Trust ASUN-650 Sun Blinds Switch User Manual

June 9, 2024
Trust

Trust ASUN-650 Sun Blinds Switch

Trust-ASUN-650-Sun-Blinds-Switch-fig- \(1\)

Switch off the mains power (electric meter box) before installing this product

Remove the existing switch

Detach the existing switch and disconnect the wires. The existing wall switch is replaced by this product and can no longer be used. Consult the supplier of your sun blind system when in doubt about motor type and wire colors

Connect 230V power supply

  • Connect the (brown) live wire to the [L] contact.
  • Connect the (blue) neutral wire to the [N] contact.
  • Contact an electrician when in doubt about wire colors.
  • Tighten the clamping screws.

Connect motor wiring

How to connect the motor wiring depends on the type of motor:

  • Read step 5 for a 230V motor.
  • Read step 6 for a 12-24V motor.
  • Read step 7 for a motor with a momentary switch.

Connect 230V motor

  1. Connect the (blue) neutral wire from the motor to the [N] contact.
  2. Use a seperate piece of wire to connect [L] with [COM].
  3. Connect the live wires from the motor (brown and black) to the [ UP ] and [ DOWN ] contact. These positions can be interchanged to reverse the up and down motion of the motor

Connect 12-24V motor

  1. Connect the 24V+ wire to [COM].
  2. Connect switch wires A and B to the [ UP ] and [ DOWN ]contact. These positions can be interchanged  to reverse the up and down motion of the motor.Never connect 230VAC wires to low-voltage wires.

Motor with momentary switch

The motor only has 2 wires.

  1. Connect one wire to [ UP ] and the other wire to [COM]. These positions can be interchanged to reverse the up and down motion of the motor.
  2. Use a seperate piece of wire to connect both [  UP ] and [ DOWN ] contacts. Never connect 230VAC wires to low-voltage wires.

Switch on the mains power (electric meter box) to continue the installation

  • Shock hazard! Do not contact any exposed wiring.
  • Only touch the plastic housing of this product.

Activate learn-mode

  • Press the learn-button on the receiver for 1 second.
  • The learn-mode will be active for 12 seconds and the LED-indicator will blink slowly.

Assign Trust Smart Home transmitter code

While the learn-mode is active, send an ON-signal with any Trust Smart Home transmitter to assign the code to the receiver’s memory.

Code confirmation

The LED indicator of the receiver will blink fast to confirm the code has been received. The receiver can store up to 32 different transmission codes in its memory. The memory will be preserved when the receiver is moved to another location or in case of power failure.

Install the receiver

Install the receiver in a standard junction box or other type of housing (break off the mounting tabs if necessary).
Close the housing with a blind cover.

Manual operation with a Trust Smart Home transmitter

  1. Send an ON-signal to raise the screen.
  2. Send an ON-signal again to stop.
  3. Send an OFF-signal to lower the screen.
  4. Send an OFF-signal again to stop.

Momentary switch only: every command (up/down/stop) needs to be given twice.

Explanation COM-contact

The module contains 2 voltage-free contacts: [ UP ] and [ DOWN ]. In the neutral position, the contact [COM] is not switched. After an on/off signal from a Trust Smart Home transmitter, [COM] switches either to the [ UP ] or [ DOWN ] contact. After 2 minutes, the COM contact switches back to its neutral position.

Single code delete

  1. Press the learn-button for 1 second. The learn-mode will be active for 12 seconds and the LED-indicator will blink slowly.
  2. While the learn-mode is active, send an OFF-signal to delete the code of a specific Trust Smart Home transmitter.
  3. The LED indicator will blink fast shortly to confirm transmitter code deletion.

Full memory delete

  • Press and hold the learn-button on the receiver (aprox. 6 sec.) untill the LED-indicator starts blinking fast. The delete mode will be active for 12 seconds.
  • While the delete mode is active, press the learn button on the receiver again for 1 second.
  • The LED indicator will blink fast shortly to confirm memory deletion.

For information about the SET button please go to www.trust.com/71017

INSTRUCTION STEPS

Trust-ASUN-650-Sun-Blinds-Switch-fig-
\(3\) Trust-ASUN-650-Sun-Blinds-Switch-fig-
\(4\) Trust-ASUN-650-Sun-Blinds-Switch-fig-
\(5\) Trust-ASUN-650-Sun-Blinds-Switch-fig-
\(6\) Trust-ASUN-650-Sun-Blinds-Switch-fig-
\(7\)

TECHNICAL SPECIFICATIONS

Codesystem Automatic
Memory addresses 32
Wattage Max. 1000 Watts
Voltage 230V/50Hz
Voltage to be connected 12-24V DC / 230V AC (potential free)
Size HxWxL: 48 x 48 x 24,5 mm

Safety Instructions

  • Product support: www.trust.com/71017. Warranty conditions: www.trust.com/warranty
  • To ensure safe handling of the device, follow the safety advice on: www.trust.com/safety
  • The Wireless range is strongly dependent on local conditions such as the presence of HR glass and reinforced concrete
  • Never use Trust Smart Home products for life-support systems. This product is not water-resistant. Do not attempt to repair this product. Wire colors may vary per country. Contact an electrician when in doubt about wiring. Never connect lights or equipment that exceed the maximum load of the receiver. Exercise caution when installing a receiver voltage may be present, even when a receiver is switched off. Radio transmission frequency range: 433,92 MHz
  • Disposal of packaging materials – Dispose of packaging materials which are no longer needed in accordance with applicable local regulations.
  • Disposal of the device – The adjacent symbol of a crossed-out wheelie bin means that this device is subject to Directive 2012/19/EU.

Disposal of batteries – Used batteries may not be disposed of in household waste. Only dispose of batteries when they are fully discharged. Dispose of batteries according to local regulations.
Trust Electronics Ltd. declares that item number 71017-02 is in compliance with Directive Electromagnetic Compatibility Regulations 2016, Radio Equipment Regulations 2017. The full text of the declaration of conformity is available at the following internet address: www.trust.com/compliance
Trust International B.V. declares that item number 71017-02 is in compliance with Directive 2014/53/EU – 2011/65/EU.
The full text of the EU declaration of conformity is available at the following web address: www.trust.com/compliance

Declaration of Conformity

Trust International B.V. declares that this Trust Smart Home-product:

  • Model: ASUN-650 Sun blinds switch
  • Item number : 71017-02
  • Intended use : Indoor

Is in compliance with the essential requirements and other relevant provisions of the following directives:
ROHS 2 Directive (2011/65/EU)
RED Directive ( 2014/53/EU)
The full text of the EU declaration of conformity is available at the following web address: www.trust.com/compliance

TRUST SMART HOME LAAN VAN BARCELONA 600 3317DD DORDRECHT NEDERLAND
www.trust.com

Trust Electronics Ltd., Sopwith Dr, Weybridge, KT13 0NT, UK. All brand names are registered trademarks of their respective owners. Specifications are subject to change without prior notice. Made in China.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals