FUJITSU FOP18 iM Heat Pumps User Manual
- June 13, 2024
- FUJITSU
Table of Contents
- Features and Benefits
- Heat Pumps
- Accessories
- Unit Dimensions
- CLEARANCES
- Control Wiring
- Application Guidelines
- Refrigerant Line Size Information
- Refrigerant Line Size Information (Con’t.)
- Integrated Controls
- THE ECONET® SMART THERMOSTAT
- OPERATIONAL FEATURES
- MONITORING & REMOTE CONTROL FEATURES
- GENERAL TERMS OF LIMITED WARRANTY*
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
FUJITSU FOP18 iM Heat Pumps User Manual
Features and Benefits
- EcoNet® Enabled: Automatic system configuration and optimization
- Diagnostics & Bluetooth®1 Connectivity: With the Bleach™ Contractor & Econet® Apps, built-in technology makes advanced set-up, monitoring, troubleshooting, and repairing the product easier than ever before
- Variable Speed Scroll Compressor & Inverter Drive:
- Features variable speed operation from 40 to 100% capacity with the Econet® Smart Thermostat
- Offers overdrive capability up to 115% to maintain performance in extreme conditions
- Provides precise temperature control, advanced humidity control and greater efficiency
- Brushless DC Condenser Motors (BLDC): Enhances reliability and allows for easier serviceability
- Swept Wing Fan Technology: Features quieter operation and improved unit acoustics
The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks is under license. Other trademarks and trade names are those of their respective owners.
Heat Pumps
F. O. P. 18. 24. M. J. A. Z. C. A .1
Brand Product Category Type SEER2 Capacity BTU/HR Type Voltage Region
Refrigerant Controls Major Series Minor Series
Designates Metric Conversions
AVAILABLE MODELS | DESCRIPTION |
---|---|
SP16AZ24AJ3CA | Vantiv™ Line 2 ton 16 SEER2 Variable Speed iM Heat |
Pump-208/230/1/60
SP16AZ36AJ3CA| Vantix ™ Line 3 ton 16 SEER2 Variable Speed iM Heat
Pump-208/230/1/60
SP16AZ48AJ3CA| Vantix ™ Line 4 ton 16 SEER2 Variable Speed iM Heat
Pump-208/230/1/60
SP16AZ60AJ3CA| Vantix ™ Line 5 ton 16 SEER2 Variable Speed iM Heat
Pump-208/230/1/60
STANDARD EQUIPMENT
R-410A Refrigerant
Twin Rotary Compressor
Compressor Sound Blanket
Field Installed Filter Drier
Front Seating Service Valves
Internal Thermal Overload
Long Line capability
Low Ambient capability
3-4-5 Expanded Valve Space
Composite Basepan
15″ Access to Internal Components
Quick release louver panel design
No fasteners to remove along bottom
Optimized Venturi Airflow
Single row condenser coil
Powder coated paint
Rust resistant screws
QR code
External gauge ports
Service trays
General Data
MODEL NO.| SP16AZ24AJ3| SP16AZ36AJ3| SP16AZ48AJ3|
SP16AZ60AJ3
Nominal Tonnage| 2| 3| 4| 5
Valve Connections|
Liquid Line O.D. – in.| 3/8| 3/8| 3/8| 3/8
Suction Line O.D. – in.| 3/4| 3/4| 7/8| 7/8
Refrigerant (R410A) furnished oz.¹| 118| 135| 164| 256
Compressor Type| Twin Rotary
Outdoor Coil|
Net face area – Outer Coil| 14.4| 19.8| 19.8| 24.2
Net face area – Inner Coil| —| —| —| —
Tube diameter – in.| 0.276| 0.276| 0.276| 0.276
Number of rows| 1| 1| 1| 1
Fins per inch| 22| 24| 22| 20
Outdoor Fan|
Diameter – in.| 20| 24| 24| 26
Number of blades| 3| 3| 3| 3
Motor hp| 1/5| 1/5| 1/3| 1/2
CFM| 2754| 4560| 4567| 5477
RPM| 1075| 1000| 1000| 925
Watts| 165| 277| 252| 283
Shipping weight – lbs.| 188| 205| 210| 314
Operating weight – lbs.| 181| 198| 203| 307
Electrical Data
Line Voltage Data (Volts-Phase-Hz)| 208/230-1-60| 208/230-1-60|
208/230-1-60| 208/230-1-60
Maximum overcurrent protection (amps)²| 20| 35| 40| 50
Minimum circuit ampacity5| 12| 21| 25| 30
Compressor
Rated load amps| 9| 13| 18| 22
Locked rotor amps| 65| 68| 96| 119
- Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the installation instructions for information about set length and additional refrigerant charge required.
- HACR type circuit breaker of fuse.
- Refer to National Electrical Code manual to determine wire, fuse, and disconnect size requirements.
Accessories
MODEL NO.| SP16AZ24AJ3| SP16AZ36AJ3| SP16AZ48AJ3|
SP16AZ60AJ3
---|---|---|---|---
EcoNet® Smart Thermostat| CETST800SYS| CETST800SYS| CETST800SYS| CETST800SYS
Compressor crankcase heater*| N/A| N/A| N/A| N/A
Low ambient control| 47-102709-10| 47-102709-10| 47-102709-10| 47-102709-10
Compressor sound cover| 68-23427-27| 68-23427-28| 68-23427-29| 68-23427-29
Low pressure control| 47-103454-01| 47-103454-01| 47-103454-01| 47-103454-01
High pressure control| 47-103669-02| 47-103669-02| 47-103669-02| 47-103669-02
Liquid Line Solenoid (24 VAC, 50/60 Hz)| Solenoid Valve| 200RD2T3TVLC|
200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC
Solenoid Coil| 61-AMG24V| 61-AMG24V| 61-AMG24V| 61-AMG24V
Liquid Line Solenoid (120/240 VAC, 50/60 Hz)| Solenoid Valve| 200RD2T3TVLC|
200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC
Solenoid Coil| 61-AMG120/240V| 61-AMG120/240V| 61-AMG120/240V| 61-AMG120/240V
Weighted Sound Power Level (dBA)
UNIT SIZE – VOLTAGE, SERIES| STANDARD RATING (dBA) HIGH
STAGE LOW STAGE| TYPICAL OCTAVE BAND SPECTRUM (dBA WITHOUT TONE
ADJUSTMENT)
---|---|---
125| 250| 500| 1000| 2000| 4000| 8000
SP16AZ24AJ3| 72.2| 43.5| 56.5| 63.9| 61.4| 59.0| 58.3| 47.9
63.6| 37.8| 48.9| 55.4| 52.7| 49.9| 51.6| 42.4
SP16AZ36AJ3| 72.9| 49.2| 60.5| 64.7| 60.2| 61.3| 59.2| 46.6
59.9| 35.8| 44.8| 51.6| 49.6| 46.9| 45.4| 42.2
SP16AZ48AJ3| 74.3| 46.6| 58.0| 64.2| 61.6| 60.1| 61.3| 49.9
61.5| 35.1| 46.0| 53.8| 47.9| 46.4| 53.5| 42.0
SP16AZ60AJ3| 71.2| 45.7| 56.0| 63.5| 59.7| 57.4| 54.6| 47.9
61.8| 30.9| 45.2| 52.6| 48.6| 50.3| 49.2| 42.1
NOTE: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI)
Unit Dimensions
MODEL NO. | OPERATING | SHIPPING |
---|---|---|
H (Height) | L (Length) | W (Width) |
(Length)** | W (Width) | |
INCHES | mm | INCHES |
mm | INCHES | mm |
SP16AZ24AJ3CA | 27.00 | 685.80 |
32.38 | 822.45 | 32.38 |
SP16AZ36AJ3CA | 35.00 | 889.00 |
36.38 | 924.05 | 36.38 |
SP16AZ48AJ3CA | 35.00 | 889.00 |
36.38 | 924.05 | 36.38 |
SP16AZ60AJ3CA | 45.00 | 1143.00 |
38.38 | 974.85 | 38.38 |
] Designates Metric Conversions
CLEARANCES
Control Wiring
Application Guidelines
- Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01-in. wc.
- Minimum outdoor operation air temperature for cooling mode without low-ambient operation accessory is 55°F (12.8°C).
- Maximum outdoor operating air temperature is 125°F (51.7°C).
- For reliable operation, unit should be level in all horizontal planes.
- Use only copper wire for electric connections at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided.
- Do not apply capillary tube indoor coils to these units.
- Factory-supplied filter drier must be installed.
Refrigerant Line Size Information
16 SEER2 VARIABLE SPEED HEAT PUMPS
UNIT SIZE
| ALLOWABLE LIQUID LINE SIZE| ALLOWABLE VAPOR LINE
SIZE| OUTDOOR UNIT ABOVE OR BELOW INDOOR UNIT EQUIVALENT LENGTH
(FEET)
< 25| 26-50| 51-75| 76-100| 101-125| 126-150
MAXIMUM VERTICAL SEPARATION/CAPACITY MULTIPLIER
2.0 TON*SEE NOTE 3
| 1/4″| 5/8″| 25/1.00| 50/0.99| 33/0.98| 60/0.97| NR| NR
5/16″| 5/8″| 25/1.00| 50/0.99| 50/0.98| 50/0.97| 50/0.96| 50/0.95
3/8″| 5/8″| 25/1.00| 50/0.99| 50/0.98| 50/0.97| 50/0.96| 50/0.95
1/4″| 3/4″| 25/1.00| 50/1.00| 33/0.99| 60/0.99| NR| NR
5/16″| 3/4″| 25/1.00| 50/1.00| 50/0.99| 50/0.99| 50/0.99| 50/0.98
3/8″| 3/4″*| 25/1.00| 50/1.00| 50/0.99| 50/0.99| 50/0.99| 50/0.98
3 TON
| 5/16″| 5/8″| 25/0.99| 50/0.97| 50/0.95| 50/0.93| 36/0.91| NR
3/8″| 5/8″| 25/0.99| 50/0.97| 50/0.95| 50/0.93| 50/0.91| NR
5/16″| 3/4″| 25/1.00| 50/0.99| 50/0.99| 50/0.98| 36/0.97| 20/0.96
3/8″| 3/4″| 25/1.00| 50/0.99| 50/0.99| 50/0.98| 50/0.97| 50/0.96
1/2″| 3/4″| 25/1.00| 50/0.99| 50/0.99| 50/0.98| 50/0.97| 50/0.96
4 TON
| 3/8″| 3/4″| 25/0.99| 50/0.98| 50/0.96| 50/0.95| 50/0.93| 50/0.92
1/2″| 3/4″| 25/0.99| 50/0.98| 50/0.96| 50/0.95| 50/0.93| 50/0.92
3/8″| 7/8″| 25/1.00| 50/0.99| 50/0.99| 50/0.98| 50/0.98| 50/0.97
1/2″| 7/8″| 25/1.00| 50/0.99| 50/0.99| 50/0.98| 50/0.98| 50/0.97
5 TON
| 3/8″| 3/4″| 25/0.98| 50/0.97| 50/0.95| 50/0.93| 46/0.91| NR
1/2″| 3/4″| 25/0.98| 50/0.97| 50/0.95| 50/0.93| 50/0.91| NR
3/8″| 7/8″| 25/0.99| 50/0.99| 50/0.98| 50/0.97| 50/0.96| 38/0.95
1/2″| 7/8″| 25/0.99| 50/0.99| 50/0.98| 50/0.97| 50/0.96| 50/0.95
3/8″| 1-1/8″| 25/1.00| 50/1.00| 50/1.00| 50/0.99| 50/0.99| 38/0.99
1/2″| 1-1/8″| 25/1.00| 50/1.00| 50/1.00| 50/0.99| 50/0.99| 50/0.99
NOTES:
- Do not exceed 150 ft. linear line length.
- Do not exceed 50 ft. vertical separation between indoor and outdoor units.
- 3/4″ vapor line should only be used for 2 ton systems if outdoor unit is below or at same level as indoor unit to assure proper oil return.
- 1-1/8″ vapor line should only be used for 5 ton systems if outdoor unit is below or at same level as indoor unit to assure proper oil return.
- Always use the smallest liquid line allowable to minimize refrigerant charge.
- Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed.
- Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.
Refrigerant Line Size Information (Con’t.)
DESIGNATED TESTED COMBINATION (DTC)
OUTDOOR UNIT| AIR HANDLER| TOTAL CAPACITY BTU/H
[KW]| NET SENSIBLE BTU/H [KW]| NET LATENT BTU/H
[KW]| SEER2| EER2| INDOOR CFM [L/S]| 47 DEGREE
HEATING CAPACITY BTU/H [KW]| 47 DEGREE COP| 17
DEGREE HEATING CAPACITY BTU/H [KW]| 17 DEGREE COP|
REGION IV HSPF2
SP16AZ24AJ3| SH3VZ2417STACN| 22,600| [6.6]| 17,300| [5.1]| 5,300| [1.6]| 16.0|
9.8| 750 [354.0]| 22,800| [6.7]| 3.50| 13,800| [4.0]| 2.40| 8.0
SP16AZ36AJ3| SH3VZ3617STACN| 34,200 [10.0]| 26,200| [7.7]| 8,000| [2.3]| 16.0|
9.8| 1,100 [519.1]| 34,500 [10.1]| 3.20| 21,600| [6.3]| 2.30| 7.5
SP16AZ48AJ3| SH3VZ4821STACN| 45,500 [13.3]| 34,900 [10.2]| 10,600 [3.1]| 16.0|
9.8| 1,475 [696.1]| 45,500 [13.3]| 3.40| 28,500| [8.4]| 2.40| 8.0
SP16AZ60AJ3| SH3VZ6024STACN| 55,000 [16.1]| 42,200 [12.4]| 12,800 [3.8]| 16.0|
9.8| 1,725 [814.1]| 57,000 [16.7]| 3.20| 35,500 [10.4]| 2.40| 8.0
Integrated Controls
EcoNet ® is smart, technology that allows Heating and Cooling, products to communicate with each other on one integrated network.
THE ECONET® SMART THERMOSTAT
BUILT-IN WIFI
4.3″ LCD TOUCH SCREEN
LOCAL WEATHER – Current conditions plus 6-day forecast
5 OPERATING MODES – Heat, Cool, Auto, Emergency Heat and Fan Only
7-DAY PROGRAMMABLE SCHEDULE – Offers comfort without thought
ONE-TOUCH AWAY – Quickly switch to your energy-saving away preferences
VACATION SCHEDULING – Allows you to save while you’re away and come home
to comfort
STANDBY SCREEN – Displays indoor temperature and current weather
OPERATIONAL FEATURES
AUTOMATIC CHANGEOVER – Transitions between heating and cooling
automatically to keep the house comfortable
INTEGRATED WATER CONTROL – Enables easy water heater management
SMOOTH ARRIVAL – Prompts the system to start ahead of schedule to ensure
the home is at the desired temperature at the scheduled time
HUMIDITY CONTROL – Supports humidifier accessories or over-cool based
dehumidification
DETAILED OPERATING STATUS – View pertinent equipment status information
and run times
CONTINUOUS FAN – Offers 5 speeds (Low, Medium Low, Medium, Medium High,
High)
SHORT-CYCLE PROTECTION – Avoids damage to equipment from short run cycles
MONITORING & REMOTE CONTROL FEATURES
ACTIVE MONITORING – Alerts to problems that need immediate attention
REMOTE CONTROL – Allows adjusting of comfort and settings from anywhere
using a mobile device
SERVICE ALERTS – Sends routine maintenance reminders
AIR FILTER MONITORING – Detects when it’s time to replace the air filter
ALARM HISTORY – Displays time-stamped alarm codes with clear descriptions
GENERAL TERMS OF LIMITED WARRANTY*
Fujitsu General America, Inc. will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty.
For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate.
Conditional Unit Replacement
(Registration Required: Ten (10) Years
Parts: Ten (10) Years