SEALEY SPBC8 Automatic Battery Charger and Maintainer Instruction Manual

June 4, 2024
SEALEY

SEALEY SPBC8 Automatic Battery Charger and Maintainer

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

SAFETY

ELECTRICAL SAFETY

  • WARNING! It is the user’s responsibility to check the following: Check all electrical equipment and appliances to ensure that they are safe before using. Inspect power supply leads, plugs and all electrical connections for wear and damage. Sealey recommends that an RCD (Residual Current Device) is used with all electrical products. You may obtain an RCD by contacting your local Sealey stockist. if the multi-tool is used in the course of business duties, it must be maintained in a safe condition and routinely PAT (Portable Appliance Test) tested. Electrical safety information. It is important that the following information is read and understood.
  • Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply.
  • Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.
  • Important: Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is fitted with the correct fuse – see fuse rating in these instructions.
1. DO NOT pull or carry the appliance by the power cable.
2. DO NOT pull the plug from the socket by the cable. Remove the plug from the socket by maintaining a firm grip on the plug.
3. DO NOT use worn or damaged cables, plugs, or connectors. Ensure that any faulty item is repaired or replaced immediately by a qualified electrician.
  • This product is fitted with a BS1363/A 13 Amp 3 pin plug. If the cable or plug is damaged during use, switch off the electricity supply and remove it from use. Replace a damaged plug with a BS1363/A 13 Amp 3 pin plug. If in doubt contact a qualified electrician. Class II products are wired with live (brown) and neutral (blue) only and are marked with the Class II symbol;
    • A) Connect the BROWN live wire to the live terminal ‘L’.
    • B) Connect the BLUE neutral wire to the neutral terminal ‘N’.
    • C) After wiring, check that there are no bare wires and ensure that all wires have been correctly connected.
  • Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight. DO NOT connect either wire to the earth terminal. Sealey recommends that repairs are carried out by a qualified electrician.

GENERAL SAFETY

  • DANGER! BE AWARE, LEAD-ACID BATTERIES GENERATE EXPLOSIVE GASES DURING NORMAL BATTERY OPERATION. FOR THIS REASON, IT IS VERY IMPORTANT TO READ AND FOLLOW THESE INSTRUCTIONS CAREFULLY, EACH TIME YOU USE THE CHARGING EQUIPMENT.
  • Follow these instructions and those published by the battery and vehicle manufacturer, and the maker of any equipment you intend to use in the vicinity of the battery. Remember to review warning marks on all products and on engines.
  • WARNING! Modern vehicles contain extensive electronic systems. You are required to check with the vehicle manufacturer, for any specific instructions regarding the use of this type o f equipment on each vehicle.
  • No liability will be accepted for damage/ injury, where this product is not used in accordance with all instructions.

PERSONAL PRECAUTIONS

  • Ensure there is another person within hearing range of your voice and close enough to come to your aid, should a problem arise when working near a lead-acid battery.
  • Wear safety eye protection and protective clothing. Avoid touching eyes while working near battery.
  • Have fresh water and soap nearby in case battery acid contacts skin, clothing or eyes.
  • Wash immediately with soap and water if battery acid contacts skin or clothing. If acid enters eye, flush eye immediately with cool, clean running water for at least 15 minutes and seek immediate medical attention.
  • Remove personal metallic items such as rings, bracelets, necklaces and watches. A lead-acid battery can produce a short-circuit current which is high enough to weld a ring or the like to metal, which would cause severe burns.
  • Ensure hands, clothing (especially belts) are clear of fan blades and other moving or hot parts of engine, remove ties and contain long hair.
  • DO NOT smoke or allow a spark or flame in the vicinity of battery or engine.

CHARGING SAFETY INSTRUCTIONS

  • Familiarise yourself with the application and limitations of the charger as well as the potential hazards. Also, refer to the vehicle manufacturer’s hand book. IF IN ANY DOUBT CONSULT A QUALIFIED ELECTRICIAN.
  • Ensure the charger is in good order and condition before use. If in any doubt DO NOT use the unit, contact your Sealey stockist.
  • Use the starter/charger in the upright position only and ensure it is placed on a stable surface that will adequately support its weight.
  • Ensure the charger is disconnected from the mains supply before attaching/detaching the power clamps to/from the battery.
  • Keep tools and other items away from the engine and ensure you can see the battery and working parts of engine clearly.
  • Ensure the output of the charger is the same voltage as the battery.
  • If battery has caps to access the battery fluid, remove the caps and check the fluid level before connecting the power clamps.
  • If necessary top-up the battery with distilled water by referring to the battery manufacturer’s instructions (Apply the personal safety precautions described in part 1.3).
  • If the charger receives a sharp knock or blow the unit must be checked by a qualified service agent before using.
  • If the battery terminals are corroded or dirty clean them before attaching the power clamps.
  • Keep children and unauthorised persons away from the working area.
  • DO NOT disassemble the charger for any reason. The charger must only be checked by qualified service personnel.
  • DO NOT try to charge a non-rechargeable battery.
  • DO NOT try to charge battery if battery fluid is frozen.
  • WARNING! To prevent the risk of sparking, short circuit and possible explosion DO NOT drop metal tools in the battery area, or allow them to touch the battery terminals.
  • DO NOT allow power clamps to touch each other or to make contact with any metallic part of the vehicle.
  • DO NOT cross-connect power leads from charger to battery. Ensure positive (+/RED) is to positive and negative (-/BLACK) is to negative.
  • DO NOT pull the cables or clamps from the battery terminals.
  • DO NOT use the charger outdoors, or in damp, or wet locations and DO NOT operate within the vicinity of flammable liquids or gases.
  • DO NOT use charger inside vehicle or inside engine compartment.
  • Ensure there is effective ventilation to prevent a build-up of explosive gases, and DO NOT cover or obstruct charger ventilation louvers.
  • DO NOT use the charger for a task for which it is not designed.
  • WARNING! DO NOT simultaneously charge batteries of different capacities or discharge levels.
  • WARNING! If a fuse blows, ensure it is replaced with an identical fuse type and rating. Use only Sealey genuine parts.
  • When not in use, store the charger carefully in a safe, dry, childproof location.
  • An extension cord should not be used unless absolutely necessary. Use of an improper extension cord could result in a risk of fi re and electric shock. If an extension cord must be used, make sure:
  • That the pins on the plug of the extension cord are the same number, size and shape as those of the plug on the charger.
  • That the extension cord is properly wired and in good electrical condition.
  • That the wire size is large enough for the AC ampere rating of the charger as specified.
  • To reduce the risk of electric shock, unplug the charger from the outlet before attempting any maintenance or cleaning. Simply turning off the controls will not reduce this risk.
  • A marine (boat) battery must be removed and charged on shore. To charge it on-board requires equipment specially designed for marine use.
  • CAUTION: Only allow children at least 8 years old to use the battery charger. Give sufficient instruction so that the child is able to use the battery charger in a safe way and explain that it is not a toy and must not be played with. Instruct the child not to try and recharge non-rechargeable batteries because of the risk of eruption. Examine the battery charger regularly for damage, it must not be used until it has been repaired. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning an user maintenance shall not be made by children without supervision.

INTRODUCTION

Fully automatic 7-stage battery charger, designed for charging and maintaining a variety of EFB & AGM (stop/start), GEL, lead acid and calcium batteries with auto chemistry selection. Zero volt battery charging, enabling recovery and charging of a completely discharged battery (providing any load removed from the rechargeable battery). Old battery sulfation repair function. Reverse polarity, short circuit, over temperature, and overcharging protection. The Intuitive LED screen displays illuminated charging stages, volts and amps output and battery capacity. Compact design with unique retractable hanging hook, and cable management system which allows the clips to be stored neatly away when not in use.

SPECIFICATION

MODEL :………………………………………………. SPBC8…………………………………………. SPBC12……………………………………..SPBC16
Supply :…………………………………………………….. 230V………………………………………………. 230V…………………………………………..230V
Output :…………………………………………….6V/12V/24V………………………………………6V/12V/24V…………………………………6V/12V/24V
Output Charge :………………. 8A @ 6/12V (4A @ 24V)………………….. 12A @ 6/12V (6A @ 24V)………………16A @ 6/12V (8A @ 24V)
Battery Range :…………………………….. 40Ah to 100Ah…………………………………. 40Ah to 160Ah……………………………. 40Ah to 200Ah
Cable Length :…………………………………………….1.2m………………………………………………..1.2m…………………………………………..1.2m
IP Rating :………………………………………………….. IP33……………………………………………….. IP33………………………………………….. IP33
Dimensions :………………….193mm x 183mm x 80mm…………………..193mm x 183mm x 80mm…………….. 193mm x 183mm x 80mm
Electrical Class :……………………………………………… 2……………………………………………………. 2………………………………………………..2
Electrical Fuse Rating :…………………………………. 13A………………………………………………… 13A…………………………………………….13A

OPERATION

  • WARNING! The charger does not have an on/off switch. The on and off commands are controlled by plugging the SPBC8, SPBC12, & SPBC16 with power supply into an AC electrical wall socket only after the battery connections have been made.

CHARGING PROCESS:

  1. Fully automatic 7-stage charging system:
  2. Analysis / Desulfation (Charging stage 1 illuminated) – A small voltage pulse is applied to the battery to ensure it can effectively and safely accept a charge. Desulfation uses pulse reconditioning to gently remove any sulfation buildup on the battery plates and prevent oxidization. Stabilizes electrolyte consistency and minimizes the battery temperature rising by charging, recovers battery capacity, and can help extend battery life.
  3. Soft Start (Charging stage 2 illuminated) – The soft start function improves the battery charging capability, reduces gas and heat build-up, and can improve electrolyte consistency which can become uneven in the battery cells from day to day use. A steadily increasing current is applied over a set time so as not to initially overload the battery. This stage prepares the battery for the more intense charging stages to follow.
  4. Bulk Charge (Charging stage 3 illuminated) – Maximum charge current is delivered to the battery to minimize charge times.
  5. Absorption (Charging stage 4 illuminated) – Reduces the current supplied to the battery and ensures that the battery has been completely charged without the risk of being overcharged.
  6. Analysis (Charging stage 5 illuminated) – The charger shuts off the power and measures voltage drop over a set time. If unacceptable readings are measured, this may indicate an internal short or another issue inside the battery. If the battery has a fault the charger will illuminate the Battery Error LED indicator. The charger will cut output and not continue to charge until it is either switched off, or the battery is removed.
  7. Boost / Equalisation charge (Charging stage 6 illuminated) – Once the battery is fully charged, the charger will equalize all the battery cells by providing a steady set voltage over a programmed period, at a low current.
  8. Float Stage(Charging stage 7 illuminated) – Once the battery is fully charged, the charger will provide a constant voltage of 6.85V/13.7V/27.4V to maintain the battery at a full level without damaging the battery.

TEMPERATURE COMPENSATION
This charger has a temperature compensation feature that will reduce the output current of the charger if the charger’s internal temperature exceeds its set limit. This protection feature will prevent the battery and charger from damage if the bulk stage takes an extended time – particularly if a larger than recommended battery has been connected. There is no indicator to show temperature compensation.
NOTE: The 6V/12V/24V, 8A/12A/16A fully automatic 7-stage battery charger is designed to effectively charge most automotive battery types including lead acid, calcium, maintenance-free, Gel and AGM. They are manufactured to the latest design parameters and highest quality levels. There are no buttons to decipher – the specially designed microprocessor charging system automatically selects the correct voltage and current setting and output levels for the size and type of the battery, greatly assisting prolonged battery life and user safety. Please adhere to all safety directions in this manual and retain for later use.

IMPORTANT SAFETY INSTRUCTIONS

  1. Battery chargers contain hazardous voltages. There are no user-serviceable components inside the charger. DO NOT disassemble this product.
  2. If the mains cable is broken or damaged, it must be replaced by a qualified person only.
  3. This battery charger is for use with 6, 12, and 24V electrical systems only. Care should still be taken to correctly identify the correct voltage on vehicles and light trucks BEFORE the battery charger is connected and switched on.

BATTERY CHARGER OPERATION

  1. This charger has been designed to be as simple to use as possible. As a result, there are no input buttons or any other selections to make. The charger has an advanced on board micro-processor that will take care of every setting required.

TO COMMENCE BATTERY CHARGING:

  1. Unwind both 240V and 12V power leads from the rear of the charger.
  2. Connect the Red POSITIVE (+) clamp to the battery Red POSITIVE (+) terminal.
  3. Connect the Black NEGATIVE (-) clamp to the Black NEGATIVE (-) terminal.
  4. Plug in the mains power cable, and switch on the power.
  5. The charger will take approximately 1 minute to complete its voltage diagnostics to detect the correct battery voltage, once complete the correct LED will illuminate for 6, 12 or 24V operation.
  6. Charging will now commence automatically.
  7. View the status LED indicators on the front panel to see progress.
  8. Once the TOP GREEN LED bar in the display indicator illuminates, the battery is fully charged and may be disconnected from the battery charger clamps.

TO DISCONNECT:

  1. Switch off mains power and unplug the power cable.
  2. Disconnect the Black NEGATIVE (-) clamp from the Black NEGATIVE (-) terminal.
  3. Disconnect the Red POSITIVE (+) clamp from the battery Red POSITIVE (+) terminal**
  4. Re-attach battery terminal protective covers if previously removed.
  5. Rewind both 240V and 12V power cables back into the rear of the charger for storage.

MAINTENANCE

WARNING! After use and before performing maintenance, unplug and disconnect the battery charger.

  1. Cleaning and user maintenance should be carried out by competent persons.
  2. Use a dry cloth to wipe all battery corrosion and other dirt or oil from the battery connectors, cords, and charger case.
  3. Ensure that all of the charger components are in place and in good working condition, for example, the plastic boots on the battery clips.
  4. Servicing does not require opening the unit, as there are no serviceable parts.
  5. All other servicing should be performed by qualified service personnel.
  6. If the mains cable is damaged, DO NOT use it until repaired.
  7. Store the charger unplugged, in an upright position. The cord will still conduct electricity until it is unplugged from the mains.
  8. Store inside, in a cool, dry place.
  • DO NOT store the connectors clipped together, on or around metal, or clipped to cables. If the charger is moved around the shop or transported to another location, take care to avoid/prevent damage to the cables, connectors, and charger. Failure to do so could result in personal injury or property damage.

ENVIRONMENT PROTECTION

Recycle unwanted materials instead of disposing of them as waste. All tools, accessories, and packaging should be sorted, taken to a recycling center, and disposed of in a manner that is compatible with the environment. When the product becomes completely unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids according to local regulations.

WEEE REGULATIONS

Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment (WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid waste authority for recycling information.
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications, and component parts without prior notice.
Important: No Liability is accepted for incorrect use of this product.

Warranty

The guarantee is 60 months from the purchase date, proof of which is required for any claim.

Address:

Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR 01284 757500 01284 703534 sales@sealey.co.uk www.sealey.co.uk

Read User Manual Online (PDF format)