SR01 Security Relay on Akuvox Door Phones User Guide
- June 13, 2024
- Akuvox
Table of Contents
SR01 Security Relay on Akuvox Door Phones
Product Information
The SR01 Security Relay is a device that can be connected to various door phones and access control units. It allows for the proper wiring and configuration of the door phone system, enabling features such as relay triggering and delay timing. The SR01 can be powered either by the door phone or a third-party power supply.
Compatible Devices:
- Door phones: R20, R28, R29, X915, X912, E16
- Access control unit: A02
Important Notes:
- Ensure that the SR01 is wired correctly between the door phone and the door strike.
- If you want to power the SR01 with a third-party power adaptor, make sure it is properly wired to the external 12V power supply.
- Refer to the SR01 wiring quick guide for proper wiring instructions.
Product Usage Instructions
-
Step 1:
Go to the “Access Control” menu and select “Relay” followed by “12V Power Output”. -
Step 2:
If the SR01 security sensor is powered by a third-party power supply, skip Step 1. -
Step 3:
Scroll up on the same page to find the “Security Relay” section. -
Step 4:
Select the appropriate security relay based on your power source:- Select “Security Relay A” if you want to power the SR01 with the door phone. The relay will be connected to the door phone via Relay A.
- Select “Security Relay B” if you want to power the SR01 with a third-party power supply. The relay will be connected to the door phone via RS485.
-
Step 5:
Configure the security relay settings:- Set the relay trigger delay timing (1-10 seconds). This determines the delay between pressing the “Unlock” button and the relay being triggered. The default is 0, meaning the relay is triggered immediately.
- Set the relay hold delay timing (1-10 seconds). This determines the delay after the door is unlocked before the relay is activated.
- Optionally, give a name to the security relay if needed.
- Enable the security relay feature.
You can test the connected SR01 to ensure it is functioning properly.
How to Configure SROI Security Relay on Akuvox Door Phones
Updated on 20 Oct 2022
Scenario
If you need a higher degree of access security and safety, you need an SR01
security relay. Generally, the lock is directly connected to the door phone
relay, but it cannot be very safe when someone walks up to the door and
smashes up the door phone and breaks into the door for burglary and so on. And
here SR01 has a role to play. Because SR01 is installed indoors and controls
the door opening directly, no one can open the door by smashing up the door
phone installed outside. SR01 helps increase access security in all
applications.
Operation Instruction
SROI can be connected to:
- Door phone: R20, R28, R29, X915, X912, E16
- Access control unit: A02
Before you configure the SR01, make sure that:
- You have properly wired up SR01 between the door phone and the door strike.
- You have wired the SR01 to the external 12V power supply if you want it to be powered by the third-party power adaptor.
Note
- You can refer to the SR01 wiring quick guide for the proper wiring.
Operation Procedure
- Go to Access Control > Relay >12V Power Output.
- Select Security Relay A. Note Skip the two steps above if the SROI security sensor is powered by a third-party power supply.
- On the same page, scroll up to Security Relay.
- Select the Security Relay.
- Select Security Relay A for the SR01 to be powered by the door phone. The relay is connected to the door phone via Relay A.
- Select Security Relay B for the SR01 to be powered by the third-party power supply. The relay is connected to the door phone via RS485.
- Set the security relay.
- Set the relay trigger delay timing (ranging from 1-10 Sec.) For example, if you set the delay time as 5 sec. then the relay will not be triggered until 5 seconds after you press the Unlock tab. The default is 0 meaning triggering relay right after you press the unlock tab.
- Set the relay hold delay timing (ranging from 1-10 Sec.) For example, if you set the hold delay time as 5 Sec. then the relay will be delayed for 5 after the door is unlocked.
- Give a name to the security relay if needed, then enable the security relay feature. You can run the test if the connected SR01 works
-