INTRODUCTION

Thank You for choosing one of Our products! Please refer to the instructions and warnings contained in this user manual, please retain it for future reference. This manual contains information about the installation and use of the device. The information contained in this publication has been carefully prepared and checked. However, it is not assume any responsibility for any inaccuracies. All rights are reserved and this document can not be copied, photocopied, reproduced in whole or in part without previous written permission of PROEL. PROEL reserves the right to make, without notice, any aesthetical, functional or design changes or modifications in every one of its products. PROEL doesn’t assume any responsibility for the use or application of the products here described. The crossed bin symbol, shown on the product or on accompanying documents, indicates that the product should not be disposed with other household waste at the end of the lifecycle. To avoid any damage to the environment, the user is encouraged to separate this product from other kinds of waste and recycle it responsibly to promote the sustainable reuse of material resources. Home users are encouraged to contact the retailer where they purchased this product or their local government office for details on separate collection and recycling this type of product. Business users are encouraged to contact their supplier and check the terms and conditions of the purchase contract. This product should not be mixed with other commercial waste.

  • The lightning symbol with an arrow in an equilateral triangle intends to alert the user to the presence of not insulated “dangerous voltages” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
  • The exclamation point symbol within an equilateral triangle intends to alert the user to the presence of important instructions for use and maintenance on the accompanying documents of the product.
  • The “F” inside an equilateral reversed triangle means that the product is suitable for mounting on normally flammable surfaces.
  • The product to which this manual refers complies with the European Directives pursuant to the safety of electrical equipment supplied at low voltage (LVD) and to the Electromagnetic Compatibility (EMC)

SAFETY INSTRUCTIONS

Caution! This product is not suitable for household illumination. Please read this manual before installing and applying power to the equipment, follow the safety precautions listed below and observe all warnings in this manual and printed on. Please contact a PROEL distributor for assistance with any questions about how to activate the equipment safely. Contact a qualified technician for any maintenance work not described in this manual.
Do not modify the fixture or install accessories and upgrade kits that are not the Proel original ones.

People involved in the installation and maintenance of the device must:

  • Be qualified
  • Follow the instructions of this manual in the theaters, in the halls, in the places where the events take place, etc.

CHECKS BEFORE INSTALLATION
Make sure all the parts for fixing the product are in good condition. Make sure that the anchor point is stable before positioning the product. The safety cable must be properly attached to the device and fixed to the supporting structure so that, in case of failure of the primary supporting system, it has the lowest possible fall of the device. If the safety cable wear, must be replaced with an original spare.

MINIMUM DISTANCE OF ILLUMINATED OBJECTS
The projector must be positioned so that the objects hit by the beam of light are at least 2 meters from the lens of the projector.

MINIMUM DISTANCE FROM FLAMMABLE MATERIALS
The product must be positioned so that any flammable material is at least 0.50 meters from any point of the surface of the device. Never place filters or other materials over the lens or on the optical axis.

MOUNTING SURFACES
The device is suitable for mounting on normally flammable surfaces.

REFERENCE TEMPERATURE
The ambient temperature range of use of the device varies between + 5 ° C (min) and + 40 ° C (max), outside of that range the device should not be used. The maximum temperature of the housing Tb = 80 ° C must never be exceeded. Do not block the exhaust fans, ensuring a minimum clearance of 0.5 meters around the ventilation holes.

IP20 PROTECTION RATING
The device is protected against the penetration of solid bodies larger than 12 mm (0,47 “) in diameter (first digit 2), but not against dripping water, rain, splashes or jets of water (second digit 0). Use only in dry areas. Inside use only. Do not expose the equipment to rain or moisture.

PROTECTION AGAIN ELECTRIC SHOCK
The device must be connected to a power supply system with efficient earthing. Moreover, it is recommended to protect the power supply lines of the product from indirect contact and/or shorting to earth by using an appropriately sized anti-electrical shock switch.

CONNECTION TO THE MAINS
The electrical connection must be carried out by a qualified electrician. Ensure that the mains frequency and voltage correspond to those for which the equipment is designed, as shown in the electrical data label. This label also shows the power consumption that is necessary to refer to evaluate the maximum number of devices to be connected to the electricity line, in order to avoid power overloading. If the external power cord of this light is damaged, it must be replaced with a special cord exclusively available from Your PROEL dealer. Never operate the equipment with lenses and/or covers missing or damaged. In case of non-use, it is recommended to unplug the projector from the mains.

MAINTENANCE

Before starting any maintenance or cleaning the product, disconnect the power from the mains and disconnect the power cable from the device. After switching off, do not remove any part of the device for at least 35 minutes to avoid the risk of burns. The lenses, if damaged, must be replaced with original spare parts.

CAUTION. Do not look directly at the light source. Do not look at the beam with lenses, glasses, mirrors or similar optical instruments that could change the convergence of light, causing serious damage to people and/or things.
WARNING! DANGER FOR THE EYES! Do not look directly at the light source

OPENING AND CONTROL

Carefully open the package, check the content, and make sure that all the parts are present and are in good condition. In cases where some parts are not present or are damaged, immediately contact Your supplier and retain the packaging for verification.

WARNING!
If the product has been exposed to drastic temperature changes, let the unit be turned off until it reaches room temperature because the presence of condensation can damage the product if it is turned on.

Verify that the box contains the following items:

  • N° 1 SG JBEAM230
  • N° 2 Omega holders
  • N° 1 Power cord
  • N° 1 User Manual

FRONT VIEW

  1.  Lens
  2. Display + buttons

REAR VIEW

  1. Dmx OUT
  2. Dmx IN
  3. Power OUT
  4. Power IN
  5. Switch ON/OFF
  6. Fuse
  7. USB connector for wireless (SG WECONUSB sold separately)

INSTALLATION AND SWITCH ON

PRODUCT INSTALLATION

  • Do not shake the device. Avoid the use of too much force during installation or unit fixing.
  • The unit can be installed on the floor resting on the rubber feet, on the wall, ceiling or on a truss.

WARNING! IT’S REQUIRED
the mounting of the safety rope (PLH232 – PLH248) sold separately) in the case where the product is hung on a wall, ceiling or on a truss. Except when the device is placed in the floor, the safety cable is always required.

CONNECTION TO THE MAINS

The device must be connected to a power supply system with a proper earth system. Moreover, it is recommended to protect the power supply lines of the products from indirect contact and/or shorting to earth by using an appropriately sized anti-electrical shock switch. The electrical connection must be carried out by a qualified electrician. Ensure that the mains frequency and voltage correspond to those for which the device is designed, as shown in the electrical data label.

CONNECTION TO THE DMX CHAIN

Use a cable conforming to specifications EIA RS-485: pole twisted, shielded, 120Ohm characteristic impedance and low capacity (SAGITTER SG DMX3 – SG DMX5). Do not use a microphone cable or other cable with different characteristics than those specified. Terminations must be made with male/female XLR 3-pin connectors. You must enter on the last device a terminal plug with a 120Ohm resistance (min1 / 4 W) between terminals 2 and 3. IMPORTANT: The cables must not come into contact with each other or with the metal housing of the connectors. The housing itself must be connected to the shield braid and to pin 1 of the connectors.

SETUP

Highlighted the default values

Level 1 Level 2 Level 3 Level 4 Description

DMX

| Dmx Address|  |  |

Channel Mode

| 13CH|  |
15CH|  |
17CH|  |
Auto Run| Program 1…9| Master|
Alone|
Music Run| Program 1…9| Master|
Alone|

SET

| Reset Default| Yes/No|  |
Signal Set| Wire|  |
Wireless|  |
Reverse Pan|  | OFF| /ON|  |
Reverse Tilt|  | OFF| /ON|  |
Select Pan| 360/540/630|  |
Select Tilt| 90/180/270|  |
Mic Sentitivity| 000…099|  |

OFF Signal Mode

|

OFF/ON

|  | OFF: the projector remain in the same position if the DMX signal is lost

ON: the projector comes to zero position if the DMX signal is lost

Start Up Lamp

|

OFF/ON

|  | Switch ON the lamp when the projector is switched ON

(please use this function only if

needed)

Manu

|

Reset

| Total Reset|  | Reset of all motors
Scan Reset|  | Reset of Pan/Tilt motors
Color Reset|  | Reset of color wheel
Gobo Reset|  | Reset of gobo wheel
Strobe Reset|  | Reset of strobe palettes
Other Reset|  | Reset of other motors

Channel

| Pan (000 – 255)|  |

Manual control of each channel

Pan Fine ( 000 – 255)|
…|

ADV

(pwd=088)

|

Calibration

| Pan (000 – 255)|  |
Tilt (000 – 255)|  |
…|  |
Lamp Time Clear|  |  |
UID| XX XX XX XX XX XX|  |

MASTER/SLAVE MODE
In this mode, more units can be linked together as a single chain and work in a synchronized way.

  • Use a DMX cable to link together all the units from the connector DMX OUT to DMX IN.
  • Define the first unit of the chain as MASTER, all other units will be SLAVE and they must be set DMX = 001.
  • Operate the Master unit in Automatic mode or Sound mode to operate the entire system. The entire chain of Slave unit will act as the Master unit.

DMX MODE

Channel mode| Function| Values| Description|
---|---|---|---|---
13 CH| 15 CH| 17 CH|  |  |  |
1| 1| 1| Pan| 000 – 255| Pan movement|
2| 2| 2| Pan fine| 000 – 255| Pan fine movement|
3| 3| 3| Tilt| 000 – 255| Tilt|
4| 4| 4| Tilt fine| 000 – 255| Tilt fine movement|
 |  |  |  | 000 – 009| Open|
 |  |  |  | 010 – 019| Red|
 |  |  |  | 020 – 029| Blue|
 |  |  |  | 030 – 039| Green|
 |  |  |  | 040 – 049| Yellow|
 |  |  | Color wheel| 050 – 059| Magenta|
060 – 069| Cyan|
5| 5| 5| (see next table in| 070 – 079| Pink|
080 – 089| Orange|
 |  |  | case Half Color|
090 – 099| CTO|
 |  |  | option = ON)|
100 – 109| CTB|
 |  |  |  | 110 – 127| UV|
 |  |  |  | 128 – 189| Counterclockwise rotation from fast to|
 |  |  |  | slow|
 |  |  |  | 190 – 193| Rotation stop|
 |  |  |  | 194 – 255| Clockwise rotation from slow to fast|

6

|

6

|

6

|

Gobo wheel

| 000 – 004| Open|
005 – 009| Gobo 1|
010 – 014| Gobo 2|
015 – 019| Gobo 3|
020 – 024| Gobo 4|
025 – 029| Gobo 5|
030 – 034| Gobo 6|
035 – 039| Gobo 7|
040 – 044| Gobo 8|
045 – 049| Gobo 9|
050 – 054| Gobo 10|
055 – 059| Gobo 11|
060 – 064| Gobo 12|
065 – 069| Gobo 13|
070 – 074| Gobo 14|
075 – 079| Gobo 15|
080 – 084| Gobo 16|

 |  |  |  | 085 – 092| Gobo 1 shacking from slow to fast
093 – 100| Gobo 2 shacking from slow to fast
101 – 107| Gobo 3 shacking from slow to fast
108 – 116| Gobo 4 shacking from slow to fast
117 – 124| Gobo 5 shacking from slow to fast
125 – 132| Gobo 6 shacking from slow to fast
133 – 140| Gobo 7 shacking from slow to fast
141 – 148| Gobo 8 shacking from slow to fast
149 – 156| Gobo 9 shacking from slow to fast
157 – 164| Gobo 10 shacking from slow to fast
165 – 172| Gobo 11 shacking from slow to fast
173 – 180| Gobo 12 shacking from slow to fast
181 – 188| Gobo 13 shacking from slow to fast
189 – 196| Gobo 14 shacking from slow to fast
197 – 204| Gobo 15 shacking from slow to fast
205 – 212| Gobo 16 shacking from slow to fast
213 – 255| Rainbow Gobo from slow to fast

7

|

7

|

7

|

Strobe

| 000 – 031| Shutter closed
032 – 063| Open
064 – 095| Strobe effect from slow to fast
096 – 127| Open
128 – 143| Pulse in from slow to fast
144 – 159| Pulse out from fast to slow
160 – 191| Open
192 – 223| Random strobe from slow to fast
224 – 255| Open
8| 8| 8| Dimmer| 000 – 255| Dimmer 0-100%
9| 9| 9| Focus| 000 – 255| Focus from near to far
 | 10| 10| Prism 1| 000 – 005| No prism
006 – 255| Prism 1 inserted
 | 11| 11| Prism 2| 000 – 005| No prism
006 – 255| Prism 2 inserted
 |

12

|

12

|

Prism rotation

| 000 – 063| No rotation
064 – 127| Forward rotation from fast to slow
128 – 191| Stop rotation
192 – 255| Backward rotation from slow to fast

10

|  |  |

Prism 1

| 000 – 005| Prism 1 not inserted
006 – 127| Prism inserted
128 – 189| Clockwise rotation from fast to slow
190 – 193| Stop rotation
194 – 255| Counterclockwise rotation from slow to

fast

11| 13| 13| Frost| 000 – 199| Frost not inserted
200 – 255| Frost inserted

12

|

14

|

14

|

Pan/Tilt speed

| 000 – 225| Speed from max to min
226 – 235| Blackout by Pan/Tilt movement
236 – 245| Blackout by Color/Gobo movement
246 – 255| No function

13

|

15

|

15

|

Special functions

| 000 – 019| No function
020 – 039| No function
040 – 059| Lamp ON
060 – 079| Lamp OFF
080 – 084| Total reset
 |  |  |  | 085 – 087| Pan/Tilt reset
---|---|---|---|---|---
088 – 090| Color Reset
091 – 093| Gobo Reset
094 – 096| Strobe Reset
097 – 099| Other reset
100 – 119| Internal program 1
120 – 139| Internal program 2
140 – 159| Internal program 3
160 – 179| Internal program 4
180 – 199| Internal program 5
200 – 219| Internal program 6
220 – 239| Internal program 7
240 – 255| Internal Sound program 1
 |  | 16| Color Time| 000 – 255| Color insertion speed from fast to slow
 |  | 17| Gobo Time| 000 – 255| Gobo insertion speed from fast to slow

Color Channel detail in case of Half Color option = ON

Channel mode Function Values Description
13 CH 15 CH 17 CH  

5

|

5

|

5

|

Color wheel

Half Color option = ON

| 000 – 004| Open
005 – 009| Open / Red
010 – 014| Red
015 – 019| Red / Blue
020 – 024| Blue
025 – 029| Blue / Green
030 – 034| Green
035 – 039| Green / Yellow
040 – 044| Yellow
045 – 049| Yellow / Magenta
050 – 054| Magenta
055 – 059| Magenta / Cyan
060 – 064| Cyan
065 – 069| Cyan / Pink
070 – 074| Pink
075 – 079| Pink / Orange
080 – 084| Orange
085 – 089| Orange / CTO
090 – 094| CTO
095 – 099| CTO / CTB
100 – 104| CTB
105 – 109| CTB / UV
110 – 114| UV
115 – 127| UV / Open
128 – 189| Counterclockwise rotation from fast to slow
190 – 193| Rotation stop
194 – 255| Clockwise rotation from slow to fast

MAINTENANCE

To ensure optimal performance, the unit must be frequently cleaned. Unplug the device from the mains and let it cool for at least 35 minutes to avoid the risk of burns. Use a vacuum cleaner or an air compressor and a soft brush or a lens cloth to remove the dust deposited. The lenses, like any other damaged part, must be replaced with original spare parts.

TECHNICAL SPECIFICATIONS

  • Power Supply : 100-240V, 50/60HZ
  • Lamp: Osram SIRIUS HRI 231W
  • PAN angle: 360° – 540° – 630
  • TILT angle: 90° – 180° – 270°
  • Power consumption: 360W
  • Operation modes: Auto, Sound, Master/slave, DMX512
  • Electronic Dimming 0-100%
  • DMX: 13 – 15 – 17 channels
  • Digital display for address and function setting
  • Dimensions (L x H x D): mm. 338x469x224
  • Weight kg 12,5

is a brand of PROEL SPA (Worldwide Headquarters) Via alla Ruenia, 37/43 64027 Sant’Omero (TE) – ITALY Tel. +39 0861 81241 Fax +39 0861 887862 P.I. 00778590679 N.Reg.AEE IT 08020000002762