UR FOG 390 Compact Security Fog System User Manual
- May 15, 2024
- UR FOG
Table of Contents
- PACKAGE CONTENT
- PRODUCT PRESENTATION
- CONDITIONS OF USE AND WARNINGS
- INSTALLATION TIPS FOR FOGGING SYSTEMS
- TECHNICAL SPECIFICATIONS
- INSTALLATION
- ELECTRICAL POWER SUPPLY
- POWER SUPPLY CONNECTION
- DESCRIPTION OF INPUT AND OUTPUT CONNECTIONS
- CONNECTION EXAMPLES
- SHOOTING TIME SETTING AND FOG FLOW DIRECTION
- INSTALLATION, EXCHANGE AND BAG RESET
- FRONT LEDS MEANING
- MAINTENANCE
- RESET FROM FAULT CONDITION
- DEFECTS POSSIBLE SOLUTION
- WARRANTY
- MAINTENANCE
- CUSTOMERS SUPPORT
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
UR FOG 390 Compact Security Fog System
WARNING!
All UR FOG fogging systems should only be used with UR FOG-branded fluids.
It is strictly forbidden to use any fluid not previously authorized in writing
by UR FOG srl.
The conditions of use will be automatically accepted by breaking the security labels on the product.
PACKAGE CONTENT
Inside the package you will find:
- A fogging machine COMPACT 390 model
- One 500 ml fluid bag (also shipped in separate cartoon)
- A window sticker to indicate the device installation
- Installation and use manual
PRODUCT PRESENTATION
Thank you for purchasing a UR FOG product
The great technological innovations such as the fluid injection system, the disposable bag, the ecological and economic system for the complete emptying of the bag, together with the heating system, make the COMPACT fogging systems the best performing devices in the security market.
- Simple: machine easy to install and able to be integrated to any existing alarm system.
- Small: the COMPACT size of the unit allows installation in any places.
- Green: the lowest power consumption among fogging systems .Ready to generate fog in minutes.
CONDITIONS OF USE AND WARNINGS
The fog generated by UR FOG COMPACT does not create problems or injuries to
people during a short stay in a room filled with fog, if the system is used
according to the manufacturer’s recommendations.
The generated fog is certified as safe for people and animals from an
authorized international certification body and it is proven that it does not
leave any residual.
UR FOG COMPACT unit , as the fluid used to generate fog , is certified
respecting European laws and regulations.
Any certifications required in specific countries are a responsibility of the
distributor of that specific country.
The documents related to certifications are available on request by mail to:
support@urfog.com.
It is not guaranteed by the manufacturer the use of UR FOG system in the
presence of objects that may be damaged anyway by the contact with substances
based on glycol, water and alcohol.
Any employee or worker that may be exposed to fog must be warned in advance
and must be checked for any allergy to the substances listed above.
At the date of printing of this manual it has never been pointed out any
problem related to any allergy.
UR FOG is in no way responsible for any damage or condition of use that has
not been required and specifically approved by any specific written request
prior to the installation of its products.
For fog fluid please refer to UR FOG fluid safety data sheet published on the
website and carefully read it at www.urfog.com.
Contact a doctor if for any reason you swallow fog fluid or if after contact
with eyes or skin you have any kind of reaction, and in any case wash it
immediately with water and soap.
Do never stay for a long time in a room filled with fog.
Do not use charged bags that are not the ones suggested by UR FOG and never
try to recharge them, they are made for a single use.
Follow your national rules for the dispose of empty bags. Keep UR FOG bags out
of reach of babies and animals.
The nozzle may be hot and touching it may cause burns. Do not look directly
into the nozzle.
Never use UR FOG products for any purpose that is not related to protection
from thief or robbery (the choice of the conditions of use in case of robbery
will be suggested by your security consultant). Never use different fog fluids
or add any other substance into the bags.
Do not use or keep charged UR FOG machines in vehicles and do never transport
UR FOG before 24 hours since it has been shut off.
During transport the device must be switched off.
INSTALLATION TIPS FOR FOGGING SYSTEMS
Please observe the following instructions for installing UR FOG COMPACT:
-
This appliance is not intended for use by person (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
-
Children should be supervised to ensure that they do not play with this appliance.
-
The machine must be installed avoiding to obstruct escape routes.
-
Verify the fog does not limit the visibility near: stairs, landings, moving objects that may cause falls, injuries or any damage to persons.
-
When using the product in multi-storey buildings, if the escape route runs through an area which is protected by a fogging system, it is recommended to install a vocal warning that provides instructions on the behavior to observe.
-
Do not look directly into the nozzle. Do not add any other substance into the bags.
-
The nozzle may reach high temperatures, touch it may cause burns.
-
When UR FOG COMPACT 390 generates fog avoid staying closer than 1 meter from the device.
-
Report its installation to the firefighters in your area and to other institutions if needed. It is suggested to do it before testing the unit to avoid false alarms.
-
Remember to put windows sticker(s) reporting the presence of UR FOG on the entrance.
-
It is necessary to add an external switch to separate the fog generator from the alarm system and it should be activated before the maintenance to avoid that, for example, maintenance tests can activate the fog generator.
-
Never direct the fog flow towards an object or a wall less than 2 meters away.
-
Before setting installation, consider that COMPACT 390 may reaches and exceeds more than 10 meters away in the first 3 seconds from the point where the machine is installed.
-
Setting the shooting time interval between the minimum and maximum shown in the shooting table, avoid “overshooting” even if the produced fog is dry and generally doesn’t leave residue.
A shot that goes far beyond the recommended seconds can create a residue or even drops in the room. -
Install at an height of about 2,5 meters not to let it be reached, avoiding possible tampering.
-
Do not move the machine when it is still hot.
-
The main body of COMPACT 390, which has the heating system enclosed inside a metal frame, should not be opened unless by specific and authorized service centers. Do not open and touch for any reason the insulation before 24 hours the unit has been shut off. The internal part may still be at very high temperature.
-
Do not activate the COMPACT 390 fogging system before the installation is completed.
-
Insert the fluid bag as the last procedure and remember to verify the anti-tampering functions, if any.
-
When the installation is finished, always perform a trial shot to test the system.
-
Install COMPACT 390 on a wall or desk stand avoiding any obstacles in front of it which can prevent the spreading of the fog.
-
Wiring unit to mains power, remember that the tip of a stranded conductor should not be soft-soldered where the conductor is subjected to contact pressure.
-
The COMPACT 390 fogging system should not be exposed to water spray or dripping.
The unit is designed for indoor use. -
The content of the bags is mechanically predetermined and can be subject to variations +/- 10%.
TECHNICAL SPECIFICATIONS
- Industrial standard as from other manufacturers
COMPACT 390
Weight without bag | 3,8 Kg |
---|---|
Max fog emission in a single shot | 130 m3 (visibility < 1 m) |
Total fog emission capacity with full bag | Around 850 m3 |
Fog bag capacity | 1 x 500 ml |
Working time without mains power | Around 1 hour |
Max power on heating system | 300 W |
Average power consumption during heating | 300 W |
Heating time | Around 20 minutes |
Average power consumption | 32 W |
Maximum current consumption at 12 V | 1,2 A |
Battery type (not included) | Pb 1.2 Ah 12V |
Door tamper | n/a |
Anti-tear off and anti-shift | n/a |
WARNING:
- Do not disconnect the machine immediately after the shot
- Change the battery every two years
- Change the bag as soon as the “empty” signal appears
- The generator cannot be activated on a surface that does not allow air circulation from side slots
The red led ON related with the “empty” signal shows that the unit needs to be
refilled, even if fluid for a
full shot is still available.
It is recommended to always have available a new refill and to proceed to
replace it as soon as possible.
INSTALLATION
It is always recommended to secure the fog generator to a wall even when it is placed on a flat surface.
The optional mounting kit for COMPACT 390, mainly recommended for ceiling installation, include both battery and fluid bag holders. An optional orientable (pan & tilt) module is available for wall mounting, it can also simplify standard installation by allowing to use back holes for the passage of cables.
Always verify that the bracket or the support surface are suitable for the weight of the machine.
It is suggested not to install the machine behind walls in a limited closed area without a specific ventilation, in order to prevent a possible overheating .Always verify that for Compact 390 ceiling/horizontal installation the temperature of the rooms doesn’t exceed 40°C. To avoid injuries please securely fix the fogging machine to the wall according to the installation instructions.
After removing the machine from the package, unscrew the side four screws of the plastic front panel. Remove the front panel and uncover the electrical circuit (hereinafter referred to as PCB), the DC12V power supply, the thermal unit and the fluid bag. (Fluid bag can also be shipped outside the unit).
ELECTRICAL POWER SUPPLY
The 230V input provides primary power to the heat exchanger and, by the use of a switching power supply, to the electronic board and the pump. The heat exchanger’s working time without mains power ensures proper functioning for a certain period of time, usually around one hour, even in complete absence of mains power.
The functioning of the electronic part and the pneumatic system is guaranteed
by the 12V 1.2A battery (not included).
Although the heating element is of 300W, the average power consumption is
between 30W and 50W on normal operation.
Do not use inverter or UPS if you are not sure that are designed to generate a pure sine wave. Square wave or rebuilt sine wave are not suitable for the device. Please ask to the UPS manufacturer the correspondence of such feature before proceeding with mains power connection.
- The max current to be considered for the device is 2A
- The connection to the 230V or 110V electricity grid must be performed by a qualified technician.
- Connect the equipment to the electricity grid only after installation is completed.
- It is necessary to connect the ground terminal.
- The system must be connected to the mains through an automatic switch (automatic switch, curie C, with Ih= 10 A and Idif= 30 mA,…) with breaching capacity based on the assumed fault current of the fogging system in the sampling point.
PLEASE NOTE THAT, AS ALL POWERED EQUIPMENT FROM THE ELECTRICITY GRID
REQUIRING INSTALLATION,
IT IS SUBJECT TO COMPLIANCE WITH RULES OF THE COUNTRY IN WHICH IT IS
INSTALLED
IF FOR ANY EVENIENCE IT IS NEEDED TO REPLACE THE FUSE, USE ONLY FUSE WITH THE SAME SPECIFICATIONS AS THE ONE INSTALLED.
EXAMPLE FOR 120v/230v Model: Timed Fuse 250v H Type (1500A) CERAMIC BODY FILLED WITH QUARTZ, REF. STD. EN60127-2-3/DIN41660 6,3AH (EXAMPLE OMEGA GT520263)
While connecting the machine to the mains power, it is recommended to
carefully care the connections and the screwing of the terminal block screws.
Disconnecting or modifying the ground cable voids the warranty and can
generate faults related to the temperature control.
Note: always check the unit AC voltage is
corresponding to the mains power available in your country.
Different models are available for 120v AC and 230v AC mains power.
NEVER connect the unit to mains power if voltage doesn’t match.
While connecting the machine to the mains power, it is recommended to
carefully care the connections and the screwing of the terminal block screws.
Disconnecting or modifying the ground cable voids the warranty and can
generate faults related to the temperature control.
Note: always check the unit AC voltage is corresponding to the mains
power available in your country.
Different models are available for 120v AC and 230v AC mains power.
NEVER connect the unit to mains power if voltage doesn’t match.
POWER SUPPLY CONNECTION
-
12V Power supply connection
-
230V Power supply connection
-
230V Mains power
-
Ground connection
-
Battery slot (battery not included)
- The battery installation is essential for the safe use of the device, it is monitored and recharged by the board’s circuit.
- The housing for the 1.2A 12V lead-acid battery is lodged on right side of the exchanger.
- To gain access to the battery it is necessary to remove the plastic front panel and metal side battery holder screws (horizontal ceiling installation).
DESCRIPTION OF INPUT AND OUTPUT CONNECTIONS
Connection PIN description
DC12V Power supply OUTPUT
-
+ DC 12V Output (max 200 mA)
-
– 0V DC ground connected
OUTPUTS -
ARD / SHP
-
EMPTY
-
ERROR
INPUTS -
– GND
-
ARM Arming input
-
TRIG Shooting input
Note: both inputs accept dry contacts toward GND.
OUTPUT Power DC12 V
1-2 Output DC12v (max 200mA) for electrical connection of local devices
connected to the board.
It can be used to power a local PIR or a remote receiver. It is recommended
not to overload the output.
OUTPUTS
3 ARD/SHP – Reports the ARMING status (W2 open), or is active when TRIG is in
progress (W2 close).
4 EMPTY – reports the fluid EMPTY condition.
5 ERROR – reports a transient error or fault condition that voids
functionality.
It also activated when maintenance is needed, eg. faulty battery , mains power
fault or detected temperature out of range.
If a mains power fault occurs it will be self resetted when correct mains
power is back. We remind that it is necessary to connect this output to an
alarm control panel or other equipment able to forward the signal to whom is
concerned.
INPUTS
6 GND Reference GND for the inputs.
7 ARM Closing the contact ARM: the blue led turns ON and then, if the unit has
reached the correct temperature, ready to generate fog. During the shot, if
the contact ARM is opened, it immediatly stops fog generation.
8 TRIG Closing the contact TRIG, if the unit is armed and has reached the
correct temperature, it generates fog for the time set.
After the shot, all further shot commands within 120 seconds will not be
processed.
In order to avoid accidental activations with consequent fog emission, the
inputs are in “negative safety”, so the disconnection of a wire does not cause
their activation.
It is essential to carefully check the reliability of the connections and
protect the cables to the alarm control unit where there is a risk of
accidental or malicious damage.
- A) J4 Mains power connection
- B) J5 Heater Resistor
- C) J2 Thermal Cut Off
- D) J7 Power supply unit 230v AC/12v DC
- E) J9 Battery 12v 1.2A connector
- F) J8 Thermal Sensor connector
- G) J10 Inputs/Outputs connector
- H) J11 RS232 port 1 connector
- I) J6 RS232 port 2 connector
- J) J3 Fluid Pump Connector
- L) J1 USB port
- M) F4 Mains fuse
- W1 Shooting time setting enable
- W2 Reserved (Open)
- W3 Reserved (Open)
CONNECTION EXAMPLES
The diagrams and examples below are intended only for a “better
understanding” of the operation of the inputs / outputs. None of the diagrams
below represents the “single scheme to perform” as, in respect of the
reference standard EN50131-8:2019, there are precise indications and only
using all inputs and outputs on the PCB it is possible to abide by the
standard.
Is recommended to use the “HOLD-UP” function after a careful evaluation of
the risks from a security consultant.
When COMPACT is ARMED, it becomes immediately ready to create fog. For safety reasons and to avoid false fog emissions is suggested to program the alarm panel to allow enough time to leave the place.
A COMPACT inputs connected to standard alarm panel outputs
B COMPACT inputs connected with a clean contact (relays) alarm panel
outputs
C Wiring example of COMPACT outputs to drive leds and/or relays
Note: in the following examples the output signal ARD/SHP has the following meaning depending on jumper W2:
W2 OPENED=ARM STATUS reported
W2 CLOSED=SHOT in PROGRESS STATUS reported
A – COMPACT inputs connected to standard alarm panel outputs
The ON/OFF output of this alarm panel is an Open Collector NPN that is OPEN
with the alarm OFF and close to negative for all the time the alarm panel is
active and monitoring.
The alarm panel output is normally open and close the contact during alarm
time.
B – COMPACT inputs connected with a clean contact (relays) alarm panel outputs
The ON/OFF output of this alarm panel is an open relay when panel is OFF that
continuously keep close for all the time the alarm panel is monitoring.
The alarm output of the panel is an open relay that close when alarm condition
is detected.
C – Wiring example of COMPACT outputs to drive leds and/or relays
SHOOTING TIME SETTING AND FOG FLOW DIRECTION
To set the shooting time, after opening the front panel, you must CLOSE the
jumper W1 in SET position then, holding down the button S1, the 3 leds on the
front will flash and each flash is equivalent to one second fog emission.
If you press the button again, the shooting time is not added to the one
previously set, but will restart from zero.
If S1 button is pressed for a time longer than the shooting time allowed for
the unit, shooting time will be set to the maximum possible. Shooting time can
be set according to desired seconds, but to correctly activate pipes refill in
full security, it must be set to minimum 2 seconds. After setting the shooting
time, to avoid wrong time settings, is suggested to keep the W1 jumper OPENed.
In order to select the needed notification, customer can personalize the
output signal as follow:
W2 OPENED = ARM STATUS – ACTIVE unit is armed – OFF unit not armed
(DEFAULT).
W2 CLOSED = SHOT STATUS – ACTIVE unit is performing a shot – OFF no shot
in progress.
On the UR FOG Compact 390 mainboard are present two serial ports connectors
(J11 and J6) that are reserved for connection to expansion modules and
communication devices specially designed by the manufacturer.
To allow advanced diagnostics, it is possible to connect a personal computer
with Microsoft Windows or Linux operating system using a micro USB cable to
the J1 port. Using a generic terminal emulator it will be possible to display
the operating parameters of the device on the screen. The same port can be
used for any firmware updates of the device. We recommend that you refer to
your product distributor for more information about advanced diagnostic.
RECOMMENDED SHOOTING SECONDS ACCORDING TO THE VOLUME SPACE TO PROTECT (m3
Fogging systems COMPACT 390 is able to produce fog based on second by second
setting.
The maximum quantity of 1,5 ml/s allows to fill an area of about 150 cubic
meters.
There might be cases in which, due to specific characteristic of the location,
nozzle type, levels of temperature and air pressure, degree of the fog density
and light in the target area, the shooting time can be increased or decreased.
For example, above 3mt of height the shooting time must be integrated and
above 5mt, every additional meter should be considered as double.
HxLxP) x D x V x R x I
HxLxP——– Height x Width x Depth of the area to protect
D————- Density of the produced fog
V————- Temperature and air pressure
R————- Acceptable residue in case of saturation of V parameter
I————– Intensity of the surface light
The following tables indicate the suggested fog emission in relation to the
number of seconds of shooting set in average condition of temperature, air
pressure and humidity.
To correctly dimension the machines it is needed to verify that the saturation
of the area occurs in faster time than the one supposed for the theft.
SHOOTING TABLE COMPACT 390 (max 50 sec.)
m³ to protect 13 (39)| Seconds of emission 5| m³ to
protect 65 (195)| Seconds of emission 25| m³ to protect
117 (351)| Seconds of emission 45
---|---|---|---|---|---
26 (78)| 10| 78 (234)| 30| 130 (390)| 50
39 (117)| 15| 91 (273| 35| |
52 (156)| 20| 104 (312)| 40| |
- Industrial standard as from other manufacturers
The value in the first column indicates the volume of the room to be protected, with respective seconds of emission reported in the second column. The value in m³ varies depending on the density to be obtained. With the suggested value it is possible to get the maximum density recommended to ensure the absence of any residual. In places where a little residual causes no problems, it is possible to increase the shooting time. Please note that the more fog released, the more the time required to recover visibility. High levels of fog, over recommended limits, can leave residual. Any residue usually goes away by itself within 24/48 hours, otherwise, being soluble in water, it is enough to use a wet cloth for cleaning. If you desire to obtain an average of 1 meter visibility after 60 seconds, as specified by the standard EN 50131-8:2019, as used as reference by all manufacturers of fog generators, the number of shooting seconds it is to be reduced in half.
INSTALLATION, EXCHANGE AND BAG RESET
Insert the bag in place as show in picture.
Insert a new bag and push metal connector till a “click” is heard.
Metal plug
Press button S1
FRONT LEDS MEANING
EMPTY RESERVE| RED LED (right) ON: Error (Mains power off / Battery low) or
Fault. Blinking: Empty bag or low fluid. OFF: No error condition.
---|---
ARM| BLU LED (center) ON: Unit is armed and ready to shoot (if green led is
already ON). OFF: Unit is disarmed, shot not possible.
HEATING| GREEN LED (left) ON: Unit has reached the correct temperature.
Blinking: Unit is warming, no shot possible. OFF: Device fault.
The EMPTY signal also means that fluid is going LOW. It means that the unit
has shot at least 240 seconds since last reset (COMPACT 390).
| The central RED low power light means unit is correctly powered on.
MAINTENANCE
UR FOG fogging systems don’t need special maintance, nevertheless is suggested a periodical check to the following parts by skilled operators:
- Verify battery and power supply status.
- Verify screws are firmly closed.
- Verify the output nozzle is not damaged and without anything inside.
- Verify pneumatic circuit.
- Verify once a year liquid pump.
BATTERY AND POWER SUPPLY CHECK
Verify that the output of the power supply without any load (battery
unplugged) is 14,1 V on the PSU.
If a different value is noticed, set the trimmer on power supply.
Verify battery status (integrity check, no overheating); is suggested to
replace the battery on 2 years base due to the heavy load during shots without
mains power.
SCREWS
Verify that all fixing screws are correctly setted and eventually rescrew
them.
OUTPUT NOZZLE
Verify that ouput nozzle is not damaged and that there is nothing inside
blocking the fog ejection flow.
YEARLY PUMP FUNCTIONALITY TEST
The test is done executing a trial shot on the unit. To avoid creating too
much fog during the test is suggested to stop the flow after a few seconds
dreaming the unit under test.The fog flow will immediately stop.
RESET FROM FAULT CONDITION
Disconnect the units from any power source, both mains power and battery must
be disconnected.
Wait 5 minutes and reconnect the battery and mains power.
This procedure helps to understand if the fault condition was due to mains
power overload, serious power supply problems or problems in thermal loop.The
fault condition is shown by the RED led ON (LED DL4 on the top), the output
FAULT immediately switch’s and can indicate a transient or fixable condition
(Eg. low battery power or no mains power), or a problem that cannot be fixed
on site.
On mains power fault or battery low conditions the unit will recover itself
without any further operation on it.
In the evenience that the mains power fault has generated further problems to
the unit (Eg. on board fuse) or that the backup battery is not working
anymore, the maintenance is needed.
Note: The RED led (LED DL1, middle of the board), means that unit is ON.
It is NOT a fault condition.
DEFECTS POSSIBLE SOLUTION
DEFECT FOUND | POSSIBLE CAUSE | POSSIBLE SOLUTION |
---|---|---|
Small fog flow coming out from nozzle | All products are 100% and a small | |
amount of liquid could be still in the warming unit. | This condition is normal |
and can happen on first installation, it will completely disappear in a while
when the unit will become completely hot.
RED Led ON (Error)| Too low battery level or exhaust| Replace Battery
Bag in Reserve or Empty| Replace fluid Bag
No Mains power| Check mains power or F4 fuse
RED Led ON (Fault)| Disturbance / interference or potential differences
between devices| In the evenience of high noise on mains power (lightings) an
error while reading thermocouple values can occur.
Execute recovery (Paragraph 16).
If even recovery fails the unit may be faulty
In very large installations or with more than one fog units connected to the
same alarm panel, a mains power difference can occur, in that evenience the
units have to be decoupled.
Error in the thermal loop| Error on thermocouple, fuse cable, resistor. Please
refer to technical service
Heater Temperature too high or thermocouple error| Switch off the unit and
verify the screw on J8 connector
Poor ventilation| Switch off the unit and clean air holes
Unit ARMED (BLUE LED ON) but don’t execute trig command| Red front led
BLINKING| Bag changed, reset needed Follow instructions Paragraph 13
---|---|---
Empty bag – replace it following instructions on Paragraph 13
Green front led is BLINKING| Unit still warming, wait max 60 min. with the
unit connected to the mains power
Wires error| Verify on J10 that when alarm is ON there is a contact between –
GND (Pin 6) + TRIG (Pin 8)
Mains power overload| Try the Recover procedure (Paragraph 16) With no results
replace the board
Electronic Board overheath| Power off the unit and verify air flow near the
unit (Paragraph 14)
Unit cannot be ARMED BLU LED OFF| Wires error| Verify on J10 that when alarm
activates there is a contact between – GND (6) + ARM (7)
While setting shooting time the green LED lights once| The W1 jumper is OPEN,
unit in’ “RESET” mode| Refer to bag Reset (Paragraph 12) and shooting time
setting (Paragraph 11)
Warning: please verify/set again the shooting time.
See time setting (Paragraph 11)
WARRANTY
The warranty of COMPACT 390 is two years and is handled directly from the dealer or authorized installer, so please contact your supplier to take advantage of warranty with the copy of the purchase document that contains the serial number of the machine. Not included in the warranty: moving parts and/or damages depending on the incorrect use unless it is found a manufacturing defect in origin. Liquid and bags are not covered by warranty.
BY BREAKING THE SECURITY LABELS AND THE OPENING OF THE MACHINE YOU WILL ACCEPT WHAT IS WRITTEN ON THIS MANUAL AND ON THE WEB SITE: www.urfog.com
We recommend to throw away the batteries in the appropriate waste containers for recycling. Heavy metals contained in them are recyclable.
UR Fog srl: Via Toscana n. 38 – 10099 San Mauro Torinese – Italy Phone +39 011/01.33.037 – Fax 011/01.33.005 support@urfog.com
Legal office: Via Giacinto Collegno 11 – 10143 – Torino – Italy
RESELLER/INSTALLER STAMP
(company to contact for the warranty)
At the end of the installation, write down the identification number of the machines, the date of the installation and sign in the dedicated spaces.
MAINTENANCE
DATE | BATTERY EXCHANGE | BAG EXCHANGE | SIGNATURE |
---|---|---|---|
YES | NO | YES | NO |
YES | NO | YES | NO |
YES | NO | YES | NO |
YES | NO | YES | NO |
YES | NO | YES | NO |
YES | NO | YES | NO |
YES | NO | YES | NO |
YES | NO | YES | NO |
YES | NO | YES | NO |
YES | NO | YES | NO |
YES | NO | YES | NO |
YES | NO | YES | NO |
YES | NO | YES | NO |
YES | NO | YES | NO |
YES | NO | YES | NO |
YES | NO | YES | NO |
YES | NO | YES | NO |
It is mandatory to fill out this table in accordance with the security rules
CUSTOMERS SUPPORT
N.B. Ask for the PDF module
writing to: support@urfog.com
TO USE UR FOG FOGGING SYSTEMS WITH PURIFOG
FLUIDS FOLLOW THE DATASHEETS INSTRUCTIONS
AVAILABLE FOR DOWNLOAD ON WWW.PURIFOG.COM
UR FOG S.r.l. Via Toscana 38 – 10099 San Mauro Torinese – Italy