VEVOR SCA-90BW Electric Sauna Heater User Manual

June 13, 2024
VEVOR

VEVOR-LOGO

VEVOR SCA-90BW Electric Sauna Heater

VEVOR-SCA-90BW-Electric-Sauna-Heater-PRODUCT

Product Information

Model SCA-90BW
Power Supply (V/Hz) 220/6
Power (Kw) 9
Sauna Room Min: 9, Max: 13
Suggestion Heating Time 30-50 minutes

Product Usage Instructions

Check that the following parts are included in the packaging:

  1. Sauna heater
  2. Sauna control panel
  3. Temperature sensor unit
  4. Bracket screws x 7 (412mm 3pcs for sauna control panel; 640mm 2pcs, 6*16mm 2pcs for sauna heater)
  5. Fork terminal x 9 (6pcs for control panel, 3pcs for sauna heater)

WARNING:

  1. Electrical shock hazard: To avoid electrical shock hazards, all installations and relevant services shall be performed by qualified personnel.
  2. Sauna bath time should be less than half an hour: Bathing too long may cause the heart to beat too fast, heartache, and feeling weak or dizzy. Users should stop sauna baths immediately as soon as the above symptoms occur.
  3. A sauna bath may cause tension in bathers: Thus, those who have one of the symptoms below should take a sauna bath under the direction of a physician:
    • A. Being pregnant
    • B. Having heart disease
    • C. Having high blood pressure
    • D. Having circulation system disease
    • E. After drinking
    • F. After taking medicine
    • G. Diabetes
    • H. Not feeling well

BEFORE INSTALLATION

Parts
Check that the following parts are included in the packaging:VEVOR-SCA-90BW-
Electric-Sauna-Heater-FIG-1 \(1\)

  1. Sauna heater
  2. Sauna control panel
  3. Temperature sensor unit
  4. Bracket screws x 7 (412mm 3pcs for sauna control panel ; 640mm 2pcs, 6*16mm 2pcs for sauna heater)
  5. Fork terminal x 9 (6pcs for control panel, 3pcs for sauna heater)

WARNING

  1. Electrical shock hazard——To avoid electrical shock hazards, all installations and relevant services shall be performed by qualified personnel.
  2. Sauna bath time should be less than half an hour. Bathing too long may cause the heart to beat too fast, heartache, and feeling weak or dizzy. Users should stop sauna baths immediately as soon as the above symptoms occur.
  3. A sauna bath may cause tension in bathers. Thus, those who have one of the symptoms as below should take a sauna bath under the direction of physician:
    • A. Being pregnant
    • B. Having heart disease
    • C. Having high blood pressure
    • D. Having circulation system disease
    • E. After drinking
    • F. After taking medicine
    • G. Diabetes
    • H. Not feeling well
  4. Children must be in the company of adults during sauna baths.
  5. Risk of scald: Must not touch or move the sauna heater during heating. Stay at least 30cm away from the hot heater.
  6. Use ordinary drinking water only. It may damage the heating elements when water with other materials is poured into the stone compartment, which is beyond our guarantee.
  7. Odors may occur during the first sauna bath as the Anti-rust oil for heating elements, which will disappear after the sauna heater powers on when opening the sauna door for about 10-15mins.

INSTALLATION DIAGRAM

INSTALLATION DIAGRAM OF TEMPERATURE SENSOR AND SAUNA HEATER

  • Temperature sensor and sauna heater must be installed strictly according to the following diagrams.(See Fig3 and Fig4)
  • A heat-resistant cable of 3 meters is provided with the control panel, which can be extended to the outside of the sauna room by normal weak current cables.
  • Failure to follow these causes a too high temperature and a fire hazard(Unit: mm).VEVOR-SCA-90BW-Electric-Sauna-Heater-FIG-1 \(2\)
  • Remark: 1. The upper screws must be fastened tight, the minimum distance between the screw head and the wall is 3mm.
  • Remark: 2. The wall behind the heater is not allowed to be covered by materials like asbestos cement, asbestos board, and so on because this sort of covering layer could cause high temperatures and a risk of burn.
  • Remark: 3. Must use qualified materials for the walls and ceiling.

SPECIFICATIONS

Model| Power Supply (V/Hz)
220/6

0

| Power (Kw)| Sauna room Volume(m³)| Suggestion heating time
---|---|---|---|---
Min| Max| (28-70℃)
SCA-90 BW| 9| 9| 13| 30-50min
The above suggested heating time should be achieved, including but not limited to these:
1.  Room thermometer installed opposite to the sauna heater, closing to the ceiling.
2. The sauna room is installed indoors with insulation for diffusion prevention purposes.
3.  Temp knob adjusts to the Max.

INSTALLATION OF TEMPERATURE SENSOR

  1. Carefully unload the low cover at the neck position by the edge of the circuit board with a screwdriver slotted
  2. Fasten the circuit board with a bolt to the wall straight over the sauna heater. Check the diagram for minimum distance(See fig3).
  3. Fix the cover to the temperature sensor.

LIMIT CONTROL

  • Fitted as a safety feature is an overheating controller that prevents the heater, in the eventuality of some fault, like a problem with the thermostat.
  • Should the temperature in the sauna room reach too high, the spare link in the sensor unit automatically cuts off the electricity power.
  • When the temperature is back to normal, the spare link will return to its own position automatically.VEVOR-SCA-90BW-Electric-Sauna-Heater-FIG-1 \(6\)

GUARD RAIL
Please follow the minimum distance requirements in Fig 6 if a guardrail is desired for the heater.VEVOR-SCA-90BW-Electric-Sauna-Heater-FIG-1
\(7\)

OPERATION OF CONTROL PANEL

The control panel is splash-proof and can be installed in a dry place near the sauna room. The temperature sensor unit must be installed on the wall inside the sauna room. Please follow the minimum safety distance of the sauna heater during installation(See fig3),which is included in the installation diagram. Failure to follow these may cause a burn to the wooden wall.

  1. Time table

  2. Temperature table

  3. Prepare to place

  4. Control time

  5. Ozone output (Optional)

  6. Power of room light

  7. Power of heater

  8. Adjust present time:
    Press “H” to adjust the hour until the figure becomes stable, then press “M” to adjust the minutes

  9. Set temperature:
    Press “P” to set the temperature, then press“▲” or “▼” to control the temperature until the figure becomes stable after about 3 seconds(setting range 35-110℃/95-230℉, default temp is 60℃/140℉)

  10. Work mode:

    • Normal working mode
      Press “P” to start the sauna heater directly, its operation time can last 4 hours.

    • Preset working mode

    • A. Auto-start setting (Max 24 hours): Press “Prepare to place” to fix the time, then press “H” and “M” to set the time before “P” to finish.

    • B. Auto-Stop setting (Min 10mins, Max 4 hours): Press “Control time” to adjust the time, then press “H” and “M” to set time, before the table finishing blink.

    • Remark: Steps 1, 3.1 and 3.2.A must be operated during unworking of the sauna heater; Step 2 and 3.2.B must be operated during the working of sauna heater)

SAUNA ROCKS
Load sufficient sauna rocks(10-15kg) into the sauna heater after finishing the installation of sauna heater and controller.
ATTENTION: Sauna rocks must be of best quality because temperature inside sauna heater is extremely high. Rocks of inferior quality cant withstand heat and they maybe easily broken or crumbling because of the huge heat changing, which may damage heating elements. These stones may counteract the heat circulation because they are easily oxidized, then sauna heater maybe damaged while stone is being heated or being poured water to make vapors.

VENTILATION

  • To have a smooth sauna bath, there should be a proper mixing of hot and cold air inside the sauna room. Another reason for ventilation is to draw air around the sauna heater and move the heat to farthest part of sauna room.
  • The inlet vent with a diameter more than 6cm should be installed directly below the sauna heater.(See fig 5)
  • The outlet vent should be installed diagonally opposite to the inlet, its suggested to place under the platform inside the sauna room as far as possible from the inlet vent.
  • The diameter of the outlet vent should be twice as big as the inlet, it may be installed far away the floor and under the bottom of the upper bench.

GUARANTEE

The following situations are not guaranteed:

  1. Installation or dis-assembly of the inside structure by unprofessional personnel;
  2. Supply voltage fluctuation range>±10%;
  3. Unqualified rocks on sauna heater’s operation;
  4. Installation without following the dimension instructions inside the manual.

TROUBLESHOOTING

VEVOR-SCA-90BW-Electric-Sauna-Heater-FIG-1
\(10\)

Attached Diagram

VEVOR-SCA-90BW-Electric-Sauna-Heater-FIG-1
\(9\)

Address: Baoshanqu Shuangchenglu 803long 11hao 1602A-1609shi Shanghai
Imported to USA: VEVOR STORE INC, 9448 RINCHMOND PL #E RANCHO CUCAMONGA, California, 91730 United States of America

Technical Support and E-Warranty Certificate: www.vevor.com/support. We continue to be committed to providing you tools with at competitive prices. “Save Half”, “Half Price” or any other similar expressions used by us only represent an estimate of savings you might benefit from buying certain tools with us compared to the major top brands and do not necessarily mean covering all categories of tools offered by us. You are kindly reminded to verify carefully when you are placing an order with us if you are actually saving half in comparison with the top major brands.
MODEL: SCA-90BW

NEED HELP? CONTACT US!

Have product questions? Need technical support? Please feel free to contact us: at CustomerService@vevor.com. This is the original instruction, please read all manual instructions carefully before operating. VEVOR reserves a clear interpretation of our user manual. The appearance of the product shall be subject to the product you received. Please forgive us that we won’t inform you again if there are any technology or software updates on our product.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals