Oase Set 14000 Filter Set Pump Instruction Manual
- June 13, 2024
- Oase
Table of Contents
FP 1500, 2500, 3500
Operating instructions
Set 14000 Filter Set Pump
|
---|---
WARNING
- Disconnect all electrical devices in the water from the power supply before reaching into the water. Otherwise there is a risk of severe injuries or death by electrocution.
- This unit can be used by children aged 8 and above and by persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they are supervised or have been instructed on how to use the unit in a safe way and they understand the hazards involved. Do not allow children to play with the unit. Only allow children to carry out cleaning and user maintenance under supervision.
Safety information
Electrical connection
-
Special regulations apply for electrical installation in outdoor spaces. Only a qualified electrician may perform the electrical installation.
– The qualified electrician has the necessary professional training, knowledge and experience to perform electrical installation in outdoor spaces. The electrician can detect potential dangers and knows how to adhere to regional and national standards, regulations and directives.
– For your own safety, please consult a qualified electrician. -
Only connect the unit if the electrical data of the unit and the power supply match.
-
Only plug the unit into a correctly installed outlet. Ensure that the unit is fused for a rated fault current of max. 30 mA by means of a fault current protection device.
-
Extension cables and power distributors (e.g. outlet strips) must be suitable for outdoor use (splash-proof).
-
Protect open plugs and sockets from moisture.
Safe operation
- Do not use the unit, if electrical lines or the housing are damaged.
- Dispose of the unit if its power connection cable is damaged. The power connection cable cannot be replaced.
- The impeller unit in the pump contains a magnet with a strong magnetic field that may affect the operation of pacemakers or implantable cardioverter defibrillators (ICDs). Keep a distance of at least 0.2 m between the implant and the magnet.
- Do not carry or pull the unit by its power cable.
- Route lines in such a way that they are protected from damage and do not present a tripping hazard.
- Never carry out technical changes to the unit.
- Only carry out work on the unit that is described in this manual.
- Only use original spare parts and accessories.
- Should problems occur, please contact the authorised customer service or OASE.
Intended use
Only use the product described in this manual as follows:
- For pumping normal pond water for water features and fountains.
- While adhering to the technical specifications.
- Adherence to the permissible water quality.
The following restrictions apply to the unit:
- Do not use in swimming ponds.
- Never use the unit with fluids other than water.
- Never run the unit without water.
- Do not use in conjunction with chemicals, foodstuff, easily flammable or explosive substances.
- Do not connect to the domestic water supply.
- Do not use for commercial or industrial purposes.
Symbols on the unit
| The unit is dust-tight and water-tight down to 2 m.
---|---
| Remove the unit in the event of freezing temperatures.
| Danger for persons with pacemakers. The unit contains a strong magnet.
****| Do not dispose of the unit with the normal household waste.
| Read the operating instructions.
Installation and connection
WARNING
Severe injuries or death due to operation of this unit in a swimming pond.
Defective electrical components will electrify the water with dangerous
electrical voltage.
- Never operate the unit in a swimming pond.
CAUTION
Rotating components in the intake and pressure socket area. Risk of injury
when reaching into the sockets.
In particular, observe the following: A unit that has stopped due to overload
can start up unexpectedly!
- Do not reach into the opening of the intake socket or pressure socket while the power plug is plugged in.
- If the sockets are freely accessible during operation, e.g. if no hoses are connected, use a hand guard to secure the sockets. The hand guard is available as an accessory.
NOTE
If the pump is used for conveying excessively soiled water, the impeller unit
will be subject to increased wear and will require earlier replacement.
- Thoroughly clean the pond or pool before installing the pump.
- Install the pump at a raised level above the bottom. This reduces intake of muddy water.
Connecting
A
Do not plug the power plug into the socket yet!
Installation
B
- Place the pump horizontally on a stable, mud-free surface.
- Ensure secure and stable positioning of the pump.
- Only operate the pump when it is fully submerged.
Commissioning/start-up
NOTE
The unit will be destroyed if it is operated with a dimmer. It contains
sensitive electrical components.
- Do not connect the unit to a dimmable power supply.
NOTE
Prevent the pump from running dry. Otherwise the pump will be destroyed.
- Only operate the pump when it is submerged or flooded.
Switching ON/OFF
-
Switching on: Plug the power plug into the outlet.
– The unit switches on immediately. -
Switching off: Pull the power plug from the outlet.
Maintenance and cleaning
WARNING
Risk of severe injuries or death by electric shock.
- Disconnect all electrical devices in the water from the power supply before reaching into the water.
- Disconnect the unit from the mains before you start working on it.
Cleaning the device
C
**** Clean the unit as required but at least twice per year.
− When cleaning the pump, pay particular attention to the impeller unit and
the pump housing.
-
Recommended cleaning agent for removing stubborn limescale deposits:
– Pump cleaning agent Pump Clean from OASE.
– Vinegar- and chlorine-free household cleaning agent. -
After cleaning, thoroughly rinse all parts in clean water.
Storage/winter protection
The unit is not frost-proof and has to be removed and put into storage if
minus temperatures are expected.
How to correctly store the unit:
- Drain the water remaining in the unit, in the hoses, pipes and connections as much as possible.
- Thoroughly clean the unit.
- Check the unit for damage and replace damaged components.
- Store the pump submerged and in a frost-free environment.
- Protect open plug connections from moisture and dirt.
Malfunction remedy
Malfunction | Cause | Remedy |
---|---|---|
The unit is not operating | No mains voltage | Check mains voltage |
Insufficient delivery rate | Impeller blocked | Clean impeller |
Strainer casing clogged | Clean strainer casing | |
Excessive pressure losses in the hoses | Reduce hose length and connecting |
parts to a minimum, route hoses as straight as possible
Unit switches off after a short running period| Water temperature too high|
Note maximum water temperature
of +35 °C
Wear parts
- Impeller
Disposal
NOTE
Do not dispose of this unit with household waste.
- Dispose of the unit by using the return system provided for this purpose.
- Should you have questions, please contact your local disposal company. They will give you information on how to correctly dispose of the unit.
- Render the unit unusable by cutting the cables.
Type| FP 1500
FP 2500
FP 3500
---|---
Dimensions| 190x175x110 mm
Weight| 1.7 kg
2.0 kg
2.5 kg
Rated voltage| ~ 220-240 V, 50 Hz
Power consumption| 25 W
40 W
70 W
Type| FP 1500
FP 2500
FP 3500
---|---
Max. flow rate| ≤ 1.500 l/h
≤ 2.500 l/h
≤ 3.400 l/h
Max. head height| ≤ 1.9 m
≤ 2.2 m
≤ 2.7 m
Connections| 1”
Water temperature| +4 … +35 ºC
Recommended water quality| Freshwater
---|---
pH value| 6.8 … 8.5
Hardness| 8 DH … 15 DH
Free chlorine| <0.3 mg/l
Chloride content| <250 mg/l
Salt content| <0.4 %
Overall dry residue| <50 mg/l
Temperature| 4 °C … 35 °C
|
---|---
OASE GmbH
Tecklenburger Straße 161
48477 Hostel | Germany
+49 (0) 5454 80-0
+49 (0) 5454 80-9353
info@oase.com