FRICO 125-42B Ribbed Pipe Radiator Instruction Manual
- June 13, 2024
- FRICO
Table of Contents
FRICO 125-42B Ribbed Pipe Radiator
Dimensions
Minimum distances
Accessories
Ribbed pipe radiator
Ecodesign Regulation (EU) 2015/1188 concerning local space heaters does not apply to all application areas. The Regulation applies when an installation is intended to provide thermal comfort for people in the premises. The Regulation does not apply to heating installations of a more technical nature e.g. in engineering/utility rooms, in production processes, frost protection, etc. The Regulation also does not apply to installations in vehicles, offshore or outdoors. Many of Frico’s products can be used as both local space heaters (as defined in (EU) 2015/1188) and for technical heating purposes. It is up to the installer responsible for the installation to assess whether the Ecodesign Regulation is applicable or not. Control solutions for installations not covered by the Ecodesign Regulation are listed in a separate table.
Controls
Type HxWxD [mm]
- TAP16R 87x87x53
- TEP44 87x87x55
- RTX54 82x88x25
Controls for installations not covered by the Ecodesign Regulation (EU) 2015/1188
Type HxWxD [mm]
- KRT1900 165x57x60
- KRT1901 165x57x60
- KRTV19 165x57x60
Technical data
Ribbed pipe radiator 125 IP44
Tekniska data Kamrörsradiator Typ|
125 IP44
Effekt [W]
|
Spänning [V]
|
Vikt [kg]
| | Technical data
Ribbed pipe radiator 125 IP44
Type Output
[W]
|
Voltage [V]
|
Weight [kg]
---|---|---|---|---|---|---|---
125- 12B| 200| 230V~| 2,4| | 125- 12B ** 200| 230V~| 2.4
125- 22B| 375| 230V~| 3,3| | 125- 22B ** 375| 230V~| 3.3
125- 32B/W/G| 575| 230V~| 4,5| | 125- 32B/W/G ** 575|
230V~| 4.5
125- 42B/W/G| 755| 230V~| 5,5| | 125- 42B/W/G ** 755|
230V~| 5.5
125- 52B/W/G| 1150| 230V~| 7,5| | 125- 52B/W/G ** 1150|
230V~| 7.5
Kamrörsradiator 127. För brandfarliga rum Ribbed pipe
radiator 127. For rooms where there is (sandfyllda). IP44 risk of fire
(sandfilled). IP44
Typ| Effekt| Spänning| Vikt| | Type| Output|
Voltage| Weight
| [W]| [V]| [kg]| | | [W]| [V]| [kg]
127- 22B| 500| 230V~| 10,9| | 127- 22B| 500| 230V~| 10.9
127- 42B| 800| 230V~| 33,3| | 127- 42B**| 800| 230V~| 33.3
Wiring diagrams
Control by thermostat, 125-12B, 125-22B, 125-32B/W/G, 125-42B/W/G and 127-22B
Control by thermostat, 125-52B/W/G and 127-42B
Control by thermostat, 125-12B, 125-22B, 125-32B/W/G, 125-42B/W/G and 127-22B. Controls for installations not covered by the Ecodesign Regulation (EU) 2015/1188.
Control by thermostat, 125-52B/W/G and 127-42B. Controls for installations not covered by the Ecodesign Regulation (EU) 2015/1188.
Main office
Frico AB
Tel: +46 31 336 86 00
Industrivägen 41
mailbox@frico.se
Swedenwww.frico.net
For latest updated information and information about your local contact: www.frico.net
References
Read User Manual Online (PDF format)