Imperial 2601 Quik Start Compressor Instructions
- June 13, 2024
- imperial
Table of Contents
Imperial 2601 Quik Start Compressor
Product Information
The product is a Model 2601 Quik-Start Hermetic Compressor Starter. It is designed to start all single-phase compressors up to 5HP with voltage options of 110, 220, or 277 VAC. The starter comes with a limited warranty of one year from the date of purchase, covering defects in workmanship or materials.
Features
- Compatible with single-phase compressors up to 5HP
- Voltage options : 110V, 220V, or 277V AC
- Includes safety precautions for proper usage
- Comes with a limited one-year warranty
Accessories
The Model 2605 Test Lead Kit is available as an accessory. It includes four
heavy-duty test leads with colored insulated clips on each end, a 6 ft. power
cord with a male plug on one end and insulated clips on the other, and a 220V
adaptor cord with a female receptacle on one end and insulated clips on the
other.
Manufacturer Information
The product is manufactured by Imperial Tools. The manufacturer assumes no
liability for the actual use of the equipment, as safety responsibility lies
with the user. For warranty and return process information, please visit the
manufacturer’s website at www.imperial-tools.com/warranty.
Manufacturer Contact Information
- Imperial Tools
- 30333 Emerald Valley Parkway
- Glenwillow, OH 44139
- USA
Product Usage Instructions
- Before using the Quik-Start, ensure that the compressor does not have grounded windings. Connect an ohmmeter from the COMMON terminal to the compressor case. If any reading less than infinity (open) is shown, the compressor is defective and should not be used with the Quik-Start.
- To measure compressor amperage draw, place a clamp-on ammeter around the WHITE Quik-Start lead.
- Ensure safety by following these precautions
- Do not use fuses rated higher than 30A.
- Disconnect the system being tested from power before using the Quik-Start.
- Make all required connections to the compressor and components before connecting the Quik-Start to power.
- Avoid touching the compressor case when using the Quik-Start.
- Do not attempt to use the Quik-Start if the compressor windings are grounded.
- When using the 220V adaptor leads from the Model 2605 Test Lead Kit, properly ground the green lead at the 220V source.
- Before removing the system wiring and Quik-Start leads after testing, discharge capacitors by shorting across the capacitor terminals with a screwdriver or test lead. Alternatively, soldering a 15000 ohm 1-watt resistor across the capacitor terminals will automatically discharge the capacitor without altering its performance.
WARNING
- This device is intended for use only by qualified air conditioning and refrigeration service technicians. Use extreme caution when using this unit. Make sure the system being tested is disconnected from power before connecting the Quik Start.
- Do not use fuses rat-ed higher than 30A. Read all safety precautions carefully before using.
- Before using the Quik Start, check the compressor for grounded windings. Connect an ohmmeter from the COMMON terminal to the compressor case. If the ohmmeter shows any reading less than infinity (open), the compressor is defective and the Quik Start should not be used.
- Compressor amperage draw can be measured by placing a clamp ammeter around the WHITE Quek Start lead.
CAPACITOR START COMPRESSORS
Follow Split Phase procedure except for the two YELLOW lead connections. These leads are connected to the starting capacitor as shown above. The capacitor can be any value and voltage equal to or – greater than the original supplied with the compressor. A 200 MFD 220V capacitor will start most of the compressors in use.
ACCESSORIES
Model 2605 Test Lead Kit provides Four (4) 30 in. heavy duty test leads with
colored insulated clips on each end, a 6 ft. power cord with male plug on one
end and insulated clips on the other, and a 220V
adaptor cord with a female receptacle on one end and insulated clips on the
other.
LIMITED WARRANTY
This product is warrantied against defects in workmanship or materials for a
period of one year from date of purchase. Product failures due to abuse,
improper use, normal wear and tear or alteration are not covered by the
warranty. If the product is found to be covered under warranty, we will
repair, replace or credit at our discretion. Please visit www.imperial-
tools.com/warranty for warranty and
return process information.
Manufacturer assumes no liability on the actual use of this equipment. Safety
responsibility lies with the user.
SPLIT PHASE COMPRESSORS
- Set Quik Start STARTING switch to the OFF position.
- Connect the leads as shown above. The two YELLOW leads are connected together.
- Plug in the Quik Start power cord to grounded outlet. For 220V compressors use adaptor leads from 2605 kit.
- Push STARTING switch to START position and hold.
- Release STARTING switch when compressor starts. The switch will remain in the RUN position until manually turned to OFF. If compressor does not start, turn STARTING switch to OFF.
Safety Precautions
- Do not use fuses rated higher than 30A. The use of larger fuses could endanger the operator and will void the warranty.
- Disconnect the system being tested from power before using the Quik Start.
- Make all required connections to the compressor and
- Do not touch the compressor case when using the Quik Start.
- Do not attempt to use the Quik Start if the compressor windings are grounded.
- When using the 220V adaptor leads from the Model 2605 Test Lead Kit, properly ground the green lead at the 220V source.
- Before removing the system wiring and before removing Quik -Start leads after testing, discharge capacitors by shorting across the capacitor terminals with a screw driver or test lead. Soldering a 15000 ohm 1 watt resistor across the capacitor terminals will automatically discharge the capacitor without altering its performance.
COMPRESSOR TERMINAL IDENTIFICATION
The compressor terminals can be identified by using an ohmmeter set to OHMS X
1 and measuring the resistance between terminals.
- Find the two terminals that give the highest resistance reading. The remaining terminal is COMMON.
- Find the two terminals with the lowest resistance. The remaining terminal is START.
- The remaining unidentified terminal is RUN.