FRICO IHF15 Infrared Heater Instruction Manual

June 13, 2024
FRICO

FRICO IHF15 Infrared Heater

Product Information

The product is an infrared heater available in two types: IHW with wide heat distribution (IP44) and IHF with directed heat distribution (IP44). It comes in three different models: IHW10, IHW15, and IHW20 for wide heat distribution, and IHF10, IHF15, and IHF20 for directed heat distribution. The heaters have different heat output options ranging from 1000W to 2000W. They operate at a voltage of 230V~ and have an amperage ranging from 4.3A to 8.7A. The length of the heaters varies from 500mm to 676mm, and the weight ranges from 1.9kg to 2.5kg.

Product Usage Instructions

  1. Position the heaters so that they can heat from at least two directions for even heating.
  2. Ensure a minimum mounting distance of 200mm for IHE and 180mm for IHW from the ceiling.
  3. Avoid placing the heaters near flammable materials.
  4. To replace the lamp, follow the steps outlined in the separate manual.
  5. Refer to the separate manual for information on accessories such as IHUB, IHXH, IHT, IHTW, IHP, KLS1KS, IHAF, IHL1000, IHL1500, IHL2000.
  6. For controls such as IHBD3 and CBT, refer to the separate manual for instructions.

Note: For detailed technical specifications and wiring diagrams, please refer to the user manual in your respective language.
The introduction pages consist mainly of pictures. For translation of the English texts used, see the respective language pages.

Dimensions

FRICO -IHF15 -Infrared -Heater -fig \(1\)

Wall bracket

FRICO -IHF15 -Infrared -Heater -fig \(2\)

IHE (18050)

FRICO -IHF15 -Infrared -Heater -fig \(3\)

Positioning

Installation height

Minimum mounting distance

FRICO -IHF15 -Infrared -Heater -fig \(6\) Replacing the lamp

Accessories

11884 IHUB*
18050 IHE
16975 IHXH*
16976 IHXL*
11887 IHT*
16974 IHTW*
16970 IHP*
92865 KLS1KS
93272 IHAF
220646 IHL1000
220647 IHL1500
206496 IHL2000
  • See separate manual.

FRICO -IHF15 -Infrared -Heater -fig \(8\)

Controls

  • 92867 IHBD3*
  • 10740 CBT
  • See separate manual.

Technical specifications

Infrared heater IHW with wide heat distribution (IP44)

Item number| Type| Heat output [W]| Voltage
[V]| Amperage
[A]| Max. filament temperature [°C]| Length
[mm]| Weight
[kg]
---|---|---|---|---|---|---|---
11878| IHW10| 1000| 230V~| 4,3| 2200| 500| 1,9
11879| IHW15| 1500| 230V~| 6,5| 2200| 500| 1,9
11880| IHW20| 2000| 230V~| 8,7| 2200| 676| 2,5

Infrared heater IHF with directed heat distribution (IP44)

Item number| Type| Heat output [W]| Voltage
[V]| Amperage
[A]| Max. filament temperature [°C]| Length
[mm]| Weight
[kg]
---|---|---|---|---|---|---|---
11881| IHF10| 1000| 230V~| 4,3| 2200| 500| 1,9
11882| IHF15| 1500| 230V~| 6,5| 2200| 500| 1,9
11883| IHF20| 2000| 230V~| 8,7| 2200| 676| 2,5

Wiring diagrams

Timer control

FRICO -IHF15 -Infrared -Heater -fig \(10\)

Timer control with contactor

FRICO -IHF15 -Infrared -Heater -fig \(11\)

  • Dimensions
  • Wall bracket
  • Positioning
  • The heaters should heat from at least two directions for even heating Installation height
  • Minimum distance
  • Flammable material
  • IHE, ceiling bracket
  • Replacing the lamp
  • Accessories
  • See separate manual.
  • Controls

Timer control
Timer control with contactor
Item number
Type
Heat output [W] Voltage [V] Amperage [A] Max. filament temperature
[°C] Length [mm] Weight [kg]

Main office
Frico AB
Tel: +46 31 336 86 00
Industrivägen 41
SE-433 61 Sävedalen mailbox@frico.se
Sweden www.frico.net
For latest updated information and information about your local contact: www.frico.net

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals