Miele PFD 104 SCVi Dishwasher Installation Guide

June 4, 2024
Miele

Miele PFD 104 SCVi Dishwasher

Installation notes

For safe installation and commissioning of the dishwasher please read the installation plan, the service documentation, the installation diagram, and the operating instructions. This installation plan includes the dimensions of the appliance, the technical data, and the requirements to be met on site for the installation of the dishwasher.

Installation requirements
Installation and commissioning work should be performed by a qualified and trained service technician in accordance with local and national safety regulations. Installation must comply with all local codes and regulations.

Surrounding area
Condensate can build up in the area surrounding the dishwasher. Any cabinetry and fittings in the room must, therefore, be suitable for this purpose.
Vapor-barrier film for built-in appli-ances
The vapor-barrier film supplied with the dishwasher protects the countertop from damage caused by steam when the door is opened. Attach the vapor-barrier film above the door, underneath the counter-top.
Electrical connec-tion
All work on the electrical connection should be carried out by Miele Customer Service, an authorized Miele dealer, or a qualified electrician.
Plug Connection
The dishwasher should be connected to the electricity supply via an electrical outlet.
Hard-wired
If the dishwasher is hard-wired to the power supply, a circuit breaker capable of disconnecting the dishwasher at all poles must be installed on- site. This power switch must have a contact gap of at least 1/8″ (3 mm). The electrical socket outlet and the circuit breaker must be accessible after the appliance has been installed. This is to enable an electrical safety test to be carried out after installation and after any servicing work. The power cord must be laid protected from the risk of thermal damage.

Equipotential bonding and grounding
This machine must be grounded in accordance with the local code.

Water connection
Before connecting the dishwasher or immediately the following disruption in the water supply pipe must be vented from air pockets to avoid pressure surges that may destroy components in the dishwasher.

Water intake
The quality of the incoming water must comply with the requirements for drinking water in the country in which the dishwasher is being operated. The dishwasher must be connected to the water supply in strict accordance with current local and national water authority regulations. It can be connected to cold or hot water supplies. Connecting the dishwasher to a hot water supply will reduce program cycle times. For short program cycle times, the water pressure of at least 29 psi (200 kPa) is also required. If this type of shut- off valve is not available, only a qualified installer may connect the dishwasher to the domestic water supply. The shut-off valve should remain accessible once the dishwasher has been installed so that the water supply can be shut off whenever the appliance is not in use.
Drainage

The dishwasher drainage hose should be connected to a separate on-site drain for the dishwasher only. If no separate drain is available, we recommend connecting it to a dual chamber siphon. When using a drain loop additional backflow prevention is not required. If the hose is to be directly connected to the drainage outlet on-site, use the hose clip supplied with the dishwasher. The on-site connector for the drain hose can be used for various hose diameters. If the connector extends more than 1″ (30 mm) into the drain hose, it must be shortened. Otherwise, the drain hose can become clogged. Lay the drain hose so that it does not kink and is not subjected to pressure or tugged. If the on-site drain connection is situated lower than the guide path for the lower basket rollers in the open door, a siphoning effect during a program can cause the appliance to empty itself of water. In this case, lay the drain hose with a bend in it so that its highest point is at least level with the guide path for the lower basket rollers.

Appliance dimensions and installation dimensions

Undercounter appliance

PFD 101 UMiele-PFD-104-SCVi-Dishwasher-FIG-1

Built-in appliance

PFD 102 iMiele-PFD-104-SCVi-Dishwasher-FIG-2

Front panel dimensions

Length 19.7″–25.7″ 500–654 mm
Thickness 0.63″–0.79″ 16–20 mm
Weight 8.8–24.3 Ibs 4–11 kg

Fully integrated appliance

PFD 104 SCViMiele-PFD-104-SCVi-Dishwasher-FIG-3

Front panel dimensions

Length 27.2″–31.9″ 690–810 mm
Thickness 0.63″–0.79″ 16–20 mm
Weight 11–26.5 lbs 5–12 kg

Connections on the back of the appliance

Miele-PFD-104-SCVi-Dishwasher-
FIG-4

On-site connectionsMiele-PFD-104-SCVi-Dishwasher-
FIG-5

  1. Electrical connection
  2. Equipotential bonding and grounding
  3. Wastewater
  4. Cold or hot water

Technical details

Dimensions and weights|
---|---
| | PFD 101 U| PFD 102 i| PFD 104 Vi
Height| [inches]| 31.7| 31.7| 33.3
| [mm]| 805| 805| 845
Height adjustment| [inches]| 2.56| 2.56| 2.56
| [mm]| 65| 65| 65
Width| [inches]| 23.5| 23.5| 23.5
| [mm]| 598| 598| 598
Depth| [inches]| 22.4| 22.4| 22.4
| [mm]| 570| 570| 570
Depth with door open| [inches]| 45.9| 45.9| 47.4
| [mm]| 1165| 1165| 1205
Max. toe-kick return| [inches]| 4.53| 4.53| 4.53
| [mm]| 115| 115| 115
Weight| [ibs]| 97| 92.6| 112
| [kg]| 44| 42| 51
Max. floor load| [N]| 1000| 1000| 1000
Emission levels| | | |
| | PFD 101 U| PFD 102 i| PFD 104 Vi
Sound power level| [dB(A)

re 1 pW]

| 48| 48| 45
The sound pressure level in the workplace| [dB(A)]| 35.1| 35.1| 31.4
Electrical connection the USA|
---|---
PFD 101 U
| Standard electrical connection| Possible voltage **variant***
Voltage| AC 120 V| 2N AC 120/208–240 V
Frequency| 60 Hz| 60 Hz
Fuse rating| 15 A| 2 x 30 A
Plug| 5–15P NEMA| 14–30P NEMA
Power cord length| 5.6 ft/1.7 m| 5.6 ft/1.7 m
Power cord cross-section| 3 x AWG14| 4 x AWG10
Heat output| 1.3 kW| 3.5–3.8 kW
Total rated load| 1.4 kW| 3.7–4 kW

  • The conversion can be done by Miele Service.| |
    PFD 102 i and PFD 104 SCVi| |
    | Variant 1| Variant 2
    Voltage| AC 120 V| 2N AC 120/208–240 V
    Frequency| 60 Hz| 60 Hz
    Fuse rating| 15 A| 2 x 30 A
    Plug| 5–15P NEMA| 14–30P NEMA
    Power cord length| 5.6 ft/1.7 m| 5.6 ft/1.7 m
    Power cord cross-section| 3 x AWG14| 4 x AWG10
    Heat output| 1.3 kW| 3.5–3.8 kW
    Total rated load| 1.4 kW| 3.7–4 kW
    Electrical connection Canada| |
    ---|---|---
    PFD 101 U| |
    | Standard electrical connection| Possible voltage **variant***
    Voltage| AC 120 V| 2N AC 120/208–240 V
    Frequency| 60 Hz| 60 Hz
    Fuse rating| 15 A| 2 x 30 A
    Plug| 5–15P NEMA| 14–30P NEMA
    Power cord length| 5.6 ft/1.7 m| 5.6 ft/1.7 m
    Power cord cross-section| 3 x AWG14| 4 x AWG10
    Heat output| 1.3 kW| 3.5–3.8 kW
    Total rated load| 1.4 kW| 3.7–4 kW
  • The conversion can be done by Miele Service.| |
    PFD 102 i| |
    | Variant 1| Variant 2
    Voltage| 2N AC 120/208–240 V| AC 120 V
    Frequency| 60 Hz| 60 Hz
    Fuse rating| 2 x 30 A| 15 A
    Plug| 14–30P NEMA| 5–15P NEMA
    Power cord length| 5.6 ft/1.7 m| 5.6 ft/1.7 m
    Power cord cross-section| 4 x AWG10| 3 x AWG14
    Heat output| 3.5–3.8 kW| 1.3 kW
    Total rated load| 3.7–4 kW| 1.4 kW

PFD 104 SCVi

| |
| Standard electrical connection| Possible voltage **variant***
Voltage| 2N AC 120/208–240 V| AC 120 V
Frequency| 60 Hz| 60 Hz
Fuse rating| 2 x 30 A| 15 A
Plug| 14–30P NEMA| 5–15P NEMA
Power cord length| 5.6 ft/1.7 m| 5.6 ft/1.7 m
Power cord cross-section| 4 x AWG10| 3 x AWG14
Heat output| 3.5–3.8 kW| 1.3 kW
Total rated load| 3.7–4 kW| 1.4 kW

  • The conversion can be done by Miele Service.

Water intake

Max. water temperature 140 °F 60 °C
Max. water hardness 6.5 mmol/l
Max. water hardness 37.5 gr/gal
Water connection pressure 5 – 1000 a
On-site threaded connection (flat seal) 3/4″ Hose thread
Connection hose length 4.9 ft 1.5 m
Connection hose extension * 4.9 ft 1.5 m
  • Optional accessory

Max. water temperature: 180 °F: 82 °C

Drain hose length: 4.9 ft: 1.5 m

Max. drain hose length: 13 ft: 4 m

Max. drain height: 3.3 ft: 1 m

Max. transient flow rate: 0 l/min

Hose inner diameter: 0.87″: 22 mm

On-site hose sleeve (x length): 0.87″ x 1.18″: 22 x 30 mm

Operating conditions

Ambient temperature +41 – +104 °F +5 – +40 °C

Relative humidity:

Up to 88 °F (31 °C), maximum

| | ****

80 %

|
Linear decreasing to 104 °F (40 °C)| | 50 %|
Max. altitude above sea level up to| 13,123 ft| | 4,000 m

Storage and transportation conditions

Ambient temperature: -4 – +140 °F: -20 – +60 °C

Relative humidity: 10–85 %

Air pressure: 500–1060 hPa

Min. site access dimensions including transport pallet

Height 38.2″ 970 mm
Width 26.4″ 670 mm
Depth 26.4″ 670 mm

Please have the model and serial number of your machine available when contacting Technical Service.

USA

Miele, Inc.
National Headquarters
9 Independence Way
Princeton, NJ 08540
Phone: 800-991-9380
www.mieleusa.com/professional
prosales@mieleusa.com
Technical Service & Support
Phone: 800-991-9380
proservice@mieleusa.com

Canada

Importer | Importateur
Miele Limited | Limitée
Professional Division
161 Four Valley Drive
Vaughan, ON L4K 4V8
Phone | Tél. : 1-888-325-3957
www.mieleprofessional.ca