JBC JNA High-Precision Hot Air Control Unit Instruction Manual

June 13, 2024
JBC

JNA High-Precision Hot Air Control Unit

Product Information:

The JNA High-Precision Hot Air Control Unit is a high-quality
hot air control unit designed for precise temperature control. It
comes in three different voltage options: JNA-1UB (120V), JNA-2UB
(230V), and JNA-9UB (100V).

The product features a display screen, pick and place activation
switch, T260 pick & place handle, J125 cartridge range, USB-A
connector, main switch, NH high-precision heater hose set, NAS
stand for NH high-precision heater hose set, power socket, fuse,
USB connector, equipotential connector, and pedal connector. Some
accessories mentioned in the manual, such as the adjustable stand
and cartridges, are sold separately.

The JNA offers an intuitive user interface with quick access to
station parameters. The default PIN is 0105. It also provides
information on power supplied to the heater, current air
temperature, selected air temperature, hot air temperature,
selected air flow, and station information. The menu options allow
users to set station parameters, tool parameters, view hours worked
in each cycle, choose the language, and perform a station reset.
Troubleshooting information is available on the product page at
www.jbctools.com.

To update the station software, users need to download the JBC
Update File from www.jbctools.com/software.html and insert a USB
flash drive with the downloaded file into the station.

The product also includes an adjustable stand (sold separately)
that allows users to adjust the tool holder angle for comfortable
work position. The tool starts/stops blowing when lifted/returned
to the stand. The stand is designed for easy cartridge change
without switching off the station.

Product Usage Instructions:

  1. Changing Cartridges:
  2. Removing:
  * Place the cartridge in the extractor and pull the handle to  

remove it. Use the ring (J325) or umbrella (J125) around the
cartridge as a stop to extract it from the tool.

2. Inserting:
  * Place the handpiece on top of the new cartridge and press down  

slightly.

3. Fixing:
  * Use the holes to fix the cartridge at the right depth. The  

extractor holes also allow correcting the nozzle angle of curved
cartridges. To do this, rotate the tool with the cartridge inserted
in the extractor until the nozzle is in the right position.

INSTRUCTION MANUAL
JNA
High-Precision Hot Air Control Unit

This manual corresponds to the following references: JNA-1UB (120V) JNA-2UB (230V) JNA-9UB (100V)
Packing List
The following items are included:

JNA High-Precision Hot Air Control Unit …………………………………………..1 unit

Power Cord ………………………………………… 1 unit Ref. 0023715 (120V)
0023714 (230V) 0024092 (100V)

Manual …………………………………………………..1 unit Ref. 0031960
2

Features and Connections
JNA High-Precision Hot Air
Control Unit
Display
Pick and Place Activation Switch
T260 * Pick & Place Handle

J125 Cartridge Range
USB-A Connector
Main Switch
NH
High-Precision Heater Hose Set

NAS * Stand for NH High-Precision Heater Hose Set

Power Socket

JNA High-Precision Hot Air
Control Unit

Fuse

USB Connector

Equipotential Connector
Pedal Connector
Auxiliar Connector FAE / Robot Connector

  • not included, sold separately
    3

JNA Work Screen
JNA offers an intuitive user interface which provides quick access to station parameters. Default PIN: 0105

Status Bar
Instant Power Supplied to Heater
Current Air Temp.
Air Temp. Selected

17:14

4m 38s

Hot Air T emp.

Air Flow Selec.

400 ºC 80%

400ºC Selected

Power 45%

Cartridge: J325

Status Indicator
Selected Air flow
Station Information

Menu Options

Set the station parameters.
Station

Tools

Set the tool parameters, such as cartridge recognition (automatic or manual).

Display the hours worked in each cycle.
Counters

It is possible to choose the language from a list.
Language

Reset

Allows you to carry out an overall station reset restoring all the parameters to their default values.

Troubleshooting

Station troubleshooting available on the product page at www.jbctools.com

4

Station Update

Station Update

Download the JBC Update File from

www.jbctools.com/software.html.

Insert the USB flash drive with the

downloaded file into the station.

Update

OK

System Notifications

The following icons will be displayed on the screen’s status bar.

USB flash drive is connected.

Station software update. Press INFO to start the process.

Station is controlled by a PC.

Warning. Press INFO for failure description.

Station is controlled by a robot.

Error. Press INFO for failure description,the type of error and how to proceed.

Adjustable Stand* (Ref. NA-SB)
Adjust the tool holder angle to suit your work position.

Operation
The tool starts/stops blowing when lifted/ returned to the stand.
The stand is designed so that the tool is inserted in a straight line through its opening, rather than being inserted from above, especially when using J325 Cartridges.
*not included, sold separately
5

Changing Cartridges*
Save time and change the cartridge safely without switching the station off.

1. Removing

2. Inserting

NH NH

3. Fixing 1

2

Holes

Place the cartridge in the extractor and pull the handle to remove it. Use the ring (J325) or umbrella (J125) around the cartridge as a stop to extract it from the tool.

Place the handpiece on top of the new cartridge and press down slightly.

Use the holes to fix the cartridge at the right depth (1). The extractor holes also allows correcting the nozzle angle of curved cartridges. To do this, rotate the tool (2) with the cartridge inserted in the extractor until the nozzle is in the right position.

*Important It is essential to insert the cartridge up to the mark for a proper connection.

Mark
Compatible Cartridges
NH works with J125 and J325 Cartridge Ranges. Find the model that best suits your soldering needs at www.jbctools.com

Ø 1 mm Ø 1 mm

Straight

Bent

Ø 3 mm Straight

Ø 3 mm Bent

6

Compatible Accessories*

Grips for NH High Precision Heater Hose Set (Grip Ref. 0024473)

Soft foam grips ensure a better manual control of the tool and greater comfort when working. Easily replace the grips for NH Heater Hose Set using the slip- on tabs.

1. Inserting Tabs

2. Inserting Handle

3. Removing Tabs

Insert the slide-on tabs into the new grip.

Push the grip with the tabs Hold the grip and pull them

onto the handle.

out. Use a pliers if necessary.

Pick & Place*

This tool helps you place and remove SMDs of any size easily thanks to the suction pump.

Pick & Place Ref. T260-A

Metallic Needles & Cup Set Ref. 0026490

Set includes the following needles and cups (2 units of each reference): – Ref. 0026637: 20G, 60º, Ø0.60 mm/0,0236 in – Ref. 0026639: 30G, 60º, Ø0.159 mm/0.00626 in – Ref. 0026638: 25G, 60º, Ø0.26 mm/0.01023 in – Cup Ref. 0940112, used with needle Ref. 0026637
*not included , sold separately
7

Operation
Choose the needle that best fits for the component and the suction cup if needed and start as follows:
Press the button to start/stop the suction

1. Suction

2. Release

Maximum working temp: 250ºC / 482ºF

Insert the needle with the cup for a correct suction process.

Make sure the needle

Once the suction is

does not protrude

activated, cover the

from the cup.

pen hole with your

Hot Air TeHmopt .Air Temp.Air Flow SAeilreFcl.ow Selec.

finger and lift off the

Power

400ºC Sel4e0c0teºdC Selected

PowerTC

TC

mp mp

ProtecoPnrotecon 120ºC Sel1e2c0teºdC Selected

component.

Profile ABPCro/ fiAlier AteBmCp/ Air temp

Lift your finger to release the component.
*not included

8

Pedal P405*
By means of the pedal connection, NH High-Precision Heater Hose Set and the T260 Pick & Place Tool can be activated and deactivated.

The pedal should be plugged in at the rear of the station into its connector, which ist marked with “Pedal”, to use the Pedal functionality.

85-265V 50/60Hz Power 70W Main Fuse T2 A Serial 219801-026 Version 5A
JNA
Station

Made in EU PATENTED
STAND PEDAL
ROBOT AUX

Pedal and Tool Settings

Start Mode

Select menu . Then by pressing

select “TOOL” and confirm with .

Select “PEDAL FUNCTION” and confirm with OK button. Then choose between “HOT AIR” and “SUCTION”. Confirm again with OK button.

Pedal Activation Mode
In both applications, HOT AIR and SUCTION, are 2 different pedal activation modes available. One Touch Mode Press the pedal once to activate the function. Press again to stop te function. Pressed Mode Start the function by pressing the pedal continuously and stop the function by lifting the pedal. The function is active as long as the pedal is kept pressed. Select “PEDAL” confirm with OK button and choose between “PRESS ONCE” and “PRESS CONT”. Confirm again with OK button.
*not included
9

Recommended
For rework jobs the use of the preheaters is highly recommended. Find the preheater that best suits your soldering needs in www.jbctools.com.
Applying high temperatures (350 ºC – 450 ºC / 660 ºF – 840º F) with a hot air tool for a long time can damage both, the printed circuit and the electronic components. In addition, significant temperature differences between two points on a printed circuit board can damage the printed circuit and the electronic components due to the stresses generated by the different expansion of the material. Preheating is a process that minimizes thermal stress and allows the soldering process to take no longer than it should. For most rework processes JBC recommends a preheat temperature between 90 and 130 ºC / 195 and 265 ºF and not exceed a heating rate of 4 ºC/s. With the use of JBC preheaters, a homogeneous and controlled heating is achieved within the recommended parameters.
not included 10

Maintenance

Before carrying out maintenance, always switch the station off and disconnect it from the mains. Allow the equipment to cool down.

Clean periodically

– Clean the station screen with a glass cleaner or a damp cloth.

– Use a damp cloth to clean the casing and the tool. Alcohol can only be used to clean the metal parts.

– Periodically check that the metal parts of the tool and stand are clean so that the station can detect the tool status.

– Periodically check all cables and tubes.

– Replace a blown fuse as follows:

1. Pull off the fuse holder and remove the fuse. If necessary use a tool to lever it off.

2. Insert the new fuse into the fuse holder and return it to the station.

Fuse

Use only with a 250V fuse Employer uniquement avec
un fusible de 250V

Fuse holder

Fuse holder

– Replace any defective or damaged pieces. Use original JBC spare parts only. – Repairs should only be performed by a JBC authorized technical service.

11

Safety
It is imperative to follow safety guidelines to prevent electric shock, injury, fire or explosion. – Do not use the units for any purpose other than soldering or rework. Incorrect use may cause fire. – The power cord must be plugged into approved bases. Make sure that it is properly grounded before use. When unplugging it, hold the plug, not the wire. – Do not work on electrically live parts. – The tool should be placed in the stand when not in use to turn off the hot air. – The soldering tip, the metal part of the tool and the stand may still be hot even when the station is turned off. Handle with care, including during the stand position adjustment. – Do not leave the appliance unattended when it is on. – Do not cover the ventilation grills. Heat can cause inflamable products to ignite. – Avoid the contact of flux with skin or eyes to prevent irritation – Be careful with the fumes produced when soldering. – Keep your workplace clean and tidy. Wear appropriate protection glasses and gloves when working to avoid personal harm. – Utmost care must be taken with liquid tin waste which can cause burns. – This appliance can be used by children over the age of eight and also persons with reduced physical, sensory or mental capabilities or lack of experience provided that they have been given adequate supervision or instruction concerning use of the appliance and understand the hazards involved. Children must not play with the appliance. – Maintenance must not be carried out by children unless supervised.
12

Notes
13

Notes
14

Specifications

JNA High-Prescision Hot Air Control Unit Ref.: JNA-1UB 120V 50/60Hz. Main fuse: T2A. Rated current 0.85A Ref.: JNA-2UB 230V 50/60Hz. Main fuse: T2A. Rated current 0.85A Ref.: JNA-9UB 100V 50/60Hz. Main fuse: T2A. Rated current 0.85A

– Temperature Selection: – Nominal Power: – Cool Mode: – Ambient Operating Temp.: – Air Flow Regulation: – Vacuum: – Connectors:
– Control Unit Dimensions/Weight: (L x W x H)

150 – 450 °C / 300 – 840 °F 70W “Temp. off” is used to blow air at room temperature 10 – 50 ºC / 50 – 122 ºF 0.15 – 2.5 SLPM 53% / 397 mmHg / 15.6 inHg USB-A / USB-B RJ12 for FAE / Robot Pedal / Stand 180 x 170 x 110 mm / 2825 g 7.1 x 6.7 x 4.3 in / 2.96 lb

– Total Package Dimensions/Weight: 370 x 370 x 200 mm / 4200 g

(L x W x H)

14.6 x 14.6 x 7.9 in / 8.95 lb

Complies with CE standards. ESD safe.

15

Warranty JBC’s 2 year warranty covers this equipment against all manufacturing defects, including the replacement of defective parts and labour. Warranty does not cover product wear or misuse. In order for the warranty to be valid, equipment must be returned, postage paid, to the dealer where it was purchased. Get 1 extra year JBC warranty by registering here: https://www.jbctools.com/productregistration/ within 30 days of purchase.
This product should not be thrown in the garbage. In accordance with the European directive 2012/19/EU, electronic equipment at the end of its life must be collected and returned to an authorized recycling facility.

0031960-280923

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)