Product Information

The ArcticVent-HT is an advanced product designed for heat tube vent freeze protection. It is available in two lengths: 24 inches (ATV-30-24-01) and 42 inches (ATV-30-42-01). The vent pipe size is 3 inches and it is compatible with ABS and PVC pipes. The product is designed to interface directly with a 3 ABS and PVC vent. The ArcticVent-HT is made of a durable outer heat tube casing and includes a plumbing adapter. It is designed to withstand working ambient temperatures ranging from -58F (-50C) to 194F (90C). The product should not be exposed to temperatures above 194F (90C) to prevent damage. The kit includes the Arctic-Vent-HT, the heated plumbing vent, along optional accessories such as the INSUL-3.00 closed cell polyethylene insulation sleeve for 3 pipes (6 inches wide, 10 feet long).

Product Usage Instructions

  1. Before installing the ArcticVent-HT, read the Safety Instructions and Installation Instructions provided in the user manual completely. Check your local building and plumbing codes to ensure compliance with their rules and regulations. Handle the ArcticVent-HT with care to avoid damaging the outer surface of the heat tube.
  2. Ensure that you have the necessary expertise or consult a qualified plumbing, mechanical, or building trade professional for proper installation.
  3. Regularly check unoccupied residences to ensure that all systems, including the ArcticVent-HT, are operating properly.
  4. Do not tamper with or alter the outer heat tube casing and plumbing adapter associated with the ArcticVent-HT system.
  5. Use only Heat-Line specified parts and avoid using substitute parts, adhesives, or solvents.
  6. Install the ArcticVent-HT in a manner that allows for easy servicing and maintenance.
  7. Ensure that the existing plumbing vent layout can accommodate the length of the ArcticVent-HT.
  8. For technical support, contact Heat-Line Freeze ProtectionSystems at 1-800-584-4944.

Note: Adapters may be available for other pipe types and sizes, but it is recommended to default to the ATV-30-42-01 model of the ArcticVent-HT as long as your existing plumbing vent layout can accommodate the length.

Installation Instructions

Description

  • ArcticVent-HT is a non-electric, non-hydronic plumbing vent freeze protection system that employs a proprietary heat tube technology that transfers warm energy from the inside lower vent pipe to the upper vent rim using special refrigerants and capillary processes.
  • The ArcticVent-HT heat tube simply slides into existing 3-inch plumbing ABS and PVC vent stacks without their removal.
  • No adhesives or solvents are required.
  • The connection is intentionally designed to be detachable, allowing the ArcticVent-HT to remain serviceable.
  • Prolonged cold temperatures cause plumbing vent stacks to ice up and form a blockage as warm moist air rises, condenses, and freezes. ArcticVent-HT eliminates this ice blockage where it exits the roof of a building promoting healthier living conditions.
    • Never cut, drill or alter this product in any manner.
    • Designed for working ambient temperatures ranging from -58F (-50C) to 194F (90C).
  • The ArcticVent-HT is a technically advanced product. Handle it with proper care and be sure not to damage the outer surface of the heat tube.
  • Read the Safety Instructions and Installation Instructions completely before installing this product.
  • For technical support call Heat-Line Freeze Protection Systems at 1-800-584-4944.
  • This product must be installed in accordance with governing plumbing and building authorities.

WARNING

Important Safety Instructions and Rules for Safe Installation and Operation

  • A. Read these rules and instructions carefully. Failure to follow them could result in serious bodily injury and/ or property damage.
  • B. Check your local building and plumbing codes before installing. You must comply with their rules.
  • C. Never tamper with or alter the outer heat tube casing and plumbing adapter associated with your ArcticVent-HT system.
  • D. Component approvals and performance are based on the use of Heat-Line specified parts only. Do not use substitute parts, adhesives or solvents.
  • E. Proper completion of this installation may require the expertise of a qualified plumbing, mechanical, and or building trade.
  • F. Check unoccupied residences regularly to ensure that all systems are operating properly.
  • G. Do not install the ArcticVent-HT in a manner that could render the system non-serviceable.
  • H. Designed for working ambient temperatures ranging from -58F (-50C) to 194F (90C).
  • I. Do not expose to temperatures above 194F (90C).

ArcticVent-HT Installation

Product Codeheat-line-ArcticVent-HT-Advanced-Heat-Tube-Vent-Freeze-
Protection-FIG-1 \(12\)

Specifications

heat-line-ArcticVent-HT-Advanced-Heat-Tube-Vent-Freeze-
Protection-FIG-1 \(1\)

Note: ArcticVent-HT is designed to interface directly with a 3″ ABS and PVC vent only. Adapters may be available for other pipe types and sizes. Always default to the ATV-30-42-01 model of the ArcticVent-HT as long as your existing plumbing vent layout can accommodate the length.

Kit Contents

heat-line-ArcticVent-HT-Advanced-Heat-Tube-Vent-Freeze-
Protection-FIG-1 \(13\)

Package Weight and Dimensions

ATV-30-24-01

  • Package Length 31″ (787 mm)
  • Package Width 7″ (178 mm)
  • Package Height 7″ (178 mm)
  • Package Weight 4 lbs (1.81 kg)

ATV-30-42-01

  • Package Length 48″ (1219 mm)
  • Package Width 7″ (178 mm)
  • Package Height 7″ (178 mm)
  • Package Weight 6 lbs (2.72 kg)

ArcticVent-HT 24″ Installation

  • For the ArcticVent-HT to fit securely onto the existing vent pipe, it is crucial that the vent pipe extends at least 3 inches above the flashing.

  • To ensure optimal performance, the height of the existing vent pipe cannot exceed 10 inches. Adhere to all local building and plumbing codes, you must comply with their specific requirements.

    • Note: The greater the length of the ArcticVent-HT inserted below the roof line, the greater performance.heat-line-ArcticVent-HT-Advanced-Heat-Tube-Vent-Freeze-Protection-FIG-1 \(2\)
  • To properly install the ArcticVent-HT, it is critical to ensure that the entire length of the ArcticVent-HT heat tube can be inserted into the existing vent pipe without any obstructions.

  • Verify that there are no fittings or blockages within the vent pipe for the first 26 inches that could impede the passage of the ArcticVent-HT.

  • In a controlled manner guide the ArcticVent-HT downwards into the vent pipe.

  • Ensure alignment of the ArcticVent-HT adapter and vent pipe, and then with consistent and controlled force push the adapter down over the vent to obtain a snug and firm connection.

    • Note: Do not to use solvents or adhesives for the purpose of attaching the adapter and vent pipe. The connection is intentionally designed to be detachable, allowing the ArcticVent-HT to remain serviceable.
  • Apply insulation to fully cover the entire exposed length of both the vent pipe and ArcticVent-HT (optional, but highly recommended). It may be necessary to trim the insulation sleeve to the appropriate length, as each exposed section of the vent pipe can vary in height.

  • If accessible, it is recommended to apply insulation to the exposed section of the vent pipe within the unheated attic space.

    • Note: Insulation will enhance performance in extreme cold and wind chill. It is highly recommended.
  • For the ArcticVent-HT to fit securely onto the existing vent pipe, it is crucial that the vent pipe extends at least 3 inches above the flashing.

  • To ensure optimal performance, the height of the existing vent pipe cannot exceed 16 inches. Adhere to all local building and plumbing codes, you must comply with their specific requirements.

    • Note: The greater the length of the ArcticVent-HT inserted below the roof line, the greater performance.heat-line-ArcticVent-HT-Advanced-Heat-Tube-Vent-Freeze-Protection-FIG-1 \(7\)
  • To properly install the ArcticVent-HT, it is critical to ensure that the entire length of the Arctic Vent-HT heat tube can be inserted into the existing vent pipe without any obstructions.

  • Verify that there are no fittings or blockages within the vent pipe for the first 44 inches that could impede the passage of the ArcticVent-HT.

  • In a controlled manner guide the ArcticVent-HT downwards into the vent pipe.

  • Ensure alignment of the ArcticVent-HT adapter and vent pipe, and then with consistent and controlled force push the adapter down over the vent to obtain a snug and firm connection.

    • Note: Do not to use solvents or adhesives for the purpose of attaching the adapter and vent pipe. The connection is intentionally designed to be detachable, allowing the Arctic Vent-HT to remain serviceable.
  • Apply insulation to fully cover the entire exposed length of both the vent pipe and ArcticVent-HT (optional, but highly recommended). It may be necessary to trim the insulation sleeve to the appropriate length, as each exposed section of the vent pipe can vary in height.

    • Note: Insulation will enhance performance in extreme cold and wind chill. It is highly recommended.

Limited Warranty

  • During the time periods and subject to the conditions hereinafter set forth. Heat-Line will repair or replace to the original user any portion of your Arcticent-HT product that proves defective in materials or workmanship of Heat-Line.
  • Contact Heat-Line or your installer for warranty service.
  • At all times Heat-Line shall have and possess the sole right and option to determine whether to repair or replace defective equipment, parts, or components.
  • Damage due to natural events or conditions beyond the control of Heat-Line is NOT COVERED BY THIS WARRANTY.
  • STANDARD WARRANTY PERIOD: 60 months from the date of purchase or 63 months from the date of manufacture, whichever occurs first.
  • EXTENDED WARRANTY PERIOD: 120 months from the date of purchase or 123 months from the date of manufacture, whichever occurs first.
  • ACCESSORIES, COMPONENTS, ELECTRONICS: Not manufactured by
  • Heat-Line, are warranted only to the extent of the original manufacturer’s warranty.
  • LABOUR, COSTS, ETC.: Heat-Line shall in NO EVENT be responsible or liable for the cost of field labor or other charges incurred by any customer in removing and/or reaffixing any Heat-Line product, part, or component thereof.

Important: All information, including illustrations, is believed to be reliable. Users, however, should independently evaluate the suitability of each product for their particular application. Heat-Line a Division of Christopher MacLean Ltd. makes no warranties as to the accuracy or completeness of the information, and disclaims any liability regarding its use. Heat-Line’s only obligations are those in the Heat-Line Standard Terms and Conditions of Sale for this product, and in no case will Heat-Line be liable for any incidental, indirect, or consequential damages arising from the sale, resale, use, or misuse of the product. Specifications are subject to change without notice. In addition, Heat-Line reserves the right to make changes- without notification to Buyer- to processing or materials that do not affect compliance with any applicable specification.

CONTACT

CONGRATULATIONS!
You have just purchased the most advanced internal freeze-protection system available on the market, backed by the finest warranty offered in the industry. Your ArcticVent-HT system comes with a standard 5-year limited warranty with an optional 10 year limited warranty available.~ The warranty applies only to the original purchaser of the product and is not transferable at any time for any reason. The warranty form must be filled out and returned to Heat-Line within 6 months of invoice date or unit manufactured date plus 9 months to be eligible for the 10 year extended warranty. ~

LIMITED WARRANTY

  • During the time periods and subject to the conditions hereinafter set forth. Heat-Line will repair or replace to the original user any portion of your Arcticent-HT product that proves defective in materials or workmanship of Heat-Line. Contact Heat-Line or your installer for warranty service.
  • At all times Heat-Line shall have and possess the sole right and option to determine whether to repair or replace defective equipment, parts or components. Damage due to natural events or conditions beyond the control of Heat-Line are NOT COVERED BY THIS WARRANTY.
  • STANDARD WARRANTY PERIOD: 60 months from the date of purchase or 63 months from the date of manufacture, whichever occurs first.
  • EXTENDED WARRANTY PERIOD: 120 months from the date of purchase or 123 months from the date of manufacture, whichever occurs first.
  • ACCESSORIES, COMPONENTS, ELECTRONICS: Not manufactured by Heat-Line, are warranted only to the extent of the original manufacturer’s warranty.
  • LABOUR, COSTS, ETC.: Heat-Line shall in NO EVENT be responsible or liable for the cost of field labor or other charges incurred by any customer in removing and/or reaffixing any Heat-Line product, part or component thereof.
  • THIS WARRANTY WILL NOT APPLY (a) to defects or malfunctions resulting from failure to properly install, operate, or maintain the unit in accordance with printed instructions provided,
    • (b) to failures resulting from abuse, accident, or negligence;
    • (c) to normal maintenance services and
    • (d) to parts not used in accordance with applicable local codes, ordinances, and good trade practices;
    • (e) if the unit is moved from its original installation location or
    • (f) if the unit is used for purposes other than for what it was designed and manufactured,
    • (g) to the integral ground fault device and related electronics. PRODUCT IMPROVEMENTS: Heat-Line reserves the right to change or improve its products or any component thereof without being obligated to provide such a change or improvement for units sold and/or shipped prior to such change or improvement.
  • WARRANTY EXCLUSIONS: As to any Heat-Line product after the expiration of the time period of the warranty applicable thereto as set forth above. There will be no warranties including any implied warranties of merchantability or fitness for any particular purpose. No warranties or representations at any time made by any representative of Heat-Line shall vary or expand the provisions hereof.
  • LIABILITY LIMITATION: In no event shall Heat-Line be liable or responsible for consequential, incidental, or special damages resulting from or related in any manner to any Heat-Line product or parts thereof. In the absence of suitable proof of the purchase date, the effective date of this warranty will be based upon the date of manufacture plus 90 days.

PROOF OF PURCHASE

  • If a proof of purchase copy is submitted with this warranty application form, the warranty period will be effective as of the invoice date. In the absence of suitable proof of purchase, the effective date of this warranty will be based upon the date of unit manufacture plus 3 months.
  • Proof of purchase (invoice) attached: Yes No
  • By signing below you acknowledge you have read and understand the full limited warranty document.

The warranty form must be filled out and returned to Heat-Line within 6 months of the invoice date or unit manufactured date plus 9 months to be eligible for 10 10-year extended warranty.
© 2023 Heat-Line a division of Christopher MacLean Ltd. 07/23-5