Elitech GSP-8A Temperature and Humidity Data Logger Recorder Audio Alarm User Manual
- June 13, 2024
- Elitech
Table of Contents
GSP-8
User Manual
Overview
GSP-8 data logger s used to record the temperature/humidity of foods, medicines, chemicals and other goods during storage, transportation and i each stage of the cold chain including cooler bags, cooling cabinets, refrigerators, medicine cabinets, laboratories, reefer containers,and trucks, ‘The logger features a arge LCD screen, one button for operation, an internal temperature sensor, and an external temperature-humidity-combined probe (optional). It supports audible-visual alarm, two storage modes, and auto shortens logging interval function during alarms. also for wall mounting through the holes at the back of logger.
- DLEDIndicator
- LCD Screen
- IsulatorStrip
- Button
- Short External Temperature-humidity Probe (optional)
- Long External Temperature-humidity Probe (2m, optional)
Specifications
Sensor | Digital temperature humidity sensor |
---|
Temperature
Measurement Range| Internal sensor: -20∼60°C (-4°F~140°F);
External probe: -40∼85°C (-40°F~185°F) *
Humidity
Measurement Range| External probe: 1~99%RH
Temperature Accuracy| ± 03’C/± 0.6°F (-20∼40°C) , ± 0.5°C/+0.9°F (others)
Humidity Accuracy| ±3%RH (25°C)
±5%RH (others) M183
Operating
Temperature Range| -20∼60°C (-4°F~140°F)
Ambient Temperature during power charging| 0~40°C (32°F~104°F)
Resolution| 01°C/’F; 01%RH
Memory| Maximum 100,000 points
Logging Interval| 10 seconds ta 24 hours
LCD ON| 15/30/45/60 seconds; always on
Backlight ON| 15/30/45/60 seconds; always on
Start Mode| Press button; auto start; timed start
Stop Mode| Press button; use software; auto stop
Alarm Thresholds
Data Interface| Configurable, temperatue: up to 3 high limits and 5 1o, imits;
humidity:
1 high limit and 1 low limit
Alarm Type| Single; cumulative
Alarm Delay| 10 seconds to 24 hours
Data Interface| USB
Report Format| A0 POF et
PDF/EXCEL/TXT** by ElitechLog software
Battery| Rechargeable 18650 lithium battery
battery life| Store and use for 2 years
(@25°C and 15 minutes logging interval)
Dimensions| 94x90x29 mm
Weight| 173
- At ultralow temperoture, the LCD is slow but does rot offect normal Iogging. ft will be back to normol after the temperature rises.
“*TXT for Windows ONLY.
Operation
-
Activate Logger
Pull out the insulator strip from the side of the logger to activate the battery. -
Install Software
Please download and install the free ElitechLog software (mac0S and Windows) via www.elitechlog.com. -
Configure Parameters
First, connect the data logger to the computer via USB cable, wait until the icon shows on the LCD, then configure via:
ElitechLog software:
– If you do not need to change the default parameters (in Appendix); please click Quick Reset under Summary menu to synchronize local time before usage:
– If you need to change the parameters, please click the Parameter menu, enter your preferred values, and click the Save Parameter button to complete the configuration.
Warning! For first time user or after battery replacement: To avoid time or time zone errors, pleose make sure you click Quick Reset or Save Parameter before usage to sync and configure your local time into the logger. -
Start Logging
Press Button:
Press and hold the button for 5 seconds until the icon shows on the LCD, indicating the logger starts logging Auto Start:
Immediate Start: The logger starts logging after remove it from the computer.
Timed Start: The logger starts counting after being removed from the computer; it will start logeing automatically after the set date/time.
Note: If the icon keeps floshing, it means the logger configured with stort delay; it willstart logging after the set delay time elapses -
Mark Events
Double click the button to mark current temperature and time, up to 10 groups of data. After marked, it will be indicated by Log X and SUC on the LCD screen (X means the marked group) -
Stop Logging
Press Button®: Press and hold the button for 5 seconds until the icon shows on the LCD, indicating the logger stops logging.
Auto Stop: When the logging points reach the maximum memory, the Iogger will stop automatically.
Use Software: Open Elitechlog software, click Summary menu, and Stop Logging button
Note: “Default stop method is Press Button. If you disabled it, the button operation would be invalid; please open the ElitechLog software. and click Stop Logging button to stop it The Auto Stop function will be disabled automatically if you enabled the Circular Logging -
Download Data
Connect the data logger to the computer via USB cable, wait until 2 shows on the LCD screen, then download data:
Without ElitechLog Software: Simply find and open the removable storage device ElitechLog, save the auto generated PDF report to your computer for viewing With ElitechLog software: After the logger auto-upload its data to the ElitechLog software, click Export and select your preferred file format to export. If data failed to auto-upload, please manually click Download and then repeat above operation. -
Reuse the Logger
To reuse a logger, please stopped it first; then connect it to your computer and use ElitechLog software to save or export the data.
Next, reconfigure the logger by repeating the operations in 3. Configure Parameters. After finished, follow 4. Start Logging to restart the logger for new logging.
Warning! To make space for the new loggings, All previous logging data inside the logger will be deleted ofter re-configuration, f you forgot to save/export dato, please try to locate the logger in the History meru of ElitechLog software. -
Repeat Start:
If you have enabled Repeat Start function”, simply press and hold the button for § seconds to quickly restart the stopped logger without any configuration.
Note: * Repeat Start i disabled by defoult to prevent dota loss coused by misoperation. Pleose backup data before Repeat Start by repeating 7.Download Data.
Status Indication
- Buttons****
Operations| Function
---|---
Press and hold the button for S seconds| Start/Stop logging
Press and release the button| Check/Switch interfaces
Double click the button| Mark events - LCD Screen****
1. BatteryLevel
2. Functions
3. Channel Selection
4. Over Limit Alarm| 5. Connected to PC
6. Stopped/Logging
7. Circular Logging
8. Buzzer (Enabled)| 9. Temperature
10. Humidity
11. Logging Interval/Date or Time
---|---|--- - LCD Interface****
Not Start :| | Maximum:|
---|---|---|---
Delay/Timed Start ( flashes)| | Minimum:|
Logging:| | High Limit:|
Average:| | Low Limit :|
Note: I configured to use the internol sensor (temp). the hurmidity will not
disploy by defoult.
- LED & Buzzer Indication**
LED Indicator| Buzzer*| Meaning…*
---|---|---
flash once| beeps once| Configuration completed
flash twice| beeps twice| Started
flash 3 times| beeps 3 times| Stopped
flash 4 times| beeps 4 times| Timed/Delay start
flash once every 15 seconds| in alarm status|
flashes once every 1 seconds| /| Charging
always on, and then off| /| Charged
Battery Charging
Connect the included USB cable into a computer or poweradapter for battery charging.
Wall Mounting
GSP-8 supports hanging-mount and stand (optional) only, please confirm the installation distance and preferred nail size before hanging the logger to wall (nail not included).
What’s Included
- GSP-8 Temperature (Humidity) Data Logger x 1
- Micro USB Cable x 1
- User Manual x1
- Certificate of Verification x 1
- Long External Temperature-humidity Probe (2m) x 1 (Optional)
- Certificate of Verification (2m) x 1 (Optional)
- Short External Temperature-humidity Probe x 1 (Optional)
- Certificate of Verification (Short) x 1 (Optional)
- Stand x1 (Optional)
Warning!
Ifyou use the logger for the first time, pleose use ElitechL og software to
synchronize syster time and configure parameters.
Any parameter configuration on ElitechLog softwore will defete oll Iogged dota
inside the logger. Please save data before you opply new configurations
The LLD screen will auto off after 15 seconds of inactiviy (by default) Press
the button again to turn on the screen. The backiight ON time is configurable
via ElitechLog software.
To ensure the humidity accuracy, please avoid contact with unstable chemical
solvents or compounds, especially avoid fong-term storage or exposure to the
environments with high concentrations of ketene, acetone, ethariol,
isopropanol, toluene, etc.
Recommended to remove the battery from the – side (cathode).
Appendix
Default Parameters:
Logging Interval | 15 minutes |
---|---|
High Temperature Limit | 60 |
Low Temperatura Limit | 0°C |
Button Tone | Enable |
Audible Alarm | Disable |
Logging interval shortened in alarm | Disable |
Loon | 15 seconds |
Backdight ON | OFF |
Elitech Technology, INC.
wwwlitechlog.com
1551 McCarthy Bivd, Suite 112
Milpitas, CA 95035 USA
Documents / Resources
|
Elitech GSP-8A Temperature and Humidity Data Logger Recorder Audio
Alarm
[pdf] User Manual
GSP-8A, GSP-8A Temperature and Humidity Data Logger Recorder Audio Alarm,
Temperature and Humidity Data Logger Recorder Audio Alarm, Humidity Data
Logger Recorder Audio Alarm, Data Logger Recorder Audio Alarm, Logger Recorder
Audio Alarm, Recorder Audio Alarm, Audio Alarm, Alarm
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>