Rasonic RPD-YS27GU Compressor Type Dehumidifier Instruction Manual

June 12, 2024
Rasonic

RPD-YS27GU Compressor Type Dehumidifier

Product Information

Product Name: RPD-YS27GU

Intended Use: Household use only

Specifications:

  • Dimensions: 30cm
  • Weight: 15.8kg
  • Power Supply: 220-240V~ 50Hz
  • Power Consumption: 265W
  • Refrigerant: R134a 350g
  • Capacity: 6L

Product Usage Instructions

Important Safety Instructions:

  • WARNING: Improper handling may lead to serious
    injury or even death.

  • CAUTION: Improper handling may lead to injury
    or property damage.

General Guidelines:

  • Read and follow all instructions in the user manual.

  • Ensure the product is used for household purposes only.

  • Keep the product away from flames and flammable gas.

  • Do not modify or disassemble the unit by yourself. Contact Shun
    Hing Electric Service Centre Limited for check and repair if any
    part is damaged or malfunctioning.

  • Disconnect power cord before cleaning, maintenance, or moving
    the unit.

  • Do not pull out the power plug with wet hands.

  • Do not use the unit when the power supply cord or the power
    plug is damaged or loosely plugged into an electrical socket.

Specific Instructions:

  • Insert the power plug into the electrical socket
    completely.

  • Do not damage, remodel, bend unreasonably, pull, twist, or
    place heavy objects on the power cord.

  • Use only a 220V-240V power supply.

  • Periodically clean the dust and dirt from the plug with a dry
    cloth.

  • Do not use the unit on an uneven floor.

  • Do not unplug roughly. Pulling on the power supply cord may
    cause fire, short circuit, or electric shock.

  • Avoid using the unit near volatile substances such as gasoline,
    solvent, or insecticide.

Please refer to the user manual for additional instructions and
safety information.

For household use only.
R PD -YS27GU
Some figure in this manual may not match the real product , just for reference only.

30cm

88

3

()

3

/

3

/

/

/

/

/

/

/

LCD
,,LCD10 LCD H RH75%LCD H RH65%LCD H RH65%LCD

LCD

H 75%RHLCD

RH80%[]HiRH45%Lo

RH80%

RH45%

[] [] [] 3[ /]

5

RH75%LCD()

ECO

3

RH50% ()

EC O

3

ECO50%RH~60%RH 45%RH
RH50%

3

8

6

4

60%

65%

70%

40%

45%

55%

3

3

45

(0~45)

(45~90)

(0~90)

:

OFF 1hr 2hrs 3hrs 4hrs 5hrs…10hrs 11hrs

12hrs

LCD

Er Er (Er) 10()

7

3 3

3

3

8

1~ 12

LCD

3

E C O
60%~50%

( 6)5

9

10

11

12

:
13

14

RPD-YS27GU

220-240V~ 50Hz

14.9

26.7 RH60%

27

30 RH80%

265W

1.25A

R134a 350g

6L 5L 15.8kg

600

370

263

3 :28612767
15

6
16

Read all instructions carefully before using.Hazards that may cause death,injury or property damages from misuse. Be sure of correct voltage is used and plag is well plugged in socket. Remove plug from socket for cleaning maintenance or storage. To avoid dangerous,please do not cover inlet/outlet with cloth or curtain. Poor ventilation may cause fire. Please do not operate dehumidifier in a closed or narrow space. (when the dehumidifier is used in the clost,please keep the door of closet open and keep clothing away from air inlet and outlet at least 30 cm, to avoid obstruction of air inlet and outlet.) A closed or narrow space may case circumstance temperature raised up ad damage machine. Please do not insert finger , nail or metal rod in the unit. Do not stand on or lean against the unit.This may cause it to full over,resulting in personal injury. Before moving the unit, please empty water and remove plug from socket. To avoid short circuit or leakage, please don’t spray water on the unit. Never immerse the body , power cord and plug in water or let them wet, in order to avoid functional damage to the appliance electric shock. Do not spray solvent or flammable liquid. Do not lay down the unit as which may damage the unit and cause noisy. When the unit is out of order please do not intend to disassemble the unit. Avoid leaving an operating dehumidifier unattended. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play the appliance. Cleaning and user maintenance shall not be made by children without supervision.
17

To prevent users and others injury or damage, please follow all the instructions below Ignoring the symbols incorrect operation can result in harm or level of damage, described in the following two categories.
WARNING Improper handling may lead to serious injury or even death.
CAUTION Improper handling may lead to injury or property damage.

CAUTION

The product designed useful life is ten years.
If product exceeds useful life, parts may deteriorated, dust accumulation or lack of maintenance, in some circumstances cause fire.

This icon used in this manual the following.

Never do
Caution or Notice

Be sure to follow the instructions
Disconnect the power plug

Do not wet
Do not handle with wet hands

Keep away from flames
Prohibit disassembling

Do not modify or disassemble the unit by yourself .
Improper handling may lead to fire, short circuit,electric shocks or injury. Please contact Shun Hing Electric Service Centre Limited for check and repair if any part is damaged or malfunction.
Disconnect power cord before cleaning, maintenance or moving the unit.
Do not pull out the power plug with wet hand, electric shocks may occur.
Do not use the unit when the power supply cord or the power plug is damaged or plugged loosely into an electrical socket.
A damaged or loose cord or plug may lead to fire because of a electric shock or short circuit.Periodically clean the dust and dirt from the plug with a dry cloth.
Insert the power plug into the electrical socket completely.
Incomplete connections may lead to electric shock or fire because of overheating.

WARNING
Do not damage, remodel, bend unreasonably, pull, twist or place heavy objects on power cord.
Using damaged power cord, fire or electric shocks may occur.
Use only a 220V-240V power supply.
Other power supplies may lead to fire or electric shock.
Accumulation of dust and foreign objects may cause insulation failure and lead to fire
CAUTION
Do not use the unit on an uneven floor.

18

To prevent users and others injury or damage, please follow all the instructions below Ignoring the symbols incorrect operation can result in harm or level of damage, described in the following two categories.

CAUTION

Do not unplug roughly.
Pulling on the power supply cord may cause fire, short circuit or electric shock.

Do not use unit near flammable gas.
If flammable gas permeates the surrounding space, it may cause fire.

Danger !

Do not spray volatile substances ,i.e., gasoline, solvent, insecticide.
It may cause fire or electric shock.

Do not use the unit anywhere there is airborne oil such as machine oil.
Airborne oil may lead to cracking or ignition.

airborne oil

Before long period of disuse,disconnect the Do not use the unit in the place

power plug from the electrical socket.

of water may splash onto the unit

Degraded insulation may lead to electric shock,current leaks or fire. The dehumidifier must not be left unattended while it connected to the supply cord.

Avoid the product damage or electric shock.

Do not use an extension power cord.
It may result in overheating and fire.
NO!

Do not use damaged power cord or plug.
It may cause electric shock, short-circuit or fire.
Danger !

Do not pull out the power plug with wet hands.
Electric shocks may occur.
NO!

Do not trample on the cord as this may cause damage.

If the power supply cord is damaged,

it must be replaced by the manufacturer,

dealer or qualified persons in order to avoid hazard.

Danger !

19

Louver
Air outlet
Front plate Outfall
Tank cover Water tank

Control panel Air inlet
Handles
(left and right
Polyfoam floater
(Inside the water tank)
Cord holder
Tank handle Power cord

Handle
Drain hole
(Continuously drainage)
Power plug

3

20

Key Lock

Water tank full indicator Defrost indicator Anti-mold indicator

3

Air clean button Louver setting Mode button

Turns the Power ON/OFF

Negative ion button TIMER Humidity selection Dry clothes

Note

Current Humidity Display
If ambient humidity is greater than RH80% [Current humidity display] will display Hi, if less than RH45% will display Lo

Water Tank Full indicator

RH

RH

Water Full Tank indicator light up, operation will stop automatically if tank is not emptied or

it is not in the proper place.

Defrost indicator

When the Defrost indicator light up, this indicates the unit is in the defrost mode.

(Unit operates at high speed with compressor off)

Anti-mold indicator
When Anti mold indicator light up, unit will operate at high speed fan automatically for 3 minutes; press “Power ON/OFF” button can stop function immediately.

21

LCD
All indicators on the LCD Panel shown below: Frame appears around selected mode Press any button when the power is on, selected function will be displayed. Meanwhile, the LCD backlight lights up, and the backlight will automatically go off after 10 seconds.

Key Lock

ION

Airflow

Hi

indicators Lo

Humidity indicator (Current)- indicates the current humidity (Selection)- indicates set humidity level The humidity setting range from 40% ~ 70%

Swing Monitor

Mode indicators Indicates the dehumidify mode
Drying clothes indicators

Timer display
Display the time set for auto shutdown

Quiet Normal Speed

Louver Indicator This indicates the range of louver swing

LCD Backlight indicator different ambient humidity and unit condition: 1. Deep Blue: Ambient humidity is greater than RH75% 2. Light blue: Ambient humidity is greater than or equal to RH65% 3. Brightening: Ambient humidity is less than RH65% 4. Deep blue backlight keep flashing: When the unit is tipped over, water tank is full or not place in the right position. 5. High ambient humidity indicator: During standby, when unit detects ambient humidity more than 75%, deep blue backlight will light up. Press “Humidity button” can turn off the indicator light.

22

Be sure of correct voltage is used and plug is well plugged in socket. The unit automatically detects ambient humidity, when room humidity more than RH75% and LCD backlight will light up.(Deep Blue)

Press “/(ON/OFF)” button to start the unit and the Power and Humidity indicator light turn on. Unit operates at “ECO(ECO)” mode automatically set as below situation:

3

Unit operates at “ECO(ECO)” , according to room humidity. When room humidity is over RH50%, compressor will turn on in 3 minutes after the”/(ON/OFF)” button is pressed .
(When the plug is connected to power more than three minutes, the compressor will start immediately)

You can adjust the dehumidification mode according to the actual situation, press “(Mode)” button to switch to other function:
ECO(ECO) (Dry) (Comfort) (Continue)

3

ECO(ECO) : Select “ECO”(ECO) mode, unit operates automatically with low energy consumption and keep humidity level between 50% ~ 60% ; or operates at low speed(compressor is off) when humidity is less then 45%.
(Dry):Unit operates continually to maintain ambient humidity level under 50%. (Comfort):Unit operates continuously to keep ambient humidity at a suitable level for human body.
(Continue):Unit operates continuously dehumidification regardless of the ambient humidity level until water tank full or Power button is pressed.

You can adjust the “(Dry clothes)”mode by press”(Dry clothes)”button to switch to other function: (Standard) (Quiet) (Speed)

3

The unit turn on/off the fan and compressor automatically according to the ambient humidity and temperature.
(Standard):Select”(Standard)” mode, unit operates at middle speed fan to dry clothes in enegry saving. (Quiet):Select”(Quiet)” mode, unit operates at low speed fan and suitable for night time or sleeping. (Speed):Select”(Speed)” mode, unit operates at high speed fan to dry clothes quickly.
The unit operates for 8 hours and automatically switches off. Restart the unit if it turns off before the laundry dries.

23

Humidity Selection

Pressing the button once displays the set humidity level with the

(Selection)indicator. After 4 seconds,

the display returns to the current humidity display and shows the word (Current)

60% 65% 70% 40% 45% 55%

3

Humidity sensor detects the ambient level and keeps indoor humidity at the set humidity.

Select “(Air Clean)” mode, press to select low or high air volume, and compressor

is off.

(Low speed)

(High speed)

3

Louver Setting

When power is on, the direction of the louver is inclined at 45 degree. Press “(Louver )”button to select

the louver swing range.

Down

Up

Wide

Swinging stops

(Degree 0~45 °) (Degree 45 °~90 °) (Degree 0~90 °)
Note:Do not move the louver while swinging operation is in progress.
Press “(Timer)” button to select the shutdown timer.
OFF 1 hr 2 hrs 3hrs 4 hrs 5hrs….10hrs 11hrs 12hrs
After timer is set, unit will display time remaining.

When unit is tipped over, operation will stop automatically, Humidity Indicator is flashing and alarm.
1. Disconnect the power cord 2. Place the unit in an upright position on a stable, flat surface 3. Insert the power cord again and restart the unit
(Compressor starts once the plug plugged in the socket after 10 minutes)

24

Key Lock setting
During standby or operation, please press “(Key Lock)” button for 3 seconds to active the Key Lock. When the LCD Lock lights up, the unit can’t be switched off or on and all functions are not available until the key lock has been released.
Key Lock off To release the key lock by pressing “(Key Lock)” button again for 3 seconds. The key lock lamp goes out.

3

Air purifying function
During operation, press “(ION)” button to turn on and off the negative ion. When LED is on, the unit releases negative ions to purify the air.

3

The unit will be operated in the range 5~35

25

C

3

3 louver angle for selection.

ECO mode Auto humidity setting to keep humity level between 50~60%.

26

When water tank is full(5L), the water tank full indicator will light up and flash, the unit will stop operation. Please empty water tank for operation resume.
Don’t immediately remove water tank when full water LED light up, until few minutes later and no water attached on the cooling system. Press power off and empty water before moving the unit to avoid water spillage on floor or penetrate to inner part. The dehumidified water on the evaporator is likely to frost at low temperature, which may cause the dehumidification water to not drip inside the water tank, it is not a malfunction. Water drain hole at middle plate must be cleaned to avoid water blockage. Please do not take out or throw away the polyfoam floater in this water tank, otherwise it will cause auto-stop function failure.
27

Continuous Drainage: Caution: Do not drain water continuously if there is a possibility unattended for long periods.
28

Dust or dirt clogged filter will result in reduced dehumidification efficiency and may cause failure. Clean once every 2 weeks.
(Dry the filter before reinstall)
29

Main unit Using a soft cloth moistened with warm water (below 40 degree) or mild detergent to wipe the unit. Clean with neutral detergent and wipe with a wet cloth.
. Cover with plastic bag and place the unit under a area not shone by sun and good ventilation.
30

Remove air inlet cover
31

RPD-YS27GU

Rated Voltage/Frequency Rated Capacity(L/Day)

220-240V~ 50Hz
14.9L (26.7 RH60%) 27L (30 RH80%)

Rated Power Rated current

265W 1.25A

Refrigerant & Amount Tank Capacity

R134a,350g 6L (5L Shut off)

Net Weight

15.8 kg

Dimension(mm)

600H x 370W x 263D(mm )

3.An electronic copy of the user manual can be emailed to the customer if necessary,please call Shun Hing Electric Works and Engineering Co.,Ltd:28612767
32

Trouble shooting and Emergercy Handling
Before requesting for repairs, check the following points.
6
If any abnormalities, please turn off the unit and disconnect the power cord If the above solution can not fix the problem, please contact Shun Hing Electric Service Centre Limited for check and repair.
33

211

(852) 2406 5666

(852) 2408 0316

/ (852) 2406 5666

www.shesc.com

11th Floor, Shun Hing Centre, 2 Shing Yiu Street, Kwai Chung, New Territories, Hong Kong

Tel : (852) 2406 5666

Fax : (852) 2408 0316

Consumables/Accessories Sales Hotline : (852) 2406 5666

Website : www.shesc.com

21

(852) 2406 5439

(852) 2408 1389

193~1995I

(853) 2836 2928

(853) 2833 6405

: www.shesc.com

1 st Floor, Shun Hing Centre, 2 Shing Yiu Street, Kwai Chung, New Territories, Hong Kong

(852) 2406 5439

(852) 2408 1389

Avenida de Venceslau de Morais, No. 193~199, 5 andar – I, Edf. Industrial Nam Leng, Macau

(853) 2836 2928

(853) 2833 6405

www.shesc.com

RPD/YS/2210

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Rasonic User Manuals

Related Manuals