PREFACE
Thank you very much for purchasing our product. Please read this manual carefully before assembling and save it afterwards. Please write down the control box serial number of the cabin as this number will be required in case of repair or order of spare parts.
ATTENTION
Installation and repair should only be done by a qualified electrician! Check power supply rating and make sure the grounded outlet is correctly connected before installation. Use original parts only. Do not share the outlet with any other appliances. When not in use, turn off the cabin’s power unit. Locate your cabin indoors and on a flat, level and dry surface.
DANGER
Heaters shall not be subjected to water spray; shower heads shall not be installed within the infrared cabin. Covering the radiator causes a fire hazard due to overheating. Do not cover the heaters ! Keep flammable or easily combustible materials/objects (eg.towels) away from the radiator at all times. Do not touch the radiator during and shortly after use as a burning hazard exists due to hot parts. The light bulb heats in use. If the bulb needs to be changed, unplug the cabin and let the bulb cool down before changing it. Should the electrical connection get damaged, it must be replaced-either by the manufacturer or by a licensed electrician!
WARNING
If you suffer from illness or other health-related problems, especially heart conditions or circulatory disturbances or if you take medication, you should consult a doctor before using the infrared cabin. Children and frail persons should never be in the cabin without supervision. If you feel uncomfortable while using the infrared cabin, stop immediately and consult with your doctor. Never go to a hot infrared cabin if you have taken alcohol, strong medicines or narcotics.

Technical data

Model Eclipse-A17
Cabin material Regular hemlock
Length 2043 mm
Width (depth) 2008mm
Height 2055 mm
Voltage 230volt 50Hz
Radiators Type
Total output 2800W      12.2 A
Back panel 350W x 3
Side panel 350W x 3
Calves 350W x 2

PARTS LIST

Wellis ECLIPSE HEML Eclipse Hemlock Combined Sauna -
fig1

Cabin Individual parts (variations possible

NO NAME Q’ TY Box No
1 Back panel 1 (1988119043. 5mm) 1 1
2 Back panel 2 (198889043. 5mm) 1 2
3 connecting bar 1 (19089020mm) 1 1
4 Side panel 1 (1995.5119048mm) 1 1
5 Side panel 2 (1995.589048mm) 1 3
6 connecting bar 2 (12709020mm) 1 1
7 Upright column 1 (20509040mm) 1 2
8 Upright column 2 (20509040mm) 1 2
9 Door cross beam (lower, 18636040mm) 1 2
10 Side cross beam (lower, 18206040mm) 1 2
11 Front upright column (20509040mm) 1 2
12 Front glass (19206516mm) 1 4
13 Front glass (with hole,19206516mm) 1 4
14 Side glass (19208836) 2 4
NO NAME Q’ TY Box No
--- --- --- ---
15 Side upright column(19009040mm) 1 2
16 Door cross beam (upper, 186310540mm) 1 2
17 Side cross beam (upper, 19419040mm) 1 2
18 Top decorative bar 1 (19593030mm) 2 2
19 Top decorative bar 2 (18563030mm) 2 2
20 Top panel 1 (195896740.5mm) 1 3
21 Top panel 2 (195896740.5mm) 1 3
22 Bench support panel 1(100092548mm) 1 3
23 Bench support panel 2(92560048mm) 1 1
24 Calves guardrail (67025043mm) 2 3
25 Bench support panel 3(with hole,19109040mm) 1 2
26 Bench support panel 4(with hole,12739040mm) 1 2
27 Bench support panel 5(19109040mm) 2 2
28 Bench surface panel 1(191060033mm) 1 1
29 Bench surface panel 2(191040033mm) 1 1
30 Bench surface panel 3(126760033mm) 1 1
31 Back guardrail (195864354mm) 1 2
32 Side guardrail (186164354mm) 1 2
33 Floor panel (96689033mm) 1 2
34 Glass door (18885726mm) 1 4
35 Door handle (3004045mm) 2 2
36 MDF cover (19589673mm,19589473mm) 2 3

Hardware parts (variations possible)

Wellis ECLIPSE HEML Eclipse Hemlock Combined Sauna -
fig2

ASSEMBLE INSTRUCTIONS

Assemble tips
Please remove transport packaging and inspect that your infrared cabin has been delivered complete and intact before beginning assemble. A least 2 persons are required for assemble of the cabin Please check the countersink and hole diameter of the drill holes to avoid damaging the wood.. The minimum room height required for installation is 2250mm
Tools

Wellis ECLIPSE HEML Eclipse Hemlock Combined Sauna -
fig3

Assemble steps

Wellis ECLIPSE HEML Eclipse Hemlock Combined Sauna -
fig4

Wellis ECLIPSE HEML Eclipse Hemlock Combined Sauna -
fig5

Wellis ECLIPSE HEML Eclipse Hemlock Combined Sauna -
fig6

Wellis ECLIPSE HEML Eclipse Hemlock Combined Sauna -
fig7

Wellis ECLIPSE HEML Eclipse Hemlock Combined Sauna -
fig8

Wellis ECLIPSE HEML Eclipse Hemlock Combined Sauna -
fig9

Wellis ECLIPSE HEML Eclipse Hemlock Combined Sauna -
fig10

Rubber strip 2: The rubber on the handle side is placed on the door panel, with the wide part of the rubber facing outwards. The rubber on the hinge side is placed on the fixed glass pane, with the wide part of the rubber facing outwards.

Wellis ECLIPSE HEML Eclipse Hemlock Combined Sauna -
fig11

The sauna stove must always be placed in the corner, to the right of the glass door. For this model, the stove must be mounted on the protective grid. Make sure that the minimum required distances are observed (see the sauna stove instructions or sauna stove data plate.)

Sauna stones

Since the sauna stones may be dusty,we recommend that they should be rinsed before being loaded into the heater container.
The sauna stones should be placed in such a way that the smaller stones are first placed between the heating elements and then the large stones on top of them. Make sure that the smaller sauna stones placed at the bottom will provide support for the large sauna stones and won’t put weight on the heating elements. This will prolong the life of the heating elements.
Do not load the stones too tight so that air can easily move between the stones whereby a good even cooling can be got for the heating elements. Reload when stones broken or crumbling so that these stones can be got out of the heater before the heating elements get damaged. The diameter of the stones is usually of 5-10 cm.

Sand timer and Thermo-hygrometer

The thermometer should be placed at a height of 180 cm from the floor level, preferably on the column next to the stove. Under no circumstances should the thermometer be placed above the stove. The hourglass should be placed on the same column, below the thermometer.

Wellis ECLIPSE HEML Eclipse Hemlock Combined Sauna -
fig13

Fix the humidity meter with the appropriate screw on the side wall.

CIRCUIT DIAGRAM

Wellis ECLIPSE HEML Eclipse Hemlock Combined Sauna -
fig14

OPERATING INSTRUCTIONS

Wellis ECLIPSE HEML Eclipse Hemlock Combined Sauna -
fig15

ON/OFF
Color light
Temperature setting
Time setting
Time/Temperature+
Time/Temperature—

Connect the power unit to wall outlet, the LED indicator will start to blink on the display. Now it is possible to switch on the infrared heaters, the light and the music function.

  1. Startup
    Press to switch on the display and heaters start to work, the length of time is automatically set to 99 minute and the air temperature inside the cabin will be presented. Press again could switch off the heaters.

  2. Temperature settings
    The left display refers to the air temperature. Press you can set the desired temperature from 35°C to 60% by pressing the / keys, Interval=1°C; The setting number blinks 10 seconds then automatically presents the air temperature; When at this temperature, the heaters will stop working automatically; When it fall 2°C below this temperature, the cabin will start up automatically. Please note: The maximum air temperature reachable in the cabin may be lower than the desired temperature. This is dependent on the temperature outside the cabin. Default temperature=40°C

  3. Time settings
    The right display refers to the length of time. Press , you can set the desired time from 5mins to 99mins by pressing the / keys: Interval=lmins; When count down to 00, the heaters will shut off automatically. Default time=99minutes.

  4. Color light
    Short press ,you can set the desired color (7 color totally)and close the light; Long press to go into an automatically cycling mode, changing 7 colors every 5 seconds.

  5. Mp3 player
    Long press ” M ” to activate the MP3 player. You can select the mode by short pressing the “ M “button:
    USB—Bluetooth—FM radio

USB or Bluetooth mode:
You can select songs by short pressing the keys and adjust the volume (0-32) by long pressing The . keys. The key for pause.
FM radio mode: Long press to search stations (87.5MHZ-108MHZ) automatically, the system will save all of them; You can select stations by short pressing the 1 keys and adjust the volume (0-32) by long Pressing the   keys. The key for mute Mind.

SERVICE

Use instructions
Drink plenty of liquids before and after use of the infrared cabin.
Dry yourself off completely.
The optimal cabin temperature for a pleasant session lies between 35 and 60t.
After a heating period of an hour at the latest, the cabin should be switched off and a heating brake of at least 30 minutes should be taken.
It is recommended to take a warm shower and relax after use.
Maintenance instructions
Clean the cabin with a damp cotton towel, dry with a clean dry towel.
Clean the glass with a window/glass cleaner and a soft cloth.
Do not pour water in the control panel or clean it with wet cloth. For cleaning purposes, use a cleaning cloth that has been only slightly moistened with a mild soapy solvent (dish detergent).
Do not use chemical detergents to clean the cabin. Please fasten the screws of the bench once every three months, avoid the loose or drop off.
Notes:
SERVICE
GUARANTEE CARD
Eclipse Hamlock infrared sauna
Heater:TRuby halogen tube radiator
Wood: Regular hemlock
Elektronik Recycling!
230V 50Hz∼2800W
**** Serien-Nr.:
Serial No:
Fill in this form and make a picture of it and Email to:
Date of purchase:
Serial Number:
Reference number:
Name :
Article state (unopened, just opened or used):
Please encircle on picture below which heater or which panel has a fault.
Attach pictures of the problem and send them through email.

Wellis ECLIPSE HEML Eclipse Hemlock Combined Sauna -
fig17

Wellis - logo


Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals