antaira LMX-1202M-SFP series 12-Port Industrial Managed Ethernet Switch Installation Guide

June 4, 2024
antaira

Antaira Technologies
LMX-1202M-SFP Series
12-Port Industrial Managed Ethernet Switch, w/810/100Tx RJ45,210/100/1000Tx RJ45,
*and 2100/1000 SFP Slots, 12~48VDC
Power Input
Quick Installation Guide
Version 1.1
(November 2019)
antaira LMX 1202M SFP series 12 Port Industrial Managed Ethernet
Switch
**

**** Package Check List

The package contains the following items:

  • 1 – Quick installation guide
  • 1 – LMX-1202M-SFP(-T)
  • 1 – Wall mounting bracket set with screws
  • 1 – DC cable –18 AWG & DC jack 5.5 x 2.1mm
  • 1 – RJ45 to DB9 Serial Console cable
  • 1 – RJ45 dust cover set

Front Panel Layout

antaira LMX 1202M SFP series 12 Port Industrial Managed Ethernet Switch -
Fig

Top Panel View
LMX-1202M-SFP series top panel is equipped with one 6-pin removal terminal block connector for dual DC power inputs (12~48VDC). antaira LMX 1202M SFP
series 12 Port Industrial Managed Ethernet Switch - Top Panel
View

Product Overview

System Interface/Performance

  • All RJ45 ports support the auto MDI function
  • Embedded 810/100Tx RJ45, 210/100/1000Tx RJ45, and 2*100/1000 SFP Slots
  • Store-and-forward switching architecture
  • 8K MAC address table
  • Power line EFT protection: 2,000VDC; Ethernet ESD Protection: 6,000VDC

Power Input & Connection

  • DC 12 to 48V redundant power with a 6-pin removal terminal block
  • It is recommended to use a UL-listed industrial power supply Operating Temperature
  • Standard operating temperature model: -10°C to 70°C
  • Extended operating temperature model: -40°C to 75°C Case/Installation
  • IP30 protection
  • DIN-Rail and wall mount design

LED Indicators

LED Color Description
Power 1 Green On
OR Power input 1 is inactive
Power 2 Green On
OR Power input 2 is inactive
Fault Green/Red Green
Red Preconfigured alarms are detecting a failure
Flashing The switch is in the process of booting
Green On ERPS Owner Mode (Ring Master) is ready
Off ERPS Owner Mode (Ring Master) is not active
Ring Green On
OR Ring Network is not active

LAN Port 1-8
(Upper LED)| | On| Connected to network, 100Mbps
Flashing| Networking is active
OR| Not connected to the network
LAN Port 1-8
(Lamar LED)| | On| Connected to network. 10Mbps
Flashing| Networking is active
OR| Not connected to the network
LAN Port 9-10
(Upper LED)| | On| Connected to network, 1000Mbps
Flashing| Networking is active
OR| Not connected to the network
LAN Port 9-10
(Lower LED)| | On| Connected to network, 10/100Mbps
Flashing| Networking is active
OR| Not connected to the network
SFP Port
11-12
LINK/ACT| Green:1000Mbps
/Amber:100Mbps| On| Connected to network
Flashing| Networking is active
OR| Not connected to the network

Quick Installation

Ethernet Ports
RJ45 Ports (Auto MDI)
All RJ45 ports are auto-sensing for 10Base-T, 100Base-TX, or 1000Base-T device connections. Please follow the wiring pin assignment table below for Ethernet port installation.

RJ45 Ethernet Port Pin Outs

Pins| 7568A Color| 7568B Color| 106ase-T, 100Base-TX 1000| Base-T(X)
Pin 1| white/green stripe| white/orange stripe| Rx+| TPO+
Pin 2| green solid| orange solid| Rx-| TP0-
Pin 3| white/orange stripe| white/green stripe| Tx+| TP1+
Pin 4| blue solid| blue solid| unused| TP2+
Pin 5| white/blue stripe| white/blue stripe| unused| TP2-
Pin 6| orange solid| green solid| Tx-| TP1-
Pin 7| white/brown stripe| white/brown stripe| unused| TP3+
Pin 8| brown solid| brown solid| unused| TP3-

Power Input Wiring
Please follow the steps below to insert the power wire:

  1. Insert the positive and negative wires into the PWR1 (V1+, V1-) and PWR2 (V2+, V2-) contacts on the terminal block connector as shown below in Figure 1.
  2. Tighten the wire-clamp screws to prevent the wires from loosening, as shown below in Figure 2.
    antaira LMX 1202M SFP series 12 Port Industrial Managed Ethernet Switch -
Fig4

Industrial Switch Mounting

DIN-Rail Mounting
The DIN-Rail bracket is pre-installed on the industrial Ethernet switch from the factory. Please refer to Figure 3 for a DIN-Rail bracket installation reference. Follow the steps  below for installing the industrial switch on the DIN-Rail track:

  1. Insert the top of the DIN-Rail onto the track as shown below in Figure 4.

  2. Lightly pull down the bracket onto the rail as shown below in Figure 5.

  3. Check if the bracket is mounted tightly on the rail.
    antaira LMX 1202M SFP series 12 Port Industrial Managed Ethernet Switch -
Fig5

  4. To remove the industrial Ethernet switch from the rail, do the opposite from the steps above. Figure 3
    antaira LMX 1202M SFP series 12 Port Industrial Managed Ethernet Switch -
Fig6

Wall Mounting

Follow the steps below to mount the industrial Ethernet switch using the wall mounting bracket as shown below in Figure 6.

  1. Remove the DIN-Rail bracket from the industrial Ethernet switch by loosening the screws.
  2. Place the wall mounting brackets on the top and bottom of the industrial Ethernet switch.
  3. Use the screws to screw the wall mounting bracket on the industrial Ethernet switch.
  4. Use the hook holes at the corners of the wall mounting bracket to hang the industrial Ethernet switch on the wall.
  5. To remove the wall mount bracket, do the opposite from the steps above.
    antaira LMX 1202M SFP series 12 Port Industrial Managed Ethernet Switch -
Fig7

Field Maintenance and Service

  • If the device requires servicing of any kind, the user is required to disconnect and remove it from its mounting. The initial installation should be done in a way that makes this as convenient as possible.
  • Voltage/power lines should be properly insulated as well as other cables. Be careful when handling them so as to not trip over them.
  • Do not under any circumstance insert foreign objects of any kind into the heat dissipation holes located in the different faces of the device. This may not only harm the  internal layout but might cause harm to the user as well.
  • Do not under any circumstance open the device for a reason. Please contact your dealer for any repair needed or follow the instructions within the manual.

Warranty Policy

Warranty Conditions
Products supplied by Antaira Technologies are covered in this warranty for sub-standard performance or defective workmanship. The warranty is not, however, extended to goods damaged in the following circumstances:
(a) Excessive forces or impacts
(b) War or an Act of God: wind storm, fire, flood, electric shock, earthquake
(c) Use of unqualified power supply, connectors, or unauthorized parts/kits
(d) Replacement with unauthorized parts
RMA and Shipping Costs Reimbursement
Customers shall always obtain an authorized “RMA” number from Antaira before shipping the goods for repair or replacement.

  • Within the warranty period (based on the invoice date), all parts and labor are free of charge to the customers.
  • Customers are responsible for the cost of parts and labor if the products are out of warranty.
  • For RMA service, customers are responsible for the shipping expense for shipping the RMA unit(s) to Antaira. Antaira is responsible for the shipping expense via ground service for the return repair/replacement unit(s) back to customers.

Limited Liability
Antaira would not be held responsible for any consequential losses from using Antaira’s product.
Warranty Period
5-Year Warranty
Antaira’s Customer Service and Support

*Any changes will be announced on the Antaira website.

Tel: 1-844-268-2472
Fax: 1-714-671-9944
www.antaira.com

Documents / Resources

| antaira LMX-1202M-SFP series 12-Port Industrial Managed Ethernet Switch [pdf] Installation Guide
LMX-1202M-SFP series, 12-Port Industrial Managed Ethernet Switch, LMX-1202M- SFP series 12-Port Industrial Managed Ethernet Switch, Industrial Managed Ethernet Switch, Managed Ethernet Switch, Ethernet Switch
---|---

References