SWEBAD FALSTERBO 150 Classic Rectangular Bathtub Installation Guide
- June 4, 2024
- SWEBAD
Table of Contents
SWEBAD FALSTERBO 150 Classic Rectangular Bathtub Installation Guide
FALSTERBO 150
- Length of the power cable min. 2 m. Thickness of cable and number of cores depends on performance of the device and should meet the local requirements. Connections must be made by an authorised electrician.
- Closable cold and hot water input G ½.
- Sewage opening D = 50 mm
System
| Voltage| Power|
Current
---|---|---|---
Standard| –| –| –
Bra| 230 V| 900 W| 4,7 A
Bättre| 230 V| 1400 W| 6,9 A
Design| 230 V| 1500 W| 6,6 A
Lyx| 230 V| 2000 W| 8,8 A
NB! Heater is included in some systems
1,5 kW (Design)| 230 V| 1500 W| 6,6 A
3,0 kW (Lyx)| 230 V| 3000 W| 13,0 A
ELECTRIC SPECIFICATION
All electrical connections related to the installation of the product must be
executed by a certified professional electrician.
At connecting, all local regulations must be observed as well as permissible
load on one phase. To achieve local auxiliary equipotential bonding, make sure
you connect all conductive objects in the same room with the earthing terminal
of the product’s aluminium frame:
The cross-section of the copper earth continuity connector must be a minimum
of 2.5 sq mm. The power circuit of the product must be protected with a
residual current circuit breaker with 30mA threshold and a circuit breaker the
operating current of which is levelled with the consumed current of the
product. The product is connected to the electrical power line as a stationary
device, with no plug connector. The length of the power line should allow
moving the product away from walls if necessary. Options for connecting to the
power network according to local opportunities are given on the diagrams
below.
- Power network (230V, 50Hz)
- Circuit-breaker
- Residual current circuit breaker
- Bath terminals
FALSTERBO 160
- Length of the power cable min. 2 m. Thickness of cable and number of cores depends on performance of the device and should meet the local requirements. Connections must be made by an authorised electrician.
- Closable cold and hot water input G ½.
- Sewage opening D = 50 mm
System
| Voltage| Rated power|
Rated current
---|---|---|---
Standard| –| –| –
Bra| 230 V| 900 W| 4,7 A
Bättre| 230 V| 1400 W| 6,9 A
Design| 230 V| 1500 W| 6,6 A
Lyx| 230 V| 2000 W| 8,8 A
NB! Heater is included in some systems
1,5 kW (Design)| 230 V| 1500 W| 6,6 A
3,0 kW (Lyx)| 230 V| 3000 W| 13,0 A
ELECTRIC SPECIFICATION
All electrical connections related to the installation of the product must be
executed by a certified professional electrician.
At connecting, all local regulations must be observed as well as permissible
load on one phase. To achieve local auxiliary equipotential bonding, make sure
you connect all conductive objects in the same room with the earthing terminal
of the product’s aluminium frame:
The cross-section of the copper earth continuity connector must be a minimum
of 2.5 sq mm. The power circuit of the product must be protected with a
residual current circuit breaker with 30mA threshold and a circuit breaker the
operating current of which is levelled with the consumed current of the
product. The product is connected to the electrical power line as a stationary
device, with no plug connector. The length of the power line should allow
moving the product away from walls if necessary. Options for connecting to the
power network according to local opportunities are given on the diagrams
below.
- Power network (230V, 50Hz)
- Circuit-breaker
- Residual current circuit breaker
- Bath terminals
FALSTERBO 170
- Length of the power cable min. 2 m. Thickness of cable and number of cores depends on performance of the device and should meet the local requirements. Connections must be made by an authorised electrician.
- Closable cold and hot water input G ½.
- Sewage opening D = 50 mm
System| Voltage| Rated power|
Rated current
---|---|---|---
Standard| –| –| –
Bra| 230 V| 900 W| 4,7 A
Bättre| 230 V| 1400 W| 6,9 A
Design| 230 V| 1500 W| 6,6 A
Lyx| 230 V| 2000 W| 8,8 A
NB! Heater is included in some systems
1,5 kW (Design)| 230 V| 1500 W| 6,6 A
3,0 kW (Lyx)| 230 V| 3000 W| 13,0 A
ELECTRIC SPECIFICATION
All electrical connections related to the installation of the product must be
executed by a certified professional electrician.
At connecting, all local regulations must be observed as well as permissible
load on one phase. To achieve local auxiliary equipotential bonding, make sure
you connect all conductive objects in the same room with the earthing terminal
of the product’s aluminium frame: The cross-section of the copper earth
continuity connector must be a minimum of 2.5 sq mm. The power circuit of the
product must be protected with a residual current circuit breaker with 30mA
threshold and a circuit breaker the operating current of which is levelled
with the consumed current of the product. The product is connected to the
electrical power line as a stationary device, with no plug connector. The
length of the power line should allow moving the product away from walls if
necessary. Options for connecting to the power network according to local
opportunities are given on the diagrams below.
- Power network (230V, 50Hz)
- Circuit-breaker
- Residual current circuit breaker
- Bath terminals
FALSTERBO XL 180
- Length of the power cable min. 2 m. Thickness of cable and number of cores depends on performance of the device and should meet the local requirements. Connections must be made by an authorised electrician.
- Closable cold and hot water input G ½.
- Sewage opening D = 50 mm
System| Voltage| Rated power|
Rated current
---|---|---|---
Standard| –| –| –
Bra| 230 V| 1100 W| 4,7 A
Bättre| 230 V| 1600 W| 6,9 A
Design| 230 V| 1500 W| 6,6 A
Lyx| 230 V| 2000 W| 8,8 A
NB! Heater is included in some systems
1,5 kW (Bättre, Design)| 230 V| 1500 W| 6,6 A
3,0 kW (Lyx)| 230 V| 3000 W| 13,0 A
ELECTRIC SPECIFICATION
All electrical connections related to the installation of the product must be
executed by a certified professional electrician.
At connecting, all local regulations must be observed as well as permissible
load on one phase. To achieve local auxiliary equipotential bonding, make sure
you connect all conductive objects in the same room with the earthing terminal
of the product’s aluminium frame:
The cross-section of the copper earth continuity connector must be a minimum
of 2.5 sq mm. The power circuit of the product must be protected with a
residual current circuit breaker with 30mA threshold and a circuit breaker the
operating current of which is levelled with the consumed current of the
product. The product is connected to the electrical power line as a stationary
device, with no plug connector. The length of the power line should allow
moving the product away from walls if necessary. Options for connecting to the
power network according to local opportunities are given on the diagrams
below.
- Power network (230V, 50Hz)
- Circuit-breaker
- Residual current circuit breaker
- Bath terminals