UR FOG 200 Dimgenerator Modular Instruction Manual

June 13, 2024
UR FOG

UR-FOG-logo

UR FOG 200 Dim generator Modular

UR-FOG-200-Dim-generator-Modular-product

Product Information

  • The UR Fog Modular fogging systems are advanced devices in the security market, offering great technological innovations.
  • These systems feature a fluid injection system, a disposable bag, an ecological and economic system for complete bag emptying, and a heating system.
  • They are designed to provide optimal performance and are suitable for integration with any existing alarm system.

The key features of the UR Fog Modular fogging systems include:

  • Simple installation
  • Lowest power consumption among fogging systems
  • Use of UR FOG-branded fluids only

Product Usage Instructions

  1. This appliance is not intended for use by individuals with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge unless supervised or instructed by a person responsible for their safety.
  2. Ensure that children are supervised and do not play with the appliance.
  3. Install the fogging system in a way that does not obstruct escape routes.
  4. Verify that the fog does not limit visibility near stairs, landings, or moving objects that may cause falls, injuries, or damage to persons.
  5. In multi-story buildings, ensure that the escape route is not protected by an activated fogging system during maintenance to avoid accidental activation.
  6. Never direct the fog jet towards an object or wall less than 2 meters away. If possible, increase the suggested distance.

Technical Specifications

Model| Weight without Bag| Max Fog Emission in a Single Shot| Total Fog Emission Capacity with Full Bag| Fog Bag Capacity| Working Time without Mains Power| Max Power on Heating System| Average Power Consumption during Heating| Heating Time| Average Power Consumption| Maximum Current Consumption at 12V| Battery Type (not included)| Door Tamper| Anti-Tear Off and Anti-Shift
---|---|---|---|---|---|---|---|---|---|---|---|---|---
MODULAR 200| 7.5 Kg| 200 m3| 850 m3| 1 x 500 ml| About 1 hour| 170 W| 170 W| About 1 hour| 37 W| 1.2 A| Pb 2 Ah 12V| n/a| n/a
MODULAR 300| 8.0 Kg| 300 m3| 900 m3| 1 x 500 ml| About 1 hour| 170 W| 170 W| About 1 hour| 37 W| 1.2 A| Pb 2 Ah 12V| n/a| n/a
MODULAR 400| 8.5 Kg| 400 m3| 1200 m3| 1 x 750 ml| About 1 hour| 280 W| 280 W| About 2 hours| 48 W| 1.8 A| Pb 2 Ah 12V| n/a| n/a
MODULAR 500| 8.5 Kg| 500 m3| 1500 m3| 1 x 750 ml| About 1 hour| 280 W| 280 W| About 2 hours| 48 W| 2 A| Pb 2 Ah 12V| n/a| n/a
MODULAR 800| 9.5 Kg| 800 m3| 2400 m3| 1 x 1000 ml| About 1 hour| 280 W| 280 W| About 2 hours| 48 W| 2.5 A| Pb 2 Ah 12V| n/a| n/a

WARNING!

  • All UR FOG fogging systems should only be used with UR FOG-branded fluids.
  • It is strictly forbidden to use any fluid not previously authorized in writing by UR FOG srl.
  • The conditions of use will be automatically accepted by breaking the security labels on the product.

PACKAGE CONTENT

Inside the package you will find:

  1. A fogging machine Modular 200/300/400/500/800 model
  2. One 500 ml fluid bag (200/300 mod.) – One 750 ml (400/500 mod.) – One 1000 ml (800 mod.)
  3. A warning label to indicate the device’s presence
  4. Installation and use manual

PRODUCT PRESENTATION

Thank you for purchasing a UR Fog product

  • The great technological innovations such as the fluid injection system, the disposable bag, the ecological and economic system for the complete emptying of the bag, together with the heating system, make the Modular fogging systems the best-performing devices in the security market.
  • Simple: The machine is easy to install and able to be integrated into any existing alarm system; they lodge 1 fog fluid bag.
  • Cheap: the lowest power consumption among fogging systems.

CONDITIONS OF USE AND WARNINGS

  • The fog generated by UR Fog does not create problems or injuries to people during a short stay in a room filled with fog if the system is used according to the manufacturer’s recommendations.
  • The generated fog is certified as safe for people and animals by an authorized international certification company and it is proven that it does not leave any residual.
  • UR Fog products are certified respecting European laws and regulations.
  • Any certifications required in specific countries are the responsibility of the distributor of that specific country.
  • The documents related to certifications can be requested by mail to: support@urfog.com.
  • It is not guaranteed that the manufacturer the use the UR Fog system in the presence of objects that may be damaged by contact with substances based on glycol, water, and alcohol.
  • Any employee or worker who may be exposed to fog must be warned in advance and must be checked for any allergy to the substances listed above.
  • At the date of printing of this manual, there has never been any problem related to any allergy.
  • UR Fog is in no way responsible for any damage or condition of use that has not been required and specifically approved by any specific written request prior to the installation of its products.
  • For fog fluid please refer to the UR Fog fluid safety data sheet published on the website and carefully read it at www.urfog.com.
  • Contact a doctor if for any reason you swallow fog fluid or if after contact with eyes or skin, you have any kind of reaction, and in any case wash it immediately with water and soap.
  • Do never stay for a long time in a room filled with fog.
  • Do not use charged bags that are not the ones suggested by UR Fog and never try to recharge them, they are made for a single use.
  • Follow your national rules for the disposal of empty bags.
  • Keep UR Fog bags out of reach of babies and animals.
  • The nozzle may be hot and touching it may cause burns.
  • Do not look directly into the nozzle.
  • Never use UR Fog products for any purpose that is not related to protection from thieves or robbery (the choice of the conditions of use in case of robbery will be suggested by your security consultant).
  • Never use different fog fluids or add any other substance to the bags.
  • Do not use or keep charged UR Fog machines in vehicles and do never transport UR Fog before 24 hours since it has been shut off.
  • During transport, it must be not armed.

INSTALLATION TIPS FOR FOGGING SYSTEMS

Please observe the following instructions for installing UR Fog:

  1. This appliance is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.

  2. Children should be supervised to ensure that they do not play with this appliance.

  3. The machine must be installed avoiding to obstructing escape routes.

  4. Verify the fog does not limit the visibility near stairs, landings, or moving objects that may cause falls, injuries, or any damage to persons.

  5. When using the product in multi-story buildings, if the escape route runs through an area that is protected by a fogging system, it is recommended to install a vocal warning that provides instructions on the behavior to observe.

  6. Do not look directly into the nozzle. Do not add any other substance to the bags.

  7. The nozzle may reach high temperatures, and touching it may cause burns.

  8. When UR Fog produces fog avoid staying closer than 1 meter from the machine.

  9. Before testing UR Fog, remember to report it in advance to the firefighters in your area to avoid false alarms.

  10. Remember to put warning labels about the presence of UR Fog on the windows.

  11. Report its installation to the firefighters in your area and to other institutions if needed.

  12. It is necessary to add an external switch to separate the fog generator from the alarm system and it should be activated before the maintenance to avoid that input tests, for example, can activate the fog generator.

  13. Never direct the fog jet towards an object or a wall less than 2 meters away and if possible increase the suggested minimum distance.
    Thanks to the power of the jet, UR Fog reaches and exceeds more than 10 meters away in the first 3 seconds from the point where the machine is installed.

  14. Setting the shooting time interval between the minimum and maximum shown in the shooting table, avoid “overshooting” even if the produced fog is dry and generally doesn’t leave a residue.

  15. A shot that goes far beyond the recommended seconds can create residue problems in the room.

  16. Install at a height of about 2.5 meters so as not to let it be reached, avoiding possible tampering.

  17. Do not move the machine when it is still hot.

  18. The main body of UR Fog, which has the heating system enclosed inside a metal frame, should not be opened unless by specific and authorized service centers. Do not open and touch the for any reason insulation before 24 hours UR Fog has been shut off. The internal part may reach really high temperature.

  19. Do not activate the UR Fog machine before the installation is completed.

  20. Insert the fluid bag as the last procedure and verify the anti-tampering function.

  21. When the installation is finished, always test the system.

  22. Install UR Fog avoiding any obstacles in front of it which can prevent the spreading of the fog.

  23. The tip of a stranded conductor should not be soft-soldered where the conductor is subjected to contact pressure.

  24. The UR Fog machine should not be exposed to water spray or dripping.

  25. Request to UR Fog or its distributors to take part in courses for installers to ensure the optimal installation of the equipment.

  26. The content of the bags is mechanically predetermined and can be subject to variations +/- 10%

TECHNICAL SPECIFICATIONS AND BATTERY ENDURANCE/BACKUP

***** Industrial standard as from

other manufacturers

Weight without bag

| MODULAR

200

7,5 Kg

| MODULAR

300

8 Kg

| MODULAR

400

8,5 Kg

| MODULAR

500

8,5 Kg

| MODULAR

800

9,5 Kg

---|---|---|---|---|---
Max fog emission in a single shot| 200 m3| 300 m3| 400 m3| 500 m3| 800 m3
Total fog emission capacity with full bag| 850 m3| 900 m3| 1200 m3| 1500 m3| 2400 m3
Fog bag capacity| 1 x 500 ml| 1 x 500 ml| 1 x 750 ml| 1 x 750 ml| 1 x 1000 ml
Working time without mains power| about 1 hour| about 1 hour| about 1 hour| about 1 hour| about 1 hour
Max power on heating system| 170 W| 170 W| 280 W| 280 W| 280 W
Average power consumption during heating| 170 W| 170 W| 280 W| 280 W| 280 W
Heating time| about 1 hour| about 1 hour| about 2 hours| about 2 hours| about 2 hours
Average power consumption| 37 W| 37 W| 48 W| 48 W| 48 W
Maximum current consumption at 12 V| 1,2 A| 1,2 A| 1,8 A| 2 A| 2,5 A
Battery type (not included)| Pb 2 Ah 12V| Pb 2 Ah 12V| Pb 2 Ah 12V| Pb 2 Ah 12V| Pb 2 Ah 12V
Door tamper| n/a| n/a| n/a| n/a| n/a
Anti-tear off and anti-shift| n/a| n/a| n/a| n/a| n/a

  • The “empty” signal shows that the unit is still capable of performing a full shot at full capability.
  • However, it is recommended to always have at disposal a further recharge and to proceed with the substitution as soon as possible.

WARNING:

  • Do not disconnect the machine immediately after the shot
  • Change the battery every two years
  • Change the bag as soon as the “empty” signal appears
  • The generator cannot be activated on a surface that does not allow air circulation from side slots

PREPARATION TO THE INSTALLATION

  • It is always recommended to secure the fog generator to a wall even when it is placed on a flat surface.
  • The optional bracket, mainly recommended for ceiling installation, can also simplify standard installation, by allowing to use of back holes for the passage of cables. An optional orientable module is available for wall mounting.
  • Always verify that the bracket or the support surface is suitable for the weight of the machine.
  • It is suggested not to install the machine behind walls in a limited closed area without specific ventilation, in order to prevent possible overheating.
  • CAUTION to avoid injuries please securely secure the fogging machine to the wall according to the installation instructions.
  • After removing the machine from the package, unscrew the four screws of the front panel. Remove the front panel and uncover the electrical circuit (hereinafter referred to as PCB), the DC12V power supply, the thermal unit, and the fluid bag.

ELECTRICAL POWER SUPPLY

  • The 230V input provides primary power to the heat exchanger and, by the use of a switching power supply, to the electronic board and the pump.
  • The heat exchanger’s working time without mains power ensures proper functioning for a certain period of time, depending on the model, even in the complete absence of mains power.
  • The functioning of the electronic part and the pumping system is guaranteed by the 12V 2A battery (not included).
  • Although the heating element is 180W, the average power consumption is 170W during heating and between 40W and 60W when operating.
  • Do not use inverter or UPS if you are not sure that they generate a pure sine wave, not a rebuilt one.
  • Ask please to the UPS manufacturer the correspondence of such features before proceeding with the connection.
  • The max current to be considered for the system is 2A
  • The connection to the 230V and 110V electricity grid must be performed by a qualified technician.
  • Connect the equipment to the electricity grid only after you have completed the installation.
  • It is necessary to connect the ground terminal.
  • The system must be connected to the mains through an automatic switch (automatic switch, curie C, with Ih= 10 A and Idif= 30 mA,…) with breaching capacity based on the assumed fault current of the fogging system in the sampling point.
  • PLEASE NOTE THAT, AS ALL POWERED EQUIPMENT FROM THE ELECTRICITY GRID REQUIRING INSTALLATION, IT IS SUBJECT TO COMPLIANCE WITH RULES OF THE COUNTRY IN WHICH IT IS INSTALLED (D.M. 37 January 22, 2008)
  • IF YOU NEED TO REPLACE THE FUSE, USE ONLY FUSE WITH THE FOLLOWING SPECIFICATIONS:
  • Timed Fuse 250v H Type (1500A) CERAMIC BODY FILLED WITH QUARTZ, REF. STD. EN60127-2-3/DIN41660 3,15AH (EXAMPLE OMEGA GT520231)
  • While connecting the machine to the mains power, it is recommended to pay attention to the connection and the screwing of the terminal block screws.
  • The fact of disconnecting or modifying the ground cable voids the warranty and can cause troubles or accidents related to the temperature control.

POWER SUPPLY CONNECTION

  1. 12V Power supply connection
  2. 230V Power supply connection
  3. 230V Mains power
  4. Ground connection
  5. Battery slot (battery not included)
  • The battery is essential for the safe use of the device, it is recharged by the board’s circuitry
  • The predisposition 2A 12V lead-acid battery is lodged below the exchanger
  • To gain access to the battery slot it is necessary to remove the plastic front panel and possibly stop the screw.

DESCRIPTION OF INPUT AND OUTPUT CONNECTIONS

Connection PIN description

DC12V Power supply OUTPUT

  1. + DC 12V Output (max 300 mA)
  2. 0V DC ground connected OUTPUTS
  3. READY OC – temperature reached
  4. ARM OC – ready to shoot
  5. EMPTY/FAULT OC – empty bag/faulty unit INPUTS
  6. GND
  7. ARM Arming input
  8. TRIG Shooting input

Note: both commands are contacts that close to GND

OUTPUT Power DC12 V

  1. Output DC12v (max 300mA) for electrical connection of local devices connected to the board.
  2. It can be used to power a local PIR or a remote receiver. It is recommended not to overload the output OUTPUTS
  3. READY Unit has reached the correct temperature, and full-time shooting is possible.
  4. ARM Unit is armed and ready to shoot.
  5. EMPTY/FAULT
    • EMPTY This Output (NPN Open Collector) closes towards negative when the bag is empty or in reserve.
    • The empty bag signal is eliminated only by performing the RESET. The RESET MUST be performed at each bag change.
    • FAULT This Output (NPN Open Collector) closes towards negative when a fault condition that voids functionality occurs.
    • It also activates when maintenance is needed, eg. empty batteries or wrong detections on the power supply or temperature sensor. If a power fault occurs it will be self resetted when the mains power is back.
    • We remind you that it is FUNDAMENTAL to connect this output to an alarm control panel or other equipment able to forward the signal to whoever is concerned. INPUTS
  6. GND Reference GND for the inputs.
  7. ARM Closing the contact ARM: the blue LED turns ON and then, if the unit has reached the correct temperature, it is ready to generate fog. During the shot, if the contact ARM is opened, it immediately stops fog generation.
  8. TRIG Closing the contact TRIG, f the unit is armed and has reached the correct temperature, it produced fog for the time set.
  • After the shot, all further shot commands within 120 seconds will not be processed.
  • In order to avoid accidental activations with consequent fog emission, the inputs are in “negative safety.
  • so the disconnection of a wire does not cause their activation.
  • It is essential to carefully check the reliability of the connections and protect the cables to the alarm control unit where there is a risk of accidental or malicious damage.
  • A) J4 Mains power connection
  • B) J5 Heater Resistor
  • C) J2 Fuse Cable
  • D ) J7 Power supply unit 12v
  • E) J9 Battery 12v 2A connector
  • F ) J8 Thermal Sensor connector
  • G ) J10 Inputs/Outputs connector
  • H ) J11 RS232 connector
  • I ) J3 (J6) FogStorm Pump Connector
  • L ) J1 USB port
  • M ) F4 Mains fuse
  • W1 Shooting time setting enable
  • W2 Reserved (Open)
  • W3 Reserved (Closed)

CONNECTION EXAMPLES

  • The diagrams and examples below are intended only for a “better understanding” of the operation of the inputs / outputs. None of the diagrams below represents the “single scheme to perform” as, in respect of the reference standard EN50131-8, there are precise indications and only using all inputs and outputs on the PCB it is possible to abide by the standard.
  • Is recommended to use the “HOLD-UP” function after a careful evaluation of the risks from a security consultant.
  • When FAST Modular is ARMED , it becomes immediatly ready to create fog.For safety reasons and to avoid false fog emissions is suggested to program the allarm panel to allow enough time to leave the place.
  • The ON/OFF output of this alarm panel is an Open Collector NPN that is OPEN with the alarm OFF and close to negative for all the time the alarm panel is active and monitoring.
  • The alarm panel output is normally open and close the contact during alarm time.
  • A FAST MODULAR inputs connected to standard alarm panel outputs
  • B FAST MODULAR inputs connected with a clean contact ( relays) alarm panel outputs
  • C Wiring example of FAST MODULAR outputs to drive leds and/or relays

A – FAST MODULAR inputs connected to standard alarm panel outputsUR-
FOG-200-Dim-generator-Modular-fig-7

  • The ON/OFF output of this alarm panel is an Open Collector NPN that is OPEN with the alarm OFF and close to negative for all the time the alarm panel is active and monitoring.
  • The alarm panel output is normally open and close the contact during alarm time.
  • B – FAST MODULAR inputs connected with a clean contact ( relays) alarm panel outputsUR-FOG-200-Dim-generator-Modular-fig-8
  • The ON/OFF output of this alarm panel is an open relay when the panel is OFF that continuously keeps closed for all the time the alarm panel is monitoring.
  • The alarm output of the panel is an open really that closes when an alarm condition is detected.

C – Wiring example of FAST MODULAR outputs to drive leds and/or relaysUR-
FOG-200-Dim-generator-Modular-fig-9

SHOOTING TIME SETTING AND FOG FLOW DIRECTION

  • To set the shooting time, after opening the front panell, you must close the jumper W1 in SET position as shown in figure, then, holding down the button S1 “RESET”, the green led on the front will flash and each flash is equivalent to one second.
  • If you press the button again, the shooting time is not added to the one previously set, but will restart from zero.
  • Notice: each blink equals 1 second.
  • If RESET button is keeped pressed for a time longer than the shoting time allowed for the unit, shooting time will be
  • set to the maximum.
  • Shooting time can be set according to desired seconds, but to correclty activate the bag reserve in full security, it must be set minimun 4 seconds of shooting

RECOMMENDED SHOOTING SECONDS ACCORDING TO THE VOLUME SPACE TO PROTECT (m3)

  • Fogging systems FAST Modular are able to produce fog based on second by second setting.
  • The maximum quantity of 5,6 ml/s (FAST Modular 200) and 11,3 ml/s (FAST Modular 800) allows to fill an area of about 200 and 800 m3.
  • There might be cases in which, due to specific characteristic of the location, nozzle type, levels of temperature and air pressure, degree of the fog density and light in the target area, the shooting time can be increased or decreased.
  • For example, above 5mt of height the shooting time must be integrated and above 7mt, every additional meter should be considered as double.

(HxLxP) x D x V x R x I

  • HxLxP ——– Height x Width x Depth of the area to protect
  • D ————- Density of the produced fog
  • V ————- Temperature and air pressure
  • R ————- Acceptable residue in case of saturation of V parameter
  • I ————– Intensity of the surface light
  • The following tables indicate the suggested fog emission in relation to the number of seconds of shooting set in average condition of temperature, air pressure and humidity.
  • To correctly dimension the machines it is needed to verify that the saturation of the area occurs in faster time than the one supposed for the theft.

SHOOTING TABLE MODULAR 200 (max 28 sec.)

to protect

25 (75*)

| Seconds

of emission

4

|

to protect

75 (225*)

| Seconds

of emission

11

|

to protect

150 (450*)

| Seconds

of emission

21

---|---|---|---|---|---
50 (150)| 7| 100 (300)| 14| 200 (600*)| 28

SHOOTING TABLE MODULAR 300 (max 40 sec.)

to protect

50 (150*)

| Seconds

of emission

7

|

to protect

150 (450*)

| Seconds

of emission

21

|

to protect

300 (900*)

| Seconds

of emission

40

---|---|---|---|---|---
75 (225)| 9| 200 (600)| 28| |
100 (300)| 14| 250 (750)| 35| |

SHOOTING TABLE MODULAR 400 (max 46 sec.)

to protect

50 (150*)

| Seconds

of emission

6

|

to protect

150 (450*)

| Seconds

of emission

21

|

to protect

300 (900*)

| Seconds

of emission

40

---|---|---|---|---|---
75 (225)| 9| 200 (600)| 23| 400 (1200)| 46
100 (300
)| 12| 250 (750*)| 35| |

SHOOTING TABLE MODULAR 500 (max 48 sec.)

to protect

50 (150*)

| Seconds

of emission

6

|

to protect

150 (450*)

| Seconds

of emission

16

|

to protect

300 (900*)

| Seconds

of emission

27

---|---|---|---|---|---
75 (225)| 9| 200 (600)| 21| 400 (1200)| 37
100 (300
)| 12| 250 (750)| 24| 500 (1500)| 48

SHOOTING TABLE MODULAR 800 (max 69 sec.)

to protect

50 (150*)

| Seconds

of emission

5

|

to protect

200 (600*)

| Seconds

of emission

19

|

to protect

500 (1500*)

| Seconds

of emission

43

---|---|---|---|---|---
75 (225)| 8| 250 (750)| 22| 600 (1800)| 51
100 (300
)| 10| 300 (900)| 26| 700 (2100)| 60
150 (450)| 14| 400 (1200)| 35| 800 (2400*)| 69

Industrial standards as from other manufacturers

The value in the first column indicates the volume of the room to be protected, with respective seconds of emission reported in the second column. The value in m³ varies depending on the density to be obtained. With the suggested value it is possible to get the maximum density recommended to ensure the absence of any residual. In places where a little residual causes no problems, it is possible to increase the shooting time. Please note that the more fog is released, the more time is required to recover visibility. High levels of fog, over recommended limits, can leave residual. Any residue usually goes away by itself within 24/48 hours, otherwise, being soluble in water, it is enough to use a wet cloth for cleaning. If you desire to obtain an average of 1-meter visibility after 60 seconds, as specified by the standard EN 50131-8, as used as a reference by all manufacturers of Fog generators, the number of shooting seconds it is to be reduced in half.

INSTALLATION, EXCHANGE AND BAG RESET

  • Insert the bag in place as show in picture.
  • Insert a new bag and push metal connector till a “click” is heard.UR-FOG-200-Dim-generator-Modular-fig-13

FRONT LEDS MEANING

RED LED (right)

  • ON: Error (Empty bag or low fluid, Mains power off/Battery low) or Fault
  • OFF: No error condition.

BLU LED (center)

  • ON: The unit is armed and ready to shoot (with green led ON).
  • OFF: Unit is disarmed, shot is not possible.

GREEN LED (left)

  • ON: The unit has reached the correct temperature.
  • OFF: The unit is warming, no shot possible.
  • The EMPTY signal also means that fluid is going LOW.
  • It means that the unit has shot at least 100 seconds since the last reset (Modular 200).
  • The central RED low-power light means the unit is powered on.
  • The RED FAULT LED is on the top of the board.

MAINTENANCE

UR FOG fogging systems don’t need special maintenance, nevertheless is suggested a periodical check to the following parts by skilled operators:

  1. Verify battery and power supply status.
  2. Verify screws are firmly closed.
  3. Verify the output nozzle is not damaged and without anything inside.
  4. Verify the pneumatic circuit.
  5. Verify once a year liquid pump

BATTERY AND POWER SUPPLY CHECK

  • Verify that the output of the power supply without any load (battery unplugged ) is 14,1 V on the PSU and 13,8 V on the FASTON battery connectors. If a different value is noticed, set the trimmer on the power supply.
  • Verify battery status (integrity check, no overheating); is suggested to replace the battery on 2 2-year base due to the heavy load during shots without mains power.

SCREWS

  • Verify that all fixing screws are correctly set and eventually re-screw them.

OUTPUT NOZZLE

  • Verify that the output nozzle is not damaged and that there is nothing inside blocking the fog ejection flow.

YEARLY PUMP FUNCTIONALITY TEST

  • The test is done by executing a trial shot on the unit. To avoid creating too much fog during the test is suggested to stop the flow after a few seconds dearming the unit under test. The fog flow will immediately stop.

RESET FROM FAULT CONDITION

  • Disconnect the units from any power source, both mains power and battery must be disconnected. Wait 15 minutes and reconnect the battery and mains power.
    This procedure helps to understand if the fault condition was due to mains power overload, serious power supply problems, or problems in the thermal loop.

  • The fault condition is shown by the RED LED ON (LED DL4 on the top), the output FAULT immediately switches and can indicate a transient or fixable condition (Eg. low battery power or no mains power), or a problem that cannot be fixed on-site.

  • WARNING: The RED LED (LED DL1, middle of the board), means that the unit is ON. It is NOT a fault condition.

  • On mains power fault or battery low conditions, the unit will recover itself without any further operation on it.

  • In the event that the mains power fault has generated further problems to the unit (Eg. board fuse) or that the backup battery is not working anymore, maintenance is needed.

DEFECTS POSSIBLE SOLUTION

DEFECT FOUND POSSIBLE CAUSE POSSIBLE SOLUTION
Small fog flow coming out from the nozzle All products are 100% and a small
amount of liquid could be still in the warming unit This condition is normal

and can happen on the first installation, it will completely disappear in a while when the unit becomes completely hot.
|

Check power input DC12v

|

Verify the output from the power supply (see paragrph 14)

RED Led ON (Error)

| Too low battery level or exhaust| Replace Battery
Bag in Reserve or Empty| Replace fluid Bag

No Mains power

|

Check mains power or F4 fuse

RED Led ON (Fault)

| Disturbance/interference or potential differences between devices| In the event of high noise on mains power (lighting) an error while reading thermocouple values can occur.

Execute recovery (Paragraph 16).

If even recovery fails the unit may be faulty

In very large installations or with more than one fog unit connected to the same alarm panel,

a mains power difference can occur,

in that event the units have to be decoupled

Error in the thermal loop

|

Error on thermocouple, fuse cable, resistor. Please refer to the technical service

Heater Temperature too high or thermocouple error| Switch off the unit and verify the screw on the J8 connector

Poor ventilation

|

Switch off the unit and clean the air holes

DEFECT FOUND POSSIBLE CAUSE POSSIBLE SOLUTION

Unit ARMED (BLUE LED ON)

but don’t execute trig command

| Red front led ON| The bag changed, reset is needed Follow the instructions in Paragraph 13
Empty bag- replace it following the instructions in Paragraph 13
Green front LED is OFF| The unit still warming, wait max 120min. with the unit connected to the mains power
Wires error| Verify on J10 that when the alarm is ON there is a contact between – GND(6) + TRIG(8)
Mains power overload| Try the Recover procedure(Paragraph 16) With no results replace the board
Electronic Board overheat| Clean air flow holes (Paragraph14)
The unit cannot be ARMED BLU LED OFF| Wires error| Verify on J10 that when the alarm is active there is a contract between – GND(6) + ARM(7)
While setting the shooting time the green LED lights once| The W1 jumper is OPEN, unit in’ “RESET” mode|

Refer to bag Reset (Paragraph12)

and shooting time setting (Paragraph 11)

Warning:

please verify/set again the shooting time.

See time setting (Paragraph 11)

WARRANTY

  • The warranty of UR Fog is two years and is handled directly by the dealer or authorized installer, so please contact your supplier to take advantage of the warranty with a copy of the purchase document that contains the serial number of the machine.
  • Not included in the warranty: moving parts and/or damages depending on the incorrect use unless it is found a manufacturing defect in origin. Liquid and bags are not covered by warranty.
  • BY BREAKING THE SECURITY LABELS AND THE OPENING OF THE MACHINE YOU WILL ACCEPT WHAT IS WRITTEN ON THIS MANUAL AND  ON THE WEB SITE: www.urfog.com
  • We recommend throwing away the batteries in the appropriate waste containers for recycling. Heavy metals contained in them are recyclable.
  • UR Fog srl: Via Toscana n. 38 – 10099 San Mauro Torinese – Italy Phone +39 011/01.33.037 – Fax 011/01.33.005 support@urfog.com
  • Legal office: Via Giacinto Collegno 11 – 10143 – Torino – Italy
  • RESELLER/INSTALLER STAMP (company to contact for the warranty)
  • Serial number Date of installation Signature of the installer
  • At the end of the installation, write down the identification number of the machines, and the date of the installation and sign in the dedicated spaces.
DATE BATTERY EXCHANGE BAG EXCHANGE SIGNATURE
YES NO YES NO
YES NO YES NO
YES NO YES NO
YES NO YES NO
YES NO YES NO
YES NO YES NO
YES NO YES NO
YES NO YES NO
YES NO YES NO
YES NO YES NO
YES NO YES NO
YES NO YES NO
YES NO YES NO
YES NO YES NO
YES NO YES NO
YES NO YES NO
YES NO YES NO

It is mandatory to fill out this table in accordance with the security rules UR-FOG-200-Dim-generator-Modular-fig-17

  • N.B. Ask for the PDF module by writing to:support@urfog.com
  • TO USE UR FOG FOGGING SYSTEMS WITH PURIFOG/PURIFOG HYPO FLUIDS FOLLOW THE DATASHEETS INSTRUCTIONS AVAILABLE FOR DOWNLOAD ONWWW.PURIFOG.COM
  • UR Fog S.r.l. Via Toscana 38 – 10099 San Mauro Torinese – Italy

Documents / Resources

| UR FOG 200 Dimgenerator Modular [pdf] Instruction Manual
200 Dimgenerator Modular, 200, Dimgenerator Modular, Modular
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals