Product Information
The Rinnai Wired Remote Controller is a device designed for operation and control of compatible Rinnai indoor models. It is compatible with the following Rinnai indoor models:
- DRCi DINLR07B1 DINLR09B1 DINLR11B1 DINLR13B1 DINLR15B1 DINLR18B1
- Hi-Wall HINRP20M HINRP26M HINRP35M HINRP50M HINRP60M HINRP70M
- Slim Ducted DINSD26MB DINSD35MB DINSD50MB DINSD70MB
- Cassette CIN20RMB CIN26RMB CIN35RMB CIN50RMB
The Wired Remote Controller can be used in both 1:1 and Multi configurations:
- This configuration contains one outdoor unit and one indoor unit.
- Multi
This configuration contains one outdoor unit and two or more indoor units. The only models that may be installed in a multi configuration are Hi-Wall, Cassette, and Slim Ducted units. DRCi is a 1:1 configuration.
Product Usage Instructions
Safety Precautions
Before using the Wired Remote Controller, please read and follow these
safety precautions:
-
Avoid exposure to water or other liquids to prevent electric shock or fire.
-
Avoid installation in areas with high temperatures, humidity, or flammable gases, as they may lead to abnormal operation,
heating, or fire. -
Keep flammable gases away from the controller to prevent fire hazards.
-
Do not touch the controller with wet hands to avoid electric shock.
-
Ensure proper grounding of the controller to prevent electric leakage or heating that may result in fire.
-
Handle the controller with care and avoid applying excessive force to the terminal.
-
Refer to the wiring diagram in the installation manual for proper connection between the wired controller and the indoor unit.
Please note that these safety precautions are for informational purposes only and should be followed for safe operation of the product.
Note: The complete user manual contains additional sections such as Accessory Installation, Installation Method, Specifications, TFT Display, Controller Buttons, Operation, Wireless Control Connection, User Registration, Network Configuration, How to Use App, Warranty, and Contacts. Please refer to the user manual for detailed instructions on these topics.
MODELS CNTRLDRCIPW CNTRLDRCIPB
Wired Remote Controller Operation and Installation Manual
Congratulations on the purchase of your Rinnai Wired Remote Controller.
This manual describes safety precautions required for the use of the product.
· Read this manual carefully before installing or operating your wired remote
controller. Make sure you understand the information provided before
attempting to use the product.
· Keep this manual where it is readily accessible after reading it through.
· If another user operates the product in the future, be sure to hand over
this manual to the new user.
· All the pictures in this manual are for explanation purpose only. They may
be slightly different from the wired remote controller you purchased and the
actual shape shall prevail.
This Wired Controller is compatible with the following Rinnai indoor models:
DRCi DINLR07B1 DINLR09B1 DINLR11B1 DINLR13B1 DINLR15B1 DINLR18B1
Hi-Wall HINRP20M HINRP26M HINRP35M HINRP50M HINRP60M HINRP70M
Slim Ducted DINSD26MB DINSD35MB DINSD50MB DINSD70MB
Cassette CIN20RMB CIN26RMB CIN35RMB CIN50RMB
This controller contains features and functions that are applicable to certain
models in 1:1 and Multi configurations. In brackets NOTE next to the
associated feature or function the applicable models will be listed. If no
models are listed the feature or function is applicable to all.
1:1 – This configuration contains one outdoor unit and one indoor unit.
Multi – This configuration contains one outdoor unit and two or more indoor
units. The only models that may be installed in a multi configuration are Hi-
Wall, Cassette, and Slim Ducted units, DRCi is a 1:1 configuration.
DRCi R32 Wired Controller OIM
SAFETY PRECAUTIONS
This wired controller must be installed only by an Authorised
Person.
· IMPORTANT Installation by other persons may lead to imperfect installation,
electric shock or fire.
· Adhere to this installation manual. · Improper installation may lead to
electric shock or fire. · Reinstallation must be made by an Authorised Person.
· Do not uninstall the unit randomly. Arbitrarily uninstalling may
lead to abnormal operation, heating or fire of the air condition.
· Do not install the unit in a place vulnerable to leakage or
flammable gases. Once flammable gases are leaked and left
NOTE
around the wire controller, fire may occur.
· Do not operate with wet hands or let water enter the wired
controller. Otherwise, electric shock may occur.
· The wiring should adapt to the wired controller’s current.
Otherwise, electric leakage or heating may occur and result
in fire.
· The specified cables shall be applied in the wiring. No external
force may be applied to the terminal.
· The illustrations used in this manual are for explanatory
purposes only.
Rinnai
6
DRCi R32 Wired Controller OIM
BEFORE INSTALLING THE WIRED CONTROLLER
· This manual provides instructions for installing the wired
CAUTION controller. Please refer to the wiring diagram of this installation
manual for connecting the wired controller with indoor unit.
· The wired controller operates in a low voltage loop circuit.
Strictly DO NOT directly contact the high voltage cable above, such as
115V,220V,380V. DO NOT allow the controller or controller loom to come in
contact with high voltage cables such as 115V and above. Clearances for this
situation shall be 300mm or more.
· The shielded wire of the wired controller must be grounded
firmly.
· After completing the wire controller connection, DO NOT use
Megger tester to check the insulation. That may damage the product.
A maximum of two controllers may be installed on a system and the mix may
contain any of the following three controllers:
NOTE
CNTRLDRCINW / CNTRLDRCIPW / CNTRLDRCIPB
Rinnai
7
DRCi R32 Wired Controller OIM
ACCESSORY INSTALLATION
Select the installation location Don’t install at the place where cover with
heavy oil, vapor or sulfureted gas, otherwise, this product would be deformed
that would lead to system malfunction.
Preparation before installation
1. Please confirm that all the following parts have been supplied.
No. Name
Qty Remarks
1 Wired Controller
1–
2 Operation & Installation Manual 1 —
3 Screws
3 ST 3.9*25 (For mounting on the wall)
4 Wall Plugs
3 For Mounting on the Wall
5 Battery (CR2032)
1–
Rinnai
8
DRCi R32 Wired Controller OIM
INSTALLATION METHOD
Wired Remote Controller Dimensions
Figure 1. Dimensions
Remove the backing plate from the wired controller
· Insert a flat screwdriver into the
slots in the lower part of the wired
Srewdriver locations
controller (2 places). Rotate the
screwdriver (2 places) to remove the
backing plate (Figure 2).
Backing plate
Figure 2. Backing plate removal
Do not pry up and down, you can only rotate the screwdriver.
NOTE
Rinnai
9
DRCi R32 Wired Controller OIM
The PCB is mounted in the upper part of the wired controller. Be careful not
to damage the board with the slot screwdriver.
NOTE
Fasten the back plate of the wired controller
· Fasten the back plate on the wall with the 3 screws (ST3.9*25) and plugs
(Figure 3) provided.
Figure 3.
Fasten the back plate of the wired controller
· Remove plastic knockout from the backing plate (Figure 4). · Create a hole
in the wall to access the wall cavity for routing the loom from FCU
to controller.
Rinnai
Remove knockout
Put on a flat surface. Be careful not to distort NOTE the back plate of the wire controller by over tightening the mounting screws.
Figure 4.
10
DRCi R32 Wired Controller OIM
WARNING KEEP BATTERIES OUT OF REACH OF CHILDREN. Swallowing may lead to
serious injury in as little as 2 hours or death, due to chemical burns
and potential perforation of the oesophagus. If you suspect your child has
swallowed or inserted a button battery immediately call the
24-hour Poisons Information Centre on 13 11 26 for fast, expert advice.
Examine devices and make sure the battery compartment is correctly secured,
e.g.
that the screws or other mechanical fasteners are tight. DO NOT use if
compartment is not secure. Dispose of used button batteries immediately and
safely. Flat batteries can still be dangerous and may be a choking hazard.
Inform others about the risk associated with button batteries and how to keep
their children safe. Remove the batteries if the remote is not going to be use
for prolonged periods. This will help prevent damage from leaking
batteries. If leakage has occurred and corrosion is evident the remote will
need to be replaced. Leaking chemicals are toxic and MUST NOT be touched or
ingested. NEVER mix old and new batteries. DO NOT immerse the remote control
in any liquid, this will damage the remote control, rendering it inoperable
and voiding
its warranty.
Battery Installation (CR2032)
· Slide the battery into the holder as shown with the
positive side facing up (Figure 5).
· Put the battery into the installation site and make sure
the positive side of the battery is in accordance with the positive side of
installation site.
· On the first power up set the time of day. If the system
is exposed to a power outage the battery will maintain the time of day. If the
displayed time is not correct once power is restored replace the battery.
Figure 5.
Rinnai
11
DRCi R32 Wired Controller OIM
Thermostat Connection to Indoor Unit
Loom Knockout
Figure 6. Model A
Indoor Unit PCB
Setting up two Controllers
Up to two controllers may be connected to the HA and HB terminals on the
indoor unit as detailed below. From factory, all controllers are supplied with
SW1 dip switch setting 1′ OFF and dip switch setting
2′ OFF. When
configuring a second controller to the DRCi system, two dip switches on the
rear of the second controller (SW1 location) must change to the ON position as
shown below. Dip switch settings for the primary or master controller must
remain unchanged. Refer to Figure 7.
Controller 1 (Master) SW1
Controller 2 (SUB) SW1
ON 12
ON 12
Figure 7.
If two controllers are installed the secondary `SUB’ controller is not capable of the following functions:
l Setting Time and Date l Weekly Schedule
l Timer On / Off
Rinnai
12
DRCi R32 Wired Controller OIM
Wi-Fi control may be setup on one of the controllers only. There is no polarity between HA and HB (Figure 8).
Maximum 40m
Earth the shield
Maximum 40m
Figure 8.
DO NOT allow water to enter the wired control. Use the trap and putty to seal
the wires. Connecting wires must be fixed reliably NOTE and cannot be pulled.
For some units, one wired controller can support multiple units (maximum of 16
units). For configuration of multiple indoor units loom connection is polarity
sensitive and HA must connect to HA on all indoor units, the same applies to
HB. In group control, there will be no error displayed on the wired controller
(Figure 9).
Rinnai
13
DRCi R32 Wired Controller OIM
Total length 40m maximum
Figure 9.
Indoor Unit Connect the terminals on the wired controller (HA ,HB), and the
terminals of the indoor unit (HA ,HB). There is no polarity between HA and HB
(Figure 10).
Indoor Unit
HA HB
Wired Controller
Rinnai
Figure 10.
14
DRCi R32 Wired Controller OIM
Reattach backing plate of the wired controller To reconnect the fascia to the
backing plate, anchor the top lugs first as shown below then swing the fascia
down and press lightly to engage the bottom tabs, be careful not pinch the
loom during this process (Figure 11).
Figure 11. All the illustrations in this manual are for explanation purposes
only. Your wired controller may be slightly different. The actual NOTE shape
shall prevail.
Rinnai
15
DRCi R32 Wired Controller OIM
4. SPECIFICATIONS
Models
Input Voltage Ambient Temperature Ambient Humidity
CNTRLDRCIPW CNTRLDRCIPB 12V~24V
0~43°C
RH40%~RH90%
Wiring Specifications
Controller loom shall be 2-Core (0.5 mm.sq) shielded cable up to 40m long. Rinnai accessory CNTRLLOOM2W18M is 18m long NOTE and may be used for this purpose.
Rinnai
16
DRCi R32 Wired Controller OIM
5. FEATURES
Feature and Functions of the Wired Controller
· TFT Display. · Malfunction Code Display:
shows the error code which is ideal for service.
· 4-way wire layout design. No
raised section at back-end so more convenient to fit the wires and install the
device.
· Room Temperature Display. · Weekly Timer.
Function:
· · Mode: Choose Auto-Cool-Dry-Heat-Fan Auto Restart
· · Fan speed: Auto/Low/Med/High Speed
Automatic Airflow Test (DRCi)
· Swing (1:1 & Multi Hi-Wall)
· Dual Control
· Timer ON/OFF
· Group Control
· Temp Setting
(1:1 – DRCi / Cassette)
· Weekly Timer
· Child Lock
· Follow Me
· LCD Display
· Turbo
· Clock
· 24-hour System
· 12-hour System
Rinnai
17
DRCi R32 Wired Controller OIM
6. TFT DISPLAY
MODE display Displays the current mode,including:
Function display
Time
Status Bar
08: 1 5 AM
26°C .5 26.5°C
FAN SPEED display Displays selected fan speed: LOW MED HIGH
TURBO
AUTO
Child lock Temperature Mode Warning Function Self clean display
1:1 DRCi / Cassette / Hi-Wall
Navigation Bar Wireless control feature display Room temperature display
Follow me feature display
ECO feature display 1:1 – DRCi / Hi-Wall / Cassette
Filter Cleaning Remind 1:1 & Multi Cassette / Hi-Wall SLEEP feature display
Choose Timer
Set up
Timer settings
Delay off display
Vertical Louver Swing 1:1 & Multi Hi-Wall Horizontal Louver Swing 1:1 &
Multi Hi-Wall
Rinnai
18
DRCi R32 Wired Controller OIM
7. CONTROLLER BUTTONS
1 2
Rinnai
3 4
5
1 Menu 2 Return 3 ON/OFF 4 Enter 5 Left / Right, Up / Down
19
DRCi R32 Wired Controller OIM
8. OPERATION
Introduction to Button Setting Start the remote control
1. Wired controller connected to power. 2. Press the ” ” to start the device.
3. Enter the main page display.
08: 1 5 AM
26°C .5
26.5°C
08: 1 5 AM, Sun, Nov. 1 9
O
Power-on status main page display
Shutdown status main page display
Rinnai
20
DRCi R32 Wired Controller OIM
Standby State
1. Occurs after no button operation for 30 seconds. 2. After entering the
standby state, the controller exits all setting states and
restores the main page display.
08: 1 5 AM, Sun, Nov. 1 9
26°C
26.5°C
.0 66%
Screen Off
1. Occurs after no button operation for 60 seconds (including 30 seconds of
standby).
2. TFT screen off. Press any key to exit the screen-off state. The home page
display interface will be restored.
Rinnai
21
DRCi R32 Wired Controller OIM
8-Degree Heating Function (1:1 – Hi-Wall / DRCi / Cassette [Exc: Multi]) In cold climates this feature assists with maintaining the home or room at 8°C. ON/OFF Press this button to change the on/off state of the wired controller. Up/Down Press the ” ” or ” ” to adjust the parameters, or adjust the cursor selection items up or down in the setting state. Left/Right Press the ” ” or ” ” to select the setting item Left/Right, or enter or return to the previous menu during menu setting. Return Press the ” ” to re turn to the main page display, or return to the previous menu during menu setting. Enter Press the ” ” to confirm the change of the currently selected setting item, or enter the next level menu when the menu is set. Menu Press the ” ” to set the status of the menu.
Rinnai
22
DRCi R32 Wired Controller OIM
Mode Setting 1. In the non-menu setting state, press ” ” or ” ” to select the
mode setting.
08: 1 5 AM Auto Cool Dry Heat
2. Press ” ” or ” ” to select mode, and then press ” ” to change the setting
mode.
3. The most selected modes are Auto, Cool, Dry, Heat, Aux Heater, Aux
Heat+Heat, Fan.
4. When the Auto or Dry mode is selected, the fan speed is fixed, the fan
speed cannot be adjusted, while the set temperature is adjustable.
5. When the Cool or Heat mode is selected, the fan speed and temperature can
be adjusted.
6. When the Fan mode is selected, the temperature display will be greyed out,
and the temperature cannot be adjusted.
7. When the mode is set to Aux Heater mode, the fan speed becomes Auto wind,
which cannot be adjusted. At this time, switch to other modes, and the fan
speed no change.
Rinnai
23
DRCi R32 Wired Controller OIM
8. In Aux Heater mode, sleep, 8-degree heating, turbo, and rotation functions
cannot be turned on.
9. When the mode is set to Aux Heater + Heat mode, the fan speed is auto
wind. At this time, Turbo and Rotation functions cannot be turned on, and the
fan speed cannot be adjusted.
10. Aux Heater mode and Aux Heat+Heat mode can be set only when it is
detected.
Set Temperature Setting
1. Press the button ” ” or ” ” to set the room temperature. Indoor Setting
Temperature Range: 10/16/17/~30°C or 20~28°C (model dependant).
Fan Speed Setting
1. In the non-menu setting state, press ” ” or ” ” to select ” setting
function is unavailable under Auto or Dry mode.
“. Fan speed
08: 1 5 AM High Med Low Auto
2. Press ” ” or ” ” to select the fan speed, and then press ” ” to change the fan speed;
Rinnai
24
DRCi R32 Wired Controller OIM
3. Press ” ” or ” ” to select Customised Fan Speed, and then press ” ” to
enter stepless speed regulation.
Fan Speed
50%
4. In stepless speed regulation Setting state, press ” Fan speed, the setting
range is 1%~100%.
5. Press ” ” to exit stepless speed regulation.
” or ”
” to adjust the
Fan Direction Setting (1:1 & Multi – Hi-Wall / Cassette) 1. In the non-menu
setting state, press ” ” or ” ” to select ” “.
08: 1 5 AM Vertical Louver Swing Horizontal Louver Swing
Rinnai
25
DRCi R32 Wired Controller OIM
2. Press ” ” or ” ” to select the fan direction function, press ” ” to enable or disable the function; whether there is a fan direction function is determined by indoor unit.
08: 1 5 AM
26.5°C 58%
26.5°C
66 %
3. When Horizontal Louver Swing is selected, press ” Horizontal Swing
function.
4. When Vertical Louver Swing is selected, press ” Vertical Louver Swing
function.
” to enable/disable the ” to enable/disable the
- Swing option is available on Rinnai Cassettes and Hi-Wall split systems.
5. When the Four-Way Swing is selected, press ” “, and use ” ” or ” ” to
select the fan direction menu.
08: 1 5 AM Unit A Unit B
Rinnai
26
DRCi R32 Wired Controller OIM
6. If indoor unit is TWINS model, you need to select the Unit A or Unit B, then set the basic swing function.
Swing 01 Swing 02 Swing 03 Swing 04
Four-Way Swing
7. When Breezeless is selected, press ” ” to enable/disable the Breezeless
function. The Breezeless function can only be set when the setting mode is set
to Cool. Turn on the Breezeless function to cancel the Turbo, ECO, GEAR,
Horizontal Louver Swing, Wind On, Wind Away Anti-Wind Blowing.
8. When Wind On is selected, press ” ” to enable/disable the Wind On
function. The Wind On function can be set only when Auto, Cool, Heat.
9. When Wind Away is selected, press ” ” to enable/disable the Wind Away
function. The Wind Away function can only be set when Auto, Cool, and Heat.
10. When Anti-Wind Blowing is selected, press ” ” to enable/disable the
AntiWind Blowing function. The function can only be set when the setting mode
is set to Cool, Dry and Fan.
Special Function Settings Turbo
1. Press ” “, use ” ” or ” ” to select ” “, press ” ” or ” “, then turn on
Turbo.
2. The Turbo wind speed icon on the home page is displayed ” “.
Rinnai
27
DRCi R32 Wired Controller OIM
Follow Me
1. Press ” “, use ” ” or ” ” to select ” “, press ” ” or ” “, then turn on
Follow Me.
2. Turn on Follow Me function, and set the room temperature to Indoor unit.
3. Turn on the Follow Me function to cancel the 8-degree heating function.
ECO
(1:1 – Hi-Wall / DRCi / Cassette [Exc: Multi])
1. Press ” “, use ” ” or ” ” or ” ” to select ” “, press ” ” or ” “, then
turn on ECO.
2. Under COOL mode, turn on the ECO function to cancel breezeless, turbo,
sleep, and gear functions.
3. When the ECO function is switched from off to on, when the set temperature
is less than 24°C, the temperature will change to 24°C.
4. When the ECO function is switched from the off state to the on state, the
fan speed defaults to auto. By changing the fan speed, it does not exit the
ECO function.
Sleep
1. Press ” “, use ” ” or ” ” or ” ” to select ” “, press ” ” or ” “, then
turn on Sleep.
2. Under Auto, Cool, turn on the sleep function to cancel Turbo, ECO and
8-degree heating functions.
3. Turn on the sleep function and the fan speed is fixed as auto.
Rinnai
28
DRCi R32 Wired Controller OIM
Special Function Setting
1. When the home page is displayed, press ”
setting.
Menu
” to enter the special menu
Turbo
Follow Me
ECO
Gear
100%
Fresh Air
Turbo
2. Press ” ” or ” ” to select special function setting ” Settings ” ” , Timing settings ” “, system settings ” ” ” to enter the next menu.
” Smart Control “, Press ” ” or
3. In the menu setting state, if the selected item has a next-level menu, you can press ” ” or ” ” to enter the next-level menu. Press ” ” or ” ” to return to the previous menu;
4. Press ” ” or ” ” to adjust options or parameters;
5. Press ” ” to confirm to enable/disable the function.
6. Whether there have special function is determined by indoor unit.
Child Lock
1. Press ” ” to select special function setting ” “.
2. Press ” ” or ” ” to turn on Child Lock. 3. There will be a second
confirmation prompt when opening the Child Lock,
select Confirm again to open the Child Lock. 4. When the Child Lock is turned
on, the wired controller does not receive the
remote control signal.
Rinnai
29
DRCi R32 Wired Controller OIM
5. When the Child Lock is turned on, you can use the key combination ” ” + ” “. Press and hold for 3 seconds to exit Child Lock. When the Child Lock is not turned on, also use the key combination. Press and hold for 3 seconds to activate the Child Lock.
Menu
C/F Switching
C
The keypad will be locked,press confirm to the
homeOTpAagInes.tTaoll unlock the keypad,press” ” and ” “keys for 3 seconds to turn off
the child lock function.
Cancel
Confirm
Menu C/F Switching
Press the ” ” and ” “keys simultaneously for 3 seconds to turn off the child
lock function
Filter Cleaning Reminder
Press ” ” , use ” ” or ” ” to select ” ” , press ” on Filter Cleaning Remind,
symbol lights up ” “.
” or ” “, then turn
Self-Clean (1:1 – Hi-Wall / DRCi / Cassette / Slim Ducted [Exc: Multi])
This process assists with cleaning the indoor coil and depending on the
appliance it can take up to 90 minutes to complete.
1. Press ” ” , use ” ” or ” ” to select ” ” , press ” ” or ” “, then turn on
Self-Clean.
2. When the self-clean is turned on, cancel the fresh air and daily timer
functions. Auto with Temperature Range
1. Press ” ” , use ” ” or ” ” to select ” ” , press ” ” or ” “, then turn on
Auto with Temp Range.
Rinnai
30
DRCi R32 Wired Controller OIM
2. The temperature difference between the upper and lower limits of the set
temperature is greater than or equal to 5°C.
3. The parameters that can be set when the temperature zone control function
is turned on are: MaxTemperature, MaxTemperature, (Time of Validity). The set
parameters are saved, and it is still valid after power-off and power-on.
Auto with Temp Range
Auto with Temp Range
Max Temperature Max Temperature Term of Validity
30°C 16°C Permanent
Permanent Custom Time
Term of Validity
Permanent
Custom Time Start Time Stop Time
Term of Validity
08:00 20:00
4. The setting of Max Temperature and Min Temperature must satisfy
MinTemperature + 5°C Max Temperature;
5. Time of Validity can be set to Permanent or Custom time.
08: 1 5 AM
30.0°C Max
1 6.0°C Min
26.5°C
Daily Timer
1. The daily timer can be set timer on or timer off. 2. The daily timer is
treated as an absolute time (the clock on the wired
controller), when the daily timer is up, the wired controller is turned on or
off.
Rinnai
31
DRCi R32 Wired Controller OIM
3. The daily timer information will take effect immediately if ” ” or ” ” is
pressed.
4. When the scheduled power-on and power-off time are the same, the system
will automatically add 10 minutes to identify the power-on and power-off time.
Daily Timer Timer On Timer Off
Daily Timer
09:00 – – :- –
Timer On
08 00 AM
Weekly Timer After the weekly timer function is turned on, you can set the
daily timer work status separately.
1. Press ” ” use ” ” or ” “, to select ” “, then open Weekly Timer.
Menu Daily Timer Daily Timer Delay Off
Weekly Timer
On
Weekly Timer
Off
Sun
Mon
Tue
Wed Thu
Fri
Sat
Rinnai
32
DRCi R32 Wired Controller OIM
2. Use ” “, ” “, ” ” or ” ” to select the timer date, and use “ADD” to add the set time, include Timer On, Timer Off, Temp, Mode, Fan Speed.
Weekly Timer
Weekly Timer
Sun Mon Tue Wed Thu
Fri
Sat
Add
Timer On
Timer Off Temp Mode
Weekly Timer
09:00 AM
02:00 PM 26.0°C
Save
Delete
3. After the operation is complete, select “Save”.
Timer On
Timer Off Temp Mode
Weekly Timer
09:00 AM
02:00 PM 26.0°C
Save
Delete
4. After completing the settings, you can quickly copy then use the timer through Copy Timer.
Weekly Timer
Weekly Timer
Sun Mon Tue Wed Thu
Fri
Sat
Copy Timer
09:00 -14:00 09:00 -14:00
66°F 66°F
Mon Tue Wed Thu Fri
Copy Timer
Weekly Timer
Weekly Timer
Sun Mon Tue Wed Thu
Fri
Sat
Copy Timer
09:00 AM -02:00 PM 09:00 AM -02:00 PM
26.0°C 26.0°C
NOTE
Rinnai
The weekly timer function is only valid if it is set for at least one day.
33
DRCi R32 Wired Controller OIM
Delay off 1. Press ” “, use ” ” or ” to select ”
Menu Daily Timer Weekly Timer Delay off
” , and then turn on Delay off.
On Off
2. Press ”
” or ”
” to select the following menu.
Off Now 30 mins Later
1 hour Later 2 hour Later
Delay Off
3. When the Delay off function has been activated, when the user press ” ” again, a reminder of the remaining delay time will pop up, and you can choose to Off Now or Off Later.
Languages
English
Francais
Delay off function is set. It will turn off after 6 9 mins.
DeutschDo you want to turn off now or later?
Italia
Off Later
Off Now
Espana
4. The Delay off setting has a power-down memory function. The user needs to manually exit the Delay off function.
Rinnai
34
DRCi R32 Wired Controller OIM
Remote control reception
This option is applicable to Hi-Wall and Cassette models supplied NOTE with a remote control and are configured to a wired controller.
1. The wired controller has the function of remote control reception. After
receiving the valid code of the remote control, the TFT display status will be
refreshed according to the data such as the switch of the remote control code,
the set temperature, the set mode, the fan speed and the timer switch value.
The information is sent to the indoor unit.
2. The wired controller does not receive the digital display remote control
code.
3. When the Follow Me’ function is enabled on the wired controller,
Follow
Me’ signal is received and processed on the remote control as an invalid
signal. When Follow Me’ function is turned off on the wired controller,
Follow Me’ remote control signal is forwarded to the air conditioner and the
wired controller. Do not process the remote control signal of follow me, and
do not open follow me function.
4. When the child lock function is turned on, the remote control does not
receive remote control signals.
Auto Restore
1. Press ” “, use ” ” or ” ” to select ” “.Press ” ” or ” “, then turn on
Auto Restore.
2. When the function of Auto Restore to original setting is changed from off
to on, the current setting mode, set temperature and set fan speed status are
memorised.
Rinnai
35
DRCi R32 Wired Controller OIM
3. When the user changes the set mode, set temperature and set fan speed to
make them different from the state in memory, start the time counting; when
the timer expires, restore the set mode, set temperature and set fan speed to
the memory. (Only restore the set mode, set temperature, set fan speed, do not
change the switch state). When the switch state changes, the original setting
function will be restored if it is not cancelled.
4. If the user wants to update the memorised fixed mode, set temperature and
set fan speed status, it is necessary to turn off the function and then turn
it on again.
5. When the function of Auto Restore to original setting is enabled, if the
weekly timer function has been turned on, a pop-up window will remind the user
that there is a conflict of functions. It is necessary to confirm that weekly
timer function is turned off. If the user chooses to confirm, the weekly timer
will be turned off and continue to enter the automatic recovery setting
interface, select Cancel Return directly.
6. When the weekly timer function is turned on, if the Auto Restore function
has been turned on, a pop-up window will remind the user of the function
conflict. It is necessary to confirm that the timer recovery original setting
function is turned off. If the user chooses to confirm, the Auto Restore will
be turned off and continue to enter the weekly timer setting interface, select
Cancel Return directly.
Rinnai
36
DRCi R32 Wired Controller OIM
Wi-Fi Configuration Smart Control Settings
1. ” “, use ” ” or ” ” to select ” “.
2. During the smart control setting, if the wired controller is not connected
to the network, Step 1, Step 2, and Step 3 section of the network
configuration guide will be displayed in sequence under user operation. When
`Step 3′ of the following Smart Control process is displayed, the wired
controller will automatically enter the AP network configuration state. If the
network configuration is successful, it will prompt the connection completion.
Smart Control Step 1
Smart Control Download the app & activate product
Smart Control Step 2
Smart Control Download the app & activate product
Step1. Please scan the QR code on the manual to download & install the APP for
smart phone control.
1/ 3
Smart Control Step 3
Smart Control Download the app & activate product
Step3. Add the device and set up the network configuration with your phone.
3-1. Make sure your phone is connected to WI-FI/ Wireless networks . 3-2.
Press the POWER button for 3s on the thermostat
3/3
Step2. Sign up for registration on the app.
2/3
Smart Control Step 4
Smart Control
Done! You can now control the air conditioner though the app.
Rinnai
37
DRCi R32 Wired Controller OIM
3. During smart control setting, if the wired controller is connected to the
Internet,
and the network can be reconfigured; after the user reconfirms, the network
configuration guide will be displayed.
MSumltairtlaCnognutraogl es
EN
PT The product is currently connected to
the Internet, do you need to reconfigure
DE
the network?
IT
Online download
Reconfigure
MSumltairltaCnognutargoel s
EN
PT
The pCroodnufircmt istocurerrceonntfilygcuorenntheectneedtwtoortkhe? Internet, do you need to recongure the
DE
network?
IT
Cancel
Online download
Recongure
Confirm
Buzzer
1. When the buzzer is set to be valid, while the wired controller has a valid
key operation, the buzzer will sound once.
2. When the buzzer is set to be invalid, the buzzer does not sound when there
is a button operation on the wired controller.
Language
1. System language settings can be set to English, French, Italian,
Portuguese or Spanish.
2. A prompt will pop up again during the setting. After the customer
reconfirms, the display of the wire controller will automatically change to
the corresponding language.
Rinnai
38
DRCi R32 Wired Controller OIM
Data & Time Setting
1. The lower section of date & time setting can set 12/24 hour system
switching, wired controller time setting or wired controller date setting.
24-Hour Time Timer Setting Date Setting
Date & Time Setting
09:00 Nov-17-2021
2. The time setting interface of the wired controller is as follows:
Timer On
08 00 AM
3. The date setting interface of the wired controller is as follows:
Date Setting
NOV 10 2021
°C/°F Switching
Press ” ” and ” ” for 3 seconds will alternate the temperature display between
the °C & °F scale.
Rinnai
39
DRCi R32 Wired Controller OIM
9. WIRELESS CONTROL CONNECTION
Safety Precautions
· Read the safety precautions carefully before installing the unit. · Refer to
the following important safety issues that must be observed. · Applicable
system: iOS, Android. (Recommended: iOS 10.3, Android 6.0)
· APP can not support the latest software version of Android and
iOS system.
· NOTE Due to special circumstances that have occurred, we explicitly claim
below: Not all of the Android and iOS systems are compatible with APP. We will
not be responsible for any issues as a result of the incompatibility.
Wireless safety strategy
· Wi-Fi only support – WPA-PSK/WPA2-PSK encryption and non encryption.
WPA-PSK/WPA2-PSK encryption is recommended.
· Smart Phone camera needs to be 5 million pixels or above to
ensure QR scan works sufficiently.
· CAUTION
Due to different network conditions, occasionally a response
time-out occurs. Therefore, it may be necessary to repeat
network configuration.
· Due to different network set-ups, sometimes control process
may return time-out. If this occurs, the display between board
and App may not be the same. This is not an issue.
Rinnai
40
DRCi R32 Wired Controller OIM
Rinnai will not be liable for any issues and problems caused by Internet, Wi-
Fi Router and Smart Devices. Please contact the NOTE original provider for
assistance.
Download and Install APP The APP system is subject to update without prior
notice for product function improvement. The actual network configuration
process may be slightly different from the manual, the actual process shall
prevail. Please check the service website for more information.
The following QR Code is only available for downloading the APP.
CAUTION
Android Phone Users: scan Android QR code or go to Google Play and search
“NetHome Plus” APP and download the app. IOS Users: scan iOS QR code or go to
APP Store and search “NetHome Plus” APP and download the app. .
Rinnai
Android
iOS
41
DRCi R32 Wired Controller OIM
10. USER REGISTRATION · Please ensure your mobile device is connected to the
Wi-Fi router. Make sure
the Wi-Fi router is connected to the internet before completing user
registration and network configuration.
· It’s better to log in your email box and activate your registration account
by
clicking link in case you forget the password. You can log in with the third
party account details.
0
Android
iOS
1. If you do not have an account Click “Select
Account”.
2. Enter your email address and password, then click “Register”.
Rinnai
42
DRCi R32 Wired Controller OIM
· Make sure your devices are powered on. · Keep your mobile phone close enough
to your device when
NOTE
you are connecting network to your device.
· Connect your mobile phone to the wireless network at home,
and make sure you know the password of the Wireless Network.
· Check if your router supports 2.4 GHz Wireless Network band
and turn it on. If you are not sure whether the router supports
2.4 GHz band, please contact the router manufacturer.
· The device cannot connect to the Wireless Network that
requires authentication, and it usually appears in public area
such as hotels, restaurants, etc. Please connect to a Wi-Fi that
does not require authentication.
· It is recommended to use a Wireless Network name that only
contains letters and numbers. If your Wireless Network name
contains special characters, please modify it in the router.
· Turn off the WLAN+ (Android) or WLAN Assistant (iOS)
function of your mobile phone when connecting network to
your devices.
· If your device was previously connected to the Wireless
Network and needs to reconnect, please click “+” on app Home page, then add
your device again by the device category and
model according to the instructions on app.
Rinnai
43
DRCi R32 Wired Controller OIM
11. NETWORK CONFIGURATION
· You must select your Wi-Fi network for successful registration.
Turn off your `mobile data’. Ignore any other network and CAUTION make sure
the Android or iOS device is only connected to the
Wireless network you want to configure.
· Make sure the Android or iOS device connected to your Wi-Fi
is functioning well and can connect back to your original Wi-Fi
network automatically.
How to enter AP distribution network
Press ” “, use ” ” or ” ” to select the Smart Control ” network. AP mode is
activated if the icon is flashing.
“, to connect to the
Using Android or iOS device to complete network configuration
· Make sure your mobile device has already been connected to the Wi-Fi network
which you want to use. Ignore other irrelevant Wi-Fi networks as it may
influence
your configuration process.
When your Air Conditioner (AC) enters into AP’ mode, the airconditioning remote controller can’t control it. It is necessary to NOTE finish network configuration or power the AC again in order to control it. Alternatively, you need to wait 8 minutes to let the AC quit
AP’ mode automatically.
There are two ways to complete the network configuration:
· NOTE
Network configuration by Bluetooth scan
· Network configuration by select appliance type
Rinnai
44
DRCi R32 Wired Controller OIM
Network configuration by Bluetooth scan
Make sure the bluetooth function of your mobile device is switched on and
working.
NOTE
1. Open the APP and Press “+ Add Device”.
2. Press “Scan for nearby devices”.
Rinnai
45
DRCi R32 Wired Controller OIM
3. Wait for smart device to complete search, then click to Add Device.
4. Select home Wi-Fi, enter your own Wi-Fi router password and click OK.
Rinnai
46
DRCi R32 Wired Controller OIM
5. Wait for connection to the network.
6. Configuration Success, you can now modify the default name.
Rinnai
47
DRCi R32 Wired Controller OIM
7. You can choose an existing name or customise a new name.
8. Bluetooth network configuration is successful, now you can see
the device in the list.
Rinnai
48
DRCi R32 Wired Controller OIM
Network configuration by selecting appliance type
1. If the bluetooth network configuration has failed, please select the appliance type.
2. Please follow the above steps to enter “AP” mode.
Rinnai
49
DRCi R32 Wired Controller OIM
9:41 Choose Method
Scan QR code on the unit Note: Wait 5-10 seconds while your device is in AP
mode before scanning the QR code.
Manual Setup
3. If choosing the network configuration method.
4. If choosing the “Scan the QR code” method.
Steps 3 and 4 are applicable to Android system only. iOS system does not need
these two steps.
NOTE
Rinnai
50
DRCi R32 Wired Controller OIM
5. If choosing the “Manual Setup” method (Android). Connect to the wireless network (iOS).
6. Please enter password.
Rinnai
51
DRCi R32 Wired Controller OIM
7. Network configuration is successful. The App is now fully configured for use.
8. Configuration Success, you can see the device on the list. You can now operate your system from anywhere with an internet connection.
Rinnai
52
DRCi R32 Wired Controller OIM
When finishing network configuration, APP will display “success” NOTE on the
screen.
Due to changes in the internet settings, the device status may still display
“offline”. If this occurs, refresh the device list on the APP and make sure
the device status shows “online”. Alternatively, user can turn off the AC
power and turn it back on again. The device status will become “online” after
few minutes.
Rinnai
53
DRCi R32 Wired Controller OIM
12. HOW TO USE APP
· Please ensure your mobile device is connected to the Wi-Fi router. Make sure
the Wi-Fi router is connected to the internet before using the App to control
the air conditioner via internet. Please follow the next steps.
1. Type your account and password 2. Select your appliance. and sign in.
Rinnai
54
DRCi R32 Wired Controller OIM
3. Touch to turn on. The user can control the AC on/off status, operation
mode, fan speed, temperature, etc.
Depending on your specific air conditioning system, some NOTE functions may
not be controllable.
Rinnai
55
DRCi R32 Wired Controller OIM
Special Functions
Schedule
User can schedule daily to turn air conditioner ON/OFF at any specific time of
day during the week. User also can choose circulation to keep the AC under
schedule
control every week.
Rinnai
56
DRCi R32 Wired Controller OIM
Sleep
User can customise their own comfortable sleep by setting an overnight target
temperature. To access Sleep, system must already be operating in heating or
cooling mode.
Rinnai
57
DRCi R32 Wired Controller OIM
CAUTIONS Wireless Network module models: US-SK107, EU-SK107:
FCC ID: 2ADQOMDNA21
IC: 12575A-MDNA21
This device complies with Part 15 of the FCC Rules and it contains licence-
exempt transmitter(s)/receiver(s) that comply with Innovation, Science and
Economic Development Canada’s licence-exempt RSS(s).
Operation is subject to the following two conditions:
(1) This device may not cause interference; and
(2) This device must accept any interference, including interference that may
cause undesired operation of the device.
Only operate the device in accordance with the instructions supplied.
Changes or modifications to this unit not expressly approved by the party
responsible for compliance could void the user’s authority to operate the
equipment.
This device complies with FCC radiation exposure limits set forth for an
uncontrolled environment. In order to avoid the possibility of exceeding the
FCC radio frequency exposure limits, human proximity to the antenna shall not
be less than 20cm (8 inches) during normal operation.
Rinnai
58
DRCi R32 Wired Controller OIM
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC NOTE Rules.
These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the
following measures:
· Reorient or relocate the receiving antenna. · Increase the separation
between the equipment and receiver. · Connect the equipment into an outlet on
a circuit different from
that to which the receiver is connected.
· Consult the dealer or an experienced radio/TV technician for
help.
Rinnai
59
DRCi R32 Wired Controller OIM
13. WARRANTY
TERMS OF WARRANTY AUSTRALIA
Rinnai Australia Pty. Ltd. ABN 74 005 138 769, 100 Atlantic Drive, Keysborough
VIC 3173.
NOTICE TO CONSUMERS UNDER AUSTRALIAN CONSUMER LAW
Our goods and services come with guarantees that cannot be excluded under the
Australian Consumer Law.
For a major failure with a good, you are entitled to a replacement or refund
and compensation for any other reasonable foreseeable loss or damage. If the
failure does not amount to a major failure and if the goods fail to be of
acceptable quality, you are also entitled to have the goods repaired or
replaced.
For a major failure with the service, you are entitled to cancel your service
contract with us and obtain a refund for the unused portion, or to
compensation for its reduced value. You are also entitled to be compensated
for any other reasonably foreseeable loss or damage. If the failure does not
amount to a major failure you are entitled to have problems with the service
rectified in a reasonable time and, if this is not done, to cancel your
contract and obtain a refund for the unused portion of the contract.
The benefits provided by this Warranty are in addition to any other rights and
remedies available to a consumer under the Australian Consumer Law and any
other law which may apply to the goods and or services.
Rinnai
60
DRCi R32 Wired Controller OIM
WARRANTY: DRCi R32 Wired Controller
This product is warranted for a period of one (1) year from the date of
purchase, in accordance with the Terms and Conditions of Warranty detailed
below.
IMPORTANT TO BE READ IN CONJUNCTION WITH THE TERMS AND CONDITIONS OF
WARRANTY
· The fitness for purpose of the Rinnai DRCi R32 Wired Controller and ensuring
suitable Wi-Fi connectivity is the sole responsibility of the Qualified
Installer and or Purchaser.
· The DRCi R32 Wired Controller must be installed by a suitably Qualified
Installer
in accordance with local and national wiring codes, otherwise the warranty
will be void.
· Always refer to the Installation and Owner’s Manuals to ensure the correct
installation and operation procedures have been followed.
· The DRCi R32 Wired Controller is to be installed indoors only; warranty
excludes damage caused by the elements such as rain, wind, lightning, or
harmful environmental conditions.
· For full Terms and Conditions, go to the Rinnai website, www.rinnai.com.au
Rinnai
61
DRCi R32 Wired Controller OIM
NOTES
Rinnai
62
DRCi R32 Wired Controller OIM
NOTES
Rinnai
63
DRCi R32 Wired Controller OIM
CONTACTS
innai Australia Pty Ltd
ABN 74 005 138 769 | AU45204
100 Atlantic Drive, Keysborough, Victoria 3173 P.O. Box 460, Braeside,
Victoria 3195 Tel: (03) 9271 6625 Fax: (03) 9271 6622
National Help Line Tel: 1300 555 545 Fax: 1300 555 655 Monday to Friday, 8.00
am to 5.00 pm EST.
Cost of a local call may be higher from a mobile phone. (National calls from public phones in Australia are free.)
For further information visit www.rinnai.com.au or email enquiry@rinnai.com.au
innai has a Service and Spare Parts network with personnel who are fully
trained and equipped to give the best service on your innai appliance. If your
appliance requires service, please call our National Help Line.
With our policy of continuous improvement, we reserve the right to change, or
discontinue at any time, specifications or designs without notice.
B065557
DRCi R32 Wired Controller 120P OIM Issue 2 May 2023
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>