MEAN WELL HLG-40H-12 Constant Voltage + Constant Current LED Driver Owner’s Manual

June 13, 2024
MEAN WELL

MEAN WELL HLG-40H-12 Constant Voltage + Constant Current LED Driver

MEAN WELL HLG-40H-12 Constant Voltage + Constant Current LED
Driver

Features

  • Constant Voltage+ Constant Current mode output
  • Metal housing with class T design
  • Built-in active PFC function
  • Class 2 power unit
  • IP67 / IP65 rating for indoor or outdoor installations
  • Function options: output adjustable via potentiometer; 3 in 1 dimming; Timer dimming
  • Typical lifetime > 62000 hours
  • 7 years warranty

Applications

  • LED street lighting
  • LED high-bay lighting
  • Parking space lighting
  • LED fishing lamp
  • LED greenhouse lighting
  • Type “HL” for use in Class I , Division 2 hazardous (Classified) location.

GTIN CODE

MW Search: https://www.meanwell.com/serviceGTIN.aspx

Description

HLG-40H series is a 40W AC/DC LED driver featuring the dual mode constant voltage and constant current output. HLG-40H operates from 90 ~ 305VAC and offers models with different rated voltage ranging between 12V and 54V. Thanks to the high efficiency up to 89.5%, with the fan less design, the entire series is able to operate for -40 ~ +80 case temperature under free air convection. The design of metal housing and IP67/IP65 ingress protection level allows this series to fit both indoor and outdoor applications. HLG-40H is equipped with various function options, such as dimming methodologies, so as to provide the optimal design flexibility for LED lighting system.

Model Encoding

Model Encoding

Type IP Level Function Note
Blank IP67 Io and Vo fixed In Stock
A IP65 Io and Vo adjustable through built-in potentiometer In Stock
B IP67 3 in 1 dimming function (1~1OVDC, 1OV PWM signal and resistance) In

Stock
AB| IP65| Io and Vo adjustable through built-in potentiometer & 3 in 1 dimming function (1~10 VDC, 10V PWM signal and resistance)| In Stock
D| IP67| Timer dimming function, contact MEAN WELL for details(safety pending).| By request

SPECIFICATION

MODEL| HLG-40H-12| HLG-40H-15| HLG-40H-20| HLG- 40H-24| HLG-40H-30| HLG-40H-36| HLG-40H-42| HLG-40H-48| HLG-40H-54
---|---|---|---|---|---|---|---|---|---
OUTPUT| DC VOLTAGE| 12V| 15V| 20V| 24V| 30V| 36V| 42V| 48V| 54V
CONSTANT CURRENT REGION Note.4| 7.2 ~12V| 9 ~ 15V| 12 ~ 20V| 14.4 ~ 24V| 18 ~ 30V| 21.6 ~ 36V| 25.2 ~ 42V| 28.8 ~ 48V| 32.4 ~ 54V
RATED CURRENT| 3.33A| 2.67A| 2A| 1.67A| 1.34A| 1.12A| 0.96A| 0.84A| 0.75A
RATED POWER| 39.96W| 40.05W| 40W| 40.08W| 40.2W| 40.32W| 40.32W| 40.32W| 40.5W
RIPPLE & NOISE (max.) **Note.2| 150mVp-p| 150mVp-p| 150mVp-p| 200mVp-p| 200mVp-p| 200mVp-p| 200mVp-p| 300mVp-p| 300mVp-p
VOLTAGE ADJ. RANGE| Adjustable for A/AB-Type only (via built-in potentiometer)
10.8 ~ 13.5V| 13.5 ~ 17V| 17 ~ 22V| 22 ~ 27V| 27 ~ 33V| 33 ~ 40V| 40 ~ 46V| 44 ~ 53V| 49 ~ 58V
CURRENT ADJ. RANGE| Adjustable for A/AB-Type only (via built-in potentiometer)
2 ~ 3.33A| 1.6 ~ 2.67A| 1.2 ~ 2A| 1 ~ 1.67A| 0.8 ~ 1.34A| 0.67 ~ 1.12A| 0.58 ~ 0.96A| 0.5 ~ 0.84A| 0.45 ~ 0.75A
VOLTAGE TOLERANCE Note.3| ±2.5%| ±2.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±2.0%| ±1.5%| ±1.0%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME Note.6| 500ms,80ms/115VAC  500ms,80ms/230VAC
HOLD UP TIME (Typ.)| 16ms / 115VAC, 230VAC
INPUT| VOLTAGE RANGE Note.5**| 90 ~ 305VAC           127 ~ 431VDC

(Please refer to “STATIC CHARACTERISTIC” section)

FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| PF≧0.98/115VAC, PF≧0.95/230VAC, PF≧0.92/277VAC @ full load

(Please refer to “POWER FACTOR (PF) CHARACTERISTIC” section)

TOTAL HARMONIC DISTORTION| THD< 20% (@ load≧60% / 115VAC,230VAC; @ load≧75% / 277VAC)

(Please refer to “TOTAL HARMONIC DISTORTION (THD)” section)

EFFICIENCY (Typ.)| 86.5%| 86.5%| 88%| 88%| 88.5%| 88.5%| 88.5%| 89.5%| 89.5%
AC CURRENT (Typ.)| 0.43A / 115VAC           0.24A / 230VAC 0.23A / 277VAC
INRUSH CURRENT(Typ.)| COLD START 50A(t width=210μs measured at 50% I peak) at 230VAC; Per NEMA 410
MAX. No. of PSUs on 16A CIRCUIT BREAKER| 12 units (circuit breaker of type B) / 20 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT| <0.75mA / 277VAC
PROTECTION| OVER CURRENT| 95 ~ 108%
Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT| Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE| 15 ~ 21V| 18 ~ 24V| 23 ~ 30V| 28 ~ 35V| 35 ~ 43V| 41 ~ 49V| 48 ~ 58V| 54 ~ 65V| 59 ~ 68V
Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, re-power on to recover
ENVIRONMENT| WORKING TEMP.| T case= -40 ~ +80℃ (Please refer to “OUTPUT LOAD vs TEMPERATURE” section)
MAX. CASE TEMP.| T case= +80 ℃
WORKING HUMIDITY| 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +80 ℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/ ℃ (0 ~ 60 ℃)
VIBRATION| 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC|

SAFETY STANDARDS Note.8

| UL8750(type ”HL”), CSA C22.2 No. 250.0-08 , BS EN/EN/AS/NZS 61347-1,BS EN/EN/AS/NZS 61347-2-13 independent , GB19510.1,GB19510.14,EAC TP TC 004,KC61347-1,KC61347-2-13(except for AB-type), IP65 or IP67 approved ;
J61347-1,J61347-2-13 (except for B,AB and D-type) ; design refer to BS EN/EN60335-1(by request)
WITHSTAND VOLTAGE| I/P-O/P:3.75KVAC  I/P-FG:2KVAC  O/P-FG:1.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION Note.8| Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (@ load≧60%) ; BS EN/EN61000-3-3,GB17743 and GB17625.1,
EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN61547, BS EN/EN55024, light industry level (surge immunity Line-Earth 4KV, Line-Line 2KV), EAC TP TC 020
OTHERS| MTBF| 3395.8K hrs min. Telcordia SR-332 (Bell core) ; 345.8K hrs min.        MIL-HDBK-217F (25℃)
DIMENSION| 17161.536.8mm (LWH)
PACKING| 0.73Kg; 20pcs/15.6Kg/0.9CUFT
NOTE|

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 2s•c of ambient temperature.

  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1 uf & 47uf parallel capacitor.

  3. Tolerance: includes set up tolerance, line regulation and load regulation.

  4. Please refer to “DRIVING METHODS OF LED MODULE”.

  5. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.

  6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.

  7. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
    complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.

  8. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED driver can only be used behind a switch without permanently
    connected to the mains.

  9. This series meets the typical life expectancy of >62,000 hours of operation when Tease, particularly® point (or TMP, per DLC), is about 75 ºC or less.

  10. Please refer to the warranty statement on MEAN WELL’s website at http:/twww.meanwell.com.

  11. The ambient temperature derating of 3.5 ºC11ooom with fan less models and of s•c11ooom with fan models for operating altitude higher than 2000m(6500ft).

  12. For any application note and IP water proof function installation caution, please refer our user manual before using.
    https://www.meanwell.com/Upload/PDF/LED_EN.pdf

※ Product Liability Disclaimer For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

| | |

BLOCK DIAGRAM

Block Diagram

DRIVING METHODS OF LED MODULE

This series is able to work in either Constant Current mode (a direct drive way) or Constant Voltage mode (usually through additional DC/DC driver) to drive the LEDs.
Driving Methods Of Led Module

DIMMING OPERATION

Dimming Operation

3 in 1 dimming function (for B/AB-Type)

  • Output constant current level can be adjusted by applying one of the three methodologies between DIM+ and DIM-: 1 – 1 0VDC, or 1 0V PWM signal or resistance.

  • Direct connecting to LEDs is suggested. It is not suitable to be used with additional drivers.

  • Dimming source current from power supply: 1 00μA (typ.)
    © Applying additive 1 ~ 1 0VDC
    Dimming Operation
    Dimming Operation

  • Applying additive 10V PWM signal (frequency range 100Hz ~ 3KHz):
    Dimming Operation
    Dimming Operation

  • Applying additive resistance:
    Dimming Operation
    Dimming Operation

Note : In the case of turning the lighting fixture down to 0% brightness, please refer to the configuration as follow, or please contact MEAN WELL for other options.
Using a switch and relay can turn ON/OFF the lighting fixture.
Dimming Operation

OUTPUT LOAD vs TEMPERATURE (Note.10)

Output Load Vs Temperature\(Note.10\)

STATIC CHARACTERISTICS

※ De-rating is needed under low input voltage
Output Load Vs Temperature\(Note.10\)

POWER FACTOR(PF) CHARACTERISTIC

※Tcase at 70℃
Power Factor\(Pf\) Characteristic

TOTAL HARMONIC DISTORTION (THD)

※ 48V Model, Tcase at 70℃
Total Harmonic Distortion \(Thd\)

EFFICIENCY vs LOAD

HLG-40H series possess superior working efficiency that up to 89.5% can be reached in field applications.
※ 48V Model, Tcase at 70℃
Efficiency Vs Load

LIFE TIME

Life Time

MECHANICAL SPECIFICATION

※Blank/D-Type
Mechanical Specification

※A-Type
Mechanical Specification

※B-Type
Mechanical Specification

※AB-Type
Mechanical Specification

WATERPROOF CONNECTION

※ Waterproof connector
Waterproof connector can be assembled on the output cable of HLG-40H to operate in dry/wet/damp or outdoor environment.
Mechanical Specification

Size Pin Configuration (Female)
M12
4-PIN 5-PIN
SA/PIN SA/PIN
Order No. M12-04
Suitable Current 10Amax.
Size Pin Configuration (Female)
--- ---
M15

2-PIN
12A/PIN
Order No.| M1S-02
Suitable Current| 12A max.

◎ CJ04 cable joiner can be purchased independently for user’s own assembly.
MEAN WELL order No. : CJ04-1, CJ04-2.
Waterproof Connection

INSTALLATION MANUAL

Please refer to : http://www.meanwell.com/manual.html

Logo

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals