 2-1/2″

Diagram 31

Vent Restrictor installed on Top Exhaust Assembly

6. From inside the firebox, install the baffle plate with 4 – 1/4″ x 1/2 ” screws. Ensure all screws are tightly secure, but do not over tighten.

SET 3 THIS HOLE SETS THE
VENT RESTRICTOR AT 1-1/2″

Baffle Plate

Diagram 32

Diagram 33 Regency Bellavista® B41XTCE -11 Gas Fireplace | 29

installation
Exterior Vent Termination Requirements

Minimum Clearance Requirements

Canada1

USA2

A Clearance above grade, veranda, porch, deck, or balcony

12″(30cm)

12″(30cm)

B Clearance to window or door that may be opened C Clearance to permanently closed window

12″(30cm) *

9″ (23cm) *

D Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet (61cm)from the center line of the terminal (check with the local code)

24″(60cm)

E Clearance to unventilated soffit

19-1/2″(50cm)

24″(60cm) 20″(51cm)

F Clearance to outside corner: with AstroCap XL Termination Cap.

13″(33cm)

13″(33cm)

Clearance to outside corner: with all other approved Termination Caps.

13″(33cm)

13″(33cm)

G Clearance to inside corner: with AstroCap XL Termination Cap

5-1/2″(14cm)

5-1/2″(14cm)

Clearance to inside corner: with all other approved Termination Caps.

7″(18cm)

7″(18cm)

H Clearance to each side of center line extended above meter/regulator assembly

36″(90cm)a

J Clearance to service regulator vent outlet

36″(90cm)

K Clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance L Clearance to a mechanical air supply inlet

3′ (91cm) above if within 10′ (3m) horizontally.

12″(30cm) 72″(1.8m)

9″ (23cm) 36″(90cm)b

M Clearance above paved sidewalk or a paved driveway located on public property

84″(2.1m)

N Clearance under veranda, porch, deck, or balcony

12″(30cm)

1 In accordance with current CSA B149.1, Natural Gas and Propane Installation Code 2 In accordance with the current ANSI Z223.1/NFPA 54, National Fuel Gas Code

A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings

Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor

  • a

Clearance in accordance with local 3 feet (91cm) within a height of 15

installation codes and the requirements of the gas feet (4.5m) above the meter / regulator assembly

supplier

b 3 feet (91cm) above – if within 10 feet (3m) horizontally

30 | Regency Bellavista® B41XTCE -11 Gas Fireplace

installation

5″ x 8″ Rigid Pipe – Cross Reference Chart only
Components from different Manufacturers may not be mixed. Not all Rigid Pipe components are available directly from FPI. Note: Olympia Ventis DV venting is only approved for certain models. See list of approved models in cross- reference chart.

Description
6″ Pipe Length-Galvanized 6″ Pipe Length-Black 9″ Pipe Length-Galvanized 9″ Pipe Length-Black 12″ Pipe Length-Galvanized 12″ Pipe Length-Black 18″ Pipe Length-Galvanized 18″ Pipe Length-Black 24″ Pipe Length-Galvanized 24″ Pipe Length-Black 36″ Pipe Length-Galvanized 36″ Pipe Length-Black 48″ Pipe Length- Galvanized 48″ Pipe Length-Black 60″ Pipe Length-Galvanized 60″ Pipe Length- Black

Simpson Direct Vent Pro®
58DVA-06 58DVA-06B 58DVA-09 58DVA-09B 58DVA-12 58DVA-12B 58DVA-18 58DVA-18B 58DVA-24 58DVA-24B 58DVA-36 58DVA-36B 58DVA-48 58DVA-48B 58DVA-60 58DVA-60B

Adjustable Length 3″-10″-Galvanized N/A

Adjustable Length 3″-10″-Black

N/A

Adjustable Length 11″-14″ -Galvanized Disc. – See 58DV-08A

Adjustable Length 11″-14″ -Black

Disc. – See 58DV-08B

Extension Pipe 17″-24″ -Galvanized

Disc. – See 58DV-16A

Extension Pipe 17″-24″ -Black

Disc. – See 58DV-16AB

Adjustable Length 8-1/2″-Galvanized 58DVA-08A*

Adjustable Length 8-1/2″-Black

58DVA-08AB

Extension Pipe 16″-Galvanized

58DVA-16A *

45º Elbow-Galvanized 45º Elbow-Black 45º Elbow Swivel-Galvanized 45º Elbow Swivel-Black 90º Elbow-Galvanized 90º Elbow-Black 90º Elbow, Swivel-Galvanized 90º Elbow, Swivel-Black 90º Starter Elbow, Swivel-Galvanized Adaptor*

58DVA-E45 58DVA-E45B Disc. – See 58DVA-E45 Disc.-See 58DVA-E45B 58DVA-E90 58DVA-E90B Disc. – See 46DVA-E45 Disc. – See 46DVA-E45 N/A N/A

Ceiling Support Cathedral Support Box Wall Support/Band Offset Support Wall Thimble-Black Wall Thimble Support/Ceiling Support Firestop Spacer Trim Plate- Black

58DVA-DC 58DVA-CS 58DVA-WS 58DVA-ES 58DVA-WT 58DVA-DC 58DVA-FS 58DAV-WFS

  • Not available from Regency

*Selkirk Direct TempTM
5DT-6 5DT-6B 5DT-9 5DT-9B 5DT-12 5DT-12B 5DT-18 5DT-18B 5DT-24 5DT-24B 5DT-36 5DT-36B 5DT-48 5DT-48B N/A N/A
N/A N/A 5DT-AJ 5DT-AJB N/A N/A N/A N/A N/A
5DT-EL45 5DT-EL45B N/A N/A 5DT-EL90S 5DT-EL90SB N/A N/A N/A N/A
5DT-CS 5DT-CSS 5DT-WS/B 5DT-OS 5DT-WT N/A 5DT-FS 5DT-TP

*Metal-FabTM Sure Seal
5D6 5D6B N/A N/A 5D12 5D12B 5D18 5D18B 5D24 5D24B 5D36 5D36B 5D48 5D48B N/A N/A
5DAL 5DALB N/A N/A N/A N/A N/A N/A N/A
5DT-EL45 5DT-EL45B N/A N/A 5DT-EL90S 5DT-EL90SB N/A N/A N/A N/A
5DSP 5DRS 5DWS N/A 5DWT N/A 5DFS 5DCP

*ICC Excel Direct
TC-5DL6 TC-5DL6B TC-5DL9 TC-5DL9B TC-5DL1 TC-5DL1B TC-5DL18 TC-5DL18B TC-5DL2 TC-4DL2B TC-5DL3 TC-5DL3B TC-5DL4 TC-5DL4B N/A N/A
TC-5DLT TC-5DLTB N/A N/A N/A N/A N/A N/A N/A
TE-5DE45 TE-5DE45B N/A N/A TE-5DE90 TE-5DE90B N/A N/A N/A N/A
TM-5RDS TM-5SS TM-5WS TM-5OS N/A N/A TM-5LS TM-5TP

*Olympia Ventis DV***
VDV-0506 VDVB-0506 VDV-0509 VDVB-0509 VDV-0512 VDVB-0512 VDV-0518 VDVB-0518 VDV-0524 VDVB-0524 VDV-0536 VDVB-0536 N/A N/A N/A N/A
N/A N/A N/A N/A N/A N/A N/A N/A N/A
VDV-EL0545 VDVB-EL0545 N/A N/A VDV-EL0590 VDV-EL0590 N/A N/A N/A VDV-UAA05
VDV-CSR05 DV-CSS05 VDV-WS05 N/A VDV-WPT05 N/A VDV-FS05 VDV-WTC05

Regency Bellavista® B41XTCE -11 Gas Fireplace | 31

installation

Description Attic Insulation Shield 12″

Simpson Direct Vent Pro® 58DVA-IS*

Basic Horizontal Termination Kit (A) Horizontal Termination Kit (B) Vertical Termination Kit

N/A 58DVA-KHA 58DVA-VHA

*Selkirk Direct TempTM
N/A
5DT-HKA 5DT-HKB 5DT-VKC

*Metal-FabTM Sure Seal
N/A
N/A N/A N/A

*ICC Excel Direct
N/A
TM-5HTK TM-5HTK N/A

*Olympia Ventis DV***
VDV-AIS05
VDV-KW05 VDV-K05 N/A

High Wind Vertical Cap

58DVA-VCH

High Wind Horizontal Cap

N/A

Horizontal Square Termination Cap N/A

Vertical Termination Cap

N/A

Storm Collar

58DVA-SC

N/A N/A 5DT-HHC 5DT-HVC 5DT-SC

N/A N/A 5DHT 5DVT 5DSC

TM-5VT TM-5DHT TM-5HT N/A TM-SC

VDV-VCH05 N/A VDV-HC05 N/A VDV-SC05

Adjustable Flashing 0/12-6/12 Adjustable Flashing 6/12-12/12

58DVA-F6 58DVA-F12

5DT-AF6 5DT-AF12

5DF 5DF1-2

TF-5FA TF-5FB

VDV-F0506 VDV-F0512

Vinyl Siding Standoff Vinyl Siding Shield Plate

58DVA-VSS N/A

5DT-VS 5DT-VSP

5DVS N/A

TM-VSS N/A

VDV-SSO N/A

Snorkel Termination 14″

58DVA-SNK14

N/A

Snorkel Termination 36″

58DVA-SNK36*

N/A

N/A

TM-5ST14

N/A

N/A

TM-5ST36

N/A

Restrictor Disk

N/A

Colinear Flex Connectors

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

  • Not available from Regency

FPI 946-604/P 770-994 **946-606

Simpson Direct Vent or Astro Cap -Vent Guard (Optional) Rigid Pipe Adaptor (Must use with all rigid piping) Starter collar reducer 5″ x 8″ to 4″ x 6-5/8″ (B36XTE, B36XTCE ONLY)

946-623/P **946-506/P 946-625

AstroCap XL Horizontal Cap Vent Guard (Optional) Vinyl Siding Standoff – AstroCap XL

***Olympia Ventis DV applicable for the following units only when using 5″ x 8″ vent system: B36XTE, B 36XTCE, B41XTE, B41XTCE, CB60E, CV60E, CV72E, U1500E

Note: When using Metal-Fab Sure Seal Rigid Piping – please note that the Adaptor (5DDA) must be used in conjunction with FPI Rigid Pipe Adaptor (770-994). ** Not available/applicable for the following units: B41XTE, B41XTCE, CB60E, CV60E, CV72E, HZ54E, U1500E

Offset Pipe Selection: Use this table to determine offset pipe lengths.

Pipe Length (L)

5″ x 8″ Venting

Run (X)

Rise (Y)

0″ (0mm)

5-11/16″ (144mm)

15-5/16″ (389mm)

6″ (152mm)

8-13/16″ (224mm)

18-7/16″ (468mm)

9″ (229mm)

10-15/16″ (278mm)

20-9/16″ (522mm)

12″ (305mm)

13″ (330mm)

22-11/16″ (576mm)

24″ (610mm) 36″ (914mm) 48″ (1219mm)

21-7/16″ (697mm) 29-13/16″ (757mm)
38-1/4″ (972mm)

31-1/16″ (789mm) 39-7/16″ (1002mm) 47-7/8″ (1216mm)

For specific instructions on venting components – visit the manufacturers website listed below.
Simpson Direct Vent Pro: www.duravent.com
Selkirk Direct-Temp: www.selkirkcorp.com
Metal-Fab Sure Seal: www.mtlfab.com
Industrial Chimney Company: www.icc-rsf.com
Olympia Ventis DV: www.olympiachimney.com
Note: Horizontal runs of vent must be level, or have a 1/4″ rise for every 1 foot of run towards the termination. Never allow the vent to run downward – this could cause high temperatures and may present a possible fire hazard.

32 | Regency Bellavista® B41XTCE -11 Gas Fireplace

installation

Rigid Pipe Venting Systems Basic Horizontal & Vertical Terminations

Rigid Pipe Vent Systems offer a complete line of component parts for installation of both horizontal and vertical installations. Many items are offered in decorative black, as well as galvanized finish.
The minimum components required for a basic Horizontal Termination are:
1 AstroCap XL Termination Cap 1 90o Elbow 1 Rigid Pipe Adaptor 1 Wall Thimble 1 Length of rigid pipe to suit wall thickness
The minimum components required for a basic Vertical Termination are:
1 Vertical Termination Cap 1 Rigid Pipe Adaptor 1 Lengths of pipe to adequately
penetrate roof 1 Ceiling Firestop 1 Flashing 1 Storm Collar
Wall thickness is measured from the back standoffs to the inside mounting surface of termination cap. For siding other than vinyl, furring strips may be used, instead of a vinyl siding standoff, to create a level surface to mount the vent terminal. The Terminal must not be recessed into siding. Measure the wall thickness including furring strips.
If a Vinyl Siding Standoff is required (it must be used with vinyl siding), measure to outside surface of wall without siding and add 2 inches.

Vertical Termination

A

Cap

Storm Collar

Flashing

Ceiling Firestop

Vinyl Siding Standoff (Optional)

B
Astrocap (946-623/P)

Pipe Length

Wall Thimble Pipe Length 90o Elbow

Pipe Length

Rigid Pipe Adaptor

Diagram 34

WARNING:
Do not combine venting components from different venting systems.
Exception: However, use of the AstroCap XLTM is acceptable with all systems.
This product has been evaluated by Intertek when using a rigid pipe adaptor and use of any of the specific chimney systems listed in this manual. Use of these systems with the rigid pipe adaptor is deemed acceptable and does not affect the Intertek WHI listing of these components.

Alternate Horizontal Termination Caps
HOT
Alternate Snorkel Termination Cap

When using Rigid Vent other than Simpson Dura-Vent, 3 screws must be used to secure rigid pipe to adaptor.
Diagram 35

The Regency AstroCapTM and Regency Riser Vent terminal are certified for installations using Regency venting systems as well as any specific chimney systems listed in this manual. AstroCapTM is a proprietary trademark of Regency Fireplace Products.
Regency Bellavista® B41XTCE -11 Gas Fireplace | 33

installation
Venting Arrangements for Horizontal Terminations – Flex Vent or Rigid Pipe 5″ x 8″

The diagrams show all allowable combinations of vent runs with 5″ x 8″ venting using the Regency direct vent system or rigid vent system. A vent guard should be used whenever the termination is lower than the specified minimum or as per local codes.
For horizontal terminations the Regency Direct Vent Flex System may be used for installations up to a maximum continuous vent length of 10 ft (3.0 m).
Note: Must use optional rigid pipe adaptor (Part # 770-994) when using Rigid Pipe vent systems.
· Maintain clearance to combustibles. · Horizontal vent must be supported every 3 feet. · Firestops are required at each floor level and whenever passing through a wall.

Horizontal (Feet)

2

4

6

8

Horizontal (Feet)

2

4

6

8

0

0

12

10

8

Vertical Height (Feet)
Rigid or Flex 47-1/2″ (1.2m)
Vertical Height (Feet) 28 – 1/2″(0.7m)

8
6
4
2
Max. 36″(0.9m)
0 Diagram 36
Vent Restrictor – Set 1

6
Max. 36″(0.9m)
4
2
0
Diagram 37 Factory Setting – No Restrictor Required

IMPORTANT
Must use Rear Venting Deflector packaged with unit in rear vent horizontal termination applications.

Rear Venting Deflector Installation For Rear Vented Horizontal Terminations

The Rear Vent Deflector comes with the unit. When the unit is shipped, the deflector is slightly tucked underneath the top nailing strips located at the top of the firebox.
NOTE: The Rear Venting Deflector must be installed before the unit is put in place.
Rear Venting Deflector

Rear Venting Deflector

1. Secure the rear venting
deflector to the wall thimble using 2 screws as shown.
Ensure to use the same screw
holes as the wall thimble.

Diagram 38 34 | Regency Bellavista® B41XTCE -11 Gas Fireplace

Diagram 39

installation
Horizontal Terminations – Flex Vent 5″ x 8″
These venting systems, in combination with the B41XTCE Direct Vent Gas Fireplace, has been tested and listed as a direct vent heater system by Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in “Exterior Vent Termination Locations” section.
Regency® Direct Vent (Flex) System 4 foot Termination Kit (Part# 946-615) or 10 foot Termination Kit (Part# 946-616) includes all the parts needed to install the B41XTCE with a either a top or rear vent.

FPI Kit # #946-615

946-618

946-616

Length 4 Feet
6 Feet
10 Feet

Contains:

  1. 8″ flexible liner (Kit length) 2) 5″ flexible liner (Kit length) 3) spring spacers 4) thimble 5) AstroCap XL termination cap 6) screws 7) tube of Mill- Pac 8) plated screws 9) S.S. screws #8 x 1-1/2″ drill point 10) vinyl siding standoff

Diagram 40
Notes: 1) Liner sections should be continuous without any joints or seams. 2) Only Flex pipe purchased from Regency may be used for Flex installations. 3) Regency® Direct Vent System (Flex) is only approved for horizontal termina-
tions.
NOTE: If longer runs are required the FPI Direct Vent system (Flex) #946-616 includes all parts needed to install the B41XTCE with a maximum 10′ run.

IMPORTANT
Must use Rear Venting Deflector packaged with unit in rear vent horizontal termination applica-
tions.

Regency Bellavista® B41XTCE -11 Gas Fireplace | 35

installation
Horizontal Terminations – Rigid Pipe 5″ x 8″

Horizontal Termination

A

Top Vent – No Vertical Rise

· When venting with a 90° elbow directly off the unit

Flex vent or approved Rigid Vent System

· Max. 3 ft. horizontal run

B

Rear Vent w/ Horizontal Termination

· Max. 3ft. horizontal run

A

Vinyl Siding Standoff (Optional)

Horizontal Termination
Cap

Wall Thimble

Pipe Length 90o Elbow Rigid Pipe Adaptor

B

Vinyl Siding

Standoff (Optional)

Horizonta Termination
Cap

Wall Thimble

Pipe Length Rigid Pipe Adaptor

Diagram 41

Diagram 42
IMPORTANT Must use Rear Venting Deflector packaged with unit
in rear vent horizontal termination applications.

36 | Regency Bellavista® B41XTCE -11 Gas Fireplace

Horizontal Terminations Two (2) 90o Elbows (Rigid Pipe 5″ x 8″)

installation

H1

One 90o elbow = Two 45o elbows.

Option A) B) C) D) E) F)

V
0′ Min. 1′ Min. 2′ Min. 3′ Min. 4′ Min. 5′ Min.

H + H1 2′ Max. 3′ Max. 4′ Max. 5′ Max. 6′ Max. 7′ Max.

With these options, maximum total pipe length is 30 feet with minimum
of 6 feet total vertical
and maximum 8 feet total horizontal. Please note minimum 1 foot between 90o
elbows is required.

G)

6′ Min. 8′ Max.

No Vent Restrictor Installed

Lengths do not include elbow indicated.

Must use rigid pipe adaptor #770-994.

Horizontal terminations Three (3) 90o Elbows (Rigid Pipe 5″ x 8″)
H1

V1

One 90o elbow = Two 45o elbows.

Option A) B) C) D) E) F) G)

V
0′ Min. 1′ Min. 2′ Min. 3′ Min. 4′ Min. 5′ Min. 6′ Min.

H
1′ Max. 2′ Max. 2′ Max. 2′ Max. 3′ Max. 4′ Max. 5′ Max.

V + V1 1′ Min. 3′ Min. 5′ Min. 7′ Min. 9′ Min. 10′ Min. 11′ Min.

H + H1 2′ Max. 3′ Max. 4′ Max. 5′ Max. 6′ Max. 7′ Max. 8′ Max.

With these options, maximum total pipe length is 30 feet
with minimum of 6
feet total vertical and
maximum 8 feet total horizontal. Please note
minimum 1 foot between 90o elbows is required.

H) 7′ Min. 6′ Max. 12′ Min. 9′ Max.

No Vent Restrictor Installed

Lengths do not include elbow indicated.

Must use rigid pipe adaptor #770-994.

H

V

Diagram 43
H V

Diagram 44 Regency Bellavista® B41XTCE -11 Gas Fireplace | 37

installation
Horizontal Terminations – AstroCap XL & Rigid Rear Vent Kit for Corner Installations – Rigid Pipe 5″ x 8″

Designed for a minimum vent configuration when using a rear vent application with a horizontal termination in a corner installation.

Kit# 946-612 Includes: 1 AstroCap XL 1 Rigid Pipe Adaptor 1 Vinyl Siding Standoff (Optional) 1 Wall Thimble
1 6″ Galvanized Rigid Pipe 1 8-1/2″ Galvanized Pipe Extension 1 45º Galvanized Elbow 1 90ml MillPac

946-623/P 770-994 946-625
58DVA-WT 58DVA-06 58DVA-08A 58DVA-E45 948-128

Placement of the Unit into the Corner

Back Top Corner of Unit to Wall

3″

Inside Corner out along the Wall

65-1/4″

Across the Face of the Unit, Wall to Wall

91-11/16″

A – Clearance to Outside Corner

13″

B – Clearance to Inside Corner

5-1/2″

A B

3″

60-1/4″

Diagram 45

Diagram 46

85-3/16″

IMPORTANT
Must use Rear Venting Deflector packaged with unit in rear vent horizontal termination applications.

28-1/2″ (724mm)

38 | Regency Bellavista® B41XTCE -11 Gas Fireplace

Diagram 47

installation
Venting Arrangements for Horizontal Terminations
The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90o (two 45o elbows equal one 90o elbow).

· Maintain clearances to combustibles as listed in “Clearances” section · Horizontal vent must be supported every 3 feet. · Firestops are required at each floor level and whenever passing through a wall. · A wall thimble is mandatory for all horizontal terminations due to high temperatures.

Horizontal (Feet)

0

2

4

6

8

10

12

14

16

18

20

18

16
Restrictor 1-1/2″ Open Set 3
14

Vertical Height (Feet)

12

Restrictor 2-1/2″ Open

10

Set 2

8

Restrictor 3-1/2″ Open

Set 1

6

4

47-1/2″

2

(1207mm)

Minimum

Height

Requirement

0

Diagram 48

Regency Bellavista® B41XTCE -11 Gas Fireplace | 39

installation

Unit Installation with Horizontal Termination – 5″ x 8″ Venting (Rigid Vent Systems)
Minimum Vent Clearances
to Combustibles

  • Clearances noted below must be maintained; except when passing through a wall, ceiling or at the termination where the use of a firestop or wall thimble reduces clearance to 1-1/2″ (38 mm).

Horizontal Top*

3″ (76 mm)*

Horizontal Side

2 ” (51 mm)

Horizontal Bottom 2″ (51 mm)

Vertical Vent

2″ (51 mm)

Below are the recommended framing dimensions
(inside measurements) for the 5″ x 8″ rigid vent terminations – for use with a firestop or wall thimble.
Install the vent system according to the manufacturer’s instructions included with the components.

1. Set the unit in its desired location. Check to
determine if wall studs or roof rafters are in
the way when the venting system is attached.
If this is the case, you may want to adjust the location of the unit. Rough in the gas preferably
on the right side of the unit and the electrical
(junction block is on the left side) on the left. 2. Direct Vent pipe and fittings are designed with
special twist-lock connections to connect the
venting system to the appliance flue outlet. A twist-lock appliance adaptor is required.
3. In conjunction with the Approved Vent system, install the adaptor after the unit is set in its de-
sired location. Slip the adapter over the existing inner and outer flue collar. Fasten to the outer collar only with the 3 supplied screws (drilling pilot holes will make this easier). 4. Level the fireplace and fasten it to the framing using nails or screws through the top and side
nailing strips.

Horizontal runs of vent must be supported every 3 feet (0.9 metres). Wall straps are available for this purpose. 6. Mark the wall for a square hole.-see chart to left
for size. The center of the square hole should line up with the centreline of the horizontal pipe. Cut and frame the square hole in the exterior wall where the vent will be terminated. See diagram 54 for centerline requirements. If the wall being penetrated is constructed of non-combustible material, i.e. masonry block or concrete, an 8″ (203 mm) diameter hole is acceptable.
Notes: a) The horizontal run of vent must be level, or have a 1/4 inch rise for every 1 foot of run towards the termination. Never allow the vent to run downward. This could cause high temperatures and may present the possibility of a fire. b) The location of the horizontal vent termination on an exterior wall must meet all local and national building codes, and must not be blocked or obstructed. See “Exterior Vent Termination Locations” section for more details.
center of hole
CL
CL
Diagram 50
IMPORTANT
Must use Rear Venting Deflector packaged with unit in rear vent horizontal termination
applications.
c) Snorkel Terminations: For installations requiring a vertical rise on the exterior of the building, 14-inch and 36-inch tall Snorkel Terminations are available, as well as the standard Riser Vent. Follow the same installation procedures as used for standard Horizontal Termination. NEVER install the snorkel upside down.

Rear Vent 28-1/2″ (724mm)
47-1/2″ (1207mm) Min. height (5″ x 8″)

Diagram 49

5. Assemble the desired combination of pipe and elbows to the appliance adaptor and twist lock
for a solid connection.

Snorkel

Note: For best results and optimum performance with each approved venting system, it is highly

Min. 12″* (305mm)

recommended to apply “Mill-

Pac” sealant (supplied) to every

inner pipe connection. Failure to do so may result in drafting or performance issues not covered under warranty.

Diagram 51
*As specified in CSA B149.1 Installation Code. Local codes or regulations may require different clearances.

40 | Regency Bellavista® B41XTCE -11 Gas Fireplace

Below Grade Snorkel Installation If the snorkel termination must be installed below grade, i.e. basement application, proper drainage must be provided to prevent water from entering the snorkel termination. See diagram 56. Do not attempt to enclose the snorkel within the wall or any other type of enclosure.
Snorkel
Min. 12″ (305 mm)
Window Well
Adequate Drainage Gravel
Diagram 56 7. Ensure that the pipe clearances to combustible
materials are maintained (Diagram 55). Install the termination cap. Note: If installing termination on a
vinyl siding covered wall, a vinyl siding standoff or furring strips must be used to ensure that the termination is not recessed into the siding.
The four wood screws provided should be replaced with appropriate fasteners for stucco, brick, concrete, or other types of sidings.
8. Before connecting the horizontal run of vent pipe to the vent termination, slide the Wall Thimble over the vent pipe. The wall thimble is required for all horizontal terminations.
9. Slide the appliance and vent assembly towards the wall carefully inserting the vent pipe into the vent cap assembly. It is important that the vent pipe extends into the vent cap sufficient distance so as to result in a minimum pipe overlap of 1-1/4 inches (32 mm). Secure the connection between the vent pipe and the vent cap.
10. Install wall thimble in the center of the framed hole and attach with wood screws.

installation

Unit Installation with Horizontal Termination 5″ x 8″ Venting (Flex Vent Systems)
Minimum Vent Clearances
to Combustibles

  • Clearances noted below must be maintained; except when passing through a wall, ceiling or at the termination where the use of a firestop or wall thimble reduces clearance to 1-1/2″ (38 mm).

Horizontal Top Horizontal Side Horizontal Bottom Vertical Vent

3″ (76 mm) 2 ” (51 mm) 2″ (51 mm) 2″ (51 mm)

Below are the recommended framing dimensions
(inside measurements) for the 5″ x 8″ rigid vent terminations – for use with a firestop or wall thimble.

Recommended Framed Opening Size

Vent Size

Framing Size

5″ x 8″

11″ x 11″

1. Locate the unit in the framing, rough in the gas (preferably on the right side of the unit). Locate the centerline of the termination and
mark wall accordingly. Cut a square hole in the
wall – see chart (inside dimension).
Note: When installing a appliance where the exterior of the house will be or is sided with vinyl siding, a vinyl siding standoff or furring strips must be used to ensure that the termination cap is not recessed into the siding. If there is no siding installed – install the vinyl siding standoff or furring strips to the exterior of the home where the termination cap is to be installed. Install the cap on the vinyl siding standoff or furring strips. J-channel can then be installed around the vinyl siding standoff, then the siding can be installed. If vinyl siding is already installed – line up the vinyl siding standoff or furring strips on the vinyl siding where the termination cap is to be installed, trace out the vinyl siding standoff or furring strips, then cut out and remove the vinyl. Install the standoff to the exterior of the home. Install the termination cap on the vinyl siding standoff or furring strips.

2. Level the fireplace and fasten it to the framing using nails or screws through the nailing strips.
3. Assemble the vent assembly by applying MillPac to the inner flue collar of the termination and slipping the inner flex liner over it at least 1-3/8″ (35 mm). Fasten with the 3 screws (drilling pilot holes will make this easier). Apply Mill-Pac to the outer flex pipe and slip it over the outer flue collar of the vent terminal at least 1-3/8″(35 mm) and fasten with the 3 screws.
NOTE: Horizontal sections must be supported at intervals not exceeding 3 feet (0.9 metres). (Flame picture and performance will be affected by sags in the liner).
4. Separate the 2 halves of the wall thimble and securely fasten the one with the tabs to the outside wall making sure that the tabs are on top and bottom. Fasten the other thimble half to the inside wall. The thimble halves slip inside each other and can be adjusted for 2 x 4 or 2 x 6 walls.
5. Slip the assembled liner and termination assembly through the thimble making sure the termination cap faces up (there are markings on the cap that show which way is up). This will position the termination cap with proper down slope for draining water. Fasten the cap to the outer wall with the 4 supplied screws.
6. Pull the centre inner and outer flex liner out enough to slip over the flue collars of the fireplace. (You may wish to cut the liner shorter to make it more workable.) Do not bend liner more than 90º. The liners must slip over the collars a minimum of 1-3/8″.
7. Apply Mill-Pac over the fireplace inner flue collar and slip the inner flex liner down over it and attach with 3 supplied screws.
8. Do the same with the outer flue collar and outer flex liner.
9. Apply a bead of silicone between the thimble and termination and around the outer edge of the terminal at the wall in order to keep the water out.
IMPORTANT: Do not locate termination hood where excessive snow or ice buildup may occur. Be sure to check vent termination area after snow falls, and clear to prevent accidental blockage of venting system. When using snow blowers, make sure snow is not directed towards vent termination area.

ASTROCAP XL DIMENSIONS (946-623/P)

11″ (279mm)
Diagram 52
CL

11″ (279mm)
center of hole
CL

Rear Vent 28-1/2″ (724mm)
47-1/2″ (1207mm) Min. height (5″ x 8″)

Diagram 58
IMPORTANT Must use Rear Venting Deflector packaged with unit in rear vent horizontal termination applications.

5″ dia. flue pipe with spring spacer

2″ x 4″ or 2″ x 6″
AstroCap XL Termination Cap

Outside Wall
Furring Strips

Diagram 57

8″ dia. air intake

Screws Vinyl Siding

Screws

Wall Thimble

Regency Bellavista® B41XTCE -11 Gas Fireplace | 41

installation

Venting Arrangements for Vertical Terminations
The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations, using two 90o elbows, with rigid/ flex pipe venting systems for propane and natural gas. Two 45o elbows equal to one 90o elbow. Maximum of four 45o elbows allowed.

Horizontal (Feet)

2

4

6

8

10

12

0

Vertical Height (Feet)

40

38

36

34

32

30

28

26

Restrictor 1-1/2″ Open

24

Set 3

22

20

Restrictor 2-1/2″ Open

18

Set 2

16

14

12

10

Restrictor 3-1/2″ Open

Set 1

8

Maximum 10′ Centerline to Centerline 6

4

Min. 47-1/2″ (1.2m) Minimum 8′ (2.4m)

2

0 Maximum 8′ Centerline to Centerline

Diagram 53

· Vent must be supported at offsets. · Firestops are required at each floor level and whenever passing through a wall. · Maintain clearances to combustibles as listed in the “Clearances” section. · Refer to the “Vent Restrictor Position” section for details on how to change the vent restrictor from the factory setting to 3-1/2″
opening, 2-1/2″opening and to 1-1/2″ opening.
Note: Must use optional flue adapter when using Rigid Pipe (Part # 770-994).
42 | Regency Bellavista® B41XTCE -11 Gas Fireplace

Vertical Terminations – Three 90o Elbows (Rigid/Flex Pipe 5″ x 8″)

One 90o elbow = Two 45o elbows.

Option V
A) 0′ Min. B) 1′ Min. C) 2′ Min. D) 3′ Min. E) 4′ Min. F) 5′ Min.

V + V1
2′ Min. 3′ Min. 4′ Min. 6′ Min. 7′ Min. 8′ Min.

H + H1 2′ Max. 2′ Max. 3′ Max. 4′ Max. 5′ Max. 6′ Max.

With these options, maximum total pipe length is 30 feet with minimum of 6 feet total vertical and maximum 8 feet total horizontal.
Please note mini-
mum 1 foot between 90o
elbows is required.

G) 6′ Min. 9′ Min. 7′ Max.

H)

7′ Min 10′ Min. 8′ Max.

Restrictor: 2-1/2″ open, Set 2

Lengths do not include elbow indicated.

Must use rigid pipe adaptor #770-994

V1 H1

H

V

installation

Diagram 54

Regency Bellavista® B41XTCE -11 Gas Fireplace | 43

installation

Unit Installation with Vertical Termination – 5″ x 8″ Venting (Rigid Vent Systems)
Must use rigid pipe adaptor #770-994

  • Clearances noted below must be maintained; except when passing through a wall, ceiling or at the termination where the use of a firestop or wall thimble reduces clearance to 1-1/2″ (38 mm).

1. Maintain the 2″ clearances
(airspaces) to combustibles when passing through ceil-
ings, walls, roofs, enclosures, attic rafter, or other nearby combustible surfaces. Do not
pack airspaces with insulation.
Check “Venting” Sections for
the maximum vertical rise of the venting system and the
maximum horizontal offset limitations.

2. Set the gas appliance
in its desired location.
Drop a plumb bob down
from the ceiling to the
position of the appliance Diagram 55 flue exit, and mark the location where the vent
will penetrate the ceiling. Drill a small hole
at this point. Next, drop a plumb bob from the roof to the hole previously drilled in the
ceiling, and mark the spot where the vent will penetrate the roof.

3. A Firestop spacer must be installed in the floor or ceiling of every level. To install the Firestop spacer in a flat ceiling or wall, cut a 11-inch square hole. Frame the hole as
shown in Diagram 2 and install the firestop.
Note: All vertical terminations are vented using 5″ x 8″ venting and rigid pipe adaptor #770-994.

11″(279mm) square hole
framing

11″ 11″

firestop spacer

4. Assemble the desired lengths of pipe and elbows. Ensure that all pipes and elbow connections are in the fully twist-locked position and sealed.
Diagram 57 NOTE: For best results and optimum performance with each approved venting system, it is highly recommended to apply “Mill-Pac” sealant (supplied) to every inner pipe connection. Failure to do so may result in drafting or performance issues not covered under warranty.
5. Cut a hole in the roof centered on the small drilled hole placed in the roof in Step 2. The hole should be of sufficient size to meet the minimum requirements for clearance to combustibles of 2″. Slip the flashing under the shingles (shingles should overlap half the flashing) as per Diagram 63.
Diagram 58
The upper half of the flashing is installed under the roofing material and not nailed down until the chimney is installed. This allows for small adjustments.
6. Continue to assemble pipe lengths.
Note: If an offset is necessary in the attic to avoid obstructions, it is important to support the vent pipe every 3 feet, to avoid excessive stress on the elbows, and possible separation. Wall straps are available for this purpose.

Diagram 56

Galvanized pipe is desirable above the roofline due to its higher corrosion resistance. Continue
to add pipe sections through the flashing until the height of the vent cap meets the minimum
height requirements specified in Dia. 64 or local codes. Note that for steep roof pitches, the vertical height must be increased. A poor draft, or down drafting can result from high wind conditions near big trees or adjoining roof lines, in these cases, increasing the vent height may solve the problem.

44 | Regency Bellavista® B41XTCE -11 Gas Fireplace

Diagram 58

Roof Pitch
flat to 7/12 over 7/12 to 8/12 over 8/12 to 9/12 over 9/12 to 10/12 over 10/12 to 11/12 over 11/12 to 12/12 over 12/12 to 14/12 over 14/12 to 16/12 over 16/12 to 18/12 over 18/12 to 20/12 over 20/12 to 21/12

Minimum Vent Height

Feet Meters

2

0.61

2

0.61

2

0.61

2.5 0.76

3.25 0.99

4

1.22

5

1.52

6

1.83

7

2.13

7.5 2.29

8

2.44

7. Ensure vent is vertical and secure the base of the flashing to the roof with roofing rails, slide storm collar over the pipe section and seal with a mastic.
8. Install the vertical termination cap by twistlocking it.

Note: Any closets or storage spaces, which the vent passes through must be enclosed.
Gas Line Installation

The gas line is brought through the right side of the appliance. The gas valve is situated on the right-hand side of the unit and the gas inlet is on the right-hand side of the valve.
The gas line connection may be made of rigid pipe, copper pipe or an approved flex connector. (If you are using rigid pipe, ensure that the valve can be removed for servicing.) Since some municipalities have additional local codes, it is always best to consult with your local authorities and the CSA B149.1 installation code.
For U.S.A. installations follow local codes and/or the current National Fuel Gas Code, ANSI Z223.1.
When using copper or flex connectors use only approved fittings. Always provide a union so that gas lines can be easily disconnected for servicing. Flare nuts for copper lines and flex connectors are usually considered to meet this requirement.
Important: Always check for gas leaks with a soap and water solution or gas leak detector. Do not use open flame for leak testing.

Termination Cap

Vertical Terminations – Vertical Flex Vent Kit (Part #946-772)

Storm Collar Flashing

installation

Vertical Flex Vent Kit includes:
· 20 ft. flex pipe (inner & outer) with 10 spacers
· 3 wall straps
· Ceiling firestop · Firestop spacer · Brackets · Flex to rigid adaptor

· Roof support
· 36″ rigid DuraVent pipe · Storm collar · High wind termination cap · Hardware

The roof flashing is not included with this kit and must be purchased separately.

Roof supporFt irestop spacer to prevent debris from falling into the ceiling firestop
Ceiling firestop Enclosure

NOTE

Vertical flex installations must conform to the limitations set in the vertical venting charts.

You must choose 1 of the following:

Part #

Description

58DVA-F6-0/12-6/12

Roof Flashing

58DVA-F12-7/12-12/12

Roof Flashing

1. Maintain the 1-1/2″ (38 mm) clearance (air space) to combustibles

when passing through ceilings, walls, floors, enclosures, attic rafters or other nearby combustibles. Do not pack air spaces

with insulation. Check venting sections for the maximum vertical

rise of the venting system and the maximum horizontal offset limitations.

Ensure that you maintain clearances around enclosures, walls,
below or above floors, floor joists, etc. Each appliance has different clearance requirements (top,sides,bottom). See specific appliance manual for details.

2. Set the appliance in its desired position. Drop a plumb bob down
from the ceiling/floor joist to the position of the appliance flue exit and mark the location where the vent will penetrate the ceiling. Drill a small hole at this point. Next drop a plumb bob from the roof to the hole previously drilled at the ceiling level and mark the spot where the vent will penetrate the roof.

3. Cut a hole in the roof centered on the small hole placed in the roof in the previous steps. The hole should be a minimum of 11″ (279 mm). The hole may be round and or square.

4. Slip the flashing under the shingles and line up flashing so it is
centered to the hole (shingles should overlap half of the flashing) as per Diagram 1.

Diagram 1 – The upper half of the flashing is installed under the
roofing material and not nailed down until the chimney is installed. This allows for small adjustments.
Diagram 1
5. A ceiling firestop/firestop spacer must be installed when passing through each floor or ceiling level. To install the ceiling firestop/ firestop spacer in a flat ceiling or floor joist cut a 11″ (279 mm) square hole. Frame the hole as show in Diagram 2 and install the
ceiling firestop. Slide the top attic insulation spacer onto the top of the attic insulation shield/firestop – See Diagram 2a. Secure with 4 screws/nails. If more than one is required, these can be purchased separately.
The ceiling firestop/firestop spacer may be cut down to size if this shield is too high for the application.

Diagram 2a

Ceiling firestop

6. Determine the overall height of the chimney from the top of the appliance to the underside of the vent. If required cut the flexible inner and outer pipe to the desired length up to a maximum of 20 ft. (6.1 m).
7. Put a bead of Mill-Pac around the 5″ (127 mm) collar on the appliance and slide the inner flex pipe over the inner collar of the appliance and secure with a minimum of 3 screws.
8. Install 5″ (127 mm) spacers around 5″ (127 mm) flex.
9. Repeat Step 7 to install the outer pipe to the outer collar of the appliance.
If an offset is necessary in the attic or floor joists it is important to support the vent pipe every 3 feet (914 mm )to avoid excessive stress and sagging of the vent pipe. Wall straps are provided (3 in total) for this purpose. All round/plumbers strapping may also be used if further supports are required.
10. Attach the rigid pipe section to the adaptor by using MillPac on the inner/ outer pipe. Use 3 screws to secure outer pipe.
11. Secure inner flex pipe to pipe adaptor using Mill-Pac over the adaptor. Slide the inner pipe over the flex to rigid adaptor and secure with 3 screws.
12. Repeat Step 11 to secure outer flex.

NOTE

NOTE

11″ 79

Ceiling firestop

Diagram 2

Regency Bellavista® B41XTCE -11 Gas Fireplace | 45

installation

(Part #946-772)

13. Slide the finished length up towards the flashing ensuring the

1le3n. gStlihdeotfhepifpineishisedalemnginthimupumtowoafrd2s ftheeetfla(s0h.6in1g emn)sumrinegatshuereledngftrhoomf theptipoepisofatmhienimrouomf. oLfe0v.6eml tmheeacshuirmednferoymatnhde stoepcoufrteheusroinofg. Ltehveelrothoef supcsphidoimertnopef rytohaevnirddoeosdef cawusirteshhuokswiitnntgoutbhsieontgrtooaomfmssiunipdimpeouormtfptorhofev2irdsoecodrefwwaissthsphkeiotr wtsoidnbeuo-tstsoienmeg 1a3. mSDliidnieaigmthreaumfmini3sbohe .fdS2eleensgcDtrhieauwgprsatomwpae4rrdfossrtihdreoeof-lfaspsheiticnehg Deanniasdugrhirneagimgthhet3rlebenq.guSthireeoemf eDnitasg. rSaeme 4 pfoiDpreiairgsoraaommfinp3imiatucfmhoroafs0ne.c6dumrhimnegeiagmshuertethdroefrdqomuifitrh0ee.6mtmoep niosftstihn.esSurofeofiefc.iLeDenviteaalgtnhrdeamadd3itaionfoalr sleencsDchiglDdiueaimetugrnhirrngonaaseftmgvhythesa3aemnrbnater.dreocSeostoerefhrmeeceaouqDsqpdruiuoesahinigirurfoeerseawdni2mndn,tgs,ft4uhtelhsiftisoeieshntrtgirmrisono(aooa0tfmfmyh.sp6eiubinat1pcieiymnphsompuatrbmunrt)uerdpcocrihhoftspeiva2oiiugisdnnsheercstmcddrrueheawwsfqanfiestuishupcirpeaeaikeeldimrtrafnotesottsnierdteblpaesyop.-a.ntStsraSodteermeneeaaeutdmeSdlbiymiet.iprosSsn.oeanel

TermTineartmioninCaatipon Cap

Termination Cap

StormStCoormllarCollar FlashFinlagshing

Storm Collar Flashing

Roof support

SimDleinapggstrhoasmnar3Deaurefroqaruvsireeecdnu,trtihncTigesormmmmineaapttyiohonobCndeaeppifnu0rtc.s6hmalisseistdiinsnseuptfahfircaeietenilnty.saStnredueacSdtidimoitpinosnomanl anual for paDrutranvuemnt bcoemrpso.nents list in the instruction manual for part numbers.

Diagram 3b Roof support
RRooofosufppPoDrittciah gram 3bMinimum Vent Height

Storm Collar TerminFatlaiosnhCinagp

Diagram 3b

Ceiling firestop

Diagram 4

Storm Collar FlashingRoof Support / Brace
Roof Support / Brace
Ceiling Firestop Ceiling Firestop

Roof Pitchflat to 7/12MinimumEncVloesnutreHeight

0.61

over 7/1C2eiltinog f8ire/s1to2p

CeilMinginfireimstopu0m.61Vent

flat to 7/12 oveErnc8los/Ru1re2otoof9P/1i2tch 0.61

Hei0g.6h1t

over 7/12 to 8o/1v2er 9/12 to 10/12 Enc0lo.s6u1re

Fe0e.7t6

over over

8/12 9/12

to to

91o/01v/21e2r

10f/l1a2t

ttoo171//1122

C0e.i6lin1g firestop 0.76

20.99

over over over

10/12 11/12 12/12

ttoooo11vv21ee//o11rr22v11e12/r/C11e722ilin/tgt1oofir2e11st24otp//o11228/1102..2929Ceiling too1v4e/o1r2v1e4r/182/t1o216t/o129/112.52

21.22
1.52
firestop21.83

Minimum Vent Height Meters 0.61
0.61
0.61

Ceiling Firestop
CFeleilixngPFipireestop Flex Pipe

over 14/12 too1v6e/1r216/12 to 18/12 1.83
over 16/12 too1v8eo/1rv21e8r/192/1to22t0o/1120/122.13

2.25.13
2.29

0.76

over 18/12 too2v0oe/v1r2e2r0/1102/t1o221t/o1211/21.229

over 20/12 to 21/12

2.44

3.22.544

0.99

Ptoupt raebveean1dt 4wo.faooctPtoeavvurueeptlfkrrarroienmb11vgee21opanne//dt11nthweo22etfareactttxteaooitnrueg11rlfkirot42oihrnme//bg11ecopt22hwniementenheneetytrheasextyitonseutgertiemotrhr.peb54ipecethwaimnedenfnleaytshhseinyogsutetemr.pipe

1.22
and flashing
1.52

15. Slide stor1m5.cooSlvllaiedr erovs1etr4op/rmi1pe2cloetnlolgatr1ho6uv/ne1tirl2ipt ripeaeclheensgtthhe uflna6stihl iintgr.eaches the flashi1ng.8. 3

Diagram 3
Termination Cap

16. Install ter1m6in.aoIntviosentarclal1pte6br/ym1ti2wniastttoiloon1ck8cina/g1pi2tb. y twist lockin7g it.

2.13

17. Secure th1e7f.laoSsveheicnurgr1teo8tthh/e1e2rfolaotsfohusi2ning0g/ts1oc2rtehwesroof using7.s5crews

2.29

:

bAenyencclolosseetsod.v:oAresnrtyo2rac0gl/oe1sse2ptsatcooers2sw1tho/i1rcah2gtehesvpeanctepsaswseh8sicthhrtohueghvemnutstpasses

2.44
through

must

be enclosed.

Storm Collar Termination Cap Flashing
Storm Collar Roof Support Flashing
Roof Support Ceiling Firestop Enclosure

14. Put a bead of caulking on the exterior between the outer pipe and flashing to prevent water from penetrating the chimney system.
15. Slide storm collar over pipe length until it reaches the flashing.

Support to prevent sagging

Elbow Support

Ceiling Firestop
Ceiling FEinrecsltoospure Flex Pipe

16. Install termination cap by twist locking it.

Support to prevent sagging

Elbow Support

Ceiling Firestop Flex Pipe

17. Secure the flashing to the roof using screws
Note: Any closets or storage spaces which the vent passes through must be enclosed.

Diagram 3a

46 | Regency Bellavista® B41XTCE -11 Gas Fireplace

installation

Vertical Flex Extension Kit (Part # 946-769)
20 foot (6.1 m) flex pipe extension
Vertical Flex Extension Kit includes: · 20 ft. flex pipe (inner & outer) with 10 spacers
· 3 wall straps · Flex adaptor · Hardware
Used in conjunction with the 946-772 Vertical Flex Vent Kit for vertical installations.
1. Stretch out both inner 5″ (127 mm) and outer 8″ (203 mm) pipe up to a maximum of 20 ft. (6.1 m).
The inner and outer pipes may be cut if only a short length is required.

5″ (127 mm) inner pipe – 20 ft. (6.1 m) 10 spring spacers
Flex adaptor 3 wall straps

NOTE

2. Install spring spacers around 5″ (127 mm) inner pipe as shown. Slide outer flex pipe over and all the way down the 5″ (127 mm) pipe.
3. Apply a bead of Mill Pac around the perimeter of the 5″ (127 mm) inner collar of the flex adapter and slip the 5″ (127 mm) inner flex pipe from the Vertical termination kit over the flex adapter ensuring that the inner flex pipe overlaps the collar by at least 1.4″ (35 mm). Fasten with 3 screws.
4. Apply a bead of Mill Pac around the perimeter of the 8″ (203 mm) outer collar of the flue adapter and slip it over the 8″ (203 mm) outer flex pipe from the vertical termination kit ensuring that the outer flex pipe overlaps the collar by at least 1.4″ (35 mm). Fasten with the 3 screws.
5. Repeat steps to secure the other end of the flex adapter using the flex kit.
6. See Vertical Vent installation instructions for installation of the complete vent system.

8″ (203 mm) outer flex pipe 20 ft. (6.10 m)

NOTE

If an offset is necessary in the attic or floor joists it is important to support the vent pipe every 3 ft. (0.91 m) to avoid excessive stress and sagging of the vent pipe. Wall straps are provided (3 in total) for this purpose.
All round/plumbers strapping may also be used if further supports are required.

Regency Bellavista® B41XTCE -11 Gas Fireplace | 47

installation

Ceiling Firestop / Firestop Spacer (Part # 946-770)

Used in conjunction with the 946-772 Vertical Flex Kit and 946-769 Vertical Flex Extension Kit.
A ceiling firestop/firestop spacer must be installed when passing through each floor or ceiling level.

11″ (279 mm) square hole
framing

Steps to install the ceiling firestop/firestop spacer in a flat ceiling or floor joist:

1. Cut a 11″ (279 mm) square hole. 2. Frame the hole as show in Diagram 1. 3. Install the ceiling firestop. 4. Slide the top attic insulation spacer onto the top of the attic insu-
lation shield/firestop – See Diagram 1a. 5. Secure with 4 screws/nails.

Diagram 1

Firestops can be purchased separately if more than one is required.
The ceiling firestop/firestop spacer may be cut down to size if it is too high for the application.

Termination Cap

127 mm inner pipe

Storm Collar

Termination CaFplashing Firestop spacer to prevent debris

127 mm inner pipe10 spSritnorgm Csopllaarcers

from falling into the ceiling

Flashing Roof support firestop

Ceiling firestop

10 spring spacers
Roof support

Ceilfilnegxfiaredsatopptor

Enclosure
flex adaptor

Diagram 1a

Ceiling firestop

NOTE

outer flex pipe

outer flex pipe

Used in conjunction with the 946-755 Vertical flex kit and 946-756 kit Vertical flex extension kit/Horizontal power vent kit.

Used in cAocnejuilinncgtifoirneswtiothp/tfhirees9t4o6p- s7p5a5cVeerrmticuasltfbleexinksittaalnledd9w4h6e-7n5p6aksistiVnegrtthicraolugh each

flex extefnlosoiornorkcite/Hilionrgizleovnetal.lTpooiwnsetravllethnet kciet.iling firestop/firestop spacer in a flat ceiling

or floor joist cut a 279 mm square hole. Frame the hole as show in Diagram

79

Aceiling1firaensdtoipn/sfitraelsl ttohpe scpeailcinegr mfiruessttobpe.inSslitdaellethdewthoepnapttaicssininsgultahtriooungshpeaaccehr onto the floor or cetoilpingofletvheel.aTtoticinsintaslul ltahteiocneislihnigeflidr/efisrteospto/fipre-stSoepespDaiacegrrainma 1flaat. cSeeilcinugre with 4 or floor josicsrtecwust/ana2i7ls9. Imf mmorseqtuhaarneohnoeleis. Freraqmuireetdh,ethheosleecaasnsbheopwuirnchDaisaegdrasmeparately. 79

1 and install the ceiling firestop. Slide the top attic insulation spacer onto the top of the atticTihnesucleaitliionng fsirheisetlodp/f/ifrieresstotopp- sSpaeceeDr miaagyrabme c1uat.dSowecnutroesiwzeithif t4his shield screws/nails. Ifims otoreo thhiagnhofonretihsereaqpupirliecda,titohne.se can be purchased separately.

The ceiling firestop/firestop spacer may be cut down to size if this shield is too high for the application.

TeTremrminiantaiotinonCCapap

SStotromrmCCololallrar TeTremrminiantaiotinonCCaFpaFlaplsahsihnigng Ceiling firestop

Ceiling firestop

SStotromrmCCololallrar
FFlalsahsihnigng RRooofosf uspuppoprotrftirestop

RRooofosf uspuppoprotrftirestop Ceiling firestop

Enclosure Ceiling firestop

Enclosure

Ceiling firestop

Ceiling firestop

48 | Regency Bellavista® B41XTCE -11 Gas Fireplace

Pilot Adjustment
Periodically check the pilot flames. Correct flame pattern has two strong blue flames: 1 flowing around the flame sensor and 1 flowing across the burner (it does not have to be touching the burner).

Burner

Flame Sensor

Pilot

Ignitor

B41XTCE -NG11 System Data

For 0 to 4500 feet altitude Burner Inlet Orifice Sizes: #30

Max. Input Rating 42,500 Btu/h Min. Input Rating 30,000 Btu/h

Supply Pressure min.5.0″ w.c.

Manifold Pressure

(High)

3.5″ w.c.

Manifold Pressure

(Low)

1.6″ w.c.

Note: If you have an incorrect flame pattern, contact your Regency® dealer for further instructions.
Incorrect flame pattern will have small, probably yellow flames, not coming into proper contact with the rear burner or flame sensor.
High Elevation
This unit is approved in Canada for altitude to 4500 ft. (CSA-2.17). For Natural Gas installations above 4500 ft. follow current CSA-B149.1.

B41XTCE – LP11 System Data

For 0 to 4500 feet altitude Burner Inlet Orifice Sizes: #49

Max. Input Rating 3 7, 5 0 0 B t u / h Min. Input Rating 2 9 , 5 0 0 B t u / h

Supply Pressure min.11.0″ w.c.

Manifold Pressure

(High)

10″ w.c.

Manifold Pressure

(Low)

6.4″ w.c.

installation
Gas Pipe Pressure Testing
The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig. (3.45 kPa). Disconnect piping from valve at pressures over 1/2 psig.
The manifold pressure is controlled by a regulator built into the gas control, and should be checked at the pressure test point.
Note: To properly check gas pressure, both inlet and manifold pressures should be checked using the valve pressure ports on the valve.
1. Make sure the valve is in the “OFF” position. 2. Loosen the “IN” and/or “OUT” pressure tap(s),
turning counterclockwise with a 1/8″ wide flat screwdriver. 3. Attach manometer to “IN” and/or “OUT” pressure tap(s) using a 5/16″ ID hose. 4. Light the pilot and turn the valve to “ON” position. 5. The pressure check should be carried out with the unit burning and the setting should be within the limits specified on the safety label. 6. When finished reading manometer, turn off the gas valve, disconnect the hose and tighten the screw (clockwise) with a 1/8″ flat screwdriver. Note: Screw should be snug, but do not over tighten.

885 S.I.T. Valve Description

  1. 6 Stage flame adjustment 2) Pilot adjustment 3) Inlet Pressure Tap 4) Outlet Pressure Tap 5) Pilot Outlet 6) Main Gas Outlet 7) Main Gas Inlet

4

3

2

1

7
5 6

Regency Bellavista® B41XTCE -11 Gas Fireplace | 49

installation

Brick Panel Installation

Must install one of the following: Brick Panels, Stainless Steel or Black Enamel Panels.

Dangerous operating conditions may occur if the panels are not installed or if installed with broken panels. Handle with care. DO NOT FORCE INTO POSITION.

  1. Unwrap the Brick Panels from the protective wrapping. Top Panel

  2. Slide the top brick panel under the left or right side panel (which ever is installed first – right side panel shown here) and back brick panel, use care not to damage panel.

Left Panel

Back Panel

Right Panel

  1. Ensure that the logs are not in the unit.

  2. Prior to installation of the brick panels, remove the top panel bracket currently fitted into the baffle opening on the inside top of the firebox. See diagram below.

  3. Install the remaining side panel (left or right), following the same instructions as step 5.

Top Panel Bracket
4) Install the back brick panel first – use caution when clearing the burner assembly and rear log tray so that the panel does not get damaged.
Note: Ensure that the back panel is centered.

  1. Carefully position and fit the top bracket in place by ensuring the tabs of the bracket fit into the baffle openings as shown in the diagram 1 below. Push downwards to secure the bracket to the top panel.

Back Panel Installed 5) Install either the left or right side brick panel by removing the screw
and brick clip on the upper side of the firebox wall (left side shown). Position the left brick panel in place and secure with the brick panel clip and screw removed from the firebox as shown below.
50 | Regency Bellavista® B41XTCE -11 Gas Fireplace

Optional Black Enamel Panel Installation

installation

Black Enamel Panels · Black Enamel panels must be inspected for scratches and dimples prior to installation. All claims to be recorded at this time. Claims for damage after installation will not receive consideration. · Black Enamel panels will discolor a little during normal operation. This is normal and should not be considered a defect.

  • All hand and finger marks MUST be cleaned off with a soft cloth. Use an ammonia based cleaner (ie. glass cleaner) to remove any
    fingerprints before applying heat to the unit. Failure to do this will result in burn stains on panels which you will be unable to remove. Not protected by product warranty.
    Note: Panels must be installed prior to the installation of the log set and vermiculite.

LEFT

TOP BACK

RIGHT

1. Prior to installation of the reflective panels, remove the top panel bracket currently fitted into the baffle opening on the inside top of the firebox. See diagram below.

2. Install the back stainless panel first – be careful not to scratch the panel on the burner or log tray when installing. Ensure the back panel is centered when installed.

3. Install the right side panel – secure with panel clip and 1 screw. See step 3.

Top Panel Bracket

Back Panel

Right Side Panel

Regency Bellavista® B41XTCE -11 Gas Fireplace | 51

installation

4. Remove 1 screw position right side panel in firebox – position panel clip in place and secure with 1 screw (see inset A). Tighten the screw.
Location of screw

7. Carefully position and fit the top bracket in place by ensuring the tabs of the bracket fit into the baffle openings as shown below. Push downwards to secure the bracket to the top panel.

A
5. Slide top panel under the top of the back and right side panels as shown below.

Top panel bracket shown installed with Stainless Steel Panels

6. Install left side panel – repeat step 4. 52 | Regency Bellavista® B41XTCE -11 Gas Fireplace

installation

Log Set Installation
Installation of Brick or Black Enamel Panels must be completed before installing the log set.

Read the instructions below carefully and refer to the images. If the logs are broken do not use the unit until they are replaced. Broken logs can interfere with pilot operation.

Improper positioning of the logs may create carbon build-up and can alter the unit’s performance which is not covered under warranty.

Log Kit# 506-930 contains the following pieces:

I

F

A B C D E F G H I 902-156 902-179 946-669

Rear Bottom Right Log Rear Top Left Log Right Top Cross Log Front Log Piece Left Top Cross Log Center Right Log Front Bottom Right Log
Front Bottom Left Log Center Left Log Lava Rocks Vermiculite Platinum Embers (supplied w/packaged manual)

B
E H

A C
G
D

  1. Carefully remove the logs from the packaging and unwrap them. The logs are fragile, handle with care – do not force into position.

Diagram 1 3) Place Log A on the rear log support pins with the flat side to the back.

  1. Spread vermiculite along the base of the firebox.

Diagram 2 Vermiculite

A
Diagram 3 – Log A 4) Place Log

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals