Rasonic RPD-YS27GU Compressor Type Dehumidifier Instruction Manual
- June 12, 2024
- Rasonic
Table of Contents
RPD-YS27GU Compressor Type Dehumidifier
Product Information
Product Name: RPD-YS27GU
Intended Use: Household use only
Specifications:
- Dimensions: 30cm
- Weight: 15.8kg
- Power Supply: 220-240V~ 50Hz
- Power Consumption: 265W
- Refrigerant: R134a 350g
- Capacity: 6L
Product Usage Instructions
Important Safety Instructions:
-
WARNING: Improper handling may lead to serious
injury or even death. -
CAUTION: Improper handling may lead to injury
or property damage.
General Guidelines:
-
Read and follow all instructions in the user manual.
-
Ensure the product is used for household purposes only.
-
Keep the product away from flames and flammable gas.
-
Do not modify or disassemble the unit by yourself. Contact Shun
Hing Electric Service Centre Limited for check and repair if any
part is damaged or malfunctioning. -
Disconnect power cord before cleaning, maintenance, or moving
the unit. -
Do not pull out the power plug with wet hands.
-
Do not use the unit when the power supply cord or the power
plug is damaged or loosely plugged into an electrical socket.
Specific Instructions:
-
Insert the power plug into the electrical socket
completely. -
Do not damage, remodel, bend unreasonably, pull, twist, or
place heavy objects on the power cord. -
Use only a 220V-240V power supply.
-
Periodically clean the dust and dirt from the plug with a dry
cloth. -
Do not use the unit on an uneven floor.
-
Do not unplug roughly. Pulling on the power supply cord may
cause fire, short circuit, or electric shock. -
Avoid using the unit near volatile substances such as gasoline,
solvent, or insecticide.
Please refer to the user manual for additional instructions and
safety information.
For household use only.
R PD -YS27GU
Some figure in this manual may not match the real product , just for reference
only.
30cm
88
3
()
3
/
3
/
/
/
/
/
/
/
LCD
,,LCD10 LCD H RH75%LCD H RH65%LCD H RH65%LCD
LCD
H 75%RHLCD
RH80%[]HiRH45%Lo
RH80%
RH45%
[] [] [] 3[ /]
5
RH75%LCD()
ECO
3
RH50% ()
EC O
3
ECO50%RH~60%RH 45%RH
RH50%
3
8
6
4
60%
65%
70%
40%
45%
55%
3
3
45
(0~45)
(45~90)
(0~90)
:
OFF 1hr 2hrs 3hrs 4hrs 5hrs…10hrs 11hrs
12hrs
LCD
Er Er (Er) 10()
7
3 3
3
3
8
1~ 12
LCD
3
E C O
60%~50%
( 6)5
9
10
11
12
:
13
14
RPD-YS27GU
220-240V~ 50Hz
14.9
26.7 RH60%
27
30 RH80%
265W
1.25A
R134a 350g
6L 5L 15.8kg
600
370
263
3 :28612767
15
6
16
Read all instructions carefully before using.Hazards that may cause
death,injury or property damages from misuse. Be sure of correct voltage is
used and plag is well plugged in socket. Remove plug from socket for cleaning
maintenance or storage. To avoid dangerous,please do not cover inlet/outlet
with cloth or curtain. Poor ventilation may cause fire. Please do not operate
dehumidifier in a closed or narrow space. (when the dehumidifier is used in
the clost,please keep the door of closet open and keep clothing away from air
inlet and outlet at least 30 cm, to avoid obstruction of air inlet and
outlet.) A closed or narrow space may case circumstance temperature raised up
ad damage machine. Please do not insert finger , nail or metal rod in the
unit. Do not stand on or lean against the unit.This may cause it to full
over,resulting in personal injury. Before moving the unit, please empty water
and remove plug from socket. To avoid short circuit or leakage, please don’t
spray water on the unit. Never immerse the body , power cord and plug in water
or let them wet, in order to avoid functional damage to the appliance electric
shock. Do not spray solvent or flammable liquid. Do not lay down the unit as
which may damage the unit and cause noisy. When the unit is out of order
please do not intend to disassemble the unit. Avoid leaving an operating
dehumidifier unattended. This appliance can be used by children aged from 8
years and above and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have been given
supervision or instruction concerning use of the appliance in a safe way and
understand the hazards involved. Children shall not play the appliance.
Cleaning and user maintenance shall not be made by children without
supervision.
17
To prevent users and others injury or damage, please follow all the
instructions below Ignoring the symbols incorrect operation can result in harm
or level of damage, described in the following two categories.
WARNING Improper handling may lead to serious injury or even death.
CAUTION Improper handling may lead to injury or property damage.
CAUTION
The product designed useful life is ten years.
If product exceeds useful life, parts may deteriorated, dust accumulation or
lack of maintenance, in some circumstances cause fire.
This icon used in this manual the following.
Never do
Caution or Notice
Be sure to follow the instructions
Disconnect the power plug
Do not wet
Do not handle with wet hands
Keep away from flames
Prohibit disassembling
Do not modify or disassemble the unit by yourself .
Improper handling may lead to fire, short circuit,electric shocks or injury.
Please contact Shun Hing Electric Service Centre Limited for check and repair
if any part is damaged or malfunction.
Disconnect power cord before cleaning, maintenance or moving the unit.
Do not pull out the power plug with wet hand, electric shocks may occur.
Do not use the unit when the power supply cord or the power plug is damaged or
plugged loosely into an electrical socket.
A damaged or loose cord or plug may lead to fire because of a electric shock
or short circuit.Periodically clean the dust and dirt from the plug with a dry
cloth.
Insert the power plug into the electrical socket completely.
Incomplete connections may lead to electric shock or fire because of
overheating.
WARNING
Do not damage, remodel, bend unreasonably, pull, twist or place heavy objects
on power cord.
Using damaged power cord, fire or electric shocks may occur.
Use only a 220V-240V power supply.
Other power supplies may lead to fire or electric shock.
Accumulation of dust and foreign objects may cause insulation failure and lead
to fire
CAUTION
Do not use the unit on an uneven floor.
18
To prevent users and others injury or damage, please follow all the instructions below Ignoring the symbols incorrect operation can result in harm or level of damage, described in the following two categories.
CAUTION
Do not unplug roughly.
Pulling on the power supply cord may cause fire, short circuit or electric
shock.
Do not use unit near flammable gas.
If flammable gas permeates the surrounding space, it may cause fire.
Danger !
Do not spray volatile substances ,i.e., gasoline, solvent, insecticide.
It may cause fire or electric shock.
Do not use the unit anywhere there is airborne oil such as machine oil.
Airborne oil may lead to cracking or ignition.
airborne oil
Before long period of disuse,disconnect the Do not use the unit in the place
power plug from the electrical socket.
of water may splash onto the unit
Degraded insulation may lead to electric shock,current leaks or fire. The dehumidifier must not be left unattended while it connected to the supply cord.
Avoid the product damage or electric shock.
Do not use an extension power cord.
It may result in overheating and fire.
NO!
Do not use damaged power cord or plug.
It may cause electric shock, short-circuit or fire.
Danger !
Do not pull out the power plug with wet hands.
Electric shocks may occur.
NO!
Do not trample on the cord as this may cause damage.
If the power supply cord is damaged,
it must be replaced by the manufacturer,
dealer or qualified persons in order to avoid hazard.
Danger !
19
Louver
Air outlet
Front plate Outfall
Tank cover Water tank
Control panel Air inlet
Handles
(left and right
Polyfoam floater
(Inside the water tank)
Cord holder
Tank handle Power cord
Handle
Drain hole
(Continuously drainage)
Power plug
3
20
Key Lock
Water tank full indicator Defrost indicator Anti-mold indicator
3
Air clean button Louver setting Mode button
Turns the Power ON/OFF
Negative ion button TIMER Humidity selection Dry clothes
Note
Current Humidity Display
If ambient humidity is greater than RH80% [Current humidity display] will
display Hi, if less than RH45% will display Lo
Water Tank Full indicator
RH
RH
Water Full Tank indicator light up, operation will stop automatically if tank is not emptied or
it is not in the proper place.
Defrost indicator
When the Defrost indicator light up, this indicates the unit is in the defrost mode.
(Unit operates at high speed with compressor off)
Anti-mold indicator
When Anti mold indicator light up, unit will operate at high speed fan
automatically for 3 minutes; press “Power ON/OFF” button can stop function
immediately.
21
LCD
All indicators on the LCD Panel shown below: Frame appears around selected
mode Press any button when the power is on, selected function will be
displayed. Meanwhile, the LCD backlight lights up, and the backlight will
automatically go off after 10 seconds.
Key Lock
ION
Airflow
Hi
indicators Lo
Humidity indicator (Current)- indicates the current humidity (Selection)- indicates set humidity level The humidity setting range from 40% ~ 70%
Swing Monitor
Mode indicators Indicates the dehumidify mode
Drying clothes indicators
Timer display
Display the time set for auto shutdown
Quiet Normal Speed
Louver Indicator This indicates the range of louver swing
LCD Backlight indicator different ambient humidity and unit condition: 1. Deep Blue: Ambient humidity is greater than RH75% 2. Light blue: Ambient humidity is greater than or equal to RH65% 3. Brightening: Ambient humidity is less than RH65% 4. Deep blue backlight keep flashing: When the unit is tipped over, water tank is full or not place in the right position. 5. High ambient humidity indicator: During standby, when unit detects ambient humidity more than 75%, deep blue backlight will light up. Press “Humidity button” can turn off the indicator light.
22
Be sure of correct voltage is used and plug is well plugged in socket. The unit automatically detects ambient humidity, when room humidity more than RH75% and LCD backlight will light up.(Deep Blue)
Press “/(ON/OFF)” button to start the unit and the Power and Humidity indicator light turn on. Unit operates at “ECO(ECO)” mode automatically set as below situation:
3
Unit operates at “ECO(ECO)” , according to room humidity. When room humidity
is over RH50%, compressor will turn on in 3 minutes after the”/(ON/OFF)”
button is pressed .
(When the plug is connected to power more than three minutes, the compressor
will start immediately)
You can adjust the dehumidification mode according to the actual situation,
press “(Mode)” button to switch to other function:
ECO(ECO) (Dry) (Comfort) (Continue)
3
ECO(ECO) : Select “ECO”(ECO) mode, unit operates automatically with low energy
consumption and keep humidity level between 50% ~ 60% ; or operates at low
speed(compressor is off) when humidity is less then 45%.
(Dry):Unit operates continually to maintain ambient humidity level under 50%.
(Comfort):Unit operates continuously to keep ambient humidity at a suitable
level for human body.
(Continue):Unit operates continuously dehumidification regardless of the
ambient humidity level until water tank full or Power button is pressed.
You can adjust the “(Dry clothes)”mode by press”(Dry clothes)”button to switch to other function: (Standard) (Quiet) (Speed)
3
The unit turn on/off the fan and compressor automatically according to the
ambient humidity and temperature.
(Standard):Select”(Standard)” mode, unit operates at middle speed fan to dry
clothes in enegry saving. (Quiet):Select”(Quiet)” mode, unit operates at low
speed fan and suitable for night time or sleeping. (Speed):Select”(Speed)”
mode, unit operates at high speed fan to dry clothes quickly.
The unit operates for 8 hours and automatically switches off. Restart the unit
if it turns off before the laundry dries.
23
Humidity Selection
Pressing the button once displays the set humidity level with the
(Selection)indicator. After 4 seconds,
the display returns to the current humidity display and shows the word (Current)
60% 65% 70% 40% 45% 55%
3
Humidity sensor detects the ambient level and keeps indoor humidity at the set humidity.
Select “(Air Clean)” mode, press to select low or high air volume, and compressor
is off.
(Low speed)
(High speed)
3
Louver Setting
When power is on, the direction of the louver is inclined at 45 degree. Press “(Louver )”button to select
the louver swing range.
Down
Up
Wide
Swinging stops
(Degree 0~45 °) (Degree 45 °~90 °) (Degree 0~90 °)
Note:Do not move the louver while swinging operation is in progress.
Press “(Timer)” button to select the shutdown timer.
OFF 1 hr 2 hrs 3hrs 4 hrs 5hrs….10hrs 11hrs 12hrs
After timer is set, unit will display time remaining.
When unit is tipped over, operation will stop automatically, Humidity
Indicator is flashing and alarm.
1. Disconnect the power cord 2. Place the unit in an upright position on a
stable, flat surface 3. Insert the power cord again and restart the unit
(Compressor starts once the plug plugged in the socket after 10 minutes)
24
Key Lock setting
During standby or operation, please press “(Key Lock)” button for 3 seconds to
active the Key Lock. When the LCD Lock lights up, the unit can’t be switched
off or on and all functions are not available until the key lock has been
released.
Key Lock off To release the key lock by pressing “(Key Lock)” button again for
3 seconds. The key lock lamp goes out.
3
Air purifying function
During operation, press “(ION)” button to turn on and off the negative ion.
When LED is on, the unit releases negative ions to purify the air.
3
The unit will be operated in the range 5~35
25
C
3
3 louver angle for selection.
ECO mode Auto humidity setting to keep humity level between 50~60%.
26
When water tank is full(5L), the water tank full indicator will light up and
flash, the unit will stop operation. Please empty water tank for operation
resume.
Don’t immediately remove water tank when full water LED light up, until few
minutes later and no water attached on the cooling system. Press power off and
empty water before moving the unit to avoid water spillage on floor or
penetrate to inner part. The dehumidified water on the evaporator is likely to
frost at low temperature, which may cause the dehumidification water to not
drip inside the water tank, it is not a malfunction. Water drain hole at
middle plate must be cleaned to avoid water blockage. Please do not take out
or throw away the polyfoam floater in this water tank, otherwise it will cause
auto-stop function failure.
27
Continuous Drainage: Caution: Do not drain water continuously if there is a
possibility unattended for long periods.
28
Dust or dirt clogged filter will result in reduced dehumidification efficiency
and may cause failure. Clean once every 2 weeks.
(Dry the filter before reinstall)
29
Main unit Using a soft cloth moistened with warm water (below 40 degree) or
mild detergent to wipe the unit. Clean with neutral detergent and wipe with a
wet cloth.
. Cover with plastic bag and place the unit under a area not shone by sun and
good ventilation.
30
Remove air inlet cover
31
RPD-YS27GU
Rated Voltage/Frequency Rated Capacity(L/Day)
220-240V~ 50Hz
14.9L (26.7 RH60%) 27L (30 RH80%)
Rated Power Rated current
265W 1.25A
Refrigerant & Amount Tank Capacity
R134a,350g 6L (5L Shut off)
Net Weight
15.8 kg
Dimension(mm)
600H x 370W x 263D(mm )
3.An electronic copy of the user manual can be emailed to the customer if
necessary,please call Shun Hing Electric Works and Engineering
Co.,Ltd:28612767
32
Trouble shooting and Emergercy Handling
Before requesting for repairs, check the following points.
6
If any abnormalities, please turn off the unit and disconnect the power cord
If the above solution can not fix the problem, please contact Shun Hing
Electric Service Centre Limited for check and repair.
33
211
(852) 2406 5666
(852) 2408 0316
/ (852) 2406 5666
www.shesc.com
11th Floor, Shun Hing Centre, 2 Shing Yiu Street, Kwai Chung, New Territories, Hong Kong
Tel : (852) 2406 5666
Fax : (852) 2408 0316
Consumables/Accessories Sales Hotline : (852) 2406 5666
Website : www.shesc.com
21
(852) 2406 5439
(852) 2408 1389
193~1995I
(853) 2836 2928
(853) 2833 6405
: www.shesc.com
1 st Floor, Shun Hing Centre, 2 Shing Yiu Street, Kwai Chung, New Territories, Hong Kong
(852) 2406 5439
(852) 2408 1389
Avenida de Venceslau de Morais, No. 193~199, 5 andar – I, Edf. Industrial Nam Leng, Macau
(853) 2836 2928
(853) 2833 6405
www.shesc.com
RPD/YS/2210
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>