OSRAM FLEX ESSENTIAL 24V Led Flex Power Instructions
- June 13, 2024
- OSRAM
Table of Contents
OSRAM FLEX ESSENTIAL 24V Led Flex Power
Product Information:
-
Product Name: OSRAM FLEX ESSENTIAL 24V
-
IP Rating: IP20
-
Series: 2835 ESSENTIAL SERIES
-
Features:
- High CRI (Color Rendering Index) – CRI>80
- High Efficiency – Up to 110lm/w
- High color consistency, within 5 steps SDCM (Standard Deviation of Color Matching)
-
Technical Details:
- Product No.: LD-FLW-R2835W-24-60S-A
- Power(W/M): 14.4
- Voltage(V): 24
- CRI: 80
- Led Qty(LEDs/M): 60
- Length/Reel(M): 5
-
Lumens per Meter:
- 2700K: 1520lm
- 3000K-3500K: 1580lm
- 4000K-4500K: 1620lm
- 6500K-7000K: 1680lm
-
Dimension:
- L1(mm): 5004
- L2(mm): 100
- L3(mm): 16.6
- L4(mm): 360
- W1(mm): 10
- H1(mm): 1.4
-
Working Conditions:
- Temperature Range: -20°C to 50°C
- Humidity Range: -30°C to 80°C
- Operating Voltage: 23-25V DC
-
Safety Warning:
This product is in the [insert safety class] -
Packing:
- Box Dimension(mm): 485x380x260
- Carton Dimension(mm): 360x240x240
- Gross Weight(Kg): [not provided]
- Net Weight(Kg): [not provided]
- Bag Weight(g): [not provided]
- Bag Quantity(bags/carton): 25
Product Usage Instructions
- Ensure that the product is connected to a suitable power source with a voltage of DC 24V.
- Install the OSRAM FLEX ESSENTIAL 24V in an IP20-rated location.
- The product has a length of 5 meters per reel, with 60 LEDs per meter.
- The product provides different levels of brightness depending on the color temperature selected:
- 2700K: 1520 lumens per meter
- 3000K-3500K: 1580 lumens per meter
- 4000K-4500K: 1620 lumens per meter
- 6500K-7000K: 1680 lumens per meter
- Ensure that the product is operating within the recommended working conditions:
- Temperature Range: -20°C to 50°C
- Humidity Range: -30°C to 80°C
- Operating Voltage: 23-25V DC
- Follow the provided safety warnings for proper usage of the product.
FEATURE
- High CRI; CRI>80
- High Efficiency, Up to 110lm/w
- High color consistency, within 5 steps SDCM
TECHNICAL DETAILS
Product No.|
---|---
Power(W/M)| 14.4
Voltage(V)| 24
CRI| 80
Led Qty(LEDs/M)| 60
Length/Reel(M)| 5
COLOR TEMPERATURE
- The given data are typical values. Due to tolerances of the produc?on process and the electrical components, values for light output and electrical power can vary up to 10%.
DIMENSION
- The given data are typical values. Due to tolerances of the produc?on process and the electrical components, values for light output and electrical power can vary up to 10%.
LIGHT DISTRIBUTION
WORKING CONDITIONS
- Working Temperature (°C): -20~50
- Storage Temperature(°C): -30~80
- Voltage Range(V dc): 23 ~25
- Reverse Voltage(V dc): 25
SAFETY WARNING
-
Install in accordance with national standards and local electrical codes.
-
This product must be installed and maintained by a qualified electrician.
-
Only install it with Class 2 DC constant voltage driver, Do not use this product if it does not comply with Class 2 standard.
-
The power of drive must meet the output of the rated power, and do not exceed the specified output power.
-
Use a cable with rated temperature at least 80 ° C and be certified for external connection of the electrical equipment.
-
Improper electrical installation may cause the cable to overheat and cause a fire. Please use a suitable cable between the driver, the lamp, and the controller. When selecting a wire, the voltage and current must meet the rated values.
-
The LED module itself and all its components must not be mechanically stressed.
-
Assembly must not damage or destroy conducting paths on the circuit board.
-
To avoid mechanical damage, the LED modules should be attached securely to the intended substrate. Heavy vibration should be avoided. Installation of LED modules (with power supplies) needs to be made with regard to all applicable electrical and safety standards. Only qualified personnel should be allowed to perform installations.
-
Observe correct polarity! Incorrect polarity will lead to no light emission and may cause damage of the LED module.
” Parallel connection is highly recommended as safe electrical operation mode. Serial connection is not recommended. Unbalanced voltage drop can cause hazardous overload and damage the LED module. -
When mounting on metallic or otherwise conductive surfaces, there needs to be a electrical isolation at soldering points between module and the mounting surface.
-
Pay attention to ESD steps when mounting the module.
Please ensure that the power supply is of adequate power to operate the total load. -
Damage by corrosion will not be honored as a materials defect claim. It is the user’s responsibility to provide suitable protection against corrosive agents such as moisture and condensation and other harmful elements.
-
For applications involving exposure to humidity and dust the module must be protected by a fixture or housing with a suitable protection class.
PACKING
- Box dimension(mm): 485x380x260
- Carton dimension(mm): 360x240x240
- Gross weight(Kg): /
- Net weight(Kg): /
- Bag weight(g): /
- Bag quantity(bags/carton): 25