Foreword
General
This manual introduces the installation, functions and operations of the
Wireless WallSwitch (hereinafter referred to as the “wallswitch”). Read
carefully before using the device, and keep the manual safe for future
reference.
Model
DHI-ARM7012-W2(868); DHI-ARM7012-W2
Safety Instructions
The following signal words might appear in the manual.
Signal Words | Meaning |
---|---|
DANGER | Indicates a high potential hazard which, if not avoided, will |
result in death or serious injury.
WARNING| Indicates a medium or low potential hazard which, if not
avoided, could result in slight or moderate injury.
CAUTION| Indicates a potential risk which, if not avoided, could result
in property damage, data loss, reductions in performance, or unpredictable
results.
TIPS| Provides methods to help you solve a problem or save time.
NOTE| Provides additional information as a supplement to the text.
Revision History
Version | Revision Content | Release Time |
---|---|---|
V1.0.0 | First release. | November 2022 |
Privacy Protection Notice
As the device user or data controller, you might collect the personal data of
others such as their face, fingerprints, and license plate number. You need to
be in compliance with your local privacy protection laws and regulations to
protect the legitimate rights and interests of other people by implementing
measures which include but are not limited: Providing clear and visible
identification to inform people of the existence of the surveillance area and
provide required contact information.
About the Manual
-
The manual is for reference only. Slight differences might be found between the manual and the product.
-
We are not liable for losses incurred due to operating the product in ways that are not in compliance with the manual.
-
The manual will be updated according to the latest laws and regulations of related jurisdictions.
For detailed information, see the paper user’s manual, use our CD-ROM, scan the QR code or visit our official website. The manual is for reference only. Slight differences might be found between the electronic version and the paper version. -
All designs and software are subject to change without prior written notice. Product updates might result in some differences appearing between the actual product and the manual. Please contact customer service for the latest program and supplementary documentation.
-
There might be errors in the print or deviations in the description of the functions, operations and technical data. If there is any doubt or dispute, we reserve the right of final explanation.
-
Upgrade the reader software or try other mainstream reader software if the manual (in PDF format) cannot be opened.
-
All trademarks, registered trademarks and company names in the manual are properties of their respective owners.
-
Please visit our website, contact the supplier or customer service if any problems occur while using the device.
-
If there is any uncertainty or controversy, we reserve the right of final explanation.
Important Safeguards and Warnings
This section introduces content covering the proper handling of the wallswitch, hazard protection, and protection of property damage. Read carefully before using the wallswitch, and comply with the guidelines when using it.
Operation Requirements
- Make sure that the power supply of the wallswitch works properly before use.
- Do not pull out the power cable of the wallswitch while it is powered on.
- Only use the wallswitch within the rated power range.
- Transport, use and store the device under allowed humidity and temperature conditions.
- Prevent liquids from splashing or dripping on the device. Make sure that there are no objects filled with liquid on top of the wallswitch to avoid liquids flowing into it.
- Do not disassemble the wallswitch.
Installation Requirements
WARNING
-
Connect the wallswitch to the adapter before power on.
-
Strictly abide by local electrical safety standards, and make sure that the voltage in the area is steady and conforms to the power requirements of the wallswitch.
-
Do not connect the wallswitch to more than one power supply. Otherwise, the might become damaged.
-
Observe all safety procedures and wear required protective equipment provided for your use while working at heights.
-
Do not expose the wallswitch to direct sunlight or heat sources.
-
Do not install the wallswitch in humid, dusty or smoky places.
-
Install the wallswitch in a well-ventilated place, and do not block the ventilator of the device.
-
Use the power adapter or case power supply provided by the device manufacturer.
-
The power supply must conform to the requirements of ES1 in IEC 62368-1 standard and be no higher than PS2. Note that the power supply requirements are subject to the device label.
-
Connect class I electrical appliances to a power socket with protective earthing.
Introduction
1.1 Overview
Wireless WallSwitch is a power switch that can be used to remotely control
110–240 VAC power. The output terminal N is directly connected to the power
input terminal N, and the connection between the output terminal L and the
power input terminal L is controlled through opening and closing of the
built-in relay. The switch not only measures power consumption, but also comes
with protection against overvoltage, overload and overheating.
1.2 Technical Specifications
This section contains technical specifications of the wallswitch. Please refer
to the ones that correspond with your model.
Table 1-1 Technical specification
Type | Parameter | Description |
---|---|---|
Function | Indicator Light | 1 for multiple statuses (pairing, power status, and |
alarm)
Button| 1
Remote Update| Cloud update
Signal Strength| Detects signal strength
Wireless| Carrier Frequency| DHI-ARM7012- W2(868): 868.0 MHz–868.6 MHz| DHI-
ARM7012-W2: 433.1 MHz–434.6 MHz
Communication Distance| DHI-ARM7012- W2(868): Up to 1,200 m (3937.01 ft) in
an open space| DHI-ARM7012-W2: Up to 800 m (2624.67 ft) in an open space
Transmit Power| DHI-ARM7012- W2(868): Limit 25 mW| DHI-ARM7012-W2: Limit 15.8
mW
Communication Mechanism| Two-way
Encryption Mode| AES128
Frequency Hopping| Yes
General| Operating Temperature| –10 °C to +55 °C (+14 °F to +131 °F) (indoor)
Storage Temperature| –10 °C to +55 °C (+14 °F to +131 °F)
Operating Humidity| 10%–90% (RH)
Storage Humidity| 10%–90% (RH)
Power Supply| DHI-ARM7012-W2(868) and DHI-ARM7012-W2: 100–240 VAC, 50/60 Hz
Product Dimensions| 39 mm× 33 mm× 19 mm (1.54″ × 1.30″ × 0.75″)
Packaging Dimensions| 95 mm× 59.5 mm× 30.5 mm (3.74″ × 2.34″ × 1.20″)
Installation| Wall mount
Net Weight| 45 g (0.10 lb)
Gross Weight| 60 g (0.13 lb)
Certifications| DHI-ARM7012- W2(868):
CE| DHI-ARM7012-W2: CE, FCC
Casing Material| PC + ABS
Technical| Test Mode| Yes
Port| Relay Output| 1, NO/NC (100–240 VAC, Max 13A)
Checklist
Table 2-1 Checklist
No.| Item Name| Quantity| No.| Item Name|
Quantity
---|---|---|---|---|---
1| WallSwitch| 1| 4| Quick start guide| 1
2| Double-sided adhesive tape| 1| 5| Legal and regulatory information| 1
3| QR code| 1| –| –| –
Appearance
No. | Name | Description |
---|---|---|
1 | Antenna | Sends and receives signals. |
2 | Indicator | ● Press and hold the button for 2 seconds, and then the system |
enters pairing mode.
? Solid on for 1 second, then off for 0.5 seconds, and then solid on: Pairing
successful.
? Slowly flashes for 3 seconds, and then off: Pairing failed.
● After being powered on, press and hold the button for 2 seconds, and then
the device is off.
3| Power button
4| Wiring terminal| WallSwitch can be connected to 110–240 VAC power supply.
● IN: Power input terminal. It is directly connected to the power cable, and L
to live line, N to null line.
● OUT: Output terminal. It is used to connect to the external device, and L to
live line, N to null line.
Adding the Wireless WallSwitch to the Hub
Before you connect wallswitch to the hub, install the DMSS app to your phone. This manual uses iOS as an example.
- Make sure that the version of the DMSS app is 1.99.200 or later, and the hub is V1.001.0000004.0.R.221104 or later.
- Make sure that you have already created an account, and added the hub to DMSS.
- Make sure that the hub has a stable internet connection.
- Make sure that the hub is disarmed.
Step 1 | Go to the hub screen, and then tap Peripheral to add the wallswitch. |
---|---|
Step 2 | Tap + to scan the QR code at the bottom of the wallswitch, and then |
tap Next.
Step 3| Tap Next after the wallswitch has been found.
Step 4| Follow the on-screen instructions and switch the wallswitch to on, and
then tap Next.
Step 5| Wait for the pairing.
Step 6| Customize the name of the wallswitch, and select the area, and then
tap Completed.
Installation
Before installation, add the wallswitch to the hub and check the signal strength of the installation location. We recommend installing the wallswitch in a place with a signal strength of at least 2 bars.
5.1 Wiring
- WallSwitch can be connected to 110–240 VAC power supply.
- Based on its dimensions, you can install the wallswitch into the deep junction box, inside the electrical appliance enclosure, or in the distribution board.
5.2 Installing the Wireless WallSwitch
Configuration
You can view and edit general information of the wallswitch.
6.1 Viewing Status
On the hub screen, select a wallswitch from the peripheral list, and then you
can view the status of the wallswitch.
Table 6-1 Status
Parameter | Value |
---|---|
Temporary Deactivate | The status for whether the functions of the repeater are |
enabled or disabled.
Signal Strength| The signal strength between the hub and the wallswitch.
Input Voltage| Voltage value of the power input.
Output Status| Output status of the wallswitch.
Online Status| Online and offline status of the wallswitch.
Transmit through Repeater| The status of whether the wallswitch forwards its
messages to the hub through the repeater.
Program Version| The program version of the wallswitch.
6.2 Configuring the WallSwitch
On the hub screen, select a wallswitch from the peripheral list, and then tap
to configure the parameters of the wallswitch.
Table 6-2 Parameter description
Parameter | Description |
---|---|
Device Configuration | ● View wallswitch name, type, SN and device model. |
● Edit wallswitch name, and then tap Save to save configuration.
Area| Select the area to which the wallswitch is assigned.
Temporary Deactivate| Whether send sensor information to the alarm hub.
● Tap Enable, and then the wallswitch will send alarm messages to the hub.
Enable is set by default.
● Tap Disable, and then the wallswitch will not send alarm messages to the
hub.
Output Type| Select form Normally Open or Normally Closed. Normally Closed is
set by default.
Output Mode| Select form Steady State or Pulse. Pulse is set by default. When
selecting as Pulse, you can set pulse duration.
LED Indicator| LED Indicator is enabled by default.
If LED Indicator is disabled, the LED indicator will remain off regardless of
whether the wallswitch is functioning normally or not.
Scenario Setting| Configure scenarios to associate the wallswitch to perform
the corresponding action.
Click Create Scenario, you can select from Arming/Disarming Linkage Scenario,
Alarm Linkage Scenario, or Scheduled Linkage Scenario.
● Arming/Disarming Linkage Scenario: After customizing scenario name and
selecting linkage area, you can enable or disable Arming Linkage Output
Module, Disarming Linkage Output Module, or Home Mode Linkage Output Module.
● Alarm Linkage Scenario
● Scheduled Linkage Scenario: After customizing scenario name and enabling
Scheduled Linkage Output Module, you can set time and repeat periods.
Signal Strength Detection| Test the current signal strength.
Transit Power| ● Select from high, low, and automatic.
● The higher transmission power levels are, the further transmissions can
travel, but power consumption increases.
● If you select Low, the wallswitch will enter into reduced sensitivity mode.
● We recommend you selecting Low when installing the device to test the signal
strength of the installation location, and then adjusting to High or
Automatic.
● The indicator flashes when setting as Low.
Delete| Delete the wallswitch.
Go to the hub screen, select the wallswitch from the list, and then swipe left to delete it.
Appendix 1 Cybersecurity Recommendations
Cybersecurity is more than just a buzzword: it’s something that pertains to every device that is connected to the internet. IP video surveillance is not immune to cyber risks, but taking basic steps toward protecting and strengthening networks and networked appliances will make them less susceptible to attacks. Below are some tips and recommendations from Dahua on how to create a more secured security system.
Mandatory actions to be taken for basic device network security:
-
Use Strong Passwords
Please refer to the following suggestions to set passwords:
● The length should not be less than 8 characters.
● Include at least two types of characters; character types include upper and lower case letters, numbers and symbols.
● Do not contain the account name or the account name in reverse order.
● Do not use continuous characters, such as 123, abc, etc.
● Do not use overlapped characters, such as 111, aaa, etc. -
Update Firmware and Client Software in Time
● According to the standard procedure in Tech-industry, we recommend to keep your device (such as NVR, DVR, IP camera, etc.) firmware up-to-date to ensure the system is equipped with the latest security patches and fixes. When the device is connected to the public network, it is recommended to enable the “auto-check for updates” function to obtain timely information of firmware updates released by the manufacturer.
● We suggest that you download and use the latest version of client software.
Nice to have” recommendations to improve your device network security:
-
Physical Protection
We suggest that you perform physical protection to device, especially storage devices. For example, place the device in a special computer room and cabinet, and implement well-done access control permission and key management to prevent unauthorized personnel from carrying out physical contacts such as damaging hardware, unauthorized connection of removable device (such as USB flash disk, serial port), etc. -
Change Passwords Regularly
We suggest that you change passwords regularly to reduce the risk of being guessed or cracked. -
Set and Update Passwords Reset Information Timely
The device supports password reset function. Please set up related information for password reset in time, including the end user’s mailbox and password protection questions. If the information changes, please modify it in time. When setting password protection questions, it is suggested not to use those that can be easily guessed. -
Enable Account Lock
The account lock feature is enabled by default, and we recommend you to keep it on to guarantee the account security. If an attacker attempts to log in with the wrong password several times, the corresponding account and the source IP address will be locked. -
Change Default HTTP and Other Service Ports
We suggest you to change default HTTP and other service ports into any set of numbers between 1024–65535, reducing the risk of outsiders being able to guess which ports you are using. -
Enable HTTPS
We suggest you to enable HTTPS, so that you visit Web service through a secure communication channel. -
MAC Address Binding
We recommend you to bind the IP and MAC address of the gateway to the device, thus reducing the risk of ARP spoofing. -
Assign Accounts and Privileges Reasonably
According to business and management requirements, reasonably add users and assign a minimum set of permissions to them. -
Disable Unnecessary Services and Choose Secure Modes
If not needed, it is recommended to turn off some services such as SNMP, SMTP, UPnP, etc., to reduce risks.
If necessary, it is highly recommended that you use safe modes, including but not limited to the following services:
● SNMP: Choose SNMP v3, and set up strong encryption passwords and authentication passwords.
● SMTP: Choose TLS to access mailbox server.
● FTP: Choose SFTP, and set up strong passwords.
● AP hotspot: Choose WPA2-PSK encryption mode, and set up strong passwords. -
Audio and Video Encrypted Transmission
If your audio and video data contents are very important or sensitive, we recommend that you use encrypted transmission function, to reduce the risk of audio and video data being stolen during transmission.
Reminder: encrypted transmission will cause some loss in transmission efficiency. -
Secure Auditing
● Check online users: we suggest that you check online users regularly to see if the device is logged in without authorization.
● Check device log: By viewing the logs, you can know the IP addresses that were used to log in to your devices and their key operations. -
Network Log
Due to the limited storage capacity of the device, the stored log is limited. If you need to save the log for a long time, it is recommended that you enable the network log function to ensure that the critical logs are synchronized to the network log server for tracing. -
Construct a Safe Network Environment
In order to better ensure the safety of device and reduce potential cyber risks, we recommend:
● Disable the port mapping function of the router to avoid direct access to the intranet devices from external network.
● The network should be partitioned and isolated according to the actual network needs. If there are no communication requirements between two sub networks, it is suggested to use VLAN, network GAP and other technologies to partition the network, so as to achieve the network isolation effect.
● Establish the 802.1x access authentication system to reduce the risk of unauthorized access to private networks.
● Enable IP/MAC address filtering function to limit the range of hosts allowed to access the device.
More information
Please visit Dahua official website security emergency response center for
security announcements and the latest security recommendations.
ENABLING A SAFER SOCIETY AND SMARTER LIVING
ZHEJIANG DAHUA VISION TECHNOLOGY CO., LTD.
Address: No.1199 Bin’an Road, Binjiang District, Hangzhou, R R. China
Website: wwwdahuasecurity.com
Postcode: 310053
Email: overseas@dahuatoch.com
Fax: +86-571-87688815 I Tel: +86-571-87688883
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>