Product Information
The product is an infrared heater available in two types: IHW with wide heat distribution (IP44) and IHF with directed heat distribution (IP44). It comes in three different models: IHW10, IHW15, and IHW20 for wide heat distribution, and IHF10, IHF15, and IHF20 for directed heat distribution. The heaters have different heat output options ranging from 1000W to 2000W. They operate at a voltage of 230V~ and have an amperage ranging from 4.3A to 8.7A. The length of the heaters varies from 500mm to 676mm, and the weight ranges from 1.9kg to 2.5kg.
Product Usage Instructions
- Position the heaters so that they can heat from at least two directions for even heating.
- Ensure a minimum mounting distance of 200mm for IHE and 180mm for IHW from the ceiling.
- Avoid placing the heaters near flammable materials.
- To replace the lamp, follow the steps outlined in the separate manual.
- Refer to the separate manual for information on accessories such as IHUB, IHXH, IHT, IHTW, IHP, KLS1KS, IHAF, IHL1000, IHL1500, IHL2000.
- For controls such as IHBD3 and CBT, refer to the separate manual for instructions.
Note: For detailed technical specifications and wiring diagrams, please
refer to the user manual in your respective language.
The introduction pages consist mainly of pictures. For translation of the
English texts used, see the respective language pages.
Dimensions
Wall bracket
IHE (18050)
Positioning
Installation height
Minimum mounting distance
Replacing the lamp
Accessories
11884 | IHUB* |
---|---|
18050 | IHE |
16975 | IHXH* |
16976 | IHXL* |
11887 | IHT* |
16974 | IHTW* |
16970 | IHP* |
92865 | KLS1KS |
93272 | IHAF |
220646 | IHL1000 |
220647 | IHL1500 |
206496 | IHL2000 |
- See separate manual.
Controls
- 92867 IHBD3*
- 10740 CBT
- See separate manual.
Technical specifications
Infrared heater IHW with wide heat distribution (IP44)
Item number| Type| Heat output [W]| Voltage
[V]| Amperage
[A]| Max. filament temperature [°C]| Length
[mm]| Weight
[kg]
---|---|---|---|---|---|---|---
11878| IHW10| 1000| 230V~| 4,3| 2200| 500| 1,9
11879| IHW15| 1500| 230V~| 6,5| 2200| 500| 1,9
11880| IHW20| 2000| 230V~| 8,7| 2200| 676| 2,5
Infrared heater IHF with directed heat distribution (IP44)
Item number| Type| Heat output [W]| Voltage
[V]| Amperage
[A]| Max. filament temperature [°C]| Length
[mm]| Weight
[kg]
---|---|---|---|---|---|---|---
11881| IHF10| 1000| 230V~| 4,3| 2200| 500| 1,9
11882| IHF15| 1500| 230V~| 6,5| 2200| 500| 1,9
11883| IHF20| 2000| 230V~| 8,7| 2200| 676| 2,5
Wiring diagrams
Timer control
Timer control with contactor
- Dimensions
- Wall bracket
- Positioning
- The heaters should heat from at least two directions for even heating Installation height
- Minimum distance
- Flammable material
- IHE, ceiling bracket
- Replacing the lamp
- Accessories
- See separate manual.
- Controls
Timer control
Timer control with contactor
Item number
Type
Heat output [W] Voltage [V] Amperage [A] Max. filament temperature
[°C] Length [mm] Weight [kg]
Main office
Frico AB
Tel: +46 31 336 86 00
Industrivägen 41
SE-433 61 Sävedalen mailbox@frico.se
Sweden www.frico.net
For latest updated information and information about your local contact:
www.frico.net
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>