Diablo DSP-10-LV Loop Detector User Guide
- June 13, 2024
- Diablo
Table of Contents
Diablo DSP-10-LV Loop Detector
WIRING
The pin assignments for the detector and the optional wiring harness are:
Pin | Wire Color | Function |
---|---|---|
1 | Black | DC + or AC Line |
2 | White | DC – or AC Neutral |
3 | Orange | Relay B N.O. |
4 | Green | Chassis Ground |
5 | Yellow | Relay A Common |
6 | Blue | Relay A N.O. |
Pin | Wire Color | Function |
--- | --- | --- |
7 | Gray | Loop |
8 | Brown | Loop |
9 | Red | Relay B Common |
10 | Pink or White/Black | Relay A N.C. |
11 | Violet or White/Red | Relay B N.C. |
DIP SWITCHES
1 | Function |
---|---|
OFF | Detect Immediately on Entry |
ON | 2 Second Detect Delay on Entry |
2 | 3 |
--- | --- |
OFF | OFF |
ON | OFF |
OFF | ON |
ON | ON |
4 | Function |
--- | --- |
OFF | Normal Sensitivity |
ON | Sensitivity Boost During Detect |
5 | 6 |
--- | --- |
OFF | OFF |
ON | OFF |
OFF | ON |
ON | ON |
5 | 6 |
--- | --- |
OFF | OFF |
ON | OFF |
OFF | ON |
ON | ON |
8 | Function |
--- | --- |
OFF | Inductive Loop |
ON | Free Exit Probe (Magnetometer) |
9 | 10 |
--- | --- |
OFF | OFF |
ON | OFF |
OFF | ON |
ON | ON |
SENSITIVITY
The factory default is 5 and should work for most installations.
Setting| 0| 1| 2| 3| 4| 5| 6| 7|
8| 9
---|---|---|---|---|---|---|---|---|---|---
%ΔL/L| 0.48| 0.32| 0.24| 0.16| 0.12| 0.08| 0.06| 0.04| 0.03| 0.02
Response| 70 ms ± 10 ms| 140 ms ± 20 ms
INDICATORS
Green Power LED
Steady on when operating normally. See fault table for a flashing condition.
Fault | Display for Current Fault | Display for Prior Fault |
---|---|---|
Low Voltage | 2 Hz with 50% duty cycle | NONE |
Open Sensor | 1 flash ON every 2 seconds | 1 flash OFF every 2 seconds |
Shorted Sensor | 2 flashes ON every 2 seconds | 2 flashes OFF every 2 seconds |
Large Change | 3 flashes ON every 2 seconds | 3 flashes OFF every 2 seconds |
Red Detect A LED
The LED will turn on when a vehicle is over the loop detection area. If delay
is programmed, the LED will blink slowly during the delay interval. If
extension is programmed, the LED will blink fast during the extension
interval.
FAIL-SAFE or FAIL-SECURE
There are three jumpers internal to the detector that are used to select Fail- Safe or Fail-Secure modeof operation for the Relay A output. This setting determines what states the relay output should be in if a loop failure is detected. Fail-Safe operation has the relay activated. Fail-Secure has the relay deactivated. Most applications that are not high security will use the Fail-Safe mode of operation. The detector is shipped in the Fail-Safe mode from the factory. Additional information is available at the Diablo Controls website www.diablocontrols.com or contact technical support at 866-395-6677.