AutoTest AutoStop Maxi In Vehicle Brake Tester User Manual
- June 13, 2024
- autotest
Table of Contents
- UNPACKING AND FIRST TIME USE
- For Your Safety
- USE OF BATTERY CHARGER AND CARE OF BATTERY
- OPERATION
- TEST DATA STORAGE (OPTIONAL)
- CHECKING SENSORS AND OTHER FUNCTIONS
- CALIBRATION PROCEDURE
- TROUBLESHOOTING
- SPECIFICATIONS
- **AutoStop Maxi Brake Tester
- **Paper
- **Ribbon
- CHANGING PAPER
- CHANGING PRINTER RIBBON
- WARRANTY
- QUICK GUIDE
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
User Manual
Version 8.23
AUTOSTOP Maxi
In Vehicle Brake Tester
UNPACKING AND FIRST TIME USE
Congratulations on your choice of an AutoTest Brake Meter. Please take the time to read this User’s Manual before using the AutoStop Maxi Brake Meter in the field. Incorrect or inappropriate use of this instrument may void the warranty. Retain the packing materials for future shipping and transport of the unit for periodic calibration. Please complete the warranty registration card and post it to AutoTest Products Pty Ltd, alternatively visit our website www.autotest.net.au and complete your warranty registration online. Your warranty registration ensures that you are kept up to date on any software or hardware changes to your AutoStop Brake Tester. The packing box of your AutoStop Maxi should contain the following:
- AutoTest Brake Meter, Model AutoStop MAXI, complete with Pedal Sensor
- Long strap for restraining Brake Meter Unit Case
- Battery Charger
- User Manual
- Warranty Registration Card
- Calibration Certificate
- Interface Cable (download option only)
- Program Disc (download option only)
1.1 Activating your meter
Initially, each meter is locked prior to its shipment. So, before you can
perform any brake tests, you must first activate your meter.
Step 1: Switch on meter by holding down the On/Off button;
Step 2: Wait for the scrolling prompt “>Examiner ID? |(Y/N)”, then press
the “Yes” button.
Step 3: Next, a scrolling message “SENSOR CHECK – Please take foot off
pedal sensor…” should appear, press the “Yes” button to move onto the next
screen.
Step 4: At this point, you should see “Ready>” on the screen. Press “A”
to enter the activation menu.
Step 5: In the activation menu, press “Y” in response to the prompt
“>Meter is currently LOCKED. Activate meter? |(Y/N)”;
Step 6: Instructions on how to activate the meter should be scrolling
across the screen at this point. Press the “Yes” button to begin the
activation sequence.
Step 7 : At the prompt “Code: ”, enter the 5-digit serial number of your
brake meter (which is printed to the left of the On/Off button) and press
“Yes”;
Step 8 : Upon entering the correct serial number, you should see “Meter
Activated!” on the display. Now the Test menu is accessible from the “Ready>”
prompt by pressing “R”.
Note: The activation process is a one-time procedure, after which the
meter cannot be locked again.
1.2 Selecting Region
If you are using the brake meter in Queensland, New South Wales, or Victoria,
please set your region in the meter so that the unit settings and test
compliance code is automatically set for your state. To set the region, please
press “J” from “Ready>” screen. When the meter prompts for region (“Region:
“), use “U” and “D” keys to scroll through the list. When the desired region
appears on the screen, press “YES” or “Enter” to save it. Once the region is
set, the meter will automatically set the unit settings and the compliance
code.
For Your Safety
Read these simple guidelines. Not following them may be dangerous. Read the complete user guide. Further detailed information is given in this manual.
SWITCH ON SAFELY
Do not switch the device on when wireless device use is prohibited or when it
may cause interference or danger.
SWITCH OFF WHEN REFUELING
Do not use the device at a refuelling point. Do not use near fuel or
chemicals.
SWITCH OFF NEAR BLASTING
Follow any restrictions. Do not use the device where blasting is in progress.
USE SENSIBLY
Use only in the positions as explained in the product documentation.
QUALIFIED SERVICE
Only qualified personnel may install or repair this product.
ACCESSORIES AND BATTERIES
Use only approved accessories and batteries. Do not connect incompatible
products.
WATER-RESISTANCE
Your device is not water-resistant. Keep it dry.
CONNECTING TO OTHER DEVICES
When connecting to any other device, read its user’s guide for detailed safety
instructions. Do not connect incompatible products.
USE OF BATTERY CHARGER AND CARE OF BATTERY
AutoStop Maxi is fitted internally with a long-life 12volt, fully sealed,
rechargeable lead acid battery, which must be charged for up to 10 hours
before initial use. The battery charger input is located to the right of the
printer. With proper care and use, the battery
should last between two and five years.
It is recommended to recharge the battery nightly if the Brake Meter is used
regularly. Only an approved battery charger with the correct voltage, waveform
and terminal polarity should be used. The battery must never be allowed to
fully discharge as it will void the warranty.
The battery should always be recharged if the battery voltage falls below 12
volts (for more information see Section 6 “Checking Calibration”). As a guide,
if the Brake Meter is used for one to two tests per day, the battery should be
recharged weekly. If the Brake Meter is used more frequently, the battery
should be recharged daily.
The AutoStop Maxi is fitted with a low voltage cut-out switch in the circuitry
to protect the battery from excessive discharge. If the battery is allowed to
discharge to zero (0) volts, and left standing for a long period of time,
severe sulfation would occur, raising the internal resistance of the battery
to abnormally high levels. In such extreme cases, the battery may not accept a
charge. It is vital that the battery of the AutoStop Brake Meter is regularly
charged to prevent accidental battery damage.
OPERATION
4.1 Options: Changing & Viewing
To view or change items, ensure the Brake Tester is in the ready mode. “Ready>”
To: | Press | Screen Display |
---|---|---|
Select Region: VIC, NSW, QLD | From the Ready> position, | |
press “ J ” | Region: [VIC] [NSW] [QLD] |
When LCD displays “Region: __ ”, press “U” or “D” or “J” to select a different
region. Once the desired region has been selected, press YES or “ENTER” to
save it.
When the region has been changed, the brake meter will automatically update
the accelerometer unit and compliance code for the selected region.
Set Graph Mode| From the Ready> position, press “ X ”, then press “ G
“| Print Graph:
can be toggled between 1 and 0 by pressing “G” 1 = On – print the graph
with test 0 = Off – don’t print the raph with test.
Press “Enter” to return to Ready>
Change from Imperial to Metric| From the Ready> position, press “ X ”,
then press “ I “| Imperial:
can be toggled between 1 and 0 by pressing “I” 1 = Imperial, 0 = Metric Press “Enter” to return to Ready>
Set Acceleration unit| From the Ready> position, press “ X ”, then press “
A “| Accel:
Can be toggled between % and g by pressing “A” Press “Enter” to return to
Ready>
3.2 Test Conditions & Test Area
While the vertical angle of the Brake Meter will be automatically calculated
and compensated for prior to testing, the greatest accuracy will be obtained
when the Brake Meter is level to the surface of the road. Therefore, the area
used for the test should be as flat as possible. The head wind should be less
than 10kph.
3.3 Set-Up in Vehicle
AutoStop Maxi must be secure during the entire duration of the test.
Misalignment or movement can cause lower (worse) deceleration readings. This
could mean test failure if the brake performance is close to the required
limits. Secure Maxi in a level or horizontal position in the vehicle with the
lid open and facing forward. To prevent movement, use the long strap provided
by wrapping it around the brake tester and the passenger seat. Another method
is placing a sandbag behind Maxi, thus holding it against a firm surface.
Attach the pedal sensor to the brake pedal.
3.4 Running the Test
Note: The vehicle must be stationary (at a complete stop) prior to
commencement of the test. Ideal conditions are to test the vehicle at a
location where other vehicles are not present. However, if it is necessary to
use another area, such as a public road, only commence the test if no other
vehicles are in the area and there is no danger of an accident.
When the Brake Meter and the pedal sensor are both properly secured, turn the
unit on and follow the instructions in Section 3.6.
If an incorrect keystroke entry is pressed at any time, press the back-arrow
key to erase and then re-enter the correct keystrokes. The “beep” signal
indicates the key has been properly pressed and has registered on the display.
3.5 Special Characters
By using the following procedure you may obtain the following Special
Characters: To obtain the following characters, press and hold the “-“ key,
then press the listed character to obtain the special character.
Press “-“ and HOLD, then Press:| Displayed
Character| Press “-“ and HOLD, then Press:| Displayed
Character
---|---|---|---
A| !| N| .
B| “| O| /
C| #| P| (SPACE)
D| $| Q| !
E| %| R| “
F| &| S| #
G| ‘| T| $
H| (| U| %
I| )| V| &
J| | W| ‘
K| +| X| (
L| ,| Y| )
M| –| Z|
3.6 Test Instructions Summary
Step| Initial Screen Display| Instruction| Keys to Press|
Final Screen Display
---|---|---|---|---
1| Blank Screen| Switch On.| “ On/Off ”| AutoTest MAXI Brake
Test Unit
Software Version No.- Cal Due Date- Examiner ID? Y/N
2| Examiner ID? Y/N| To retain ID (identification of examiner)
as listed, press YES or “Y”
To alter the ID, press “N”| “ Y ” or “ N ”| If N is pressed the
meter will prompt New ID: (Step 3) , if Y is pressed the meter will
move on to Sensor Check (Step 4)
3| NEW
Examiner ID
| To change ID: Enter your personal Examiner ID (any alpha/numeric key entry
up to 19 digits).| Press the digits of your examiner ID (max 19 digits) then
press “ Yes ”.| Scrolling message regarding pedal sensor Auto Zero.
Sensor Check- Take Foot off Pedal Sensor and Press Any Key.
4| Sensor Check| Remove all pressure from the pedal sensor.
Upon pressing the enter key the unit measures and then compensates for the
slope of the vehicle and the 0 Newton point of the
pedal sensor.
| “ Yes ”| Ready >
5| Ready >| | “ R ”| Reg No?
6| Test with GPS? Y/N| | “ Y ” or “ N ”| If Y is
pressed, the meter will display “Acquiring position, please wait…” Once a
valid GPS position has been found, the meter will automatically continue to
Reg. NO? (Step 7).
If N is pressed then the meter will continue to Reg. NO? (Step 7)
and perform the brake test without GPS coordinates.
7| Reg. No?| Enter the vehicle ID Number. Up to 19 alpha/numeric
characters may be entered. Example VIN No. – Company ID
No. – License Plate No.| Press the digits of the vehicle registration, VIN, or
other designated numbers and then press “ Yes ”| Srvc/Emrg? S/E
8| Srvc/Emrg? S/E| Enter “ S ” if the service brakes are to
be tested, or enter “ E ” if the emergency brakes are to be tested.
Entering “ E ” bypasses the pedal sensor and no brake pedal pressure will
be recorded or printed. “ E ” is also used when testing parasitic braking
devices such as retarders. Note: An emergency test is similar to a
pendulumtype brake test.| Press “ S ” or “ E ”| Start, Abort? S/A
9| Start/Abort? S/A| Start or Abort the test. At this point
there should not be any load on the pedal sensor.
Pressing “ S “ will begin measurements and unit will await start
criteria’s such as deceleration and pedal pressure. Pressing “ A “ will
abort the test.| Press “ S ” or “ A ”| Prelude (if the S key is
pressed).
Ready > (if A key is pressed).
If the Brake tester is not sufficiently level after pressing “ S ”, the
following message will flash onto the screen, together with several warning
beeps: Slope too large, adjust unit. The LCD will then return to Ready>
---|---|---|---|---
10| Prelude| The Brake Tester is ready to start recording. If the
vehicle is at a stop, release the brake and gently accelerate the vehicle to
the required speed. Apply the brakes by pressing on the pedal sensor attached
to the brake pedal (or by using the emergency brake). For Service Brakes, the
test is triggered when the pedal sensor detects a load greater than 40 Newtons
followed by the vehicle decelerating by more than 0.1g. (Note: both must be
met). For emergency brakes, the test is triggered only by the vehicle
decelerating by more than 01.g. If the vehicle is in motion, you may gently
accelerate to the required speed and follow the same instructions as above.| |
Calculating …. If data logger is fitted screen will display Save Y/N?
Otherwise straight to Print Y/N?
11| Save Y/N| If the Datalogging option is not installed, this will
not appear, and the LCD will move directly to “ DUPLICATE Y/N ”. If the
Datalogging option is installed, you have the option to save the test by
pressing “ Y ”.| Press “ Y ” or “ N ”| If the memory is full, it
will not save and will display: “Not Enough Mem.”. If it is not full and
the “Y” is pressed, it will save test. If “N” is pressed, the test
will not be saved. In either case the LCD will show Print Y/N
12| Print Y/N| Allow the report to be printed.| Press “ Y ” or
“ N ”| If “ Y ” the LCD will show “ Official Copy”. The unit will
begin to print and LCD will then show Normalising as it calculates data
for graph presentation. As it prints the graph, the LCD will show Graph.
The LCD will now show Duplicate. If “N” the unit will return to Repeat
Y/N
3.6 Test Instructions Summary (cont’d)
13| Duplicate Y/N| If you require an additional copy of the test
Press “ Y ”. If one copy is sufficient then press “ N ”| Press “ Y
” or “ N ”| If “ Y ” the display will show “ Customer Copy ”, the
unit will begin to print and LCD will then show Normalising as it
calculates data for graph presentation. As it prints the graph the LCD will
show Graph The LCD will then show Repeat Y/N
---|---|---|---|---
14| Repeat? Y/N| Repeat the test by pressing “ Y ”, stop
testing and return to Ready mode by pressing “ N ”| Press “ Y ” or “
N ”| Svrc/Emrg? S/E if “ Y ” is pressed, Ready > if “ N ”
is pressed
TEST DATA STORAGE (OPTIONAL)
4.1 Using the Data Logger
The data logger has about 32K of memory available to store tests and allows
you to recall and either print or upload them to any IBM or IBM compatible
computer at a later time. Depending on the length of the tests, you can store
up to 30 tests.
Preliminary Function | To | Press | Screen Display |
---|
From the Ready> position, press “ L ”. To recall the data, press “ R
”| Print the Data| “ R ”| 1) XXXX ( Reg no # desired is displayed on the
LCD. Then Press “ C ” for an Customer Copy or “ O ” for a Official
Copy.
From the Ready> position, press “ L ”. To clear the data, press “ C ”|
Clear the Data Logger| “ C ”| Pressing “ C “ will show “Clear all
(Y/N) Pressing “ Y ” will clear Data Pressing “ N ” will not clear the
data.
From the Ready> position, press “ L ”. To display storage status
information, press “ I ”| Display Data Logger storage status information|
“ I ”| Tests saved: xx
Note: This screen displays the Number of tests stored in the Data Logger.
Press any key to go to the next screen.
Mem: xx % used
Note: Data Logger memory usage in percentage
4.2 Downloading Data
The downloadable model of the AutoStop Maxi is provided with a serial port to
attach to any IBM or IBM compatible computer with a spare COM port. An
interface cable and download software are required to download test results
from the Brake Meter. These are provided with the unit. The uploaded data,
formatted as a text file, can be imported into spreadsheet programs such as
Excel and Lotus for further detailed examination, or printed. Maxi Brake
Meters are shipped with download software (also available on the AutoTest
website) for PCs running Windows 95/98/2000. Version 7.0 and greater Brake
Meters require Version 1.4 of the download software. Earlier version Brake
Meters require Version 1.21 of the download software. You will receive the
appropriate software with the unit.
4.2.1 Download Instructions
If you have downloaded the software from the web, simply double-click on the
downloaded file to install the software. If you have received the software on
CD, insert the CD into your computer CD drive. If the setup program does not
run automatically, run the setup.exe program located on the CD to install the
software. After the program installation is finished, there will be two new
icons on your desktop.
Double-click on the ‘Maxi Data Logger’ icon to run the download software, or
doubleclick on the ‘Maxi Data Logger Data’ icon to access the directory
containing all the data files that have been downloaded from the Brake Meter.
Each time you download test data from a Brake Meter, two log-files are
automatically saved into this directory (folder). The filename is displayed in
the download software after a download, and is a combination of the Vehicle
Registration, Test Date and Test Time. The log-files can be re-opened and
printed at any time using the download software or opened in spreadsheet
programs such as Microsoft Excel.
The software is provided free of charge, however you must pay a license fee
for each Brake Meter that you wish to use with the software. For example, if
you own two brake meters and wish to use them both with the download software,
you will need to purchase a license code for each of these brake meters and
enter it into the software before you can download the test data. License
codes may be purchased from the AutoTest Products website,
http://www.autotest.net.au. Go to the ‘Buy Online’ section of the website
and enter your contact details to gain access to the Online Catalogue. Near
the bottom of the list is the option titled ‘Download Software License Code
for 1 Brake Meter’. Select 1 of these items, then proceed to Step 3 to enter
your Purchasing details. After making the purchase, you will be contacted via
email or phone and asked for a serial number, then supplied with the license
code for your Brake Meter.
Note that for a limited time these license codes may be available free of
charge, however you will still need to follow this procedure to receive a
license code for each Brake Meter.
Once you have purchased a license code, you must enter it into the download
software. To do this, load the software and click the button labelled ‘Help /
Add License’, then select the ‘Add a License’ tab at the top of the screen. On
the subsequent screen you will see a list of brake meters that have been
authorised for use on that computer. To add a brake meter to the list, enter
the serial number, along with the license code that you purchased for that
specific brake meter, then click the ‘Authorise’ button. If you entered the
license code correctly, the serial number of the brake meter will be added to
the list of authorised brake meters, and you will be able to download test
data from that brake meter.
Note that if you install the software on a different computer, or under a
different login name, you will need to re-enter the license code(s). Be sure
to save any purchased codes. AutoTest Products cannot be held responsible for
lost license codes.
Procedure for downloading tests to your PC:
Step 1: Connect your Brake Meter via the supplied RS232 cable to a spare
serial Port on your computer. If your brake meter is supplied with a USB
cable, connect one end of the cable to the PC and the other end to your Brake
Meter.
Step 2: On your PC, click the Download test(s) button, then select the
Com Port to which the Brake Meter is connected and click Next.
Step 3: Enter the serial number of the Brake Meter. (Note that you must
own a license for the Brake Meter and have entered the License Code in the
‘Add License’ section of this program – see below for more information). Then
click Next.
Step 4 : Enter any comments for this test. These will be saved in the
output file. Then click Next.
Step 5: When you are ready, click the Next button to put the PC into
Ready mode. The PC display will read ‘Turn on your Brake Meter now’.
Step 6 : Turn on your Maxi Brake Meter. After displaying the product
name, serial number and revision, the display will read ‘Connection..’ while
the Brake Meter communicates with the PC. If the connection is successful, the
Brake Meter will display ‘Data Logging…’ while the data is uploaded to the PC,
then will switch itself off.
Step 7: After the data is downloaded and displayed on the screen, click
the ‘More Data’ button to see the full test data, or select Print from the
toolbar to print the test and chart data to your printer.
Procedure for opening a previously saved log-file:
Step 1: Run the Maxi Data Logger software. Click the ‘Open test(s)’
button and use the mouse to select one or more tests to open. If you hold down
the CTRL key, you can select multiple tests.
Step 2: The log-files will be opened, and the first test will be
displayed on screen. Use the buttons and the list at the top of the screen to
view all the different tests or print the data.
CHECKING SENSORS AND OTHER FUNCTIONS
With the Brake Meter in Ready mode, the battery voltage, deceleration, pedal
force, date and time can be checked.
Note: None of these readings can be adjusted by the operator.
To: | Press | Screen Display |
---|---|---|
Check battery life | “ B ” | Bat. life: xxx % The Battery is considered flat |
when the percentage falls below 85%
Check calibration (Toggle between accelerometer & pedal sensor reading)| “
C ”
“ C ”
| Cal: x.xx g Acceleration reading
This should read close to 0.000 +/- 0.05 on a surface measured as being
horizontal and +/- 1.000 +/- 0.05 when vertical. Cal: xxx.x N Pedal Sensor
reading – this should be within 20N of zero when no load is applied.
Check the date| “ D ”| Date: dd mmm yy
Check the time| “ T ”| Time: hh:mm:ss
Note: The internal clock can be changed from Local Standard Time to Day Light
Savings. After seeing “T” you may toggle between Standard and Day Light time
by pressing “D”. Daylight Savings time is indicated with “ *** ”.
Check printer feed| “ P ”| Paper advances until any key is pressed
Contrast on LCD Display| “ O ”| BL= on or BL = Off Contrast X. Backlight
features are not standard (special order). The Contrast may be changed by
pressing “U” to go up or “D” to go down. Pressing “E” will exit this function.
Test Printer| “ N ”| Printing…**
The built-in printer will printout a demo page. This function could be used to diagnose the printer.
CALIBRATION PROCEDURE
The Brake Meter must be re-calibrated periodically. The reason for this is to
maintain creditability in tests and acceptance of data according to
international standards. Each time the unit is turned on, the LCD will show
the date that the re-calibration is due.
The calibration due date is also shown on all printouts and upload reports. At
the time the unit is due for re-calibration, testing will not be possible. The
LCD screen will show: “Calibration due! Contact your vendor for
recalibration.” Return Brake Meter to AutoTest Products (See Section 6.1).
6.1 Return of AutoStop Maxi for Calibration
6.1.1 Packaging
The Brake Meter should be packaged in the original shipping container.
However, where this container is not available, remember that you are shipping
an electronic instrument. Bubble pack or foam should surround the Brake Tester
and should be inserted into a sturdy cardboard box. Please ensure to return
your charger for inspection also.
6.1.2 Shipping
Labelling – A label noting “Electronic Device – Fragile” should be placed on
the box. Freight Carrier – Container should be sent “Freight Prepaid”.
AutoTest Products has no preference on freight carriers. However, the unit
should be forwarded by companies such as WARDS, IPEC, UPS, or Federal Express
if an expedient delivery is required.
Ship to: The Service Department, AutoTest Products Pty Ltd, 61-63 parsons St,
Kensington, Victoria 3031 Australia. Phone: +61 3 88403016.
6.1.3 Documentation
A copy of the purchase order for re-calibration and a packing slip must be
included with the shipment. It should note the Purchase Order Number, Date,
Serial Number and the address where the unit should be returned to.
TROUBLESHOOTING
Problem | Potential Cause & Action Necessary |
---|---|
Brake Meter will not turn on | Battery has discharged – charge battery for 12 |
to 16 hours. Battery charger has failed – check battery charger output with
multimeter, check condition of fittings.
Battery or internal electronics have failed – return unit for servicing.
Brake Meter does not record keypad input.| Battery discharged – refer above
Brake Meter turns itself off during use| Battery discharged – refer above
No printout| Out of paper = remove printer cover plate and check paper roll.
Refer Section 9
Printout illegible or hard to read| Printer ribbon needs replacing – refer
Section 10
“Time out “ displayed on printout| Unit not secured into position properly.
Foot has been lifted from pedal before vehicle has stopped.
“MEM FAILED” is displayed when Brake Meter is switched ON.| Internal flash
memory is not responding, or it is faulty. Switch off the unit and return it
for servicing.
“Format Mem? Y/N” is displayed when Brake Meter is switched ON.| Internal
flash memory is corrupt or unreadable. Press ‘N’ key to skip formatting.
Switch off the unit and return it for servicing. Note: if ‘Y’ key is pressed,
all existing data might get erased.
“Reset All? Y/N” displayed when unit is switched ON.| Clock memory is corrupt.
Clock battery is probably flat. Do NOT press ‘Y’. Press ‘N’ and switch off the
unit and return the unit for servicing.
“Accelerometer Fail!” displayed when unit is switched ON| Accelerometer chip
is faulty. Return the unit for servicing.
For other problems, contact AutoTest Products or any Authorised Service centre in Australia on (61 3) 9647 9797 or fax details of the problem to (61 3) 9646 3427. Repairs should only be done by an Authorised AutoTest Service Centre in order to ensure the Brake Tester retains its calibration. Refer to Section 11 regarding warranty. For instructions on returning products for calibration or servicing, see Section 6.1.
SPECIFICATIONS
**AutoStop Maxi Brake Tester
**
Battery
Charger Output
Pedal Sensor
Accelerometer| 12 V. 1.9 AH fully sealed lead acid rechargeable
14 V DC regulated, centre positive, 500 mA
Rated to less then +/- 1N over 0 to 1000N
Rated to less than + /- 2% over -2.5 to 2.5g
---|---
**Paper
**
Wood-free paper
Max roll diameter
Width
Thickness
Basic Weight| 50mm
44.5mm (+/-0.5mm)
0.06mm (+/-0.001mm)
52.3gms (14lb/500 sheet 17”x22”)
---|---
**Ribbon
**
Epson type ERC-05
Ribbon Life
Print Speed
Colour Dimensions| Equivalent to 2 paper rolls
1.0 line/sec
Purple or Black
approx. 74mm (w) x 25mm (d) x 7mm (h)
---|---
Note: The use of proper paper is very important to the operation of the printer. Use of nonstandard paper will jam the printer or wear the print head and will void the warranty. Paper and ribbons are available from AutoTest Products as a kit, containing 2 rolls of paper and one ribbon. The replacement of any other components must be carried out by AutoTest Products or an Authorised AutoTest Service Centre.
CHANGING PAPER
-
Switch the Brake Meter “On” and enter Examiner I.D. to get to the “Ready” mode.
-
Remove the printer cover plate on the top of the keypad by inserting a screwdriver in the buttons and twisting through 90 degrees.
-
Lift out printer cover plate, empty paper roll.
-
Tear off any remaining paper. With the Brake Meter turned on and at the “Ready” mode, press the “P” key on the keyboard to feed any remaining paper through the printer.
-
Press any key to halt paper feed.
-
Remove the old paper core and spindle by gently springing apart the sides of the paper holder. Discard the paper core.
-
Prepare a clean starting edge on the new roll by cutting off the top of the paper.
-
Mount the paper roll on the spindle and load into the paper holder in the orientation shown on the printer cover.
-
Feed the edge of the paper into the printer, press the “P” key on the keypad (at the Ready mode) to feed paper through the printer. Feed 50 to 75mm through the printer.
-
Press any key to halt paper feed.
-
Wind up any slack in the paper roll, replace the printer cover plate fitted with the new paper roll and press the hold-down buttons home.
Note: The buttons must be correctly aligned before they will click home. -
Press “Off” when complete
-
It is important that the paper is of an approved type. Use of an unapproved paper will damage the printer mechanism and void warranty.
CHANGING PRINTER RIBBON
- It is recommended that a new printer ribbon be fitted for every two paper rolls consumed.
- Remove the printer cover plate by following steps 1-3 for changing the paper roll.
- Gently push down on the right-hand side of the printer ribbon (the word PUSH is embossed on the ribbon cartridge. The left side will flip up and the ribbon may be removed from the printer.
- Replace the ribbon in the same orientation; with the ribbon facing towards the keypad and the word “PUSH” and “EJECT” on the right-hand side. Locate the lefthand side of the ribbon cartridge in position first; with the ribbon fitting between the metal plate and paper feed guide.
- Wind up any slack in the paper roll, replace the printer cover plate fitted with the new paper roll and press the hold-down buttons home. Note: The buttons must be correctly aligned before they will click home.
- Press “Off” when complete.
WARRANTY
AutoTest Products Pty Ltd or any Authorised AutoTest Service Centre warrants
this product against defects in material and workmanship for a period of 12
months from the original date of purchase. This warranty applies only to
products and components supplied by AutoTest Products which can be identified
by the trade name or logo affixed to them or by other documents. AutoTest
Products does not warrant any products not supplied by AutoTest Products.
Note: The use of proper paper is very important to the operation of the
printer. Use of nonstandard paper will jam the printer and/or wear the print
head. Use of non-standard paper will void the warranty. Paper and printer
ribbon cartridge are available from AutoTest Products.
During the warranty period, AutoTest Products or any Authorised Service Centre
will repair (or at its option replace) any defective component(s) without
charge for parts or labour, provided the product is freight prepaid to an
authorised AutoTest Service Centre. Transit insurance and return freight will
be at the owner’s expense.
To obtain calibration, warranty or non-warranty service, ship the product,
freight and insurance prepaid to your nearest AutoTest Service Centre. Attach
to the product your name, address, contact phone numbers, description of the
problem and if a warranty claim, proof of purchase (dated sales receipt or
invoice).
AutoTest Products or any Authorised AutoTest Service Centre reserves the right
to refuse warranty repair if accident, abuse, misuse or misapplication has
damaged the product. In transit or because of service or modification by other
than an Authorised Service Centre, nor are any other warranties expressed or
implied, including any regarding merchantability or fitness for any other
particular purpose.
AutoTest Products or any Authorised Service Centre is not responsible for
incidental or consequential damages resulting from the breach of any express
or implied warranty, including damage to property and, to the extent permitted
by law, damages for personal injury.
QUICK GUIDE
After Unpacking
Charge the battery for 10 hours before initial use. The battery charger input
is located to the right of the printer. With proper care and use, the battery
should last between two and five years. It is recommended to recharge the
battery nightly if the AutoStop Brake Tester is used regularly. Only an
approved battery charger with the correct voltage, waveform and terminal
polarity should be used. The battery must never be allowed to fully discharge
as it will void the warranty.
Set-Up & Testing
-
Secure AutoStop Maxi in vehicle and attach pedal sensor to brake pedal. This will vary from vehicle to vehicle; a mounting bracket or straps may be used.
-
Press “ON”.
-
Enter Examiner ID and press “Yes”.
-
Remove pressure from pedal sensor. Processor measures zero level of the pedal sensor.
-
Press “Yes” again.
-
Mistakes may be corrected by using the “<” or backspace key.
-
At the “Ready>” prompt, press “R” to run test. Enter the vehicle registration number (or VIN number) and press “Yes”.
-
Srvc/Emrg? S/E. Select Service (S) or Emergency (E) test.
-
Ensure it is safe to run the test.
-
Before starting or repeating the test, remove foot from pedal sensor and brake pedal.
-
Press “S” to start (or “A” to abort).
-
Accelerate to speed and stop when safe.
-
Press “Y” to save or “N” to not save the results (if Brake Tester has data logging option).
-
Press “Y” to print or “N” to skip printing a duplicate.
-
Press “Y” to repeat test, “N” to end test.
-
Press “OFF”.
Change Paper
- Remove printer cover from panel.
- Remove paper roll spindle from cradle.
- Load new roll (see ‘Paper Specifications’ regarding special paper).
- Press “ON”.
- Enter Examiner ID and press “Yes”.
- Press “P” to feed paper through printer.
- Press any key to halt paper feed
- Replace paper roll assembly and printer cover.
- Press “OFF”.
NOTES:
AUTOTEST Products Pty Ltd
61-63 Parsons St Kensington VIC 3031 Australia
Phone: (+61 3) 8840 3000 Service: (+61 3) 8840 3016
Email: service@autotest.net.au
Email: sales@autotest.net.au
Sales:(+61 3) 8840 3017
Fax: (+61 3) 8840 3099
info@autotest.net.au
www.autotest.net.au
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>