ANYSECU TK-9900 Mini Mobile Radio User Manual

June 13, 2024
ANYSECU

ANYSECU Logo

TK-9900 Mini Mobile Radio

ANYSECU WP-9900 Mobile FM Transceiver

Matters Need Attention

Please observe the following precautions to prevent fire, personal injury and damage to interphone.

  1. Do not use this machine while driving, it is too dangerous to do so.
  2. This walkie-talkie is designed to use 13.8V DC power supply, and do not use 24V power supply for power supply.
  3. Do not place the machine in a dusty, wet or splashed place, and do not place it on an unstable surface.
  4. If the reception is interfered by the outside, keep the unit away from interfering equipment (such as TV set, generator, etc.).
  5. Do not expose this unit to direct sunlight for a long time or place it near the heating device.
  6. If the machine emits smoke or strange smell, the power should be cut off immediately. After confirming that the machine is safe, send it to the nearest maintenance service station for inspection.
  7. Do not transmit with high power output for a long time, which may cause the intercom to overheat.

Unpacking and Inspection Device

Welcome to the radio. Before use, I suggest you:

  1. Please check the packing box of this product for signs of damage;
  2. Please carefully open the packing box and confirm whether there are items listed in the table below;
  3. If you find that this product and its accessories are lost or damaged during handling, please contact the dealer immediately.
What’s Inside the Box

Inside the Box

Overview of the Front Panel

Overview of Front Panel 01

Note:  The PC port is above the power supply

Overview of Front Panel 02

Overview of Front Panel 03

11: Power Cord
12: Antenna Interface

Same Frequency and Different Frequency Channel Storage Co-channel Storage

  1. Press the required frequency with the keyboard, such as 145.000, press the [MENU] key to display the menu to item, press the [MENU] key to display: 001 flashes (select the number of channels), press the [MENU] key to display CH-001 once, and press the [EXIT] key to save and complete the exit.

  2. Press the required frequency with the keyboard: for example, 146.000, press the [MENU] key to display 47 items in the menu, press the [MENU] key to display 002 flashing (select the number of channels), press the [MENU] key once to display CH-002, and press the [EXIT] key to save and complete the exit.

  3. Display channel in section a: in item 29 of the menu, press the “menu” key to display the dishes
    Monotonic to item 29
    Press the [MENU] key. The FREQ flashes and is selected with the knob. CH shows the channel, FREQ shows the frequency + channel number, and press the [MENU] key to confirm.

  4. Section b display channel: in item 30 of the menu, press the [MENu] key to display the dishes
    Monotonic to 30 items, display
    Press the [MENU] key FREA flashes, use the knob to select. CH shows the channel, FREQ shows the frequency + channel number, and press the [MENU] key to confirm.

  5. Exit the menu, press PTT, and use the [EXIT/AB] key to switch.

Inter-Frequency Channel Storage (Connection Relay Station Operation)

  1. Press the required receiving frequency, such as 164.500, press the [MENU] key to display menu to 47 items, and display MEM-CH/001, then press the [MENU] key 001 to flash, then press the [MENU] key to display CH-001 once, and after receiving and storing, press the [EXIT] key.
  2. Press the required transmission frequency such as 158.800 with the keyboard, press the [MENU] key to adjust the display menu to 47 items, display MEMCH-O01, press the [MENU] key, CH-001 flashes, press the [MENu] key again, and the different frequency storage is completed, and press the [EXIT] key.

Different Frequencies Plus CTCSs/DCS Channel Storage (Connected to Relay Station Operation)
(Take receiving 465.525 sub-audio, 67.0 rounds and 455.525 sub-audio DO23N as an example)

  1. Press [[MENU key to display the menu, adjust to 11 items to display R-CTCS/OFF, press [MENU] key to display OFF flashing, use knob to select and receive sub-audio data (67.0), and press [menu] key to confirm.
  2. Use knob to select 12 menus T-DCS/OFF, then press [MENU] key to display OFF flashing, and use knob to select and transmit digital sub-audio data (DO23N), press the [MENU] key to confirm that [EXIT] is pressed.
  3. Adjust the receiving frequency (press the required receiving frequency of 465.525 with the keyboard), press the [MENU] key to adjust to 47 menus, display MEM-CH/001, then press the [MENU] key 001 to flash, press the [MENU] key to confirm, display CH001, receive and store, and press [EXIT] to exit.
  4. Press the required radio frequency point with the keyboard, press [MENU] to adjust to 47 items to display MEM-CH001, then press [MENU] to display CHO01 flashing, press [MENU] to confirm, and press [EXIT] to exit the transmission and storage.

Menu Function Setting Operation Menu Function Setting Operation (which can be operated by keyboard)

  1. [MENU]+[0 Key]: TDR turns on and off the dual-frequency standby setting. ON is on, which can realize the simultaneous standby waiting of the upper and lower group frequencies on the screen. OFF is off, only waiting for the frequency indicated by the arrow on the screen. After adjustment, press the [MENU] key to store the parameters.

  2. [MENU]+[1 Key]: STEP sets the step value of frequency in frequency mode. It can be set as: 2.5khz, 5khz, 6.25khz, 10khz, 12.5khz and 25khz. After adjustment, press the [MENU] key to store the parameters.

  3. [MENU]+[2 key]: setting the squelch level of SQL receiver, which is divided into 10 levels to set the squelch depth according to the use environment. 0 is mute on; 1-9 is mute depth increasing; after adjustment, press [F Key] to store parameters.

  4. [MENU]+[3 Key]: TXP transmit power setting. HIGH is high power output and LOW is low power output. After adjustment, press the [MENU] key to store the parameters.

  5. [MENU]+[4 Key]: SCR voice encryption scrambling setting. ONTO turn it on, call voice encryption can be realized. OFF is off. After adjustment, press the [MENU] key to store the parameters. (This function is optional)

  6. [MENU]+[5 Key]: TOT emission time limit setting. Set the transmission time of each intercom. The value ranges from 15 to 600 seconds, with steps of 15. After adjustment, press the [MENU] key to store the parameters.

  7. VOL: Volume 0,1,2,3, 63 Adjust the output volume of the car platform. The higher the number, the higher the volume.

  8. [MENU]+[7 Key]: WN width and narrow band setting. WIDE is wide band and NARR is narrow band. After adjustment, press the “MENU]” key to store the parameters.

  9. [MENU]+[8 key]: automatic backlight time setting of ABR screen. OFF sets the screen to be always on, and the value of 1-50 seconds can adjust the backlight time of the screen. After adjustment, press the [MENU] key to store the parameters.

  10. [MENU]+[9 Key]: BEEP tone switch. OFF is off and ON is on. After adjustment, press the [MENU] key to store the parameters.

  11. [MENU]+[1 Key]+[0 Key]: R-DCS receives digital sub-audio Setup. OFF means off, DO23N-D754N is a forward standard digital sub-audio sequence, and DO23l-D754I is a reverse standard digital sub-audio sequence. After adjustment, press the [MENU] key to store the parameters.

  12. [MENU]+[1 Key]+[1 Key]: R-CTCS receive analog sub-sounds Frequency setting. OFF means off,
    67.0HZ-254.1HZ simulates the standard sequence of mute, and at the same time, you can directly type the standard or non-standard analog mute through the keyboard. After adjustment, press the [MENU] key to store the parameters.

  13. [MENU]+[1 Key]+[2 Key]: T-DCS transmits digital sub-audio
    Setup. OFF means off, DO23N-D754N is a forward standard digital sub-audio sequence, and DO23I-D754I is a reverse standard digital sub-audio sequence. After adjustment, press the [MENU] key to store the parameters.

  14. [MENU]+[1 Key]+[3 Key]: T-CTCS transmit analog sub-sounds Frequency setting. OFF means off, 67.0HZ-254.1HZ simulates the standard sequence of mute, and at the same time, you can directly type the standard or non-standard analog mute through the keyboard. After adjustment, press the [MENU] key to store the parameters.

  15. D-SUB: sub-audio display switch OFF turns off sub-audio display. at this time, ONLY sub-audio symbols are displayed, but the specific values of sub-audio are not displayed. on turns on sub-audio display to display the sub-audio values currently sent and received.

  16. [MENU]+[1 key]+[4 key]: DTMF ST DTMF side tone is on Close the setting. OFF is off, when sending DTMF code, this machine does not send out the sound of this code, and KEY only sends out the sound of this code when pressing the key to send DTMF code. ANI only sends out the sound of the code when it sends the code automatically. BOTH key code sending and automatic code sending are sent locally

  17. [MENU]+[1 Key]+[6 Key]: SC-ADD scan and add settings Set. When the storage channel is turned OFF, the stored channel is not added to the scan list. When storing channels ON, the stored channels should be added to the scan list. After adjustment, press the [MENU] key to store the parameters.

  18. [MENU]+[1 Key]+[7 Key]: PRI-SC priority scanning setting. OFF turns off priority scanning, and ON turns on priority scanning. After adjustment, press the [MENU] key to store the parameters.

  19. [MENU]+[1 Key]+[9 Key]: SC-REV scanning recovery mode Setup. TO scan in time mode. After receiving the carrier signal, it will stay for a period of time and continue scanning. CO scans in carrier mode, and stops scanning when receiving carrier signal. SE scans in search mode and receives carrier signal

  20. [MENU]+[2 Key]+[0 Key]: OPTSIG signaling mode setting. OFF means no signaling, DTMF means dual audio signaling, 2TONE means two-tone signaling, and 5TONE means five-tone signaling. After adjustment, press the
    [MENU] key to store the parameters. Stop scanning when the signal and signaling match with this machine at the same time. After adjustment, press the [MENU] key to store the parameters.

  21. [MENU]+[2 Key]+[1 Key]: SPMUTE speaker turn-on mode setting. QT turns on the speaker for matching the received sub-audio with the sub-audio set by this machine. If no sub-audio is set, the speaker will be turned on after receiving the carrier. AND turns on the HORN when the received sub-audio and optional signaling match with the sub-audio and optional signaling set by the local machine, or turns on the horn when the received sub-audio and optional signaling match with the sub-audio and optional signaling set by the local machine, or turns on the horn after receiving the carrier if no sub-audio is set. After adjustment, press the [MENU] key to store the parameters.

  22. [MENU]+[2 key]+[1 key]: PTT-id PTT-id transmission setting. OFF means no ID code is sent during transmission, BOT means ID code is sent at the beginning of transmission, EOT means ID code is sent at the end of transmission, and BOTH means ID code is sent at the beginning and end of transmission (ID code is the signaling information code in dial-up memory preset by PC software, which can be selected through item 24 of menu). After adjustment, press the [MENU] key to store the parameters.

  23. [menu]+[2 key]+[2 key]: PTT-lt PTT-id transmission delay setting. 0-30 delay time before sending ID code (in seconds). After adjustment, press the [MENU] key to store the parameters.

  24. [MENU]+[2 Key]+[4 Key]: S-INFO signaling information and automatic Dial up memory. 1-15 groups of signaling encoding and decoding memories. You can only write with PC software. After adjustment, press the [MENU] key to store the parameters.

  25. [MENU]+[2 Key]+[5 Key]: EMC-TP alarm mode setting Set. ALARM is the alarm tone sent by this machine, ANI is the alarm code and local identity code sent when alarming, and BOTH alarm tones and local identity codes are sent by this machine when alarming. After adjustment, press the
    [MENU] key to store the parameters.

  26. [MENU]+[2 Key]+[6 Key]: EMC-CH alarm channel setting Set. 000-199 Channel, the designated alarm channel when alarming, and ch is displayed as an effective channel in front of this channel. After adjustment, press the [MENU] key to store the parameters.

  27. [MENU]+[2Key]+[6key] sIG-BP: signaling includes Effective tips. OFF turns off the optional signaling without reminding when it is valid.

  28. [MENU]+[2 Key]+[ 7Key]: CHNAME channel name Series. In channel mode, edit the channel name of the current channel. After adjustment, press the [MENU] key to store the parameters.

  29. [menu]+[2 key]+[8 key]: ca-mdfa channel display settings Set. In Channel mode, FREQ is displayed as frequency, ch is displayed as channel number, and NAME is displayed as channel name (specific name is set in writing frequency software). After adjustment, press the [MENU] key to store the parameters.

  30. [menu]+[2 key]+[9 key]: CB-MDF b channel display settings Set. In Channel mode, FREQ is displayed as frequency, ch is displayed as channel number, and NAME is displayed as channel name (specific name is set in writing frequency software). After adjustment, press the
    [MENU] key to store the parameters.

  31. CC-MDF:C- channel shows that area c is in channel mode, Channels are displayed in frequency. Area C is in channel mode, the channel is displayed by channel number. C zone is in the letter. In channel mode, channels are displayed by channel name (the specific name is set in the writing frequency software)

  32. LANGUA: menu language ENG menu is displayed in English. The menu is displayed in Chinese.

  33. DMR_TX: multi-guard transmission TRACK tracking received The frequency point of transmission. The FIXED main frequency is always transmitted at the main frequency.

  34. VOX: voice control transmission is OFF, 1, 2, 3, ¦ 10 OFF voice control transmission is off, 1,2,3,¦ 10 is voice control Start the sensitivity level. The larger the value, the more generous the sound Can start.

  35. VOX-T: Voice control delay 0,1,2,3,¦ 20 OFF
    Launch off, 1, 2, 3, … 10 is voice-activated and sensitive Degree level, the greater the value, the more generous the sound can be started.

  36. AUTOLK: keyboard auto lock OFF turns off keyboard auto lock. ON turns on the keyboard automatic locking function.

  37. ST-FC: Status character display above the character color of status bar Color settings.

  38. MF-FC: Color of dominant characters Display color of dominant characters Setup.

  39. SFA-FC:A- character color a channel display area character color Color settings.

  40. SFB-FC:B- character color b channel display area character Color settings.

  41. Sfc-fc: c-character color c channel display area character color Color settings.

  42. SUB-FC: mute character color sub-audio display character color

  43. FM-FC:BATT color battery/radio frequency display character Color.

  44. SIG-FC: the display color of the status bar at the bottom of the signal bar character color.

  45. MENUFC: menu character color menu character when setting menu Display color.

  46. TX-FC: transmission-character color is displayed when the currently active channel is transmitted Show color.

  47. RX-FC: receive-the currently active channel of character color is received Display color when carrier wave is used.

  48. MEM-CH: channel storage 000,¦,199 storage letter Channel, used to indicate the channel number to be stored, if Show CH- in front of the number, indicating that channel parameters are originally stored in the channel.

  49. DEL-CH: channel deletion 000,¦,199 deletion designation channel parameters of the channel, if there is no CH- table before This channel has no parameters, and the operation is invalid

  50. SFT-D: frequency difference direction setting. OFF off, at frequency In mode, there is no frequency difference between transmitting frequency and receiving frequency +plus In frequency mode, the transmitting frequency is equal to the receiving frequency plus Frequency difference frequency. -frequency reduction in frequency mode, transmission frequency is equal to the receiving frequency MINUS the frequency difference frequency.

  51. OFFSET: frequency difference frequency setting. 000.000 in frequency mode type, the difference between the transmitting and receiving frequency (whether to poor frequency poor direction control)

  52. ANI: ID code setting XXXXX is used to observe the setting of this machine identity code (this identity code can only be written by writing software)

  53. ANI-L ID code length 3,4,5 Effective length of local ID code

  54. REP-S: transit signaling settings. 1000, 1450, 1750, 2100, when transmitting, the single frequency emitted when the CALL key is pressed tone frequency, used to activate relay station.

  55. TMR-MR:OFF, OFF 1, 2, 3,¦50
    Main frequency return delay time during multi-frequency waiting

  56. STE: Direct Frequency Tail Elimination OFF Close Close Call Tail EliminatiON function on turn on turn on the call ending elimination function

  57. RP-STE: relay ending elimination, OFF, 1, 2, 3, … 10 eliminates the tail sound generated when relaying

  58. RPT-DL: relay tail delay, OFF, 1, 2, 3, … 10 detect the tail sound of the relay to confirm that the relay is effective.

  59. DTMF-G: DTMF gain 0, 1,2,3, ¦ 60 set DTMF gain, the larger the value, the other party receives this machine the stronger the DTMF signal sent out,

  60. Reset: the vfo menu is initialized, and ALL restores the factory settings menu and channel initialization

Manual Channel Storage and Delete Operation Channel Storage

  1. Enter the frequency to be used directly with the keyboard in frequency mode. For example, the frequency of 435.125MHZ can be directly input into 4, 3, 5, 1, 2 and 5.
  2. Set the receiving sub-audio frequency to be used (menu items 10 and 11) and the transmitting sub-audio frequency to be used (menu items 12 and 13). For example, when receiving sub-audio at 67.0HZ and transmitting sub-audio at 67.0HZ, you can press [MENU] +[1] +[MENU] +[DOWN] to select 67.0HZ+[MENU] +[EXIT/AB] to exit from saving and receiving sub-audio. To transmit sub-audio, press [F] +[1] +[3] +[MENU] +[DOWN], select 67.0HZ+[MENU]+[EXIT/AB] to exit saving. (If you don’t need sub-audio, you can all select OFF)
  3. Select menu item 47 for channel storage, and press [MENU] +[4] +[7] +[MENU] +[UP] (DOWN) to select channel number +[MENU] to store channels in turn.

Channel Deletion

Select menu item 37 to delete the channel. Press [MENU] +[4] +[8] +[MENU] +[UP] (DOWN) to select the channel number to be deleted +[MENU] to delete the channel.

Store Radio Channel
You can store radio programs and corresponding program names through PC frequency writing software. (click on FM channel of frequency writing software to edit). The microphone handle of this machine can send DTMF codes in real time in the transmitting state. In FM mode, press the [*] key on the microphone keyboard to search radio channels in sequence.

Switch Keyboard Lock
Press the key [#] of the microphone keyboard for more than 2 seconds during standby time to turn on or off the keyboard lock function.

Send Transit Signaling
Select the transfer signaling frequency to be sent (this machine provides four transfer signaling frequencies). Press [MENU] +[4] +[2] +[MENU]+[up] (down) to select relay signaling frequency +F to save. Press the [PTT] key and then press the [CALL] key to send the preset relay signaling.

Setting of PTTID
The PTT-ID sent by this machine is the ID code prestored by the writing software. You can write by PC frequency writing software (click PTT-ID option box of optional parameter options of frequency writing software to edit.)

  1. Select item 20 in the menu to select the signaling to be used. Press [MENU] +[2] +[0] +[MENU] +[UP] (DOWN) to select the signaling to be used +[MENU] to save.
  2. Select item 23, S-INFO signaling code 1,-“,15 in the menu, and send out this group of information codes when necessary (the information codes can only be written by writing frequency software)
  3. Select item 22 in the menu to set PTT transmission delay. Press [MENU] +[2] +[2] +[MENU] +[UP] (DOWN) to select delay time +[MENU] to save.
  4. Press PTT to send the set ID code.

Optional Signaling Settings DTMF Signaling Settings

This machine has DTMF coding and decoding function. You can write the signaling information code through PC and frequency software (click the signaling editing DTMF option of frequency software to set it).

DTMF Signaling

After the receiver sets DTMF signaling, when receiving DTMF signal and preset body. When the codes are consistent, the receiver will be able to execute the ringing caption and display the information code. In the effective time, you can talk back and forth (the identity code can be written by PC frequency software) to preset.

Patrol Function
When the received DTMF signal is consistent with the preset patrol code, the receiver will send it from identity code, which can be displayed on the main control screen. This function can choose whether it is controlled by the master ID, and not by the receiving signaling. (the patrol code may to be preset by PC writing frequency software).

Monitoring Function
When the received DTMF signal is consistent with the preset monitoring code, the receiver will start to transmit the sound that can monitor the surrounding environment in real time. This function can choose whether it is controlled by the master ID, and not by the receiving signaling. (the monitoring code can be preset by PC writing software).

Telehalo Function
When the received DTMF signal is consistent with the preset tele-halo code, the receiver will limit the transmitting function to work only in the receiving state, and the display will prompt. The normal function cannot be restored until the corresponding boot code is received. This function can choose whether it is controlled by the master ID, and not by the receiving signaling. (Telehalo code can be preset by PC writing frequency software).

Remote Death Function
When the received DTMF signal is consistent with the preset remote code, the receiver will restrict the use of all functions, and the display will prompt. The normal function cannot be restored until the corresponding boot code is received. This function can choose whether it is controlled by the master ID, and not by the receiving signaling. (the remote code can be preset by PC writing frequency software).

Boot Function
When the received DTMF signal is consistent with the preset boot code, the receiver will cancel the function of returning to normal from remote death and halo. This function can choose whether it is controlled by the master ID, and not by the receiving signaling. (the power-on code can be preset by PC writing software).

Alarm Function
When the received DTMF signal is consistent with the preset alarm code, the receiver will give an alarm, and the alarm mode and alarm channel can be edited through the optional parameter options of PC frequency writing software. This function is not controlled by master control ID and receiving signaling. (the alarm code can be preset by PC writing software).
Signaling is controlled by master ID, which means that besides signaling code, master ID must be consistent to perform this function.
Coding format not controlled by master control ID: signaling code+# (separator code)+information code
Coding format controlled by master control ID: signaling code+# (separation code)+master control ID code+# (separation code)+information code

CALL Key to Send DTMF Settings

  1. Select DTMF signaling. Press [MENU] +[1] +[9] +[MENU] +[UP] (DOWN) to select DTMF signaling+[menu] to save.
  2. Select signaling information code. Press [MENU] +[2] +[4] +[MENU] +[UP] (DOWN) to select decoded signaling information code group (1-15)+[menu] to save. (DTMF coding can be set by PC frequency writing software)
  3. Press [CALL] in standby mode to send out the selected

DTMF Information Code Group

CALL key sends 2 tones and 2 tones signaling settings

  1. press the [MENU] key (menu function key) to select item 14 OPTSIG and then press the [MENU] key to select 2TONE to start 2TONE signaling.
  2. Press the [MENU] key to select the 24th item S-INFO, and then press the [Menu] key to select the pre-programmed signaling group numbers 1-16. (use of 2TONE can be set by PC writing software)
  3. When the received 2TONE signal is consistent with the preset 2TONE code, the corresponding function will be executed.
  4. Press the [CALL] key in standby mode to send the selected 2TONE information code group.

5TONE Signaling Setup

This machine has 5-tone codec function. You can write the signaling information code through PC frequency writing software (click the signaling editing 5TONE option of the frequency writing software to set it). After the receiver sets 5TONE signaling, when the received 5TONE signal is consistent with the preset identity code (the identity code must be 5 digits), the receiver will be able to perform the ringing caption and display the information code. You can talk back and forth within the effective time (the identity code can be preset by PC frequency writing software), and the [CALL] key sends 5TONE.

  1. Press the [MENU] key (menu function key) to select the 20th OPTSIG and then press the [F] key to select 5TONE to start 5TONE signaling.
  2. Press the [menu] key to select the 24th item S-INFO, and then press the [F] key to select the pre-programmed signaling group numbers 1-16. [5TONE information code can be set by PC writing frequency software. Each group can send 3 groups of 5TONE codes at a time, and you can choose not to fill them out as needed.
  3. Press the [CALL] key in standby mode to send the selected 5TONE information code group.

Hand Microphone Description

Hand Microphone Description

Hand Microphone Description (Option 2)

Hand Microphone Description \(Option 02\)

  1. Short press MOMI and long press power on
  2. Short press CALL and long press ALARM
  3. “MENU” function key
  4. “UP”: frequency step upward
  5. “DOWN”: frequency step down
  6. EXIT/VM “,exit AB channel switching, alarm function
  7. /SCAN”: frequency reversal function, scan, number”
  8. “#/LOCK”: keyboard lock function, number “#”
  9. 0 “:the number 0
  10. 1 “:the number 1
  11. 2 “:the number 2
  12. 3 “:the number 3
  13. 4 “:the number 4
  14. 5 “:the number 5
  15. 6 “:the number 6
  16. 7 “:the number 7
  17. 8″:the number 8
  18. 9″:the number 9

The Key Technical Indexes Overall Specifications

Frequency Range| VHF: 144-148 MHz
UHF: 430-440 MHz
---|---
Number of Channels| 200 Channels
Channel Spacing| 25KHz, 20KHz 12.5KHz
Phase-Locked Stepping| 5KHz, 6.25KHz, 10KHz, 12.5KHz, 15KHz, 25KHz
Operating Voltage| 13.8V DC ±15%
Mute Mode| CTCSS / DCS / 5Tone / 2Tone / DTMF
Frequency Stabilization| ±2.5ppm
Operating Temperature of Degree| -20~+60°C
Measure| 98 (W) x 35 (H) x 118 (D) mm
Weight| 408g

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals