FOBA A-300 Column Stand with Base User Manual
- June 13, 2024
- FOBA
Table of Contents
FOBA A-300 Column Stand with Base
Intended use
- The intended purpose of the column stand is to stably position and hold a camera or optical device with an appropriate weight. The movable axes are controlled by hand and must always be locked in place.
- The locks on the stand axes are intended to fix the position, not to slow down movement. While in use and in storage, the brakes on all the base’s castors rust be engaged.
- Please only use the column stand indoors and on a flat and smooth floor. Ensure that the surroundings are free of debris to prevent damage and malfunction.
Clarification
- Devices and accessories mounted on the column stand do not represent integral components of the column stand.
Safety instructions
The column stand was designed by FOBA AG to minimize the chance of injury if used properly and in accordance with its intended use. Users are responsible for familiarising themselves with this manual and correctly implementing its contents.
- Never exceed the maximum specified load of the column stand. See last page of this manual.
- The horizontal arm can unexpectedly jump upwards. Only adjust the vertical axis once a suitable weight(camera or optical device) has been mounted on the column stand.
- Lock all movable axes once these have been positioned.
- Only employ original accessories and spare parts from FOBA AG and use these as per their intended purpose.
- Each time you use the column stand, make sure that it is in good condition.
- Please make sure that there is adequate room around the column stand before you move it.
- Never stand beneath any part of the column stand.
- The stand can tip over. Only use the column stand on level ground.
Disclaimer
Users are responsible for familiarising themselves with this manual and correctly implementing its contents. Users are legally liable for any damage if they.
- Use the stand beyond the scope of its intended use
- Fail to comply with the safety instructions
- Improperly assemble, repair, or maintain the stand
- Use accessories or spare parts other than genuine FOBA parts
- Modify the construction of the column stand
Disposal
Please dispose of all packaging materials and dismantle parts properly.
- Contact your local authority for information on correct disposal.
- The counterweights within the vertical column are made of lead.
Key functions
- Locking mechanism for vertical movement
- Locking mechanism for horizontal movement
- 3/8″ camera screw
- Castor brakes
Scope of delivery
- lx Column unit with a crosspiece
- lx Horizontal arm
- lx 5 mm Allen key
- lx Base
- 3x M8 cylinder screw
- lx 6 mm Allen key
Assembly Instructions
- Place the base on level ground and engage the brakes on all castors. Please ensure that you have sufficient space to assemble the column stand
- Make sure that the crosspiece is locked in the lowest position and that the cord remains taut. Ensure that the cord is placed correctly in the guide pulleys at the top of the column unit.
- Place the bottom end of the vertical column into the recess of the base. After this, erect the vertical column. Prevent the vertical column from tipping over until it has been secured correctly in place. This step should be carried out by at least two people.
- The column unit can only be mounted in the orientation shown. Rotate the column unit until it is correctly positioned in the base recess. Secure the vertical column in the stand base with the M8 screws supplied. This step should be carried out by at least two people.
- Release the brake of the horizontal arm.
- Slide the horizontal arm through the crosspiece in the direction shown. The scale should be visible from above.
- Engage the locking mechanism of the horizontal arm.
- Mount the camera plate at the end of the horizontal arm using the M6 screws provided.
Initial operation
- Perform the following checks each time before using the column stand.
- Inspect the cord for damage. Make sure that the cord is correctly positioned in the guide pulleys at the tip of the column stand. Movement of the cord outside the guide pulleys may damage it.
- If the column stand’s cord is damaged, it must be replaced immediately. Never use the column stand if the cord has been damaged.
- Please also check that all the axes can move smoothly and cleanly.
Transport and storage
- Before dismantling the column stand, always return it to the transport position as described in step 2 of the assembly instructions. This is the only way to prevent the counterweight within the vertical column from moving in an unchecked manner.
- Disassemble the column stand by following the assembly instructions in reverse order.
Adjustment and maintenance
adjusting the cord length
- Detach the camera plate at the end of the horizontal arm.
- Remove the horizontal arm from the column stand
- Ensure that the brakes on all castors are engaged and then tilt the column stand. When doing so, place the tip of the column stand on a chair (or the equrvalent). This step should be carried out by at least two people.
- Remove the central cover. Loosen the cord clamp to adjust the cord length as required. Re-tighten the cord clamp again straight away. Always mount the cord clamp as shown in the illustration.
adjusting the bearings
- If you notice there is minor play when moving the horizontal axis, you can adjust the bearings to resolve this You should always be able to move the column stand’s axes with no noticeable resistance. An overly tight setting can damage the coating.
further information please visit www.foba.com/support for further information. The column stand’s serial number is located below the central cover.
FOBA AG Friedgrabenstrasse 21 CH-8907 Wettswil / Switzerland +41 44 701 90 00 www.foba.com info@foba.com
Maximum Loads
Documents / Resources
| FOBA
A-300 Column Stand with
Base
[pdf] User Manual
A-300, A-300 Column Stand with Base, Column Stand with Base, Stand with Base,
Base
---|---
References
Read User Manual Online (PDF format)