WXsmart T0055749401 Safety Booklet Instruction Manual
- June 13, 2024
- WXsmart
Table of Contents
- WXsmart T0055749401 Safety Booklet
- Product Information
- Product Usage Instructions
- Wiring Connection
- Safety information
- Specified Conditions Of Use
- WXS Remote Control
- User groups
- Care and maintenance
- Warranty
- Symbols
- Technical Data
- EC declaration of conformity
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
WXsmart T0055749401 Safety Booklet
Product Information
- Product Name: WXsmart
- Manufacturer: Weller Tools
- Website: https://www.weller-tools.com/wxsmart
- Power Supply: 110 V – 120 V (for LAN), 230 V (for RS232)
- User Manual Languages: DE, EN, IT, PT, NL, SV, DK, FI, GR, PL, HU, SK, SL, EE, LV, LT, BG, HR, RU, CN, KO, JP
Product Usage Instructions
Safety Information
- Keep other people away from your workspace.
- WARNING: Risk of electric shock.
- WARNING: Risk of burns
- WARNING: Risk of fire.
User Group
- Electrical professionals for replacing electrical parts and specifying maintenance intervals.
- Safety professionals for operating and changing filters.
- Laypersons for operating and changing filters and replacing electrical parts under supervision.
- Technical apprentices under the guidance of a trained professional.
Care and Maintenance
- Only use original WELLER spare parts. – Follow the specified maintenance intervals.
Warranty
- Refer to the warranty terms provided by the manufacturer.
Symbols
- Caution! – Warning! Risk of burns!
- Read the operating instructions!
- Grounding symbol.
- Fuse symbol.
- Safety transformer symbol.
Technical Data
- Dimensions (L x W x H): 173 mm x 153 mm x 142 mm / 6.81 inch x 6.02 inch x 5.59 inch
- Weight: 4.5 kg
- Voltage: 100 V AC / 50/60 Hz (for LAN), 120 V AC / 60 Hz (for LAN), 230 V AC / 50/60 Hz (for RS232)
- Power: 300W
- Protection class: 100 V / T6.3A (for LAN), 120 V / T5A (for LAN), 230 V / T3.15A (for RS232)
Safety Guidelines
- Read the instructions and safety guidelines carefully before using the device.
- Children and youths under the age of 16 and those unfamiliar with the operating instructions should not use the device.
- Children should be supervised to prevent them from playing with the tool. Please note that this is a text extract from the user manual. For complete and detailed instructions, refer to the user manual provided with the product.
https://www.weller-tools.com/wxsmart
Wiring Connection
Read these instructions and the safety guidelines carefully before starting up
the unit and starting work.
Failure to observe the safety regulations results in a risk to life and limb.
Keep these instructions in a place that is accessible to all users. Please
adhere to the operating instructions of the connected devices.
Safety information
For safety reasons, children and youths under the age of 16, as well as per-
sons who are not familiar with these operating instructions, may not use the
device. Children should be supervised in order to ensure that they do not play
with the tool.
This appliance can be used by children aged from 8 years and above and persons
with reduced physical, sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or instruction concerning
use of the appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without super-
vision.
Keep other persons well away from your workplace. Children and other
unauthorized persons must stay clear of the work area. Never allow other
persons to touch the soldering tool or cable.
WARNING Electrical shock
Connecting the control unit incorrectly poses a risk of injury due to electric
shock and can damage the device.
- Carefully read the attached safety information, the safety information accompanying these operating instructions as well as the operating instructions for your control unit before putting the control unit into operation and observe the safety precautions specified therein.
- Only connect WELLER tools.
If the device is faulty, active electrical conductors may be bare or the PE conductor may not be functional.
- Repairs must always be referred to a Weller-trained specialist.
- If the electrical tool‘s power supply cord is damaged, it must be replaced with a specially prefabricated power supply cord available through the customer service organization.
- Protect yourself against electric shocks. The handles on soldering tools with an antistatic design are conductive.
- Avoid touching earthed objects such as pipes, heaters, cookers and refrigerators.
- Do not use the soldering tool in a damp or wet environment.
- Never work on voltage-carrying parts.
WARNING Risk of burns
Risk of burns from the soldering tool while the control unit is operating.
Tools may still be hot long after they have been switched off.
-
Always place the soldering tool in the safety rest while not in use. Make sure the safety holder is stable.
-
Only connect the vacuum and hot air at the designated points.
-
Do not direct hot air soldering tools at people or inflammable objects.
-
Only replace solder tips when cold
Risk of burning through liquid solder. Protect yourself against solder splashes. -
Wear appropriate protective clothing to protect yourself against burns. Protect your eyes by wearing eye protection.
-
When working with adhesives, special attention must be paid to the warning information provided by the adhesive manufacturer.
Store your soldering tool in a safe place. When not in use, units and tools should be stored in a dry, high or locked area out of the reach of children. Make sure that unused soldering tools are free of voltage and depressurized.
WARNING Fire hazard
Covering the soldering iron or the safety holder poses a fire hazard.
- Always keep objects well away from the soldering iron and safety holder.
- Keep all combustible objects, liquids or gases well away from the hot soldering tool.
The power cable must only be plugged into the power socket or adapter approved
for this purpose. Check to see if the mains voltage matches the ratings on the
nameplate. Make sure the machine is switched off before plugging in.
Do not use the cable for purposes other than those for which it is intended.
Never carry the unit by the cable. Do not use the cable to pull the plug out
of the socket. Protect the cable against heat, oil and sharp edges.
Be alert. Pay attention to what you are doing. Be smart when using the unit.
Do not use the soldering tool if you are having difficulty concentrating.
Avoid abnormal posture. Arrange your work station in an ergonomically correct
way. Avoid bad posture when using the unit, as this can lead to postural
problems.
The soldering tool must be operated only in perfect technical working order.
Safety devices must not be deactivated.
Faults and defects must be repaired immediately. Before using the unit / tool,
safety devices must be carefully checked to make sure that they are
functioning properly and in the manner intended. Check that moving parts are
functioning properly and are not sticking, and whether parts are damaged. All
parts must be correctly fitted and must satisfy all the requirements necessary
to guarantee trouble free operation of the unit.
Use the correct tool. Use only accessories or auxiliary de-vices which are
included in the list of accessories or approved for use by the manufacturer.
Use WELLER accessories or auxiliary devices on original WELLER equipment only.
The use of other tools and other accessories can cause injury.
Secure the tool. Use clamping fixtures to hold the workpiece.
Use a solder fume extraction unit. If appliances for connecting solder fume
extraction units are available, ensure that they are connected and used
properly.
Specified Conditions Of Use
Supply unit for WELLER WX soldering tools. Use the soldering station / desoldering station / hot air station exclusively for the purpose indicated in the operating instructions of soldering and desoldering under the conditions specified herein.
WARNING
Flammable gases and liquids may not be extracted.
The device may only be used with correctly fitted and suitable filter
cartridges.
Replace filter cartridges when full.
This device may only be used at room temperature and indoors. Protect against
moisture and direct sunlight.
WXS Remote Control
As soon as you have installed the Weller WXS app on your mobile device and
have connected to the Weller WXS station, the remote control is activated via
an app.
You can now perform the described device functions with your mobile device by
using the app.
Note: Direct operation at the WXS station by a user does not have priority
over access via the app.
Both options for operation have equal priority. Therefore, it must be ensured
that any unintentional remote access via the app does not endanger the user or
damage furnishings.
Weller therefore recommends switching off the station via the ON/OFF switch
before changing tools or tips, etc.
In general, the soldering tools must be placed in the associated safety holder
when not in use. This will ensure that the tool does not pose a hazard.
User groups
Due to differing degrees of risk and potential hazards, sever-al work steps may only be performed by trained experts.
Work step: User groups
-
Default soldering parameters
Specialist personnel with technical training -
Replacing electrical replacement parts
Electricians -
Default maintenance intervals
Safety expert -
Operation Filter change
Non-specialists -
Operation Filter change
Replacing electrical replacement parts
Technical trainees under the guidance and supervision of a trained expert
Care and maintenance
WARNING
Before doing any work on the machine, pull the plug out of the socket.
Clean the operator panel, if dirty, using a suitable cleaning cloth.
Seal ports which are not in use with covering caps. Check all connected cables
and hoses on a regular basis. If power tools are damaged, they must be
immediately removed from use.
WARNING Risk of burns
- Only replace solder tips when cold
- Replace and clean suction nozzles only when hot and using the suitable tool
- Only replace hot air nozzles using the suitable tool
- Only clean or replace solder collection tubes when cold
Filter change
Regularly check the main filter for vacuum, and replace it if necessary.
Contaminated filters must be treated as special waste. Dispose of replaced
equipment parts, filters or old devices in accordance with the rules and
regulations applicable in your country. Wear suitable protective gear.
Warning!
Working without a filter can result in irreparable damage to the vacuum unit.
Check before starting soldering whether a main filter is inserted.
Repairs must always be referred to a Weller-trained specialist.
Use original replacement parts only.
Warranty
Claims by the buyer for physical defects are time-barred after a period of one
year from delivery to the buyer. This does not apply to claims by the buyer
for indemnification in accordance with §§ 478, 479 BGB (German Federal Law
Gazette).
We shall only be liable for claims arising from a warranty furnished by us if
the quality or durability warranty has been furnished by use in writing and
using the term „Warranty“. The warranty shall be void if damage is due to
improper use and if the device has been tampered with by unauthorized persons.
For more information please visit www.weller-tools.com.
Symbols
- Caution!
- Warning! Risk of burns!
- Read the operating instructions!
- Before performing work of any kind on the unit, always disconnect the power plug from the socket.
- ESD-compatible design and ESD-compatible workstation
- Equipotential bonding
- Soldering
- Desoldering
- Hot air
- CE mark of conformity
- British Conformity Mark
- Fuse
- Safety transformer
- Disposal
Waste light sources have to be removed from equipment. Check with your local authority or retailer for recycling advice and collection point. According to local regulations retailers may have an obligation to take back waste electrical and electronic equipment free of charge. Your contribution to re- use and recycling of waste electrical and electronic equipment helps to reduce the demand of raw materials. Waste electrical and electronic equipment contain valuable, recyclable materials, which can adversely impact the environment and the human health, if not disposed of in an environmentally compatible manner. Delete personal data from waste equipment, if any.
Technical Data
| Soldering station
WXsmart
---|---
Dimensions L x W x H| 173 mm x 153 mm x 142 mm
6,81 inch x 6,02 inch x 5,59 inch
Weight| 4,5 kg
Mains supply voltage| 100 V AC / 50/60 Hz| 120 V AC / 60 Hz| 230 V AC / 50/60
Hz
Power consumption| 300W
Safety class| I, Supply unit
III, Soldering tool
Fuse| 100 V / T6,3A| 120 V / T5A| 230 V / T3,15A
Temperature range Tool dependent| 100 – 450°C (550°C)
200 – 850°F (950°F)
Temperature accuracy| ± 9 °C / ± 17 °F
Temperature stability| ± 2 °C / ± 4 °F
Subject to technical alterations and amendments.
EC declaration of conformity
We hereby declare that the products described herein comply with the following
guidelines:
Authorised to compile technical documentation.
Authorised to compile technical documentation
Product Registration www.weller-tools.com/registration
GERMANY
Weller Tools GmbH
Carl-Benz-Straße 2
74354 Besigheim
Tel: +49 (0)7143 580-0
CHINA
Apex Tool Group
Room 302A,
NO 177 Bibo Road
Shanghai, 201202
Tel: +86 (21) 60880288
THE NETHERLANDS
Apex Tool Group B. V.
Phileas Foggstraat 16
7821 AK Emmen
Tel: +31 (0) 591 66 75 00
GREAT BRITAIN
Apex Tool Group UK Ltd
Registered in England,
Company Number 14127816
Registered Office:
C/O TMF Group 13th Floor,
One Angel Court, London,
EC2R 7HJ, United Kingdom
USA
Apex Tool Group, LLC.
Weller Professional Tools Division
1000 Lufkin Road
Apex, NC 27539
+866-498-0484
MÉXICO
Apex Tool Group Manufacturing
México S. De R.L. de C.V.
Vialidadd el Pueblito 103
Parque Industrial Querétaro
Querétaro, México 76220
Tel: +1 (442) 2111 3800
info@weller-tools.com
www.weller-tools.com
© 2023, Apex Tool Group, LLC.
Weller is a registered Trademark and registered Design of Apex Tool Group,
LLC.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>