whisper KF-600 230V Wiring Centre
Product Information
- The KF-600 8W Essence Wiring Centre is a wiring control system designed for under-floor heating zones with 230v thermostat zone control. It can be used to control up to 8-floor heating zones.
- The product features a blue LED indicator that signals the energy source for heat. It should not be disposed of in household waste and should be discarded according to local waste and recycling schemes.
Technical Specifications:
- Product Code: CWS WCN8 600
- Dimensions: 100 x 240 x 42mm
- Voltage: 230V AC
- Mounting Type: On Wall/DIN rail mounting
Product Usage Instructions
- Remove the front casing by loosening the two screws on the lower right corner.
- Set aside the front housing for reattachment after completing the final work.
- Secure the wiring center to the wall using the two fixing holes (top left and bottom right corner) or by clipping it to a DIN rail.
- Make the wiring connections as shown in the wiring diagram.
- Reattach the front cover and tighten the screws.
Product Overview
The KF-600 is an 8-way wiring center for controlling the heating systems with a 230v power supply. The KF-600 can be used to control up to 8 under-floor heating zones with 230v thermostat zone control.
- Gold LED pump indicator light when the secondary UFH circulator pump is running.
- Blue LED boiler indicator light when UFH system signals energy source for heat.
- Red LED zone indicator lights when the circuit is open to allow flow to the UFH zone.
- Adjustable pump delay to alleviate stress on the secondary UFH circulator pump.
- Up to 2 thermal actuators per zone allowing up to 16 UFH circuits in total.
Multiple circuits can be controlled by a single zone control thermostat, up to 8 in total.
Technical specifications
- Item 230V Wiring Centre
- Product Code CWS WCN8 600
- Dimensions 100 x 240 x 42mm
- Mounting Type On Wall/DIN rail mounting
- Colour White
- Voltage 230V AC
- Power Consumption <3W
- Max Load Current 3A (per output)
- No. of zones 8
- Working Temp -20–60OC
SAFETY
- This product should be installed by a qualified electrician.
- Ensure that the electrical wiring of the installation and connections to and from the thermostat and any remote sensor connected to it are in accordance with BS7971, the latest edition of IET wiring regulations.
- The thermostat must be wired to the electric mains through a switch capable of disconnecting all poles compliant with the current safety standards and with a contact separation of at least 3mm in all poles.
- Before commencing work on the installation, the electricity supply must be disconnected.
Disposal
This product should not be disposed of in household waste. The product should be disposed of in accordance with your local waste and recycling schemes.
Installation
- Remove the front casing by loosening the two screws on the low side of the wiring center.
- Set aside the front housing, ready to reattach once the final work has finished.
- Secure the wiring center to the wall via the two fixing holes (top left corner and bottom right corner) or by clipping it to a DIN rail.
- Make a wiring connection as shown in the wiring diagram.
- Reattach the front cover and tighten the screws.
Dimensions pictures
LED’s, Dip Switches, and Button Information
- LED 1: this LED is lit when the wiring center has power connected and live.
- LED 2: This LED flashes to confirm wiring center and time controls are all working correctly.
- When the front cover is on and the wiring center is working but with NO call for heat, LED 2 can be seen flashing faintly through the boiler indicator.
- This is okay and normal.
- Dip switches can be used to set the delay of the pump and boiler as shown on the wiring diagram.
- The button can be used to test whether the pump and boiler outputs are working correctly.
- This test overrides the time setting of the dip switches. To test follow the steps below;
- Un-power the wiring center and remove the front cover by loosening the two screws on the lower side.
- Ensure at least one thermostat is set to call for heat or add a link wire to represent a call for heat.
- Push and hold the button using an electrically safe tool.
- Reinstate power to the wiring center and you will see LED 1, and LED 2, and the pump and boiler LEDs come on. Now confirm the boiler and pump are operating.
- This will automatically reset after 20 mins, or un-power the wiring centre.
KF-600 8W Essence Wiring Centre
This product must only be installed by a qualified electrician and comply with
local installation regulations
Whisper Controls Limited
6 Church Green, Witney, Oxon, OX28 4AW, United Kingdom. Tel: +44 (0)1993
640073
whispercontrols.com