Truflo OBS-A Series Pressure Gauge
APPLICABLE STANDARDS
- EN 837-1
- Bourdon tube pressure gauges, dimensions, metrology, requirements and testing.
- EN 837-2
- Selection and installation recommendations for pressure gauges.
- ASME B40.100
- Pressure gauges and gauge attachments
- 2014/68/EC
- Pressure equipment directive.
- Specifications:
- Refer to the Truflo OBS Series datasheet
SAFETY
WARNING!
Before installation be certain the appropriate gauge has been selected
considering operating pressure/full-scale pres-sure/proof pressure, wetted
material requirements, media compatibility, operating temperature, vibration,
pulsation, desired accuracy and any other gauge component related to the
service application (including the potential need for pro-tective attachments
and/or special installation requirements). Failure to do so could result in
equipment damage, gauge failure, and/or personal injury. Only qualified
personnel should be permitted to install and maintain pressure gauges.
INSTALLATION
When installing the gauge connection into the application, use the wrench area (above the threaded portion) to thread in and tighten the gauge. Do not use the gauge case to install the gauge. This could result in loss of accuracy, excessive friction, or mechanical damage to the pressure element or gauge case. The gauge connection must be compatible with the mating connection and must be assembled appropriately. If the mating parts do not seal completely, a sealing material may be considered.
- Always Test the System for Leaks to Ensure All Connections are Properly Sealed
- After installation the vent plug can be cut to relieve internal pressure changes in the gauge case that otherwise would have been induced by environmental changes in pressure and/or temperature. Without being vented this change in internal pressure could adversely affect the accuracy of the gauge. If liquid filled, only open vent plugs when the plug is oriented in the vertical position.
STORAGE
Gauge should remain in original packaging until installation. This will protect from mechanical damage as well as environmental conditions.
MAINTENANCE/REPAIRS
Check regularly to ensure the gauge is in good working order. When removing the gauge from the application make sure there is no pressure in the system and all system media has been isolated from the gauge. If gauge is damaged or out of calibration a new gauge must be installed. These gauges are not to be re-calibrated. Misuse or misapplication of this gauge could result in gauge failure, equipment damage and/or personal injury.