SAFETY PRECAUTIONS
- Before installation or use, be sure to carefully read all the instructions in this section for correct and safe operation.
- Be sure to follow all the precautionary instructions in this section, which contain important warnings and/or cautions regarding safety.
- After reading, keep this manual handy for future reference.
CAUTION Indicates a potentially hazardous situation which, if mishandled, could result in moderate or minor personal injury, and/or property damage.
- Do not connect the speaker line to the contact output as doing so may result in fire or electric shock.
- As up to 100 V is applied to the CN 1 terminal, never touch its terminal to avoid electric shock.
- Leave all cable connections on the unit to a professional electrical contractor.
GENERAL DESCRIPTION
VM-3000 detects speaker line short circuits and open circuits by monitoring
the terminated resistance value of the End-of-line (EOL) module.
Connecting the VM-300SV unit to the end of the speaker line eliminates the
necessity of using the speaker line for line monitoring.
Note: This unit can only be used on a VM-3000 system with a firmware of 2.00 or later.
HANDLING PRECAUTIONS
- Do not install the unit in locations exposed to the direct sunlight or heaters, as the unit could be deformed or discoloured.
- Avoid installing or storing the unit in dusty or humid locations, as doing otherwise could cause the unit’s failure.
- Keep a unit as far away as possible from a fluorescent lamp, digital equipment, PC or other equipment which generate high frequency noise.
- Because the unit is not “hot-pluggable,” the system needs to be shut down when it is installed or removed.
- Note correct polarity (positive and negative orientation) when connecting Contact output.
Reserved polarity connections will cause failure.
CONNECTION
SPECIFICATIONS
Power Source | Supplied from VM-3240VA/3360VA/3240E/3360E |
---|---|
Power Consumption | 0.2 W |
Speaker Line Input (CN 1) | Screw connector, Applicable cable diameter: AWG 24 |
– AWG 19
Contact Output (CN 2)| Connected to the emergency contact input of VM-
3240VA/3360VA/3240E/3360E
Connection cable: Twisted pair cable (shielded type is recommended) Screw
connector, Applicable cable diameter: AWG 24 – AWG 19
Speaker Line| Max. load: 100 W
Note: applicable only to 100 V speaker line
Dimensions| 70 (w) x 18 (h) x 45 (d) mm (2.76″ x 0.71″ x 1.77″)
Weight| 20 g (0.71 oz)
Note: The design and specifications are subject to change without notice for improvement.
Traceability Information for UK
Manufacturer:
TOA Corporation
7-2-1, Minatojima-Nakamachi, Chuo-ku, Kobe, Hyogo, Japan
Authorized representative:
TOA CORPORATION (UK) LIMITED Unit 7&8, The Axis Centre, Cleeve Road,
Leatherhead, Surrey, KT22 7RD, United Kingdom
Traceability Information for Europe
Manufacturer:
TOA Corporation
7-2-1, Minatojima-Nakamachi, Chuo-ku, Kobe, Hyogo,
Japan
Authorized representative:
TOA Electronics Europe GmbH Suederstrasse 282, 20537 Hamburg, Germany
URL: https://www.toa.jp/
133-02-00624-00