Dimplex VVT75 Landscape Electric Fire Instruction Manual
- June 13, 2024
- Dimplex
Table of Contents
- Important Safety Advice
- General Information
- Technical Information
- Installation Instructions
- Step 1: Choosing Installation Type
- Step 2: Installing the Product
- Step 3: Fuelbed Assembly
- Operation and Use
- Maintenance
- Additional Information
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
**Dimplex VVT75 Landscape Electric Fire Instruction Manual
**
CAUTION: Please read this information guide carefully to be able to safely install, use and maintain your product
Important Safety Advice
When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electrical shock and injury to persons, including the following:
If the appliance is damaged, check with the supplier before installation and operation.
- Do not use outdoors.
- Do not use in the immediate surroundings of a bath, shower or swimming pool.
- Do not locate the appliance immediately below a fixed socket outlet or connection box.
- Do not use this heater if it has been dropped.
- Do not use if there are visibe signs of damage to the heater.
- Use this heater on a horizontal and stable surface.
Children of less than 3 years should be kept away unless continuously supervised.
Children aged from 3 years and less than 8 years shall only switch on/off the appliance provided that it has been placed or installed in its intended normal operating position and they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children aged from 3 years and less than 8 years shall not plug in, regulate and clean the appliance or perform user maintenance.
CAUTION: Some parts of this product can become very hot and cause burns. Particular attention has to be given where children and vulnerable people are present.
Do not use this appliance in series with a thermal control, a program controller, a timer or any other device that switches on the heat automatically, since a risk exists when the heater is accidentally covered or displaced. Ensure that furniture, curtains or other combustible material are positioned no closer than 1 meter from the appliance. In the event of a fault disconnect the appliance. Disconnect the appliance when not required for long periods.
The appliance must be positioned so that the plug is accessible. Electrical Requirements section formore details. Ifthe supply cord is damaged it must be replaced by the manufacturer or service agent or a similarly qualified person in order to avoid a hazard. Keep the supply cord away from the front of the appliance.
Warning : This appliance must be earthed.
The use of an extension lead or multi-plug adaptor is not advised when
connecting this product to the mains. Connection through these devices could
lead to arisk of overloading, overheating and even fire at the extension lead
or adaptor due to inadequate connection quality. This heater must be used on
an alternating current supply (~) only and the voltage marked on the heater
must correspond to the supply voltage.
WARNING: In order to avoid overheating, do not cover the appliance. Do not place material or garments on the appliance, or obstruct the air circulation around the appliance.
The appliance carries a DO NOT COVER warning symbol.
This appliance is equipped with a device to control the room temperature. Do
not use this appliance in small rooms when they are occupied by persons not
capable of leaving the room on their own, unless constant supervision is
provided.
Dimplex Vivente Plus Electric Fire
Models: VVT75, VVT100, VVT150
Thank you for choosing a Dimplex electric fire.
General Information
CAUTION: Ensure installation does not allow fireplace to be in direct contact with building vapour barrier or insulation and meets all local building code.
WARNING: To reduce the risk of fire, do not store or use gasoline or other flammable vapors or liquids in the vicinity of the heater.
-
Select a location that is not susceptible to moisture and is away from drapes, furniture and high traffic.
-
Unpack the fireplace and accessories from the box.
NOTE: Leave the front glass and partially reflective glass, safely, in the box until ready for installation. -
Store the fireplace in a safe, dry and dust free location until it is ready to be installed. This electric fire is designed to be installed into a solid construction — such as an existing chimney breast or plaster board construction. The installation of this product should be carried out by a qualified professional.
There are several options for displaying the fire, including:
- One, Two or Three-sided installation
- Materials to be placed onto the fuel bed
Please follow these instructions to assist you in the installation and operation of this product.
Technical Information
Heat Output | 230V | 240V | |
---|---|---|---|
Nominal Heat Output | PNom | 1.4 | 1.5 |
Minimum Heat Output | Pmin | 1.3 | 1.4 |
Maximum Continuous Heat Output | Pmax | 1.4 | 1.5 |
Auxiliary Electricity Consumption
In Standby Mode| el SB| 0.49| 0.49| W
with electronic room temperature control.
Installation Instructions
Step 1: Choosing Installation Type
-
The Vivente can be configured in 4 different ways:
-
Single-sided – Front glass only (see Fig 1a)
-
Two-sided Right (see Fig 1b)
-
Two-sided Left (see Fig 1c)
-
Three-sided **(see Fig 1d).
**
The Vivente is supplied as a Three-sided configuration. Please follow the steps below to adjust to your desired arrangement.
-
Remove front bottom trim on unit. See Fig. 2
-
On the desired side you wish to cover, remove side glass trim which is held in place by four screws. Attach side panel in place of the side trim using the same four screws See Fig. 3A & 3B
-
For Front Glass Only setup, repeat Step 2 on the opposite side of product.
-
Assemble the appropriate front Trim to the product. (Three different trims are provided with the product to facilitate the various setup options.) See Fig. 2
Step 2: Installing the Product
CAUTION: Two people will be required for various steps of this procedure. This product is designed to be installed into existing block wall or a custom- built studded wall structure. Please consult a competent installer before undertaking this to ensure a safe and secure installation. If installing into an existing chimney or flue, please ensure that the chimney or flue is blocked off. This is to prevent up-draughts affecting product operation.
Electrical Requirements
NOTE: A dedicated, properly fused 13 Amp circuit is required, rated for the appropriate voltage (230-240V). An isolation switch should also be incorporated in cases where the product plug is inaccessible after installation.
WARNING: Construction and wiring must comply with local building codes and other applicable regulations to reduce the risk of fire, electric shock and injury to persons.
WARNING: To reduce the risk of fire, electric shock or injury to persons, always use a licensed electrician.
- Using the product dimensions (Fig. 11) , build a suitable structure for the product to fit into. Ensure that, when installed, the product is within 1m of a power outlet. Please refer to Electrical Requirements section above for more details. It is recommended that the base of the unit is installed between 200mm and 800mm from the floor. This is to maintain an optimised viewing angle of the fire effect. (See Fig. 12) The product must not bear the weight of the finished wall located above it. Consider the use of a lintel for appropriate support.
MODEL | ‘X’ |
---|---|
VVT 75 | 764mm |
VVT 100 | 1014mm |
VVT 150 | 1514mm |
-
Using any combination of the three fixing methods (Fig. 13 a,b,c) , fix the product to its supporting structure.
-
Build the finished wall up against the appliance using the glass trims as a guide. The finished wall should be built in a way that allows the power supply to be accessible after installation.
It is recommended to leave 150mm of clearance area directly above the product for ventilation purposes. (Fig. 12) This clearance area can be located behind the finished wall surface. The product should not be sealed in place with silicone or adhesive as this can restrict airflow.
Step 3: Fuelbed Assembly
A range of fuel bed material has been provided for you to choose your desired look. A set of high-quality ceramic logs enhance the effect of this fire. Please take great care when handling these logs to ensure they do not get dropped or rub against each other, as they are easily marked. The following fuel bed media is included
- Ceramic Logs
- Ash Dust
- Crystal pieces
We have taken great care to create what we feel is the most authentic fuel bed, please follow the steps below for more information. Please note: A mix and match of fuelbed media can also be done to create unique fuel bed assembly.
-
Remove front trim on unit. (Fig. 2)
-
Remove Front Glass from product and store in a safe place. (A suction cup is provided to help remove/place the front glass.) (Fig. 6)
-
For a contemporary setup (Fig.14) , place crystals on fuel bed, covering the top surface of the fuel bed. These will provide a glowing embers effect, when the flame effect is operating.
-
For a traditional look, arrange the logs on top of the fuel bed, to your preference. Please follow the steps at the end of this document which provide a visual representation for log arrangement. Ash dust is also supplied for this setup. Sprinkle this across the fuel bed to produce a realistic log burning effect.
-
Reverse steps 1 and 2 to re-assemble product.
An Authentic Logset can be purchased separately, see Authentic Log table for part numbers.
Authentic Log
Model| Part Number
VVT75| 03/24180/0
VVT100| 03/24181/0
VVT150| 03/24183/0
Operation and Use
WARNING : Failure to follow these operating instructions may result in injury and/or damage. Thank you for choosing the Vivente. We hope you enjoy using your new electric fire. Please take a few minutes to read these instructions. This will help you understand and benefit from all of the following features:
- Onboard controls
- Remote control
- App control
- Heating – including “Comfort$aver”
- Flame effects
- SmartSense
Comfort$aver
This electric fire operates with Comfort$aver technology, which automatically adjusts the fan speed and heater wattage to match the requirements of the room based on the thermostat setting. Conventional electric heaters work by simply being fully on or off, which can result in swings from slightly too warm to slightly too cold.
Comfort$aver operates such that once the room reaches the set point, the fan and heater will continuously run at a low level, to maintain the desired room temperature providing a more comfortable heating which results in up to an 11% energy saving.
If the temperature in the room rises significantly, i.e. sun coming through a window or the central heating turns on, the heater will turn off and periodically turn back on to circulate the air around the unit, until the room temperature drops and requires the heater to be constantly on again.
SmartSense
SmartSense detects activity or movement in a room and automatically switches on the flame effect, without the need for you to touch the controls. SmartSense will also detect inactivity in a room and after a certain period of time switch the product into standby mode. See Fig. 15 which illustrates the detection zone for SmartSense.
When the fire detects no activity, it will switch itself off. You can choose either these periods of time – 30 minutes or 3 hours.
SmartSense is deactivated for 3 minutes after the product is put into standby mode. This allows you to leave the room after putting the product on standby, without triggering the SmartSense function.
SmartSense has the following three settings:
“HOME” (via APP)
On this setting SmartSense will only switch the flame effect when it detects
movement between the hours of 5-11pm, so if you enter the room during the day
the fire will not react. However in the evening, your Dimplex fire will
instantly switch on your flame effect — remembering your last setting.
“24 Hr” (Default)
SmartSense will switch on the flame effect when it detects movement at any
time during the day or night. This is ideal for retail and commercial
environments.
“OFE”
SmartSense can be switched off, which will allow the product to preform
normally in every other aspect
Controls
The unit can be controlled by:
-
Onboard/Manual controls which are located on the upper right of the fireplace (See Fig. 16)
-
Remote control — supplied
-
App control. Using a dedicated App on your smart phone
Not all of the features, however, can be accessed by the on-board controls. To access the full range of features, the smart phone App is required
Operating Instructions (ON BOARD CONTROLS)- See Figure 16
The unit can be operated using the manual controls which are located on the upper right of the fireplace. See Fig. 16
Icon | Function | Description |
---|---|---|
Standby Switch | Turns product on to Standby mode. When pressed to “I”, |
Display Board show “ST.BY” for five seconds, then shows “.” only, to indicate
standby condition.
| Menu Cycle Button| After initial power up, product is on standby. Press Menu
Cycle Button Once : This turns on the flame effect to a default setting.
Display Board show “ON”.
This button cycles through the Product setting options, when the product is operating. These options are “FIRE”, “AMB”, “HEAT”, “Set.T”, “TIMR”, “SNSR” and “VOL”.
“FIRE”: The Flame Brightness Setting can then be adjusted using the “+” or “-” buttons. There are seven settings. (Display shows “-F1-” to “-F5-“, for the different levels of brightness, “-F6-” for Pulsating Effect and “OFF” when the flame effect is turned off.)
“AMB”: The Ambient Setting can then be adjusted using the “+” or “-” buttons. There are seven settings available on the onboard controls. (Display shows “AMB1” to “AMB7”) “AMB8” is a customisable mood setting that is available via the Dimplex Flame Connect App. Please Note: “-F6-” is not an available setting when in “AMB6”, “AMB7” or “AMB8”.
“HEAT”: The set temperature “XXST” is displayed for two seconds, after that, the room temperature “XX°C” for a further two seconds. The Heat Setting can be switched ON/OFF using the “+” or “-” buttons respectively. (Display shows “ON” or “OFF”)
“Set.T”: The Set Temperature can then be adjusted using the “+” or “-” buttons. Temperature range is 15°C – 32°C and is in increments of 1°C (Display shows “15ST” up to “32ST”) After 2 seconds, the current Room Temperature is displayed “XX °C”. This is shown for three seconds
“TIMR”: The Runback Timer can be adjusted using the “+” or “-” buttons. This can be set between 0.5 Hrs and 8.0 Hrs in increments of 0.5 hrs. (“0.5Hr” to “8.0 Hr”)
“SNSR”: The SmartSense Settings can be adjusted using the “+” or “-” buttons. “MIN” turns product off 0.5 hour after last movement detected.”MAX” turns product off 3 hours after last movement detected. “OFF” – Motion Sensor turned off.
“VOL”: The Volume can be adjusted using the “+” or “-” buttons. Volume has seven settings. (“OFF”, which is sound off and “VOL1” to “VOL6”)
+| Increase “+” Button| This button increases the displayed setting when
it is pressed, while in Menu Mode.
–| Decrease “-” Button| This button decreases the displayed setting when
it is pressed, while in Menu Cycle Mode.
User Modes:
Mode Name /Description| Action (Actions cannot be input by remote
control)
---|---
Disable/Enable Heat Options on product| When in heat, press both the Menu
Cycle Button and “-” Button for five seconds. Display reads “CD02”, heat is
now disabled. Repeat to enable Heat.
Switch from Degree Celsius to Degree Fahrenheit.| When in heat, press
both the Menu Cycle Button and “+” Button for five seconds. The product can
then switch from “-°C-” to “-°F-“. Repeat to revert back to degrees Celsius
mode.
**** SmartSense Mode selection.| **** “24Hr” setting operates the
SmartSense at all times. This is the default setting.”HOME” setting; the
product operates the SmartSense between 5pm and 11pm. Please Note: The product
must be connected to the “FLAME CONNECT” App, for the”HOME” setting to
operate.
Remote control
The fireplace is supplied with a remote control.
Operating Instructions using REMOTE CONTROL – See Figure 17
| Icon| Display| Function| Description
---|---|---|---|---
**** A| | “FIRE” / “ST.BY”| Power / Standby| Press Once to
turn the product on. (“ON”)Press a second time to put the product into
standby. (“ST.BY” is shown, then “.” is displayed to indicate standby.)(When
returning from ‘STANDBY’ mode the product will return to previous settings
unless the product has been unplugged, in which case it will reset to factory
settings)
**** B|
| “TIMR”| Timer Cycle| This Button changes the timer setting. This
can be set between 0.5 Hrs and 8.0Hrs in incre- ments of 0.5 hrs. (“0.5Hr” to
“8.0Hr + OFF”) Each Button press will increase timer setting by 0.5hrs.
**** C|
| **** “SNSR”| Smart- Sense Cycle| This Button cycles through the
SmartSense settings. Display will read; “MIN”, “MAX” or “OFF”.”MIN” turns
product off 0.5 hour after last movement detected in room. “MAX” turns product
off 3 hour after last movement detected in room. “OFF” – SmartSense is turned
off
**** D| | “ON”| Heat Mode| First Button press
activates the heat. Display reads “ON – XXST – XX0C”
“OFF”| Heat Mode| Second button press deactivaes the heat.
Display shows “OFF”
E| | “15ST”| Temp Down| Press Once to display current Set
Temperature.Press multiple times to lower the heater temperature in 10C
increments. The lowest temperature that can be set is 150C.
F| | “32ST”| Temp Up| Press Once to display current Set
Temperature.Press multiple times to increase the heater temperature in 10C
increments. The highest temperature that can be set is 320C.
G| | “-F1-“| Flame Brightness Down| Press Once to display current
flame brightness setting.Press to reduce the flame brightness setting. Range
is from “-F1-” to “-F6-” and “OFF”.
**** H|
| “-F6-“| Flame Brightness Up| Press Once to display current flame
brightness setting.Press to increase the flame brightness setting. Range is
“OFF”, then “-F1-” to “-F6-“
I|
| “VOL1”| Volume Down| Press Once to display current volume
setting.Press to reduce the volume setting. Range is “OFF”, then “VOL1” to
“VOL6”.
J| | “VOL6”| Volume Up| Press Once to display current volume
setting.Press to increase the volume setting. Range is “OFF”, then “VOL1” to
“VOL6”.
K| | “AMB1”| Ambient Cycle| Press once to display current
Ambient Setting. Subsequent presses will cycle through the settings. Range is
from “AMB1” to “AMB7”. “AMB8” will also display once it is activated via the
app.
L| | **** “LGT1”| Light Selection Button| Press once to show all top
lights and fuelbed and flame colour lights ON. Subsequent presses cycle
through ON/OFF settings for each of these lights. “LGT1” to “LGT5”
Product Features Overview
Function | Onboard Controls | Remote Control | App Control |
---|---|---|---|
Standby | ✓ | ✓ | ✓ |
Temperature Adjustment (15º C – 32º C) | ✓ | ✓ | ✓ |
Heat Disable | ✓ | – | – |
Heater Mode (ECO, Boost Frost protection, fan, etc.) | – | – | ✓ |
Flame Intensity | ✓ | ✓ | ✓ |
Volume Setting | ✓ | ✓ | ✓ |
Run-back Timer | ✓ | ✓ | ✓ |
7 – Day Timer | – | – | ✓ |
Volume Setting | ✓ | ✓ | ✓ |
Ambient Light Setting | ✓ | ✓ | ✓ |
Ambient Light On/Off | – | ✓ | ✓ |
Customizable Ambient | – | – | ✓ |
SmartSense | ✓ | ✓ | ✓ |
Smart Phone App
“Flame Connect” allows you to control your fire’s function over Bluetooth,
from your hand. Search
for “Flame Connect” on your App Store and install to get started.
https://play.google.com/store/apps/details?id=com.Dimplex.Fires
https://apps.apple.com/us/app/flame-connect/id1516295365#?platform=iphone
Fault Codes
Onboard Display| Description| Action
CD20| Room Sensor (NTC) Error| Contact your retailer and reference this error
code.
CD03| The internal NTC is measuring elevated tempera- tures within the
product.| Unplug Unit at power supply to reset, allow it to cool down, then
plug unit back in to restart.
CD04| Internal Communication Error| Contact your retailer and reference this
error code.
CD05| The internal temperature sensor has failed.| Unplug Unit at power supply
to reset, allow it to cool down, then plug unit back in to restart.
CD53| This error displays when timer settings are out of sync. This occurs
when the product has power cut off for over 40 hours. The product can no
longer operate at the determined time settings, and CD53 is displayed.| Reset
the timer settings using the Flame Con- nect APP.
Flame effect themes
There are different combinations of flame effect available. Different presets
of lighting colour combinations are available and can be cycled through using
the remote control. Further customisation of the effects is accessible through
the smart phone app.
Resetting the Temperature Cutoff Switch
Should the heater overheat, an automatic cut out will turn the whole unit off
and it will not come back on without being reset. It can be reset by turning
the unit off at the main power and waiting 5 minutes before turning the unit
back on. See table Fault Codes on the previous page for more details.
CAUTION: If you need to continuously reset the heater, turn the unit off at the main supply, disconnect panel and call technical support.
Maintenance
WARNING: ALWAYS DISCONNECT FROM THE POWER SUPPLY BEFORE CLEANING THE HEATER.
Cleaning
Before commencing cleaning, unplug the heater and allow it to cool.The
surfaces of the heater should be given an occasional wipe with a dry soft
cloth. Do not use detergents, abrasive cleaning powder or furniture polish as
this can damage the surface finish of the product.
To remove any accumulation of dust or fluff, the soft brush attachment of a vacuum cleaner should occasionally be used to clean the outlet grille of the fan heater located above the front glass.
To clean the fuel effect, remove the fuelbed media. The plastic tray should be wiped clean with a damp cloth. When dry, replace the logs/crystals onto the fuelbed and arrange for best effect.
The front and side glass are cleaned in the factory during the assembly operation. During shipment, installation, handling, etc., the front and side glass may collect dust particles; these can be removed by dusting lightly with a clean dry cloth.
To remove fingerprints or other marks, the partially reflective glass can be cleaned with a damp cloth. The partially reflective glass should be completely dried with a lint free cloth to prevent water spots. To prevent scratching, do not use abrasive cleaners.
CAUTION : Assembly, installation and repair of this heater must be carried out by Dimplex or its authorised agent.
CAUTION: We recommend that this heater is checked annually for safety by a qualified electrician.
Additional Information
fter Sales Service
Your product is guaranteed for one year from the date of purchase. Within this
period, we undertake to repair or exchange this product free of charge
provided it has been installed and operated in accordance with these
instructions. Your rights under this guarantee are additional to your
statutory rights, which in turn are not affected by this guarantee.
CAUTION : Do not use if the heater’s mains power lead is damaged. Such use may cause a hazard. If damaged, the mains power lead must be replaced by the manufacturer or its authorised dealer.
Recycling
For electrical products sold within the European Community – At the end of the
E electrical product’s useful life, it is not be disposed of with household
waste. Please recycle where facilities exist. Check with your Local Authority
or retailer for recycling advice in your country.
VVT75 – Ceramic Log
VVT100 – Ceramic Log
VVT150 – Ceramic Log
**Fig. 18
** No Gaps in the Ash dust.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>