ENFORCER NR-P101E-TQ Gigabit PoE Extenders Installation Guide
- June 13, 2024
- ENFORCER
Table of Contents
ENFORCER NR-P101E-TQ Gigabit PoE Extenders
Product Information
The Gigabit PoE Extenders are devices designed to extend the range of PoE (Power over Ethernet) devices. They come in three models: NR-P101E-TQ, NR- P102E-TQ, and NR-P401E-TQ.
-
Model: NR-P101E-TQ
-
PoE Standards: IEEE 802.3af, IEEE 802.3at
-
PoE Out IP rating: IP66*
-
Model: NR-P102E-TQ
-
PoE Standards: IEEE 802.3af, IEEE 802.3at, IEEE 802.3bt (4
pairs, 90W) -
PoE Out IP rating: Indoor
-
Model: NR-P401E-TQ
-
PoE Standards: IEEE 802.3af, IEEE 802.3at, IEEE 802.3bt (4 pairs, 60W)
-
PoE Out IP rating: Indoor
*With weather-resistant UTP cable Can be used outdoors with an IP66 sealed box and weather-resistant UTP cables.
The Gigabit PoE Extenders can extend the range of PoE devices an additional 328ft (100m) with Cat5e cables or higher. The maximum extended range is up to 984ft (300m) using two extenders. They are suitable for connecting 10/100/1000BASE-T PoE devices including IP cameras, IP access control, and VOIP.
Additional features:
-
NR-P101E-TQ: IP66 Weatherproof with weather-resistant UTP
cable -
NR-P401E-TQ: 4 Output ports for up to 4 PoE devices
Product Usage Instructions
To use the Gigabit PoE Extenders, follow these steps:
- Identify the model of the extender you have: NR-P101E-TQ, NR-P102E-TQ, or NR-P401E-TQ.
- Ensure that you have the necessary parts listed in the Parts List section of the user manual.
- Connect the PoE In port of the extender to the power source using a weather-resistant RJ45 cable (for NR-P101E-TQ) or a shielded RJ45 cable (for NR-P102E-TQ and NR-P401E-TQ).
- If using NR-P401E-TQ, connect the PoE Out ports to your PoE devices using shielded RJ45 cables.
- If using NR-P101E-TQ, ensure that you use weather-resistant UTP cables for outdoor usage and connect them to the PoE Out port.
- If required, mount the extender on a wall using the provided wall-mount brackets, plastic wall anchors, and extender bracket mounting screws.
- Refer to the user manual for specific power input and output requirements for each model.
For more detailed instructions and safety information, please refer to the provided user manual..
Gigabit PoE Extenders
Installation Manual
Model | PoE Standards | PoE Out | IP rating |
---|---|---|---|
NR-P101E-TQ | IEEE 802.3af, IEEE 802.3at | 1 | IP66* |
NR-P102E-TQ | IEEE 802.3af, IEEE 802.3at, IEEE 802.3bt (4 pairs, 90W) | 1 |
Indoor†
NR-P401E-TQ| IEEE 802.3af, IEEE 802.3at, IEEE 802.3bt (4 pairs, 60W)| 4|
Indoor†
With weather-resistant UTP cable †Can be used outdoors with an IP66 sealed box and weather-resistant UTP cables
-
Extends the range of PoE devices an additional 328ft (100m) with Cat5e cables or higher
-
Maximum extended range of up to 984ft (300m) using two extenders
-
Connects 10/100/1000BASE-T PoE devices including IP cameras, IP access control, VOIP, IP speakers/intercoms, etc.
-
Supports up to gigabit transmission rates
-
Passive operation – no external power required and easy plug-and-play installation
-
Automatically detects PoE equipment and protects from damage due to faulty installation
-
Surge protection for both data and power ports
NR-P101E-TQ: -
IP66 Weatherproof with weather-resistant UTP cable
NR-P401E-TQ: -
4 Output ports for up to 4 PoE devices
Parts List
All
- 1x PoE Extender
- NR-P101E-TQ includes 2x End caps
- NR-P401E-TQ includes 2x Wall-mount brackets
- 2x Plastic wall anchors
- 1x Manual
- 2x Wall-mounting screws
- 4x Extender bracket mounting screws
Specifications
Model| NR-P101E- TQ| NR-P102E- TQ| NR-P401E-
TQ
---|---|---|---
Connections| PoE In| 1x Weather-resistant RJ45| 1x Shielded RJ45
PoE Out| 1x Weather-resistant RJ45| 1x Shielded RJ45| 4x Shielded RJ45
Power Input| Power Output
Transmission **range***
| ****
656ft (200m)
| 15W| 11.1W| 11.1W| 4-port<11.1W
30W| 19W| 19W| 4-port<19W
60W| N/A| 40W| 4-port<40W
90W| N/A| 48W| 4-port<40W
948ft (300m)
| 15W| 6.8W| 6.8W| N/A
30W| 15W| 15W| N/A
60W| N/A| 30W| N/A
90W| N/A| 30W| N/A
Data link| Both pin 1/2, 3/6 and 4/5, 7/8
Power link| Pin 1/2(+), 3/6(–)
up to 25W
| Pin 1/2 (–), 3/6 (+) and
4/5 (+), 7/8 (–), up to 85W
| Pin 1/2(+), 3/6(–) up to 12W/4 PSE, 25W/2 PSE
Network cables| Weather-resistant Cat5e or higher| Shielded Cat-5e or
higher
Ethernet speed| 10/100/1000 Mbps half/full duplex
PoE standard
| ****
IEEE 802.3af, IEEE 802.3at
| IEEE 802.3af, IEEE 802.3at, IEEE 802.3bt
(4 pairs, 90W)
| IEEE 802.3af, IEEE 802.3at, IEEE 802.3bt
(4 pairs, 60W)
LED
Indicators
| Power| ****
None
| Green = PoE power in| Yellow
PoE| Green = PoE switch on| Yellow
Data link| LAN x2 green (steady = link,
flashing = transmit)
| Green, steady
Data transmit| Green flashing
IP Rating
| IP66 (with weather-resistant UTP
cable)
| ****
None†
Operating humidity| 90% (maximum, non-condensing)
Operating temperature| -13°~101° F (-25°~55° C)| 14°~122° F (-10°~50°
C)| 14°~113° F (-10°~45° C)
Dimensions| 71/4″x13/4″x13/4″
(185x45x45 mm)‡
| 39/16″x21/16″x11/8″
(90x52x29 mm)
| 411/16″x11/8″x33/8″
(119x28x85 mm)
Weight| 8-oz (227g)| 7.2-oz (204g)| 8.8-oz (250g)
*The maximum range depends on the actual operating conditions, PoE device power requirements, and the type of PoE device. Cat5e/6 Ethernet cables are recommended.
The NR-P401E-TQ and NR-P102E-TQ can be used outdoors with an IP66 sealed box
and weather-resistant UTP cables. ‡Including endcaps
Overview
Sample CCTV Application
Installation
- Determine the proper location for mounting the extender between the PoE power source and the PoE camera, ensuring that neither cable exceeds 328ft (100m) in length.
- Mount the extender (except NR-P401E-TQ) with 4 screws (not included) and the mounting tabs.
- NR-P401E-TQ – Attach the mounting brackets to the extender, with the included bracket mounting screws. Drill holes and attach the extender/bracket assembly to the desired location using the two wall mounting screws and, if needed, the plastic wall anchors.
- Ensure that power to the PoE power source and all PoE devices is off.
- Connect the cables from the PoE power source to the PoE In port of the extender.
- Connect the cables from the PoE cameras to the PoE Out port of the extender.
- NR-P102E-TQ – Connect a ground wire with resistance less than 0.5Ω to the grounding screw and move the Extender’s PoE output switch to ON.
- Turn on the PoE power source and wait up to one minute for the devices to start and establish connections.
- Test to ensure that all devices are working properly.
Troubleshooting
PoE device doesn’t function properly
- Ensure that all devices are turned on
- Ensure that the PoE device is functioning by plugging it directly into the PoE switch, computer, etc.
- Double-check that the cables were connected properly
- Run a continuity test on all wires in the cable
- Equipment at both ends must be at the same link speed, 10BASE-T with 10BASE-T, 100BASE-T with 100BASE-T, etc.
- Replace with a higher-grade cable for better performance
- Ensure that cable lengths are within the allowable range and consistent with the remote PoE device power consumption and reduce cable length as needed
- No more than 2 PoE extenders may be used
- Check that power consumption is within the specifications
FCC COMPLIANCE STATEMENT
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO
THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL
INTERFERENCE AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED,
INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
Notice: The changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate the
equipment. IMPORTANT NOTE: To comply with the FCC RF exposure compliance
requirements, no change to the antenna or the device is permitted. Any change
to the antenna or the device could result in the device exceeding the RF
exposure requirements and void user’s authority to operate the device.
IMPORTANT: Users and installers of this product are responsible for ensuring this product complies with all national, state, and local laws and statutes related to monitoring and recording audio and video signals. SECO- LARM will not be held responsible for the use of this product in violation of any current laws or statutes.
IMPORTANT: Users and installers of this product are responsible for ensuring that the installation and configuration of this product complies with all national, state, and local laws and codes. SECO-LARM will not be held responsible for the use of this product in violation of any current laws or codes.
California Proposition 65 Warning: These products may contain chemicals which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.
WARRANTY
This SECO-LARM product is warranted against defects in material and workmanship while used in normal service for one (1) year from the date of sale to the original customer. SECO-LARM’s obligation is limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair or alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship. The sole obligation of SECO-LARM and the purchaser’s exclusive remedy, shall be limited to the replacement or repair only, at SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or property damage of any kind to the purchaser or anyone else.
NOTICE: The SECO-LARM policy is one of continual development and improvement. For that reason, SECO LARM reserves the right to change specifications without notice. SECO-LARM is also not responsible for misprints. All trademarks are the property of SECO-LARM U.S.A., Inc. or their respective owners. Copyright © 2023 SECO-LARM U.S.A., Inc. All rights reserved.
SECO-LARM ® U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606 Website: www.seco-
larm.com Phone:
949-261-2999 |
800-662-0800 Email: sales@seco-