G DE 94679 Submersible Sewage Pump Instruction Manual

June 13, 2024
G de

GUDE 94679 Submersible Sewage Pump

Product Information

  • Product Name: GS 750.1 INOX
  • Model Number: 94679
  • Technical Specifications:
    • Voltage: 230V
    • IP Rating: X8
    • Flow Rate: 15,000 l/h
    • Maximum Head: 8m

Safety Warnings

  • Danger of electric shock. Do not touch, immerse, lift, or transport the pump while it is electrically connected.
  • The pump must not run without fillings.

Specified Conditions of Use

The pump should not be operated in a dry state.

Emergency Procedure

In case of an emergency, refer to the instructions provided.

Symbols

  • Warning/Attention symbol: Indicates the need to read the operating manual to reduce the risk of injury.
  • Alternating current symbol: Indicates the type of electrical current used.
  • Maximum immersion depth symbol: Indicates the maximum depth the pump can be submerged.

Maintenance

Refer to the cleaning and storage instructions for proper maintenance of the product.

Disposal
Proper disposal methods should be followed according to local regulations.

Guarantee
Information regarding the guarantee is provided in the user manual.

Service
Contact the authorized servize center for any service-related queries or assistance.

Product Usage Instructions

  1. Starting-up the device:

  2. Connect the pump according to the instructions provided.

  3. Ensure that the pump is not in a dry state before starting it.

  4. Cleaning/Storage:
    Follow the instructions provided for cleaning and storing the pump.

  5. Overload Protection:
    Refer to the instructions provided for information on overload protection.

  6. Usage:

  7. To start the pump, press the START button.

  8. The pump will run for 20 seconds.

  9. After 20 seconds, it will automatically stop.

  10. To restart the pump, press the START button again.

  11. The pump can be stopped by pressing the STOP button.
    Note: Please refer to the user manual for detailed instructions and safety precautions.

DELIVERED ITEMS

Connection

GUDE 94679-Submersible-Sewage-Pump-fig-3 GUDE
94679-Submersible-Sewage-Pump-fig-4

Starting-up the device

Engine protection

Cleaning / Storage

Technical Data

  • Art. No 94679
  • Rated voltage 230 V
  • Degree of protection IP X8
  • Max. delivered quantity 15.000 l/h
  • Max. head of delivery Hmax 8 m
  • Max. immersion 7 m
  • Max. suction 35 mm
  • Max. Water temperature 35 °C
  • Service connection 1 1/2“ IG
  • Cable length 10 m
  • Weight 6,5 kg

INTRODUCTION

  • Read and understand the operating instructions before using the appliance. Familiarise with the control elements and how to use the appliance properly. Abide by all the safety measures stated in the service manual. Act responsibly toward third parties.
  • The operator is responsible for accidents or risks to third parties.
  • In case of any doubts about connection and operation refer please to our customer center
  • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Cleaning and user maintenance shall not be made by children without supervision.
  • Children should be supervised in order to ensure that they do not play with the tool. Always keep children and unauthorised persons out of reach of the appliance.

Specified Conditions of Use

  • The pump is solely used for drainage and for pumping into and out of containers in the house, garden, farm and agriculture and only for water. Respecting technical data and safety precautions.
  • Do not use this product in any other way as stated for normal use. Not observing general regulations in force and instructions from this manual does not make the manufacturer liable for damages.
  • Do not use pump at outside temperatures over 40 °C or under 0 °C
    • The pump is not suited for long-run operation (e.g. as a circulation pump in ponds or streams).
    • When used in this manner, its service life is curtailed correspondingly. In these cases, then, use a time switch to secure sufficient idle periods between cycles of operation.
    • Do not leave the pump unattended while in operation in order to prevent subsequent damages caused by eventual malfunctions. Make sure to disconnect the device from the grid if you do not plan on using it.
    • Do not use the pump for drinking water!
    • The pump must not be used to pump waste water.
    • The pump must not be connected to the existing water-supply network as a pressureboosting device.
    • Never use the pump as a pool circulation pump.

Safety Warnings

WARNING! Electric shock! There is a risk of an injury caused by electric shock!

  • Check the cable and/or socket for damages before the appliance putting into operation.

  • Do not grab the feeder cable, plunge the pump, lift or carry it while it is connected to the grid!

  • It is necessary to make sure the connecting socket was not near water and humidity and the plug was protected against humidity.

  • Check the voltage. Technical data given on the type label must correspond with electric network voltage.

  • Only use splash proof extension cables approved for outdoor purposes.

  • Unplug the device prior to submersion, upon termination of operation, in the course of defect removal and prior to performing maintenance procedures.
    WARNING !
    Operation is only allowed with a safety switch against stray current (RCD max. stray current of 30mA).

  • Electric connection to a socket.

  • If the pump is in operation, neither people nor animals can be present or plunged in the pumped liquid (e.g. pools, cellars, etc.).

  • The temperature of the drained liquid must not exceed +35 °C.

  • The pump must not in any case run without fillings.

  • Do not leave the pump unattended while in operation in order to prevent subsequent damages caused by eventual malfunctions. Make sure to disconnect the device from the grid if you do not plan on using it.

  • If the pump is used in ponds, wells, etc. and appropriate pumping stations, standards valid for pumps in the given country must unconditionally be observed.

  • The user is responsible to third parties if pump (dumping stations, etc.) is used.

  • Protect the feeder cable from excessive temperatures, oil and sharp edges.

  • To avoid danger, a damaged mains supply pipe must be replaced by the manufacturer. Do not under any circumstances attempt any repair yourself.

Requirements for operating staff

The operating staff must carefully read the Operating Instructions before using the appliance.

  • Qualification: Apart from the detailed instructions by a professional, no special qualification is necessary for appliance using.
  • Minimum age: Persons over 16 years of age can only work on the appliance. An exception includes youngsters trained in order to reach knowledge under supervision of the trainer during occupational education.
  • Training: Using the appliance only requires corresponding training by a professional or the Operating Instructions. No special training is necessary

Emergency procedure

Conduct a first-aid procedure adequate to the injury and summon qualified medical attendance as quickly as possible. Protect the injured person from further harm and calm them down. If you seek help, state the following pieces of information: 1. Accident site, 2. Accident type, 3. Number of injured persons, 4. Injury type(s)

SYMBOLS

Maintenance

Before any adjustment, cleaning and maintenance work, switch off the device and disconnect it from the power supply.

  • Before using the appliance, perform a visual inspection at all times to make sure the power cord and the plug, in particular, are not damaged on the charger.
  • The appliance must not be used if damaged or safety equipment is defective. Replace any worn-out and damaged parts.
  • If the supply cord of this power tool is damaged, it cannot be replaced, and the power tool shall be scrapped.
  • Repairs and works specified in these Instructions may only be performed by qualified authorised staff.
  • Use only original accessories and original spare parts.
  • Only a regularly maintained and treated appliance can serve as a satisfactory aid. Insufficient maintenance and care can lead to unforeseen accidents and injuries.
  • To ensure long service life of the pump seal we recommend rinsing the pump with clean water in regular intervals.
  • Caution! Depending on the design, water that is left standing for a longer period of time may cause corrosion in the pump housing! (Brown colouration)
  • For winter storage, ensure that there is no water in the device. Otherwise, frost exposure may cause irreparable damage to the device. The pump must be stored in a completely empty and frost-proof state.
  • You can reduce the chance of the mechanical seals sticking by flushing out the pump with suitable oil (e.g. vegetable oil).
  • If necessary, a list of spare parts can be found at www.guede.com.

Guarantee

  • Warranty period of 12 months applies to commercial use and 24 months applies to private use and commences on the day of purchase of the device.

  • The guarantee solely covers inadequacies caused by material defect or manufacturing defect. Original payment voucher with the sales date needs to be submitted for any claim in the guarantee period.

  • The guarantee does not cover any unauthorised use such as appliance overloading, use of violence, damage as a result of any unauthorised interference or caused by foreign items. Failing to follow the operating and assembly instructions and common wear are also not included in the guarantee.

  • GÜDE cannot be held responsible for damages incurred in consequence of unqualified installation or unskilled handling of the pump.

  • The device has to be checked on a regular basis to ensure perfect functioning.

  • Let us refer to the fact we do not assume any responsibility – according to standards in force – for damage eventually caused by our appliances in the belowmentioned cases:

  • Unprofessional repairs executed by unauthorised service centres;

    • Use in conflict with the designed purpose, or failure to observe the use as designed;
    • Pump overload with a continuous run;
    • Damage as a result of icing or any other fault caused by climatic influences;
  • Identical regulations apply for accessory parts.

  • To prevent damage (such as flooded rooms, etc.) as a result of faulty pump operation (failure or fault) the owner (user) is obliged to take reasonable safety measures (alarm assembly, spare pump, etc.).
    Important information for the customer

    • Please note that returns within or outside the warranty period should always be in the original packaging.
    • This measure effectively avoids unnecessary transport damage and any associated disputed ruling.
    • Your equipment is optimally protected only in the original box, and keeping it in that box will ensure smooth processing

Service

Do you have any technical questions? Any claim? Do you need any spare parts or operating instructions? We will quickly help you and without needles bureaucracy at our web pages at www.guede.com in the Servicing part. Please help us be able to help you. In order to identify your device in case of claim we need the serial No., product No. and year of production. All this data can be found on the type label.

Inspection and maintenance plan

GUDE 94679-Submersible-Sewage-Pump-fig-13

Failures – causes – removal

GUDE 94679-Submersible-Sewage-Pump-fig-12

ABOUT COMPANY

  • Güde GmbH & Co. KG
  • Birkichstrasse 6
  • 74549 Wolpertshausen
  • Deutschland
  • www.guede.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>